• 제목/요약/키워드: Source voltage estimation

검색결과 52건 처리시간 0.027초

가상자속관측기를 이용한 3상 AC/DC PWM PFC 컨버터의 입력전압 센서리스 제어 개선 (Improved Input Voltage Sensorless Control of Three-Phase AC/DC PWM PFC Converter using Virtual Flux Observer)

  • 김영삼;소상호
    • 한국군사과학기술학회지
    • /
    • 제16권4호
    • /
    • pp.566-574
    • /
    • 2013
  • In this paper, direct power control system for three-phase PFC AC/DC converter without the source voltage sensors is proposed. The sinusoidal input current and unity effective power factor are realised based on the estimated flux in the observer. Both active and reactive power calculated using estimated flux. The estimation of flux is performed based on the reduced-order virtual flux observer using the actual currents and the command control voltage. Moreover, source voltage sensors are replaced by a estimated flux. DC output voltage has been compensated by DC output ripple voltage estimation algorithm. The active and reactive powers estimation are performed based on the estimated flux and Phase angle. The proposed algorithm is verified through simulation and experiment.

Accuracy Enhancement of Parameter Estimation and Sensorless Algorithms Based on Current Shaping

  • Kim, Jin-Woong;Ha, Jung-Ik
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2016
  • Dead time is typically incorporated in voltage source inverter systems to prevent short circuit cases. However, dead time causes an error between the output voltage and reference voltage. Hence, voltage equation-based algorithms, such as motor parameter estimation and back electromotive force (EMF)-based sensorless algorithms, are prone to estimation errors. Several dead-time compensation methods have been developed to reduce output voltage errors. However, voltage errors are still common in zero current crossing areas, and an effect of the error is much worse in a low speed region. Therefore, employing voltage equation-based algorithms in low speed regions is difficult. This study analyzes the conventional dead-time compensation method and output voltage errors in low speed operation areas. A current shaping method that can reduce output voltage errors is also proposed. Experimental results prove that the proposed method reduces voltage errors and improves the accuracy of the parameter estimation method and the performance of the back EMF-based sensorless algorithm.

축소차원 Luenberger 관측기를 이용한 단산 PWM 컨버터의 고역률 제어 (The Control of Single Phase Power Factor PWM converter using Reduced-Order Luenberger Observer)

  • 양이우;이용근;김영석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.485-488
    • /
    • 1999
  • In this paper, a current control system for single phase PWM AC/DC converter without the source voltage sensors is proposed. The sinusoidal input current and unity effective power factor are realised based on the estimated source voltage in the controller. The estimation of source voltage is performed by the reduced-order Luenberger observer using actual currents. The estimated source voltage is used to accomplish unity power factor. The proposed method is proved by experiments.

  • PDF

축전지 전원을 사용한 소형선박 추진용 BLDC모터의 전력변환방식에 따른 효율 비교 및 성능 추정 (Efficiency Comparison according to Power Conversion Method and Performance Estimation for Battery Source BLDC Motor Propulsion System of Small Ships)

  • 정태영;정석권
    • 동력기계공학회지
    • /
    • 제14권1호
    • /
    • pp.27-33
    • /
    • 2010
  • We investigate some operation characteristics and energy efficiency of the BLDC motor system driven by different two types power conversion method depends on same battery source for applying to electrical motor propulsion system of a small ship. Also, we suggest an estimation manner of operating performances such as total running distance and operating speed of ships from basic discharge voltage characteristics of batteries. Through some experiments, direct power conversion was better than indirect method on the view point of energy efficiency and the voltage discharge characteristics could be used as important design factor for estimating operating performances of small ships driven by electrical motors.

축소차원 Luenberger 관측기를 이용한 단상 PWM 컨버터의 고역률 제어 (The High Power Factor Control of a Single Phase PWM Converter using a Reduced-Order Luenberger Observer)

  • 양이우;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권8호
    • /
    • pp.529-535
    • /
    • 2000
  • In this paper, a current control system of a single phase PWM AC/DC converter using a reduced-order Luenberger observer without source voltage sensors is proposed. The sinusoidal input current and unity input power factor are realised based on the estimated source voltage performed by the reduced-order Luenberger observer using actual currents and DC link voltage. The poles of the reduced-order Luenberger observer are placed in the left half plane of s-plane by the pole-placement method in order to acquire the stability of the observer. The magnitude and the phase of the estimated source voltage are used to accomplish the unity power factor. The proposed method is implemented by DSP(Digital Signal Processor). Experimental Results verify that the reduced-order observer estimates the source voltage without the estimation error and the control system accomplishes the unity power factor, and constant DC link voltage.

