• 제목/요약/키워드: Source reconstruction

검색결과 228건 처리시간 0.028초

전방십자인대 재건술 - 잔류조직 보존술식 - (ACL Reconstruction - Remnant Preserving Technique -)

  • 이병일;천동일
    • 대한관절경학회지
    • /
    • 제13권2호
    • /
    • pp.97-104
    • /
    • 2009
  • Optimal treatment of the torn anterior cruciate ligament (ACL) remains controversial. The complexity of surgically reproducing the natural biomechanical and anatomical function of the ACL has led to a diversity of reconstructive procedures. Controversy continues to exist regarding the best reconstructive procedure for the ACL deficient knee, but currently, there is no ideal method. Because of the increased frequency of ACL injury and the functional impairment resulting from that, the role of mechanoreceptors in the ACL recently has attracted considerable attention. Proper reconstruction of the ruptured ACL does not always have good results. Success after operation may depend not only on the mechanical stability but also on the quality of recovery of proprioception. It is well known that most ACL are ruptured in proximal half and most mechanoreceptors have been reported to be located in the subsynovial layer and near the tibial insertion of the ACL. Expected roles of tibial remnant is to enhance the revascularization and cellular proliferation of the graft, to preserve proprioceptive function, and to be able to acquire anatomical placement of the graft without roof impingement. The remnant of the ruptured ACL has been removed to clearly visualize the ACL footprint or decrease the risk of impingement and Cyclops lesion in most current techniques for ACL reconstruction. Therefore it seems reasonable to assume that preserving the tibial remnant as much as possible as a source of reinnervation, if technically possible without causing impingement, would be of potential benefit to the patient. In addition, it will facilitate the vascular ingrowth and ligamentization of the grafted ACL.

  • PDF

비가간섭광을 이용한 내부전반사 홀로그래픽 리소그라피 (Total-internal-reflection Holographic Photo-lithography by Using Incoherent Light)

  • 이준섭;박우제;이지환;송석호;이성진
    • 한국광학회지
    • /
    • 제20권6호
    • /
    • pp.334-338
    • /
    • 2009
  • 최근 디스플레이 기기의 수요가 증대되면서 대면적 노광에 대한 요구가 증대되고 있는데, 내부전반사(total internal reflection: TIR)홀로그래픽 리소그라피는 대면적 노광을 위한 효과적인 방법으로 연구가 진행되고 있다. TIR 홀로그래피에서는 일반적으로 레이저를 이용하여 영상을 기록하고 재생한다. 그러나 자외선 램프와 같은 비가간섭광을 이용하여 재생한다면, 가간섭성에 의해 나타나는 영상잡음을 줄일 수 있고, 대면적 노광에도 보다 용이할 것이다. TIR 홀로그램의 재생을 위하여 자외선 램프를 이용할 때, 램프의 유한한 선폭과 확산각이 재생 영상에 미치는 영향을 분석하고, 재생패턴에 나타나는 선폭 확대 결과를 실험을 통하여 검증하였다. ${\mu}m$ 규모의 선폭을 갖는 대면적 패턴을 TIR 홀로그램으로부터 얻기 위한 재생 광원으로, 가간섭성 광원인 레이저 대신 저잡음성과 경제성을 갖춘 일반적인 자외선 램프의 사용이 가능할 것으로 기대된다.

A STUDY ON INDUSTRIAL GAMMA RAY CT WITH A SINGLE SOURCE-DETECTOR PAIR

  • Kim Jong-Bum;Jung Sung-Hee;Kim Jin-Sup
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.383-390
    • /
    • 2006
  • Having its roots in medical applications, industrial gamma ray CT has opened up new roads far investigating and modeling industrial processes. Using a line of research related to industrial gamma ray CT, the authors set up a system of single source and detector gamma transmission tomography for wood timber and a packed bed phantom. The hardware of the CT system consists of two servo motors, a data logger, a computer, a radiation source and a radiation detector. One motor simultaneously moves the source and the detector for a parallel beam scanning, whereas the other motor rotates the scan table at a preset projection angle. The image is reconstructed from the measured projections by the filtered back projection method. The phantom was designed to simulate a cross section of a packed bed with a void. The radiation source was 20mCi of Cs-137 and the detector was a 1 inch $\times$ 1 inch NaI (TI) scintillator shielded by a lead collimator. The experimental gamma ray CT image has sufficient resolution to reveal air holes and the density distribution inside the phantom. The system could possibly be applied to a packed bed column or a pipe flow in a petrochemical plant.

