• 제목/요약/키워드: Source of Waste

검색결과 871건 처리시간 0.026초

pH 조절을 통한 폐활성 슬러지의 COD 가용화 및 감량화 평가 (Evaluation of COD Solubilization and Reduction of Waste Activated Sludge by pH Control)

  • 김연권;문용택;김지연;서인석
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.551-558
    • /
    • 2007
  • From the view point of biological wastewater treatment, C/N ratio is one of the most important factor in biological nutrient removal process. However, municipal sewage in Korea is characterized by extremely low content of carbon source and relatively higher portion of N source. Accordingly, it is necessary to dose external carbon source in order to obtain higher degree of carbon source within the process. In this study, the effects of pH pretreatment as an alternative plan for increasing carbon source on the cell disruption and COD solubility of waste activated sludge were conducted under well defined experimental conditions. During 5 hours, the value of COD solubilization rate ($S_R$) at pH 11.5 is approximately 4.4 times higher than the value of $S_R$ at pH 9.5. It is expected that the level of SCOD increased due to the result from cell disruption. However, VSS/TSS ratio was not significantly changed after 5 hours. As Alkalinity changes gradually from less than 15, 30 and 60 meq NaOH/L, average RBCOD/SCOD fraction showed 34, 36 and 45%,respectively.

이중열원을 이용한 전기자동차용 히트펌프 시스템의 난방 성능 특성에 관한 연구 (Study on the Heating Performance Characteristics of a Heat Pump System Utilizing Air and Waste Heat Source for Electric Vehicles)

  • 우형석;안재환;오명수;강훈;김용찬
    • 설비공학논문집
    • /
    • 제25권4호
    • /
    • pp.180-186
    • /
    • 2013
  • An electric vehicle is an environment-friendly automobile which does not emit any tailpipe pollutant. In a conventional vehicle with an internal combustion engine, the internal cabin of the vehicle is usually heated using waste heat from the engine. However, for an electric vehicle, an alternative solution for heating is required because it does not have a combustion engine. Recently, a heat pump system which is widely used for residential heating due to its higher efficiency has been studied for its use as a heating system in electric vehicles. In this study, a heat pump system utilizing air source and waste heat source from electric devices was investigated experimentally. The performance of the heat pump system was measured by varying the mass flow rate ratio. The experimental results show that the heating capacity and COP in the dual heat source heat pump were increased by 20.9% and 8.6%, respectively, from those of the air-source heat pump.

Investigating the Impact of Best Management Practices on Nonpoint Source Pollution from Agricultural Lands

  • 최예환
    • 한국농공학회지
    • /
    • 제32권E호
    • /
    • pp.1-19
    • /
    • 1990
  • Abstract Over the last several decades, crop production in the United States increased largely due to the extensive use of animal waste and fertilizers as plant nutrient supplements, and pesticides for crops pests and weed control. Without the application of animal waste best management, the use of animal waste can result in nonpoint source pollution from agricultural land area. In order to increase nutrient levels and decrease contamination from agricultural lands, nonpoint source pollution is responsible for water quality degradation. Nonpoint source pollutants such as animal waste, ferilizers, and pesticides are transported primarily through runoff from agricultural areas. Nutrients, primarily nitrogen and phosphorus, can be a major water quality problem because they cause eutrophic algae growth. In 1985, it was presented that Watershed/Water Quality Monitoring for Evaluation BMP Effectiveness was implemented for Nomini Creek Watershed, located in Westmoreland County, Virginia. The watershed is predominantly agricultural and has an aerial extent of 1505 ha of land, with 43% under cropland, 54% under woodland, and 3% as homestead and roads. Rainfall data was collected at the watershed from raingages located at sites PNI through PN 7. Streams at stations QN I and QN2 were being measured with V-notch weirs. Water levels at the stream was measured using an FW-l Belfort (Friez FWl). The water quality monitoring system was designed to provide comprehensive assessment of the quality of storm runoff and baseflow as influenced by changes in landuse, agronomic, and cultural practices ill the watershed. As this study was concerned with the Nomini Creek Watershed, the separation of storm runoff and baseflow measured at QNI and QN2 was given by the master depletion curve method, and the loadings of baseflow and storm runoff for TN (Total Nitrogen) and TP (Total Phosphorus) were analyzed from 1987 through 1989. The results were studied for the best management practices to reduce contamination and loss of nutrients, (e.g., total nitrogen and total phosphorus) by nonpoint source pollution from agricultural lands.

