• Title/Summary/Keyword: Source and Impact Area

Search Result 205, Processing Time 0.029 seconds

Hydrogeologic and Hydrogeochemical Assessment of Water Sources in Gwanin Water Intake Plant, Pocheon (포천 관인취수장 수원에 대한 수리지질 및 수리지구화학적 평가)

  • Shin, Bok Su;Koh, Dong-Chan;Chang, Yoon-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.3
    • /
    • pp.209-221
    • /
    • 2016
  • The section from water source to 2.6km upper stream of Hantan River is protected as the drinking water quality protection area according to guidelines of Ministry of Environment, because water source of the Gwanin water intake plant has been known the river. However, opinions were consistently brought up that the standard of water source protection zone must be changed with using underground water as water source because of contribution possibility of underground water as the water source of Gwanin water intake facility. In this regard, hydrogeologic investigation including resistivity survey and hydrogeochemical investigation were carried out to assess water source and infiltration of contaminant for the plant. Quaternary basaltic rocks (50m thick with four layers) covered most of the study area on the granite basement. As the result of the resistivity survey, it is revealed that permeable aquifer is distributed in the boundary of two layers: the basaltic layer with low resistivity; and the granite with high resistivity. Considering of outflow from Gwanin water intake facility, the area possessing underground water was estimated at least $5.7km^2$. The underground water recharged from Cheorwon plain was presumed to outflow along the surface of unconformity plane of basalt and granite. Based on field parameters and major dissolved constituents, groundwater and river water clearly distinguished and the spring water was similar to groundwater from the basaltic aquifer. Temporal variation of $SiO_2$, Mg, $NO_3$, and $SO_4$ concentrations indicated that spring water and nearby groundwater were originated from the basaltic aquifer and other groundwater from granitic aquifer. In conclusion, the spring of the Gwanin water intake plant was distinguished from river water in terms of hydrogeochemical characteristics and mainly contributed from the basaltic aquifer.

Preliminary Assessment of Radiation Impact from Dry Storage Facilities for PWR Spent Fuel (경수로 사용후핵연료 건식 중간저장시설에 대한 예비 방사선 영향 평가)

  • Kim, T.M.;Baeg, C.Y.;Cha, G.Y.;Lee, W.G.;Kim, S.Y.
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.197-201
    • /
    • 2012
  • Annual dose at the boundary of the interim storage facility at normal condition was calculated to estimate the site area of the facility of PWR spent nuclear fuel. In this work, source term was generated by ORIGEN-ARP for 4.5 wt% initial enrichment, 45,000 MWd/MTU burnup and 10 years cooling time. Modeling of the storage facilities and radiation shielding evaluations were conducted by MCNP code depending on the storage capacity. In the case of the centralized storage system, the required site area was found to have the radius of more than 700 m.

Evaluation of Pollution Level Attributed to Nonpoint Sources in Nakdonggang Basin, Korea (낙동강수계 권역별 비점오염원 오염도 평가)

  • Lee, Jaewoon;Kwon, Heongak;Choi, Hanyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.5
    • /
    • pp.393-405
    • /
    • 2014
  • In this study, the nonpoint sources were evaluated by calculating the Nadonggang basin regional water quality and nonpoint source pollution load discharged. And were selected the banks of first administration based on the results and the direction of the next administration. As a results of estimating the water quality about BOD concentration in the mid influence area in the Nakdonggang basin, it was founded that 10 sites for 'Ia' water quality level, 6 sites for 'lb' water quality level, 5 sites for 'II' water quality level, 1 sites for 'I' water quality level. The estimation of COD concentration in the mid influence area, It showed that 9 sites for 'Ib' water quality level, 6 sites for 'II' water quality level, 6 sites for 'III' water quality level, 1 site for 'IV' water quality level. The assessment of water quality made Mid influence area of Gumhogang, Nakdong Goryung, Nakdong Milyang and Namgang selected as the mid influence area of high pollution. And delivery loads of nonpoint sources were calculated for mid influence area in Nakdonggang basin(max delivery load : 17,706.7 kg/day for Gumhogang influence area). As the result of calculating NPS(nonpoint sources) delivery load and water quality at influence area in Nakdonggang basin, Gumhogang influence area was selected as an area for management priority among nonpoint sources.