성공적인 전방십자인대 재건술을 위한 적절한 이식건의 선택 (Graft Considerations for Successful Anterior Cruciate Ligament Reconstruction)

  • 경희수
    • 대한정형외과학회지
    • /
    • 제56권1호
    • /
    • pp.14-25
    • /
    • 2021
  • 성공적인 전방십자인대 재건술을 얻기 위해 수술 전 계획, 수술수기, 수술 후 재활 등 여러 가지 요소가 관여한다. 그리고 좋은 결과를 얻기 위해서 수술 중 이식건의 선택, 고정, 처리 방법, 성숙, 본체골에 병합, 장력 등을 고려해야 한다. 이식건을 선택할 때 이식건의 강도, 이식건의 고정방법, 고정부위 치유, 공유 부위 이환, 이식건의 표면적 크기 등을 고려해야 한다. 이식건에는 자가건과 동종건의 두 가지가 있다. 자가 슬개건, 슬괵건, 대퇴사두건 등 사용할 수 있는 자가건은 여러 가지가 있으며 각각의 장·단점을 가지고 있다. 최근 국내에서 동종건의 사용빈도가 높아지고 있는데 공여부의 이환이 없고, 수술 시간이 짧고, 수술 후 통증이 적고, 재료가 다양한 장점이 있다. 하지만 동종건이 자가건보다 장기간 추적 결과가 더 좋다는 보고는 없다. 동종건은 골과의 합병이 오래 걸리고, 불완전하며, 인대 재형성이 늦고, 생역학적으로 자가건보다 강도가 낮으며, 면역반응의 위험성이 높고, 질병 전파의 가능성 등 원초적인 제한점을 가지고 있다. 그래서 장기간 결과에서 실패율이 높고 이식건의 성숙도가 자가건보다 좋지 않다. 그러므로 동종건은 자가건의 대용이 될 수 있지만 자가건을 사용할 수 없을 때, 여러 가지 인대 재건술이 필요한 경우를 제외하고 자가건을 사용하도록 하는 것이 좋다. 만약 적절한 크기와 굵기의 자가건을 얻을 수 있다면 자가건을 사용한 적절한 고정방법을 선택하고 수술 후 재활을 하면 동종건을 사용한 결과보다 우수한 결과를 얻을 것으로 생각된다.

MOCVD를 이용한 GaAs 박막의 에피성장 (Epitaxial Growth of GaAs Thin Films Using MOCVD)

  • 소명기
    • 산업기술연구
    • /
    • 제24권B호
    • /
    • pp.59-64
    • /
    • 2004
  • GaAs thin films were grown epitaxially by MOCVD method on (001) GaAs substrate. And as a surfactant, Bi(bismuth) thin films were deposited on GaAs buffer layer by using TMBi(trimethylbismuth) source. In-situ reflectance difference spectroscopy(RDS) was used to monitor the surface reconstruction of GaAs and Bi thin films. As the results, under the exposure of TBAs(tertiarybuthylarsine) and hydrogen atmosphere, the surface reconstruction of GaAs was changed from As-rich c($4{\times}4$) to As-rich ($2{\times}4$), which was due to the adsoption and desorption of As dimers. The first bismuth surface related RDS signal was reported. At the deposition temperature of $450^{\circ}C$, Bi-terminated GaAs surface showed the RDS spectrum similar to that of Sb-terminated GaAs surface, possibly a ($2{\times}4$) surface. And Bi surface layers were rapidly evaporated with increasing the deposition temperature($550^{\circ}C$), finally becoming As-terminated ($2{\times}4$) surface.