  • PDF

동위원소 생산공정에서 발생한 방사성 폐기물 장기저장소 온도평가 (Temperature Evaluation on Long-term Storage of Radioactive Waste Produced in the Process of Isotope Production)

  • 정남균;조대성
    • 대한기계학회논문집B
    • /
    • 제40권7호
    • /
    • pp.471-475
    • /
    • 2016
  • 본 연구는 의료용 동위원소 생산공정에서 발생하는 방사성폐기물을 저장하는 장기저장소의 온도를 두 가지 방법으로 평가한 결과를 보여준다. 방사성폐기물에서 발생하는 열을 Volume source와 Point source로 가정하여 장기저장소의 온도를 평가한 결과, 폐기물 저장위치에 따른 최대온도분포는 유사하게 나타났으나 그 크기에 있어서 최대 $5^{\circ}C$ 정도의 차이를 보였다. 따라서, 개념설계를 위해서는 해석 시간이 오래 걸리는 Volume source를 이용한 3차원 해석보다는 Point source를 이용한 2차원 해석이 보다 효율적이지만, 상세 설계를 위한 정확한 해석 결과를 얻기 위해서는 Volume source를 이용한 3차원 해석이 수반되어야 함을 알 수 있다.

대형 Community 건물의 지열원 복합 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구 (Analytical Study on the Performance of Ground Source Compound Hybrid Heat Pump System for Large Community Building)

  • 변재기;정동화;이종길;홍성호;최영돈;조성환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.634-637
    • /
    • 2008
  • Ground source heat pumps are clean, energy-efficient and environment-friendly systems cooling and heating. Although the initial cost of ground source heat pump system is higher than that of air source heat pump, it is now widely accepted as an economical system since the installation cost can be returned within an short period of time due to its high efficiency. In the present study, performances of ground source compound hybrid heat pump system applied to a large community building are simulated. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. If among several renewable energy sources, ground, river, sea, waste water source are chosen as available alternative energies are combined, COP of the system can be increased largely and hybrid heat pump system can reduced the fuel cost.

  • PDF

응축폐열을 이용한 건조 및 온수장치에 관한 연구 (A Study on The Drying and Hot Water System Using Condensation Waste Heat)

  • 박노현;고하영;정진웅;강통삼
    • 대한설비공학회지:설비저널
    • /
    • 제15권4호
    • /
    • pp.362-371
    • /
    • 1986
  • In the normal Refrigeration process, the condensation heat of refrigerant s not been used because of its low-temperature waste heat. To recover the condensation waste heat of R-12 refrigerator, a drying and hot water system was designed and experimented. The results obtained were summarized as follows: 1. As the temperature a temosphere was increased, the temperature of discharge gas of compressor was increased. And the temperature was $80-84^{\circ}C$ for air condensing type and was $68-71^{\circ}C$ for water condensing type during summer. 2. The condensation waste heat could be obtained up to $50-55^{\circ}C$ of drying heat-source and Hot water in summer. In this case, recovered rate was about $73\%$. And the more temperature of drying Heat-source and Hot water were increased, the more a recovered rate were decreased. 3. When comparing drying characteristics of Agro-products in dryer of waste heat utilization and Hot air, there was no quality difference in products. But drying time of the former was 3 Hours longer than the latter. 4. The condensation waste heat of compressor could be applied into the drying of marine products, the predrying of agro-products and making hot water. And showed high possibility of the waste heat using in low-temperature storage.

  • PDF

단속식 침출수 순환형 음식물류 폐기물 혐기성 소화 공법에 대한 실험적 특성 파악 (Experimental Evaluation of Intermittent Leachate Recirculation Anaerobic System to digest Source from Separated Food Waste)

  • 이제승;이병희
    • 유기물자원화
    • /
    • 제22권2호
    • /
    • pp.57-66
    • /
    • 2014
  • 침출수 순환형 음식물류 폐기물 혐기성 소화 공법은 기존의 일상 혐기성 소화 공법에 비해 투입되는 유기물 부하량 대비 발생하는 메탄가스 수율이 높다는 장점이 있다. 본 연구는 분리 수거된 교내 기숙사 식당 음식물류 폐기물과 하수처리장 혐기성 소화조의 혐기성 미생물을 이용하여 신재생 에너지인 메탄가스를 더욱 효율적으로 얻기 위해 음식물류 폐기물/혐기성 슬러지 비를 달리하여 실험을 실시하였다. 음식물류 폐기물/혐기성 슬러지 비가 2:8이고 유기물 부하율이 9 gVS/L인 침출수 순환형 음식물류 혐기성 소화 반응조의 바이오 가스 발생이 가장 높았다. 또한 이 혐기성 반응조에서 발생하는 바이오가스 내부의 $H_2S$$NH_3$가 지속적으로 감소하였고 바이오 가스의 수율은 평균 $1.395m^3$ Biogas/kg VS added로 나타났다. 이에 비해 나머지 음식물류 폐기물/혐기성 슬러지 비가 3:7, 8:2인 실험의 반응조에서는 바이오 가스 발생이 멈추었다.

