• Title/Summary/Keyword: Spacer

Search Result 1,777, Processing Time 0.034 seconds

EFFECTS OF GRID SPACER WITH MIXING VANE ON ENTRAINMENTS AND DEPOSITIONS IN TWO-PHASE ANNULAR FLOWS

  • KAWAHARA, AKIMARO;SADATOMI, MICHIO;IMAMURA, SHOGO;SHIMOHARAI, YUTA;HIRAKATA, YUDAI;ENDO, MASATO
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.389-397
    • /
    • 2015
  • The effects of mixing vanes (MVs) attached to a grid spacer on the characteristics of air-water annular flows were experimentally investigated. To know the effects, a grid spacer with or without MV was inserted in a vertical circular pipe of 16-mm internal diameter. For three cases (i.e., no spacer, spacer without MV, and spacer with MV), the liquid film thickness, liquid entrainment fraction, and deposition rate were measured by the constant current method, single liquid film extraction method, and double liquid film extraction method, respectively. The MVs significantly promote the re-deposition of liquid droplets in the gas core flow into the liquid film on the channel walls. The deposition mass transfer coefficient is three times higher for the spacer with MV than for the spacer without MV, even for cases 0.3-m downstream from the spacer. The liquid film thickness becomes thicker upstream and downstream for the spacer with MV, compared with the thickness for the spacer without MV and for the case with no spacer.

The impact of Spacer on Short Channel Effect and device degradation in Tri-Gate MOSFET (Tri-Gate MOSFET에 SPACER가 단채널 및 열화특성에 미치는 영향)

  • Baek, Gun-Woo;Jung, Sung-In;Kim, Gi-Yeon;Lee, Jae-Hun;Park, Jong-Tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.749-752
    • /
    • 2014
  • The device performance of n-channel MuGFET with different fin width, existence of spacer and channel length has been characterized. Tri-Gate structure(fin number=10) has been used. There are four kinds of Tri-Gate with fin width=55nm with spacer, fin width=70nm with spacer, fin width=55nm without spacer, fin width=70nm without spacer. DIBL, subthreshold swing, Vt roll-off, (above Short Channel Effect)and hot carrier stress degradation have been measured. From the experiment results, short Channel Effect with spacer was decreased, hot carrier degradation with spacer and narrow fin width was decreased. Therefore, layout of LDD structure with spacer and narrow fin width is desirable in short channel effect and hot carrier degradation.

  • PDF

PERFORMANCE EVALUATION OF NEW SPACER GRID SHAPES FOR PWRS

  • Song, Kee-Nam;Lee, Soo-Bum;Lee, Sang-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.737-746
    • /
    • 2007
  • A spacer grid, which is one of the most important structural components in a PWR fuel assembly, supports its fuel rods laterally and vertically. Based on in-house design experience, scrutiny of the design features of advanced nuclear fuels and the patents of other spacer grids, KAERI has devised its own spacer grid shapes and acquired patents. In this study, a performance evaluation of KAERI's spacer grid shapes was carried out from mechanical/structural and thermohydraulic view points. A comparative performance evaluation of commercial spacer grid shapes was also carried out. The comparisons addressed the spring characteristics, fuel rod vibration characteristics, fretting wear resistance, impact strength characteristics, CHF enhancement, and the pressure drop level of the spacer grid shapes. The results show that the performances of KAERI's spacer grid shapes are as good as or better than those of the commercial spacer grid shapes.

Characteristics of Surface Flashover on Partially Immersed of Spacer in Liquid Nitrogen (액체질소 중에서 spacer의 부분적 침적에 대한 연면 방전특성)

  • 김영석;이병성;백승명;정종만;정순용;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.2
    • /
    • pp.177-182
    • /
    • 2000
  • Composite insulation system of liquid nitrogen and solid spacer is widely applied in high temperature superconduction power machine. This study has three step procedure. As follow, first step is composition of parallel deposited electrode and vertically deposited electrode along the direction of immersion in liquid nitrogen(LN2). Second step is investigation into surface flashover voltage of solid spacer under partially immersed in LN2, and last step is comparison the result of this research with that of fully immersed in LN2 and at cryogenic temperature gaseous nitrogen(GN2). This result presented that surface flashover voltage along solid spacer half immersed in LN2 was almost the same as that of fully immersed spacer when the thickness of spacer(t) was t<10mm. In the case of t> 10mm, however, spacer flashover voltage was equal to that obtained in GN2 at cryogenic temperature. And the immersed direction functions as role of deciding the difference of surface flashover voltage.

  • PDF

Design of the Spacer Damper with Automatic Clamping Device for Transmission Line (자동클램핑 장치형 Spacer Damper 설계)

  • Park, Jong-Beom;Ahn, Yong-Ho;Yoon, Gi-Gab;Kim, Kwang-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1790-1795
    • /
    • 2000
  • The purpose of this papery is to introduce a new spacer damper's design for the bundle transmission lines network. It has the design, the main characteristics and advantage of this new kind of spacer damper. To reply to this problems, France, Japan and other countries had developed through many years a spacer damper with an automatic system. While the automatic clamping device are free of maintenance such as fatigue Break and aeolian vibration, imported price are so high. Now it is necessary to design, manufacture and certificate these automatic clamping device spacer damper.