  • PDF

전력선 유도전압 기초 산출을 위한 전자계 해석 (Electromagnetic Field Analysis for Basic Estimation of Power Induction Voltage)

  • 이상무;은창수
    • 대한전자공학회논문지TC
    • /
    • 제47권5호
    • /
    • pp.60-68
    • /
    • 2010
  • 통신서비스에 장애를 유발하는 전력선에 의한 전자유도 현상에 대한 방호를 위하여는 유도전압을 평가하여야 하고 상응한 대책을 수행하여야 한다. 유도전압을 평가하는 방식은 ITU 규격과 일본 유도자료로부터 국내에 도입되어 법률 고시화되어 있는데 이것으로 수용되지 못하는 유도 커플링상의 제원 요소들이 있다. 본 논문에서는 계산 수행 적용이 곤란한 범위를 포괄할 수 있도록 좀더 일반화된 고전적 유도 및 전자파 원론 해석 근간의 전자계 형성에 의한 소스와 관측점의 유도전압 산출 방식에 대한 기술을 분석하여 제시하였다.

입력전류추정에 의한 전압형 PWM 컨버터의 정현추종제어 (Sinusoidal Tracking Control of Voltage Source PWM Converter by Input Current Estimation)

  • 허태원;박지호;신동률;김춘삼;우정인
    • 조명전기설비학회논문지
    • /
    • 제14권4호
    • /
    • pp.39-47
    • /
    • 2000
  • 본 논문에서는 입력전류 추정에 의한 전밥형 PWM 컨버터의 정상상태 및 과도상태 특성을 개선하기 위하여 정현추종제어기를 제안한다. 그리고, 입력전류의 추정방법과 제어기의 구성에 대해서 논의된다. DC 출력전압은 PI제어기로 제어되며, AC 입력전류를 직접추총 제어하는 정현추종 전류제어기가 입력전류 제어기로 사용된다. 정현추종 전류제아기는 좌표변환 알고리즘 없이 사용가능 하므로 제어계를 간소화 할 수 있다. 입력전류 제어계의 전달함수로부터 입력전류의 정상상태오차가 0이 되고, 입력전압의 동에 대해서도 제안한 제어계는 영향을 받지 않는다는 것을 알 수 있다. 아울러 제안한 방법에 대한 타당성이 시뮬레이션 및 부하, 입력 전압 변동에 대한 실험결과로부터 확인할 수 있다.

  • PDF

축소차원 Luenberger 관측기를 이용한 3상 PWM 컨버터의 고역률 제어 (The Control of Three Phase High Power Factor PWM converter using Reduced - Order Luenberger Observer)

  • 양이우;김영조;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2478-2480
    • /
    • 1999
  • In this paper, the authors propose a current control system for three phase PWM AC/DC converter without the source voltage sensors. The sinusoidal input current and unity effective power factor are realised based on the estimated source voltage in the controller. The estimation of source voltage is performed based on Luenberger observer using actual currents. The estimated source voltage is used to accomplish unity power factor. The proposed method is proved by simulations.

  • PDF

Feasible Power Loss Analysis and Estimation of Auxiliary Resonant DC Link Assisted Soft-Switching Inverter with New Zero Vector Generation Method

  • Manabu Kurokawa;Claudio Y. Inaba;M. Rukonuzzaman;Eiji Hiraki;Yoshihiro Konishi;Mutsuo Nakaoka
    • Journal of Power Electronics
    • /
    • 제2권2호
    • /
    • pp.77-87
    • /
    • 2002
  • The purpose of this paper is to improve power conversion efficiency of three-phase soft-switching voltage-source inverter with an auxiliary resonant dc link (ARDCL) snubber circuit. Firstly, the operation principle of ARDCL snubber circuit is described. Secondly, this paper proposes an effictive generation method of zero voltage vector for three-phase voltage-source soft-switching inverter in power losses in which power losses in the ARDCL snubber circuit can be reduced. In particular, zero voltage holding interval in the inverter DC busline can be controlled due to the new generation scheme of zero voltage vector. Thirdly, a simulator for power loss analysis for power loss characteristics based on actual system, is developed. the validity of developed. The validity of developed simulator of proved with experimental results. Finally, power efficency of three-phase inverter is estimated according to high carrier frequency by using the simulatior.

가상 자속관측기를 이용한 3상 AC/DC PFC PWM 컨버터의 직접 전력 센서리스 제어 (Direct Power Sensorless Control of Three-Phase AC/DC PFC PWM Converter using Virtual Flux Observer)

  • 김영삼;권영안
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1442-1447
    • /
    • 2012
  • In this paper, direct power control system for three-phase PWM AC/DC converter without the source voltage sensors is proposed. The sinusoidal input current and unity effective power factor are realised based on the estimated flux in the observer. Both active and reactive power calculated using estimated flux. The estimation of flux is performed based on the Reduced-order flux observer using the actual currents and the command control voltage. The source voltage sensors are replaced by a flux estimator. The active and reactive powers estimation are performed based on the estimated flux and Phase anble. The proposed algorithm is verified through simulation and experiment.