• 제목/요약/키워드: Space voltage vector modulation

검색결과 211건 처리시간 0.021초

NTV 식별과정 없는 멀티레벨 인버터의 신속한 공간벡터 PWM 변조 기법 (Fast Space Vector PWM Modulation of Multi-Level Inverter Without NTV Identification)

  • 진선호;오진석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권6호
    • /
    • pp.299-305
    • /
    • 2006
  • In this paper, we suggest a new space vector PWM modulation method with very short processing time which does not need identification of nearest three vectors(NTV) and duty ratio for each vector. The suggested PWM method makes mean value of phase voltage to be same as reference during every modulation period by use of a triangle in small hexagon on multi-level vector space. This paper described the suggested modulation method can be successfully applied to the space vector modulation use of multi-level inverter by computer simulations and experiments.

NTV 식별과정 없는 멀티레벨 인버터의 신속한 공간벡터 PWM 변조기법

  • 오진석;이종호;진선호;곽준호;조관준;김종도
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.253-254
    • /
    • 2006
  • this paper suggest a new space vector PWM modulation method with short processing time which does not need idenfication of nearest three vectors(NTV) and duty calculation for each vector. The suggested PWM method makes mean value of phase voltage to be same as reference during every modulation period by use of a triangle in small hexagon on multi-level vector space. This paper described the suggested modulation method can be successfully applied to the space vector modulation use of multi-level inverter by computer simulations and experiments.

  • PDF

공간벡터 전류제어 기법을 이용한 벡터제어형 인버터의 dead time 보상 (Dead Time Compensation of Vector Controlled Inverter Using Space Vector Modulation Method)

  • 홍기필;오원석;김영태;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.265-269
    • /
    • 1994
  • The switching dead time avoiding a bridge leg short circuit in PWM voltage source inverter produces distortions of the controlling inverter output performance such as current waveform, voltage vector, and torque. In this paper, the influence of dead time is investigated. The on-line space voltage vector modulation method is used for current controller. It is possible to compensate dead time by space voltage vector modulation which generates additional pulse compensating voltage distortion caused by dead time. In addition, narrow pulse which is generally neglected can be compensated. All the algorithms, including field-oriented control are performed by one chip microprocessor 80C196MC and DSP TMS320C31. Experimental results probe that the proposed scheme provides a good inverter output performance.

  • PDF

전류 리플 저감을 위한 세분화된 공간전압벡터를 이용한 모델 예측 제어 기반의 SVM 방법 (Space Vector Modulation based on Model Predictive Control to Reduce Current Ripples with Subdivided Space Voltage Vectors)

  • 문현철;이준석;이준희;이교범
    • 전력전자학회논문지
    • /
    • 제22권1호
    • /
    • pp.18-26
    • /
    • 2017
  • This paper proposes the model predictive control with space vector modulation (SVM) method for current control of voltage-source inverter. Unlike the conventional method using a limited number of voltage vectors by switching states, the proposed method can consider various voltage vectors to identify the optimized voltage vector. The various voltage vectors are obtained by subdividing existing voltage vectors. The optimized voltage vector that minimizes the cost function is selected and applied to the inverter by using the SVM. The various voltage vectors and SVM reduce current ripples in the output AC side of the inverter compared with the conventional method. The effectiveness and performance of the proposed method are verified through simulation and experiment with a three-phase two-level voltage-source grid-connected inverter.

2상 인버터를 위한 공간 전압벡터 방식 (Space Voltage Vector Pulse Width Modulation for 2-Phase Inverter)

  • 장도현;박재권
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.280-286
    • /
    • 1998
  • In this paper, space voltage vector pulsewidth modulation for 2-phase inverter is proposed. When this method is appled to 2-phase induction motor, the phase difference of voltage between phase A and B is fixed at $90^{\circ}$and amplitude of voltage of phase Ais same with that of phase B. This method have advantages over low-power servo system because this is simple method comparing to 3-phase space vector method which requires d-q transform.

