• Title/Summary/Keyword: Source reconstruction

Search Result 228, Processing Time 0.031 seconds

Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography (MDCT에서의 Convolution Kernel 종류에 따른 공간 영역 필터링의 영상 평가)

  • Lee, Hoo-Min;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.71-81
    • /
    • 2008
  • Our objective was to evaluate the image of spatial domain filtering as an alternative to additional image reconstruction using different kernels in MDCT. Derived from thin collimated source images were generated using water phantom and abdomen B10(very smooth), B20(smooth), B30(medium smooth), B40 (medium), B50(medium sharp), B60(sharp), B70(very sharp) and B80(ultra sharp) kernels. MTF and spatial resolution measured with various convolution kernels. Quantitative CT attenuation coefficient and noise measurements provided comparable HU(Hounsfield) units in this respect. CT attenuation coefficient(mean HU) values in the water were values in the water were $1.1{\sim}1.8\;HU$, air($-998{\sim}-1000\;HU$) and noise in the water($5.4{\sim}44.8\;HU$), air($3.6{\sim}31.4\;HU$). In the abdominal fat a CT attenuation coefficient($-2.2{\sim}0.8\;HU$) and noise($10.1{\sim}82.4\;HU$) was measured. In the abdominal was CT attenuation coefficient($53.3{\sim}54.3\;HU$) and noise($10.4{\sim}70.7\;HU$) in the muscle and in the liver parenchyma of CT attenuation coefficient($60.4{\sim}62.2\;HU$) and noise ($7.6{\sim}63.8\;HU$) in the liver parenchyma. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image scanned with a high convolution kernel(B80) led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. Adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination, may control CT images increase the diagnostic accuracy.

  • PDF

Reconstruction of the Extremities with the Dorsalis Pedis Free Flap (족 배 유리 피부판을 이용한 사지 재건술)

  • Lee, Jun-Mo;Kim, Moon-Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.77-83
    • /
    • 1999
  • The skin on the dorsum of the foot is a source of the reliable thin and sensory cutaneous free tissue transplantation with or without tendon, bone and joint. A composite flap with attached vascularized tendon grafts for the combined loss of skin and tendon on the dorsum of the hand and foot offers an immediate one stage solution to this problem. The flap provides a very durable innervated tissue cover for the heel of the foot and the dorsum of the hand and an osteocutaneous transfer combined with the second metatarsal. The major dorsalis pedis artery is constant in size, but the first dorsal metatarsal artery is variable in size and location. The dorsal surface of the foot receives sensory innervation through the superficial peroneal nerve and the first web through the deep peroneal nerve. Authors had performed 5 dorsalis pedis free flap transplantation in the foot and hand at Department of Orthopedic Surgery, Chonbuk National University Hospital from August 1993 through August 1997 and followed up for the period of between 19 and 67 months until March 1999. The results were as follows 1. 5 cases dorsalis pedis free flap transfer to the foot(4 cases) and the hand(1 case) were performed and the recipient was foot dorsum and heel 2 cases each and hand dorsum 1 case. 2 All of 5 cases(100%) were survived from free flap transfer and recipient artery was dorsalis pedis artery(2 cases), anterior tibial artery(1 case), posterior tibial artery(1 case) and ulnar artery(1 case) and recipient veins were 2 in number except in the hand. 3. Long term follow up of the exterior and maceration was good and sensory recovery was poor 4. Donor site was covered with full thickness skin graft obtained from one or both inguinal areas at postoperative 3rd week and skin graft was taken good and no morbidity was showed.

  • PDF

Gamma Ray Detection Processing in PET/CT scanner (PET/CT 장치의 감마선 검출과정)

  • Park, Soung-Ock;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.125-132
    • /
    • 2006
  • The PET/CT scanner is an evolution in image technology. The two modalities are complementary with CT and PET images. The PET scan images are well known as low resolution anatomic landmak, but such problems may help with interpretation detailed anatomic framework such as that provided by CT scan. PET/CT offers some advantages-improved lesion localization and identification, more accurate tumor staging. etc. Conventional PET employs tranmission scan require around 4 min./bed position and 30 min. for whole body scan. But PET/CT scanner can reduced by 50% in whole body scan. Especially nowadays PET scanner LSO scintillator-based from BGO without septa and operate in 3-D acquisition mode with multidetectors CT. PET/CT scanner fusion problems solved through hardware rather than software. Such device provides with the capability to acquire accurately aligned anatomic and functional images from single scan. It is very important to effective detection from gamma ray source in PETdetector. And can be offer high quality diagnostic images. So we have study about detection processing of PET detector and high quality imaging process.