  • PDF

A Study of Neutronics Effects of the Spacer Grids in a Typical PWR via Monte Carlo Calculation

  • Tran, Xuan Bach;Cho, Nam Zin
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.33-42
    • /
    • 2016
  • Spacer grids play an important role in maintaining the proper form of the fuel assembly structure and ensuring the safety of reactor core design. This study applies the Monte Carlo method to the analysis of the neutronics effects of spacer grids in a typical pressurized water reactor (PWR). The core problem used to analyze the neutronics effects of spacer grids is a modified version of Korea Advanced Institute of Science and Technology benchmark problem 1B, based on an Advanced Power Reactor 1400 (APR1400) core model. The spacer grids are modeled and added to this test problem in various ways. Then, by running MCNP5 for all cases of spacer grid modeling, some important numerical results, such as the effective multiplication factor, the spatial distributions of neutron flux, and its energy spectrum are obtained. The numerical results of each case of spacer grid modeling are analyzed and compared to assess which type has more advantages in accuracy of numerical results and effectiveness in terms of geometry building. The conclusion is that the most realistic modeling for Monte Carlo calculation is the "volume-preserving" streamlined heterogeneous spacer grids, but the "banded" dissolution spacer grids modeling is a more practical yet accurate model for routine (deterministic) analysis.

Performance Test on the KAERI Designed Spacer Grids for the Advanced PWR (경수로용 고유 지지격자의 성능시험)

  • Song, Gi-Nam;Yun, Gyeong-Ho;Gang, Heung-Seok;Kim, Hyeong-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.431-437
    • /
    • 2003
  • KAERI has contrived 14 kinds of spacer grid shapes of its own since 1997 and applied for Korean and US patents. To date. KAERI has obtained US and Korean patents for 6 kinds of spacer grid shapes among them. Tn this study. performance test on two spacer grid shapes that are assumed to be the most effective candidates for the spacer grid of the next generation nuclear fuel in Korea was carried Qui through the mechanical/structural test and analysis. The test result has shown thai the performances of the candidates are better or not worse than that of the current spacer grid.

  • PDF

Mechanical/Structural Performance Analysis and Test on the KAERI Designed Spacer Grids for the PWR (한국원자력연구소에서 개발한 가압경수로용 핵연료 지지격자의 기계/구조적 성능 해석 및 시험)

  • Song, K.N.;Yoon, K.H.;Kang, H.S.;Choe, Myeong-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1297-1302
    • /
    • 2003
  • KAERI has contrived 15 kinds of spacer grid shapes of its own since 1997 and applied for domestic and foreign patents. To date, KAERI has obtained US and ROK patents for 6 kinds of spacer grid shapes among them and the others are under review in USA, EC, China, and ROK. In this study, mechanical/structural performance analysis and test on two spacer grid shapes that are assumed to be the most effective candidates for the spacer grid of the next generation nuclear fuel in Korea was carried out. The result has shown that the performances of the candidates are better or not worse than those of the current spacer grid.

  • PDF

A study of Dielectric Strength of Spacer for Tap Changer in a $SF^6 $ Gas Insulated Transformer ($SF^6 $ 가스변압기의 탭절환기용 스페이서의 절연내력에 관한 연구)

  • Heo, U-Haeng;Ha, Yeong-Sik;Hong, Jeong-Gyun;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.11
    • /
    • pp.556-562
    • /
    • 2001
  • Spacer is used between main tank and auxiliary tank for on load tap changer in gas insulated power transformer. This paper deals with electrical design of spacer and discusses different analysis method of between 2D FEM(finite element method) and 3D FEM. To design spacer, we modeled structure of two kind of coaxial cylinders of spacer conductors and analysised electric field of spacer at impulse and induced test voltage condition. Spacer has 13 conductors and electric field was changed according to arrangement of conductors. We could find out arrangement of conductors at which electric stress is minimum. And this arrangement was satisfied with actual test conditions.

  • PDF

Experimental study on Effects of Spacers on Natural Convection from a Horizontal Annulus (수평환상공간(水萍環狀空間)의 자연대류(自然對流)에서 격판(隔板)의 영향에 관한 실험적(實驗的) 연구(硏究))

  • Chung, T.H.;Kim, S.J.;Lee, B.C.;Kwon, S.S.
    • Solar Energy
    • /
    • v.8 no.2
    • /
    • pp.66-72
    • /
    • 1988
  • Natural convection in a horizontal annulus with spacers has been studied on the effects of diameter ratio and Rayleigh numbers and position of spacers by experimental method. In case of vertical spacers, the local spacer Nusselt numbers show positive values on the lower spacer, but negative values on the upper spacer. In case of horizontal spacers, the local spacer Nusselt numbers show positive values on the upward surface of spacer, but negative values on the downward surface of spacer. The mean tube Nusselt numbers and mean cylinder Nusselt numbers with vertical spacer are increased 10% and 2.1%, respectively by those of horizontal spacer.

  • PDF