• Title/Summary/Keyword: Source and Impact Area

Search Result 207, Processing Time 0.025 seconds

A study on the Development of TCM Urban and Rural mode for Environmental Impact Assessment (환경영향평가를 위한 도시형과 교외형 TCM 개발에 관한 연구)

  • Jang, Young-Kee
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.1
    • /
    • pp.63-70
    • /
    • 1998
  • TCM has been used for many environmental impact assessments in Korea. But there was reported that an error was found in area source calculation of original TCM and modified. In this study, TUM(TCM-urban mode) and TRM(TCM-rural mode) were developed for urban and rural area by modification of original TCM. McElroy-Pooler dispersion parameter was used for area and point source in TUM, Pasquill-Gifford parameter was used for area and point source in TRM. And Irwin's vertical wind speed profile exponents were used for TUM and TRM. Then predicted value by TUM, TRM and a value from the same area and point data by CDM2, ISCLT3 were compared. And it was found that predicted value from point source by TUM, TRM was very similar to a value by CDM2, ISCLT3, and predicted value from area source by TRM was similar to a value by CDM2, ISCLT3. But predicted value from area: source by TUM was an half lower than a value by CDM2, ISCLT3.

  • PDF

External cost Forecasting of Virtual Point Source in Suwon Area Using Impact Pathway Analysis - A Comparison of Suwon to Paris - (영향경로해석을 이용한 수원시 가상 점오염원의 외부비용 예측 - 수원시와 파리시 비교분석을 중심으로 -)

  • Jeong, Sang Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.291-303
    • /
    • 2005
  • Impact pathway analysis(IPA) is a bottom-up approach to estimates health and environmental risks from emissions of classical pollutants (eg. $PM_{10}$, $SO_2$, $NO_x$ and CO). The model starts from the emission rates of facility, calculates the yearly mean concentrations of pollutants at the ground level using atmospheric dispersion models. After this, proper epidemiological exposure-response functions are applied to determine the impact on the receptors. Finally the methodology can monetise the calculated physical impact on the basis of selected economic evaluation. The aim of this study is to evaluate an external cost of virtual point source in Suwon area using IPA. The results shows minor modification of local input data can make it possible to apply the model to Suwon area.

Air Quality Impact Analysis of Point and Area Sources (점오염원과 면오염원의 대기환경영향 분석)

  • 김영성;손재익
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.168-173
    • /
    • 1993
  • Air quality impacts of point and area sources were analyzed by using ISCST2 with wind speed and stability class combinations of SCREEN. Stack height was important in determining the impact of point sources. With the stack height reduced to 21m from 75m, the concentration in the vicinity increased several times in spite of decreasing the emission rate by half. When the emission rates were same, concentrations from an area source of 10m release height were slightly lower than those from a point source of 21m stack height at the plume centerline. Bur the area source resulted in larger area of high concentration. Concentration from the point source was high in neutral to slightly unstable conditions with strong winds in a short distance, and in stable conditions with weak winds in a long distance. Concentration from the area source decreased with distance from the source, and was high in stable conditions with weak winds.

  • PDF

Stormwater Runoff Characteristics of Non-point Source Pollutants according to Landuse of Urban Area (도시지역 토지이용에 따른 비점원 오염물질 유출특성)

  • Jeong, Dong-Hwan;Shin, Dongseok;Rhew, Doughee;Jung, Dongil
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.6
    • /
    • pp.525-532
    • /
    • 2007
  • In order to establish and implement the total maximum daily load (TMDL) management plan in Korea, it is necessary to set the source units and calculate discharge loads for non-point source pollutants such as BOD, COD, SS, TN and TP. This study analysed the corelation between stormwater runoff characteristics and event mean concentrations (EMCs) of non-point source pollutants. As the result of the corelation analysis, we knew that all the antecedent dry days (ADD) and the rainfall correlated lowly with non-point source pollutants in the urban areas such as resident area, industrial area, business area, road area and parking area. Therefore, it is necessary to get all samples from stormwater starting point to stormwater ending point and standardize the sampling method of stormwater in order to obtain more accurate EMCs for landuse.

Determination of EMC and Washoff Characteristics of Stormwater Runoff from Broad-Leaved Forest Areas (산림 활엽수 지역의 강우유출수 유출특성 및 EMC 산정)

  • Kang, Chang Guk;Lee, Soyoung;Gorme, Joan Barniso;Lee, Jea Un;Kim, Lee-Hyung
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.393-399
    • /
    • 2009
  • The water of rivers and lakes are affecting by point and nonpoint source pollutions. The point source pollution can be controlled by establishing the treatment plants. However, nonpoint source pollution by various human activities is not easy to be controlled because it is difficult to determine the exits of the water flow and have many exit points. Due to contribution of nonpoint source pollution, the achievement ratio of water quality in rivers and lakes is not high. TMDL is the outstanding water quality control policy because all of the pollutant loadings from the watershed area are counting on the input loads. Our aqua-ecosystem has self-purification process by biological, physical and ecological processes. The self-purification process can remove the pollutant load from background concentrations. Usually forest area is main source of background concentrations. In Korea, about 70% of the national boundary area consists of mountains. This study is conducting as part of long-term monitoring to determine the Event Mean Concentration during a storm. The monitoring was performed on a broad-leaved tree area.