  • PDF

MTF Evaluation and Clinical Application according to the Characteristic Kernels in the Computed Tomogrsphy (Kernel 특성에 따른 MTF 평가 및 임상적 적용에 관한 연구)

  • Yoo, Beong-Gyu;Lee, Jong-Seok;Kweon, Dae-Cheol
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.55-64
    • /
    • 2007
  • Our objective was to evaluate the clinical feasibility of spatial domain filtering as an alternative to additional image reconstruction using different kernels in CT. Kernels were grouped as H30 (head medium smooth), B30 (body medium smooth), S80 (special) and U95 (ultra sharp). Derived from thin coilimated source images, four sets of images were generated using phantom kernels. MTF (50%, 10%, 2%) measured with H30 (3.25, 5.68, 7.45 Ip/cm) B30 (3.84, 6.25, 7.72 Ip/cm), S80 (4.69, 9.49, 12.34 Ip/cm), and U95 (14.19, 20.31, 24.67 Ip/cm). Spatial resolution for the U95 kernel (0.6 mm) was 33.3% greater than that of the H30 and B30 (0.8 mm) kernels. Initially scanned kernels images were rated for subjective image qualify, using a five-point scale. Image scanned with a convolution kernel led to an increase in noise (U95), whereas the results for CT attenuation coefficient were comparable. CT images increase the diagnostic accuracy in head (H30), abdomen (B30), temporal bone and lung (U95) kernels may be controlled by adjusting CT various algorithms, which should be adjusted to take into account the kernels of the CT undergoing the examination.

  • PDF

Magnetic Parameters as Indicators of Late-Quaternary Environments on Fort Riley Kansas (암석 자기 변수들을 이용한 제4기 고환경 복원-Fort Riley 캔사스)

  • Park, kyeong
    • The Korean Journal of Quaternary Research
    • /
    • v.11 no.1
    • /
    • pp.57-68
    • /
    • 1997
  • Climatic change of the late-Quaternary period has been record-ed in the loess deposits of the central Great plains and the record of such change is extractable using a number of approaches and parameters. The stratigraphy of loess deposits which have been investigated on Fort Riley exhibits the same sequence of loess units and intercalated buried soils as is found elsewhere in the re-gion but adds detail unique to the reservation Upland late-Qua-ternary composite stratigraphy preserved on the reservation con-sists of the basal Sangamon soil of the Last interglacial(c. 120-110ka), Gilman Canyon Formation(c. >40 -20ka), Peoria loess(c. 20 -10ka) Brady soil(c. 11 -10ka) Bignell loess(c. 9-\ulcornerka). and mod-ern surface soil. Application of magnetic analyses has provided proxy data sets that represent a time series of climatically regulated pedogenesis/weathering and botanical composition. magetic data have yielded an impression of the variation in climate from Sangamon time to the late Holocene through a reconstruction of the history of pedogenesis/weathering. Sangamon soil formation dominated the reservation durin the Last interglacial as indicated by magnetic parameters. During Gil-man Canyon time loess influx was usually sufficiently slow as to permit pedogenesis which appears to have been at a maximum twice during that time. Warm season grasses were important dur-ing soil formation but diminished in importance during the peri-ods of more rapid loess fall which were cooler and perhaps wet-ter. Peoria loess fall a function of the deterioration of climate during the last Glacial Maximum thinly blanketed the reservation with thickest accumulations occurring to the north-west(Bala Cemetery site)proximal to the source region. Long-term surface stability did not apparently occur within Peoria time but short-term stability may be indicaed by the presence of thin weathering zones(incipient soils) in the Peoria loess. Re-gional landscape stability prevailed during the environmental shift at the Pleistocene/Holocene transition resulting in forma-tion of the well expressed Brady soil. One or more weak soils developed in the Bignell loess as it ac-cumulated. A notable feature of the Bignell loess is the appear-ance of the Altithermal dry period: the loess experienced little weathering and was dominated by warm season grasses until the latter of the Holocene.

  • PDF

Literary Significance and Cultural Character of 'Personal Narrative' ('체험이야기'의 문학적 의의와 문화적 성격)

  • Kyung-Seop Kim;Jeong-Lae Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.133-140
    • /
    • 2023
  • The origin of texts we refer to as literary or artistic may be imagination, but many are based on experiences. In fact, experiences can be the source of artistic imagination since imagination often builds upon experiences. Therefore, the act of verbalizing human experiences using them as raw material can become a great form of art. Transforming past experiences into stories and infusing them with vitality inevitably requires a creative process of reconstruction, which is essentially a literary process. As such, 'Personal Narrative' holds significance as a literary process that weaves facts into stories and shapes them into forms. Individual experiences are stored as personal memories, and these 'personal memories' continuously generate stories. Collections of individual stories are stored as multiple memories, which gradually form 'collective memories' with distinct social and cultural inclinations through the passage of time and invisible yet potent societal and cultural censorship. The problem lies in the fact that individuals may tend to align their own memories with the inclinations of collective memory rather than simply recalling what they personally experienced. In the context of actual history, personal memories and collective memories communicate with each other, producing non-fictional content close to reality and sometimes manifesting as fiction content enriched with imagination. 'Personal Narrative' holds a significant genre as one genre of non-fiction content within our culture.

Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement

  • Suyon Chang;Jung Im Jung;Kyongmin Sarah Beck;Kiyuk Chang;Yaeni Kim;Kyunghwa Han
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.634-643
    • /
    • 2024
  • Objective: This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. Materials and Methods: A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. Results: Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm2 vs. 0.92 cm2 for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. Conclusion: Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.

Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator (Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Kim, Jin-Su;Lee, Byeong-Il;Kim, Soo-Mee;Choung, In-Soon;Kim, Yu-Kyeong;Lee, Won-Woo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.445-455
    • /
    • 2005
  • Purpose: We developed an animal SPECT system using clinical Philips ARGUS scintillation camera and pinhole collimator with specially manufactured small apertures. In this study, we evaluated the physical characteristics of this system and biological feasibility for animal experiments. Materials and Methods: Rotating station for small animals using a step motor and operating software were developed. Pinhole inserts with small apertures (diameter of 0.5, 1.0, and 2.0 mm) were manufactured and physical parameters including planar spatial resolution and sensitivity and reconstructed resolution were measured for some apertures. In order to measure the size of the usable field of view according to the distance from the focal point, manufactured multiple line sources separated with the same distance were scanned and numbers of lines within the field of view were counted. Using a Tc-99m line source with 0.5 mm diameter and 12 mm length placed in the exact center of field of view, planar spatial resolution according to the distance was measured. Calibration factor to obtain FWHM values in 'mm' unit was calculated from the planar image of two separated line sources. Te-99m point source with i mm diameter was used for the measurement of system sensitivity. In addition, SPECT data of micro phantom with cold and hot line inserts and rat brain after intravenous injection of [I-123]FP-CIT were acquired and reconstructed using filtered back protection reconstruction algorithm for pinhole collimator. Results: Size of usable field of view was proportional to the distance from the focal point and their relationship could be fitted into a linear equation (y=1.4x+0.5, x: distance). System sensitivity and planar spatial resolution at 3 cm measured using 1.0 mm aperture was 71 cps/MBq and 1.24 mm, respectively. In the SPECT image of rat brain with [I-123]FP-CIT acquired using 1.0 mm aperture, the distribution of dopamine transporter in the striatum was well identified in each hemisphere. Conclusion: We verified that this new animal SPECT system with the Phlilps ARGUS scanner and small apertures had sufficient performance for small animal imaging.

Analysis of the Shijujils(施主秩), the records on the creation of Buddha statues, of wooden seated Vairocana Buddha Triad of Hwaeomsa Temple (화엄사 목조비로자나삼신불좌상의 조성기 「시주질(施主秩)」 분석)