  • PDF

Novel Five-Level Three-Phase Hybrid-Clamped Converter with Reduced Components

  • Chen, Bin;Yao, Wenxi;Lu, Zhengyu
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1119-1129
    • /
    • 2014
  • This study proposes a novel five-level three-phase hybrid-clamped converter composed of only six switches and one flying capacitor (FC) per phase. The capacitor-voltage-drift phenomenon of the converter under the classical sinusoidal pulse width modulation (SPWM) strategy is comprehensively analyzed. The average current, which flows into the FC, is a function of power factor and modulation index and does not remain at zero. Thus, a specific modulation strategy based on space vector modulation (SVM) is developed to balance the voltage of DC-link and FCs by injecting a common-mode voltage. This strategy applies the five-segment method to synthesize the voltage vector, such that switching losses are reduced while optional vector sequences are increased. The best vector sequence is then selected on the basis of the minimized cost function to suppress the divergence of the capacitor voltage. This study further proposes a startup method that charges the DC-link and FCs without any additional circuits. Simulation and experimental results verify the validity of the proposed converter, modulation strategy, and precharge method.

영구자석 직선형 리니어 동기전동기의 오프셋 전압에 의한 공간벡터 PWM의 구현 (Realization of Space Vector PWM using Offset Voltage for PMLSM)

  • 장석명;박지훈;장원범;유대준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1088-1090
    • /
    • 2004
  • This paper presents control pattern of air-cored slotless permanent magnet linear synchronous motor using voltage modulation method which is used space vector voltage modulation and offset voltage modulation.

  • PDF

PWM 인버터와 PWM 정류기에서 공간벡터변조 (Space Vector Modulation in PWM Inverters and PWM Rectifiers)

  • 권봉환;김한태
    • 대한전기학회논문지
    • /
    • 제41권7호
    • /
    • pp.742-752
    • /
    • 1992
  • In this paper, a space vector concept is generalized for PWM(pulse-width modulated) inverters and PWM rectifiers with current link and voltage link respectively. Through representing three-phase variables as a space vector, we propose space vector modulations for PWM voltage and current source inverters, and PWM rectifiers with current link and voltage link. For these types, switching states of the switches are systematically analyzed from tables. It is shown in three-phase PWM rectifiers that power factor of the line current and output dc voltage can be controlled arbitrarily. The PWM rectifier with current link is also given as an example system.

  • PDF

Implementation of Space Vector Two-Arm Modulation for Independent Motor Control Drive Fed by a Five-Leg Inverter

  • Talib, Md Hairul Nizam;Ibrahim, Zulkifilie;Rahim, Nasrudin Abd.;Abu Hasim, Ahmad Shukri
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.115-124
    • /
    • 2014
  • This paper presents the implementation of two-arm modulation (TAM) technique for the independent control of a two-induction motor drive fed by a five-leg inverter (FLI). A carrier-based space vector pulse width modulation technique for TAM is proposed to generate switching signals for FLI. Two independent three-phase space vector modulators are utilized to control two motors. The motor drive system applies two separate indirect field-oriented control methods. The stationary voltage outputs from the vector control are synthesized in the three-phase space vector modulator to generate switching signals for FLI. The performance of the independent control of the motors and the voltage utilization factor are likewise analyzed. Simulation and experimental results verify the effectiveness of the proposed method for the independent control of the two-motor drive system. The proposed technique is successfully validated by dSPACE DS1103 experimental work.

Power Module Bridge Type Auxiliary Resonant AC Link Snubber-Assisted Three-Phase Soft Switching Inverter

  • Hisashi Iyomori;Nagai, Shin-ichiro;Masanobu Yoshida;Eiji Hiraki;Mutsuo Nakaoka
    • Journal of Power Electronics
    • /
    • 제4권2호
    • /
    • pp.77-86
    • /
    • 2004
  • This paper presents a novel three-phase power module bridge type auxiliary resonant AC link snubber for the three-phase voltage-fed sinwave soft switching PWM inverter operating under specific instantaneous space voltage vector modulation. The operating principle of this resonant snubber is described for current source load model during one switching period, along with its design approach based on the simulation data. The performance evaluations of space vector modulation three-phase sinewave soft switching inverter with a new three-phase active auxiliary resonant AC link snubber are discussed as compared with those of three-phase voltage source-fed sinewave hard switching PWM inverter with a standard space voltage vector modulation strategy. The power loss analysis and conventional efficiency estimation of three-phase soft switching PWM inverter using ICBT modules are carried out including all the conduction power losses based upon the measured v-i characteristics of IGBT and its antiparallel diode as well as their switching losses.