Pollutants Removal Efficiency of Rainfall-runoff from Dense Highland Field Areas in Multistage Sedimentation Basins - Focused on Jaun Area in Upstream Watershed of Lake Soyang - (고랭지 밭 밀집지역 다단계 침사지의 강우-유출 오염물질 제거 효율 - 소양호 상류의 자운지구를 중심으로 -)

  • Cho, Jae Heon
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.2
    • /
    • pp.170-180
    • /
    • 2018
  • Highland fields are concentrated in the Jaun area of Hongcheong-gun, a large amount of sediments are discharged from the highland fields. The sediment runoff affect the turbidity and water quality of the Soyang Lake, furthermore adversely affect water supply source of the capital region. There are several kinds of BMPs(Best management practices) to decrease the sedimentrunoff from the highland fields. Although construction cost of multistage sedimentation basins is very high, there is no actual survey data for the removal efficiency of suspended sediments and water quality in our country. In this study, stormwaterinflow and outflow of the multistage sedimentation basins were surveyed, and the removal efficiency of nonpoint source pollutants were analyzed. The stormwater survey results fortwo rainfall events show thatremoval efficiencies of SS, BOD and TP loads in the multistage sedimentation basins are 35%~62%, 24%~55%, 35%~58%, respectively. Although the measured efficiencies of the basins were lower than the theoretical efficiency, the proper operation and management can improve the removal rate of the basins. Turbid water problem in the upper parts of the Soyang River can be managed effectively through the additional installation of multistage sedimentation basins.

VOCs impact factor analysis of unit components in Part assembly by ISO 12219-5 method (ISO 12219-5 (Static chamber법)를 이용한 모듈내 구성부품별 VOCs 영향도 분석)

  • Lee, Shinjong;Jang, Heyjin;Gwak, Donghwan;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.284-291
    • /
    • 2014
  • The handling process of car indoor air quality is composed of 2 steps of testing. First, assambly part is tested to find a source of car indoor VOCs. Second, cut sample of unit component is tested to find a source material of VOCs emission. If the source material of VOCs emission is found, it can reduce car and assembly part of VOCs by improving material. As cut sample testing has problem of emission from cut surface to find the source of VOCs, it needs to apply unit components testing method. The aim of study is to evaluate VOCs impact factor of unit components in assembly parts. ISO 12219-5 test method reflects not only material effect but also surface area effect by testing unit component without cutting. The unit components of doortrim and console, were tested by ISO12219-5. And it could figure what unit component is main source of VOCs in assembly. And quantity conversion Factor which gets by testing assembly and unit components can be used to make guideline of ISO 12219-5.

Water Quality Prediction and Forecast of Pollution Source in Namgang Mid-watershed each Reduction Scenario (남강중권역 오염부하 전망 및 삭감 시나리오별 하류 수질예측)

  • Yu, Jae Jeong;Shin, Suk Ho;Yoon, Young Sam;Kang, Doo Kee
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.4
    • /
    • pp.543-552
    • /
    • 2012
  • Namgang mid-watershed is located in downstream of Nakdong river basin. There are many pollution sources arround this area and it's control is important to manage a water quality of Nakdong river. A target year of Namgang mid-watershed water environment management plan is 2013. To predict a water quality at downstream of Namgang, we have investigated and forecasted the pollutant source and it's loading. There are some plan to construction the sewage treatment plants to improve the water quality of Nam river. Those are considered on predicting water quality. As results, it is shown that the population is 343,326 and sewerage supply rate is 79.2% and the livestock is 1,662,000 in Namgang mid-watershed. It is estimated that the population is 333,980, the sewerage supply rate is 86.9% in 2013. The milk cow and cattle were estimated upward and the pigs were downward by 2013. The generated loading of BOD and TP is 75,957 kg/day and 4,311 kg/day, discharged loading is 18,481 kg/day and 988 kg/day respectively in 2006. It were predicted upward the discharged loading of BOD and TP by 4.08% and 6.3% respectively. The results of water quality prediction of Namgang4 site were 2.5 mg/L of BOD and 0.120 mg/L of TP in 2013. It is over the target water quality at that site in 2015 about 25.0% and 9.1% respectively. Consequently, there need another counterplan to reduce the pollutants in that mid-watershed.

A Study on Empirical Method Analysis of Impervious Surface Using KOMPSAT-2 Image (KOMPSAT-2 위성영상을 이용한 불투수지도작성 방법에 관한 실증연구)

  • Bae, Da-Hye;Lee, Jae-Yil;Ko, Chang-Hwan;Ha, Sung-Ryong
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.5
    • /
    • pp.717-727
    • /
    • 2011
  • Impervious surface affects urban climate, flood, and water pollution and has important role as basic data for urban planning and environmental and resources management uses. With a high paved rate, increased quantity of the outflown water and brings urban flooding during a heavy rain. Moreover, these non-point source pollution is getting increased the water pollution. In this regard, it is definitely important to research and keep monitoring the current situation of paved surface, which influences urban ecosystem, disaster and pollution. In this study, we suggest a method to utilize high resolution satellite image data for efficient survey on the current condition of paved surface. We analysed the paved surface condition of Dae-jeon metropolitan city area using KOMPSAT-2 image and validate its practicalness and limitation of this method.