  • PDF

Palmar Hand Wound Coverage with the Free Flaps

  • Roh, Si Young;Lee, Kyung Jin;Lee, Dong Chul;Kim, Jin Soo;Yang, Jae-Won
    • Archives of Reconstructive Microsurgery
    • /
    • 제23권2호
    • /
    • pp.45-50
    • /
    • 2014
  • Palmar soft tissue defects are best reconstructed using a replacement flap of proper size with adequate soft tissue stability for mechanical resistance as well as with protective sensation. Reconstructive approaches are dictated by injury mechanism, defect size and location, and the status of the wound bed and tendino-skeletal structure. While uninjured portions of the hand can be used as a source for local flaps, the use of free flaps allows for maximal access for selection of the most ideal replacement tissue for the defect to be restored as close to the initial state as possible. Here, we review the garden variety of free flaps used in reconstruction of palmar soft tissue defects.

Usefulness of sectional images in dural AVF for the interpretation of venous anatomy

  • Myongjin Kang;Sanghyeon Kim
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제26권2호
    • /
    • pp.119-129
    • /
    • 2024
  • Knowledge of the venous anatomy is essential for appropriately treating dural arteriovenous fistulas (AVFs). It is challenging to determine the overall venous structure despite performing selective angiography for dural AVFs with feeder from multiple selected arteries. This is because only a part of the veins can be observed through the shunt in the selected artery. Therefore, after performing selective angiography of all vessels to understand the approximate venous anatomy, the venous anatomy can be easily understood by closely examining the source image of computed tomographic angiography or magnetic resonance angiography. Through this, it is possible to specify the vein that is to be blocked (target embolization), thereby avoiding extensive blocking of the vein and avoiding various complications. In the case of dural AVF with feeder from single selected artery, if the multiplanar reconstruction image of the three-dimensional rotational computed tomography obtained by performing angiography is analyzed thoroughly, a shunted pouch can be identified. If embolization is performed by targeting this area, unnecessary sinus total packing can be avoided.

Hybrid MBE Growth of Crack-Free GaN Layers on Si (110) Substrates

  • 박철현;오재응;노영균;이상태;김문덕
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.183-184
    • /
    • 2013
  • Two main MBE growth techniques have been used: plasma-assisted MBE (PA-MBE), which utilizes a rf plasma to supply active nitrogen, and ammonia MBE, in which nitrogen is supplied by pyrolysis of NH3 on the sample surface during growth. PA-MBE is typically performed under metal-rich growth conditions, which results in the formation of gallium droplets on the sample surface and a narrow range of conditions for optimal growth. In contrast, high-quality GaN films can be grown by ammonia MBE under an excess nitrogen flux, which in principle should result in improved device uniformity due to the elimination of droplets and wider range of stable growth conditions. A drawback of ammonia MBE, on the other hand, is a serious memory effect of NH3 condensed on the cryo-panels and the vicinity of heaters, which ruins the control of critical growth stages, i.e. the native oxide desorption and the surface reconstruction, and the accurate control of V/III ratio, especially in the initial stage of seed layer growth. In this paper, we demonstrate that the reliable and reproducible growth of GaN on Si (110) substrates is successfully achieved by combining two MBE growth technologies using rf plasma and ammonia and setting a proper growth protocol. Samples were grown in a MBE system equipped with both a nitrogen rf plasma source (SVT) and an ammonia source. The ammonia gas purity was >99.9999% and further purified by using a getter filter. The custom-made injector designed to focus the ammonia flux onto the substrate was used for the gas delivery, while aluminum and gallium were provided via conventional effusion cells. The growth sequence to minimize the residual ammonia and subsequent memory effects is the following: (1) Native oxides are desorbed at $750^{\circ}C$ (Fig. (a) for [$1^-10$] and [001] azimuth) (2) 40 nm thick AlN is first grown using nitrogen rf plasma source at $900^{\circ}C$ nder the optimized condition to maintain the layer by layer growth of AlN buffer layer and slightly Al-rich condition. (Fig. (b)) (3) After switching to ammonia source, GaN growth is initiated with different V/III ratio and temperature conditions. A streaky RHEED pattern with an appearance of a weak ($2{\times}2$) reconstruction characteristic of Ga-polarity is observed all along the growth of subsequent GaN layer under optimized conditions. (Fig. (c)) The structural properties as well as dislocation densities as a function of growth conditions have been investigated using symmetrical and asymmetrical x-ray rocking curves. The electrical characteristics as a function of buffer and GaN layer growth conditions as well as the growth sequence will be also discussed. Figure: (a) RHEED pattern after oxide desorption (b) after 40 nm thick AlN growth using nitrogen rf plasma source and (c) after 600 nm thick GaN growth using ammonia source for (upper) [110] and (lower) [001] azimuth.