음식물쓰레기 세정산발효액을 외부탄소원으로 주입한 SBR 공정에서 질소 및 인 제거 (Nitrongen and Phosphorus Removal using Elutriated Acids of Food Waste as an External Carbon Source in SBR)

  • 권구호;김시원;이민재;민경석
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.462-467
    • /
    • 2006
  • An improvement of nitrogen and phosphorus removal in SBR using the elutriated acids from the food waste as an external carbon source was investigated in this study. The food waste was elutriated at $35^{\circ}C$ and pH 9 to produce the external carbon source. The elutriate of food waste were continuously collected. The elutriated liquid contained VFAs of 39,180 mg/L representing soluble COD of 44,700 mg/L. The SBR showed poor denitrification and EBPR (enhanced biological phosphorus removal) without elutriated VFAs addition. An average denitrification rate was 0.4 mg NOx-N/g MLVSS/day. In turn, EBPR was also inhibited by this poor denitrification because the remaining nitrate in anaerobic phase resulting a poor denitrification. On the other hand, the denitrification in anoxic phase significantly improved with an elutriated VFAs addition. Nitrate removal was 82% while the denitrification rate was 2.9 mg NOx-N/g MLVSS/day with 18.4 mL/cycle of elutriated VFAs. With the enhanced denitrification, nitrate concentration in anaerobic phase could effectively be controlled to a very low level. The elimination of nitrate inhibition in anaerobic phase resulted enhancement of EBPR. The specific phosphate release rate was $1.9mg\;PO_4^{3-}-P/g\; MLVSS/day$ with less than 0.5 mg/L of $PO_4^{3-}-P$ concentration.

Mcl-PHAs Produced by Pseudomonas sp. Gl01 Using Fed-Batch Cultivation with Waste Rapeseed Oil as Carbon Source

  • Mozejko, Justyna;Wilke, Andreas;Przybylek, Grzegorz;Ciesielski, Slawomir
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권3호
    • /
    • pp.371-377
    • /
    • 2012
  • The present study describes medium-chain-length polyhydroxyalkanoates (mcl-PHAs) production by the Pseudomonas Gl01 strain isolated from mixed microbial communities utilized for PHAs synthesis. A two-step fed-batch fermentation was conducted with glucose and waste rapeseed oil as the main carbon source for obtaining cell growth and mcl-PHAs accumulation, respectively. The results show that the Pseudomonas Gl01 strain is capable of growing and accumulating mcl-PHAs using a waste oily carbon source. The biomass value reached 3.0 g/l of CDW with 20% of PHAs content within 48 h of cultivation. The polymer was purified from lyophilized cells and analyzed by gas chromatography (GC). The results revealed that the monomeric composition of the obtained polyesters depended on the available substrate. When glucose was used in the growth phase, 3-hydroxyundecanoate and 3-hydroxydodecanoate were found in the polymer composition, whereas in the PHAs-accumulating stage, the Pseudomonas Gl01 strain synthesized mcl-PHAs consisting mainly of 3-hydroxyoctanoate and 3-hydroxydecanoate. The transcriptional analysis using reverse-transcription real-time PCR reaction revealed that the phaC1 gene could be transcribed simultaneously to the phaZ gene.

배열 이용형 흡수식 사이클 특성평가 (Characteristics Evaluation of Absorption Cycles using the Waste Heat)

  • 윤정인;권오경;문춘근
    • 태양에너지
    • /
    • 제18권4호
    • /
    • pp.23-32
    • /
    • 1998
  • Fuel cells supply electric power and heat at work, and their exhaust gas is comparatively clear. So they are in the limelight as one of the co-generation systems which behave friendly with the environment. Fuel cells discharge both steam and hot water. Accordingly, if we combine absorption heat pump driven by waste heat with fuel cells, we can construct an advanced energy conserving system. The purpose of this study is the objective for evaluating the possibilities of effectively utilizing waste heat of fuel cells as a heat source for the single and double effect absorption systems. Simulation studies on single and double effect absorption have been performed for water/lithium-bromide pair. The effectiveness of introducing a waste heat source of fuel cells is demonstrated. The result of this study showed that total efficiency was about 85% at rated operation and about 75% at 75% load operation. Absorption cycle moved to more strong concentration when fuel cell operated at 75% load.

  • PDF