Application of a Watershed-Based Land Prioritization Model for the Protection of Drinking Water Reservoir (상수원 보호를 위한 유역기반 토지관리 우선순위 모델 적용)

  • Lee, Jee Hyun;Choi, Ji Yang;Park, Seok Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.397-408
    • /
    • 2004
  • Due to the growing impact of non-point source pollution and limitation of water treatment technology, a new policy of water quality management, called a source protection, is now becoming more important in drinking water supply. The source protection means that the public agency purchases the pollution sensitive area, such as riparian zone, and prohibit locations of point and non-point sources. Many studies have reported that this new policy is more economical in drinking water supply than the conventional one. However, it is very difficult to determine location and size of the pollution sensitive zone in the watershed. In this paper, we presented the scientific criteria for the priority of the pollution sensitive zone, along with a case study of the upstream watershed of the Paldang Reservoir, Han River. This study includes applications of the analytical hierarchy process(AHP) and a watershed-based land prioritization(WLP) model. After major criteria affecting water quality were selected, the AHP and geographic analysis were performed. The WLP model allowed us to include both quantity and quality criteria, using AHP as the multi-criteria method in making decision and reflecting local characteristics and various needs. By adding a travel-time function, which represents the prototype effectively, the results secured adaptability and scientific objectivity as well. As such, the WLP model appeared to provide reasonable criteria in determining the prioritization of land acquisition. If the tested data are used with a validated travel-time and AHP method is applied after further discussion among experts in such field, highly reliable results can be obtained.

The Effects of Welding Wires on the Weldabilities of API X-100 with Laser-Arc Hybrid Welidng (API X-100의 레이저-아크 하이브리드 용접성에 미치는 용접와이어의 영향)

  • Kim, Sungwook;Lee, Mok-Young
    • Journal of Welding and Joining
    • /
    • v.32 no.5
    • /
    • pp.7-12
    • /
    • 2014
  • In this study, API-X100 steel pipes were welded with various kinds of welding wires in the laser-arc hybrid welding process. 10kW fiber laser source was combined to MIG arc welding process. API X-100 steel of base metal was of 16.9mm thickness, and butt welding applied. After welding, full penetration weld was acquired by 1-pass welding. A root porosity and the lack of fusion was observed in some welding conditions. By the mixing the melted wire, acicular ferrite, polygonal ferrite, pro-eutectoid, aligned side plate, and bainite structures were observed at the weld metal. From the observation of hybrid weld, unmixed zone had more Ni and Cr. The unmixed zone was a 1/3 area of the weld metal. As the mechanical test of the hybrid welding, tensile test and impact test applied. From the tensile test, all of the welding except SM70S was fractured at the base metal. The result of the impact test at -30 degree C led 60J~320J of the absorbed energy. The result of the low-absorbed energy might be from the coarse equiaxed structures of the weld metal.

Environmental Planning Contermeasures Considering Spatial Distribution and Potential Factors of Particulate Matters Concentration (미세먼지 농도의 공간적 현황 및 잠재영향인자를 고려한 환경계획적 대응 방향)

  • Sung, Sun-Yong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.1
    • /
    • pp.89-96
    • /
    • 2020
  • Adverse impact of Particulate Matters(PM10, PM2.5; PMs) significantly affects daily lives. Major countermeasures for reducing concentration of PMs were focused on emission source without considering spatial difference of PMs concentration. Thus, this study analyzed spatial·temporal distribution of PMs with observation data as well as potential contributing factors on PMs concentration. The annual average concentration of PMs have been decreased while the particulate matter warnings and alerts were significantly increased in 2018. The average concentration of PMs in spring and winter was higher than the other seasons. Also, the spatial distribution of PMs were also showed seasonality while concentration of PMs were higher in Seoul-metropolitan areas in all seasons. Climate variables, emission source, spatial structure and potential PM sinks were selected major factors which could affects on ambient concentrations of PMs. This paper suggest that countermeasures for mitigating PM concentration should consider characteristics of area. Climatic variables(temperature, pressure, wind speed etc.) affects concentrations of PMs. The effects of spatial structure of cities(terrain, ventilation corridor) and biological sinks(green infrastructure, urban forests) on concentration of PMs should be analyzed in further studies. Also, seasonality of PMs concentration should be considered for establishing effective countermeasures to reduce ambient PMs concentration.