  • Yoo, Geun-Ja
    • MISULJARYO - National Museum of Korea Art Journal
    • /
    • v.100
    • /
    • pp.112-138
    • /
    • 2021
  • This paper mainly analyzes the records titled 'Shijujil(施主秩)' from the Bokjangs of each of the Rocana and Shakyamuni statues enshrined as wooden seated Vairocana Buddha Triadcomposed of Vairocana(center), Rocana(right), and Shakyamuni(left) at the Daeungjeon Hall of Hwaeomsa Temple in Gurye. The Shijujil from the Shakyamuni statue was recovered through Bokjang investigation in September 2015 and has been kept in the museum of Hwaeomsa as an undisclosed relic. After the discovery of the Shijujil from the Rocana statue through an Bokjang investigation in July 2020, both of the Shijujils were only officially released through the special exhibition 'Grand Hwaeomsa Temple in Jirisan Mountain' in September 2021. Existing documents recording on the creation of Buddha statues in the 17th century are in the form of sheets or rolls. However, the Shijujils take the form of simple stitched booklets. The Shijujil from Rocana consists of 19 chapters and 38 pages in one book, and the Shijujil from Shakyamuni consists of 11 chapters and 22 pages in one book. The contents of the Shijujils consist of the purpose of the Buddha statue creation, the creation date, the year and place of enshrining, the names of the statues, the people in charge and their roles, the sculptors, the list of items donated, and the list of the contributors. In addition, the list of monks who were staying at Hwaeomsa Temple at that time are also recorded, so the Shijujil is like a time capsule that tells the situation of Hwaeomsa Temple about 400 years ago. According to the records of the Shijujils and the Writing on the wooden pedestal of Rocana, the Vairocana Triad began to be in March 1634(12th year of King Injo) and was completed in August of that year, and was enshrined in the Daeungjeon Hall in the fall of the following year. It is very important to confirm that the Vairocana Buddha Triad of Hwaeomsa was created in 1634. Since studies on the reconstruction of Hwaeomsa Temple in the 17th century and the roles of Byeokam Gakseong have been mainly based on 『湖南道求禮縣智異山大華嚴寺事蹟』 written by monk Haean in 1636, it has been estimated that the wooden seated Vairocana Buddha Triad was created in 1636. However, it is now known that the Virocana Buddha Triad was created in 1634. The Shijujils are also a good source of information about Byeokam Gakseong who played a pivotal roles in the reconstruction projects of Hwaeomsa Temple in the 17th century. He played leading roles in rebuilding the East Five-story Stone Pagoda(1630), in creating the wooden seated Vairocana Buddha Triad(1634), and in producing the Yeongsanhoe Gwaebul(1653, Hanging Scroll Painting depicting the Shakyamuni preaching). It is also very important that the Shijujils are records that can reveal the relationship between Byeokam Gakseong and royal family of Joseon Dynasty in the 17th century. The Shijujils from Rocana and Shakyamuni are the first documents ever discovered in which the names of royal family members, such as Uichanggun(Gwang Lee, son of King Seonjo), Ikseong Shin(son-in-law of King Seonjo), and Crown Prince Sohyeon(son of King Injo) are recorded in detail in relation to the production of Buddha statues. The Shijujils from Rocana and Shakyamuni contain specific information about the production of the wooden seated Vairocana Buddha Triad in the 17th century, such as the year of production of the Buddha statues, the role of Byeokam Gakseong, and the relationship between Byeokam Gakseong and the royal family, so it is of great value not only for art history but also for historical studies of Hwaeomsa Temple.

EVALUATION OF OSTEOGENIC ACTIVITY AND MINERALIZATION OF CULTURED HUMAN PERIOSTEAL-DERIVED CELLS (배양된 인간 골막기원세포의 조골활성 및 골기질 형성의 평가)

  • Park, Bong-Wook;Byun, June-Ho;Lee, Sung-Gyoon;Hah, Young-Sool;Kim, Deok-Ryong;Cho, Yeong-Cheol;Sung, Iel-Yong;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.6
    • /
    • pp.511-519
    • /
    • 2006
  • Autogenous bone grafts have been considered the gold standard for maxillofacial bony defects. However, this procedure could entail a complicated surgical procedure as well as potential donor site morbidity. Possibly the best solution for bone-defect regeneration is a tissue engineering approach, i.e. the use of a combination of a suitable scaffold with osteogenic cells. A major source of osteogenic cells is the bone marrow. Bone marrow-derived mesenchymal stem cells are multipotent and have the ability to differentiate into osteoblastic, chondrocytic, and adipocytic lineage cells. However, the isolation of cells from bone marrow has someproblems when used in clinical setting. Bone marrow aspiration is sometimes potentially more invasive and painful procedure and carries of a risk of morbidity and infection. A minimally invasive, easily accessible alternative would be cells derived from periosteum. The periosteum also contains multipotent cells that have the potential to differentiate into osteoblasts and chondrocytes. In the present study, we evaluated the osteogenic activity and mineralization of cultured human periosteal-derived cells. Periosteal explants were harvested from mandibule during surgical extraction of lower impacted third molar. The periosteal cells were cultured in the osteogenic inductive medium consisting of DMEM supplemented with 10% fetal calf serum, 50g/ml L-ascorbic acid 2-phosphate, 10 nmol dexamethasone and 10 mM -glycerophosphate for 42 days. Periosteal-derived cells showed positive alkaline phosphatase (ALP) staining during 42 days of culture period. The formation of ALP stain showed its maximal manifestation at day 14 of culture period, then decreased in intensity during the culture period. ALP mRNA expression increased up to day 14 with a decrease thereafter. Osteocalcin mRNA expression appeared at day 7 in culture, after that its expression continuously increased in a time-dependent manner up to the entire duration of culture. Von Kossa-positive mineralization nodules were first present at day 14 in culture followed by an increased number of positive nodules during the entire duration of the culture period. In conclusion, our study showed that cultured human periosteal-derived cells differentiated into active osteoblastic cells that were involved in synthesis of bone matrix and the subsequent mineralization of the matrix. As the periosteal-derived cells, easily harvested from intraoral procedure such as surgical extraction of impacted third molar, has the excellent potential of osteogenic capacity, tissue-engineered bone using periosteal-derived cells could be the best choice in reconstruction of maxillofacial bony defects.