  • PDF

작물 분류를 위한 딥러닝 기반 비지도 도메인 적응 모델 비교 (Comparison of Deep Learning-based Unsupervised Domain Adaptation Models for Crop Classification)

  • 곽근호;박노욱
    • 대한원격탐사학회지
    • /
    • 제38권2호
    • /
    • pp.199-213
    • /
    • 2022
  • 비지도 도메인 적응은 연단위 작물 분류를 위해 매년 반복적으로 양질의 훈련자료를 수집해야 하는 비실용적인 문제를 해결할 수 있다. 이 연구에서는 작물 분류를 위한 딥러닝 기반 비지도 도메인 적응 모델의 적용성을 평가하였다. 우리나라 마늘, 양파 주산지인 합천군과 창녕군을 대상으로 무인기 영상을 이용한 작물 분류 실험을 통해 deep adaptation network (DAN), deep reconstruction-classification network, domain adversarial neural network (DANN)의 3개의 비지도 도메인 적응 모델을 정량적으로 비교하였다. 비지도 도메인 적응 모델의 분류 성능을 평가하기 위해 소스 베이스라인 및 대상 베이스라인 모델로 convolutional neural networks (CNNs)을 추가로 적용하였다. 3개의 비지도 도메인 적응 모델은 소스 베이스라인 CNN보다 우수한 성능을 보였으나, 소스 도메인 영상과 대상 도메인 영상의 자료 분포 간 불일치 정도에 따라 서로 다른 분류 성능을 보였다. DAN의 분류 성능은 두 도메인 영상 간 불일치가 작을 때 다른 두 모델에 비해 분류 성능이 높은 반면에 DANN은 두 도메인 영상 간 불일치가 클 때 가장 우수한 분류 성능을 보였다. 따라서 신뢰할 수 있는 분류 결과를 생성하기 위해 두 도메인 영상의 분포가 일치하는 정도를 고려해서 최상의 비지도 도메인 적응 모델을 선택해야 한다.

몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석 (The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation)

  • 정주영;윤도군;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.253-258
    • /
    • 2013
  • 본 연구의 목적은 electronic portal imaging device (EPID)를 통하여 방사선 치료를 받는 환자로부터 투과해 나오는 선량으로 외부적인 선량 재구성과 몬테카를로 전산모사로부터 도출되는 내부 선량 계측과의 관계를 도출하고 이를 분석하기 위한 연구로 진행되었다. 본 연구는 전산모사 연구로써 두 가지의 경우를 비교 분석하고 이와 비슷한 연구에 대한 기본적인 지표를 제공하고자 시행되었다. 실험에 관한 기하학적 정보와 방사선 소스에 대한 정보를 몬테카를로 전산모사 툴인 Monte Carlo n-particle (MCNPX)에 입력하였고 EPID 이미지 도출을 위하여 MCNPX 내에 tally카드를 이용하여 선량정보를 도출하고 이를 영상화 할 수 있도록 하였다. 또한 내부적인 계측을 위하여 물 팬텀을 소스와 표면의 거리(source to surface distance, SSD)가 100 cm이 되도록 설정하였으며, 그보다 10 cm 아래에 EPID를 위치시켰다. 내부 계측은 물팬텀 자체에서 흡수되는 흡수 선량을 mesh tally로 수집하였고, 4문 조사를 통하여 중첩된 선량에 대한 데이터를 획득하였다. 그와 동시에 EPID에서 물을 투과해 나오는 선량을 획득 한 뒤 역 투사 방법을 사용하여 선량 재구성을 하였다. 이둘의 경우를 비교하기 위해 자체적인 교정(calibration)을 통하여 투과해 나온 선량과 흡수된 선량과의 관계를 비교하고 4문 조사를 통하여 물 팬텀 내의 특정 부분에 대한 중첩된 선량 데이터와 EPID를 통해 재구성한 선량 데이터를 분석하였다. 물 팬텀과 EPID에서 획득한 누적 선량의 합은 각각 평균 3.4580 MeV/g과 3.4354 MeV/g이었다. 이는 앞서 계측된 물 팬텀 내부의 누적 선량과 0.6536% 선량 오차를 보였다.