Characteristics of a Rubber-Ball Impactor to Evaluate Floor Impact Noise (바닥 충격음 평가를 위한 고무공 충격원의 특성)

  • 문형준;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.592-597
    • /
    • 2002
  • The purpose of this study was to analyze the characteristics of a new heavy weight impactor, the Rubber Ball. Until now Bang-machine has been used to measure the heavy impact noise in accordance with JIS A 1418-1. However, various kinds of examination methods have been needed to make an objective observation of insulation capacity for floor impact noises. Two types of experiments were undertaken. First, the experiment about noise was carried out about an apartment building in actual living condition. Then. vibration noises from the impactors were analyzed. The results of this study were as follows : the result of experiment carried out with bonded area of bail was closer to practical experiment than that of non bonded area. In addition, the result about bonded area of ball was more similar to the result which is claimed by H. Tachibana than that about non bonded area. Moreover, it was found that Rubber Ball has more similar vibration characteristics to the real impact noise source than Bang-machine.

  • PDF

Comparison Between the Dynamic Properties and Noise Isolation Performances for a Floor Impact Isolation Pad (바닥충격음 완충재의 동적특성과 소음저감 성능 비교)

  • Yang, Soo-Young;Lee, Dong-Hoon;Hong, Boung-Kuk;Song, Hwa-Young;Lee, Joo-Wone
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.275-278
    • /
    • 2005
  • In this study, the dynamic properties of a floor impact sound isolation pad expressed in terms of the natural frequency, the dynamic stiffness per unit area and the loss factor are measured by the resonant method. By using the measured dynamic properties, the vibration transmissibility diagram is obtained for each isolation pad, which is compared with the values tested by the impact sound sources at the room in an apartment. From the comparative results, it is found that the noise reduction Performances. of isolation pads are closely connected with the natural frequency and the dynamic stiffness per unit area.

  • PDF

Non-point Source Impact Analysis through Linkage of Watershed Model and River Water Quality Model (유역모형과 하천수질모형의 연계를 통한 비점오염원 영향분석)

  • Choi, Hyun Gu;Kim, Dong Il;Kim, Ji Eun;Han, Kun Yeun
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.1
    • /
    • pp.25-36
    • /
    • 2011
  • In this study, the accurate water quality analysis in rivers, including the non-point source is performed. First of all, watershed model, SWAT(Soil and Water Assessment Tool) was applied to analyze the impact of the non-point source in study area. And then, water quality analysis integrating the point source and the non-point source is implemented using QUALKO model. For more exact simulation, it should be the calibration and verification of variables and parameters which are needed for simulation. In addition, the importance of considering the non-point source was confirmed in river water quality simulation. BOD, TN, TP were analysed, and the results shows that BOD, TN and TP concentration was increased to 16.8%, 8.2% and 25.8% respectively. The more accurate estimate will be carried if use of reliable measurements and watershed simulation be done in models linking process. The suggested technique will improve the accuracy of the water quality analysis. The methodologies presented in this study will contribute to basin-wide water quantity and quality management.

A Study on Visibility Impairment Impact of the Plume from a Vast Point Source (거대 점 오염원의 플룸에 의한 시정 장애 효과 연구)

  • 배주현;김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.599-611
    • /
    • 1999
  • Now that the plume of point source was suspected to have strong impact on visibility impairment in Pusan, we evaluated visibility impairment impact of the pulme from Pusan Thermo Electric Power Plant in Pusan. Level-1 and-2 analyses were carried out using VISCREEN(Visual Impact Screen model). The emission rates for this Pusan Thermo Electric Power Plant was projected to be 116g/s of nitrogen oxides(as $NO_2$). The source fails the level-1 test with a Plume perceptibility(ΔE) of 30, nearly 15 times the screeing threshold. To characterize worstcase meteorological conditions for level-2 screening, we obtained meteorological data from Mar., 1996 to Feb., 1997 of Pusan Thermo Electric Power Plant. The source fails the level-2 test with a ΔE of 17, nearly 8.5 times the screening threshold. These analyses indicated that adverse visibility impairment could not be ruled out. Therefore a Level-3 analysis was performed using PLUVUE II(Plume Visibility model). As a result, maximum reduction of visual range for 0900LST in winter was 0.9%. Visual impact of the plume from vast point source was judged to be considerable in terms of background visibility of urban area.

  • PDF

The control of point and non-point source nitrogen to prevent eutrophication of the Nakdong River basin, Korea

  • Kwak, Sunggue;Yun, Zuwhan
    • Membrane and Water Treatment
    • /
    • v.11 no.5
    • /
    • pp.345-351
    • /
    • 2020
  • Eutrophication of surface waters is commonly caused by excessive inputs of nutrients such as nitrogen and phosphorus. Nakdong River basin was chosen as the study area to investigate the effect of point and non-point source pollution of nitrogen on eutrophication in water body. Non-point source inputs of nitrogen accounted for approximately 84% in the total nitrogen input of the upper Nakdong river watershed, which mainly consists of agricultural land and forests. However, point source inputs of nitrogen accounted for 58~85% in the total nitrogen input of the middle and lower watersheds, including urban area. Therefore, for watershed near urban area, control of point source inputs of nitrogen may be an optimal method to control eutrophication. In this respect, the enforcing reduction of nitrogen in the final effluent of wastewater treatment facilities is needed. On the other hand, to enact more stringent nitrogen regulations, the LOT (limit of technology) and environmental impact should be considered. In this study nitrogen data were analyzed to propose new nitrogen regulations.