• Title/Summary/Keyword: Source Tracking

Search Result 329, Processing Time 0.022 seconds

Self-Powered Solar Tracker System without CPU (CPU 없는 자가 동력 태양광 트랙커 시스템)

  • Lee, Jae Jin;Choi, Woo Jin;Kim, Seok-Min;Park, Joon Young;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.211-218
    • /
    • 2017
  • This paper proposes the self-powered solar tracker system without CPU. Conventional solar tracker system occurs the problem of cost and durability because of using CPU. In addition, this system has effects from installation site and environment. The proposed solar tracker system without CPU is possible to achieve the high efficiency because it tracks the maximum of the light source. The validity of proposed solar tracking system is verified with experiment results.

Performance Analysis and Evaluation of 3kW Grid-Connected PV Systems (3kW급 계통연계형 태양광발전시스템의 성능특성 평가분석)

  • So, Jung-Hun;Jung, Young-Seok;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.8
    • /
    • pp.509-516
    • /
    • 2004
  • The concerns of distributed generations including photovoltaic(PV) system have been increased around the world since PV system is becoming widespread as a clean and gentle energy source for earth. In the future high density grid-connected PV systems will be interconnected with distribution network. As a result, the stability and long-term reliability of PV systems have become more important issues in this area. Grid-connected PV systems have been installed and monitored at field demonstration test center(FDTC) and also data acquisition system(DAS) has been constructed for measuring and analyzing performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV system has been evaluated and analyzed for component perspective (PV array and power conditioning system) and global perspective (system efficiency, capacity factor, and electrical power energy) by field test and loss factors of PV system.

System Phase Noise for Mobile Satellite Communication Service (이동형 위성통신 서비스를 위한 시스템 위상 잡음)

  • Kim Young-wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.8
    • /
    • pp.1780-1786
    • /
    • 2005
  • The phase error generated in the transmission system affects the performance of digital transmission signal. The phase error are generated by random phase noise and tracking phase error due to denier phenomenon. In the mobile satellite communication system that generates the doppler frequency, which is a system with a movement, the proper system phase noise spectrum should be designed based on analyses for phase noise and static phase error effects. Based on the analyses of the doppler frequency and the phase error for bilateral satellite communication system providing an asynchronous service, the phase noise spectrums for the mobile satellite communication are designed in this paper. Also, the available transmission services under the less doppler effect are proposed and the proper signal source units for a required transmission system can be designed under the proposed system phase noise spectrum.

The Bearing Estimation of Narrowband Acoustic Signals Using DIFAR Beamforming Algorithm (DIFAR 빔형성 알고리듬을 이용한 협대역 음향신호의 방향성 추정)

  • 장덕홍;박홍배;정문섭;김인수
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.169-184
    • /
    • 2002
  • In order to extract bearing information from the directional sensors of DIFAR(directional frequency analysis and recording) that is a kind of passive sonobuoy, the cardioid beamforming algorithm applicable to DIFAR system was studied in the frequency domain. the algorithm uses narrow-band signals propagated though the media from the acoustic sources such as ship machineries. The proposed algorithm is expected to give signal to noise ratio of 6dB when it uses the maximum response axis(MRA) among the Cardioid beams. The estimated bearings agree very well with those from GPS data. Assuming the bearings from GPS data to be real values, the estimation errors are analyzed statistically. The histogram of estimation errors in each frequency have Gaussian shape, the mean and standard deviation dropping in the ranges -1.1~$6.7^{\circ}$ and 13.3~$43.6^{\circ}$, respectively. Estimation errors are caused by SMR degradation due to propagation loss between the source and receiver, daily fluctuating geo-magnetic fields, and non-stationary background noises. If multiple DIFAR systems are employed, in addition to bearing, range information could be estimated and finally localization or tracking of a target is possible.

A study on Photovoltaic System to Considers a Solar Position Tracker for Air Conditioner a Clinic room (병실 냉.난방장치용 태양 위치 추적기를 이용한 태양광 발전시스템에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1355-1362
    • /
    • 2007
  • In this paper, these setting can be useful in the microprocessor and sensor that designed to improve the efficiency of the photovoltaic system the photovoltaic position tracker device, and compared the normal photovoltaic system of fixed form with the photovoltaic system of solar position tracked form. Moreover, this is compared the catalogue of solar cell module and the simulation through a mathematics modelling with the solar cell's characteristic interpreting and that is composed an power conversion system with boost converter and voltage source inverter. This device can be used to the constant voltage control method for maximum power point tracking in boost converter control. Experiment Results is shown that using a SPWM(Sinusoidal Pulse Width Modulation) control method in inverter control.

  • PDF

Robust DTC Control of Doubly-Fed Induction Machines Based on Input-Output Feedback Linearization Using Recurrent Neural Networks

  • Payam, Amir Farrokh;Hashemnia, Mohammad Naser;Fai, Jawad
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.719-725
    • /
    • 2011
  • This paper describes a novel Direct Torque Control (DTC) method for adjustable speed Doubly-Fed Induction Machine (DFIM) drives which is supplied by a two-level Space Vector Modulation (SVM) voltage source inverter (DTC-SVM) in the rotor circuit. The inverter reference voltage vector is obtained by using input-output feedback linearization control and a DFIM model in the stator a-b axes reference frame with stator currents and rotor fluxes as state variables. Moreover, to make this nonlinear controller stable and robust to most varying electrical parameter uncertainties, a two layer recurrent Artificial Neural Network (ANN) is used to estimate a certain function which shows the machine lumped uncertainty. The overall system stability is proved by the Lyapunov theorem. It is shown that the torque and flux tracking errors as well as the updated weights of the ANN are uniformly ultimately bounded. Finally, effectiveness of the proposed control approach is shown by computer simulation results.

Suspended Solid Dispersion Analysis for Coastal Areas Using Hybrid Concept of Particle and Concentration of Eulerian-Lagrangian Model (Eulerian-Lagrangian 농도 및 입자 결합모형에 의한 연안의 부유사 확산해석)

  • 서승원
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.8 no.2
    • /
    • pp.185-192
    • /
    • 1996
  • In order to simulate the coastal dispersion effectively, hybrid concept of operator split Eulerian-lagrangian concentration model and random-walk particle tracking model are developed. Especially the random-walk model is adequate for region with steep slope of concentration. According to model tests, it agrees perfectly with analytical solution on around the source point for therefore. ▽C $\geq$ 0.005, meanwhile it shows poor results for ▽C$\leq$0.002. trial modeling for real situation therefore, random-walk model is applied for near field henceforth Eulerian-Lagrangian concentration model is adoped for whole domain so that overall performance and accuracy can be achieved by using developed hybrid model.

  • PDF

A Simple Power Management Scheme with Enhanced Stability for a Solar PV/Wind/Fuel Cell Fed Standalone Hybrid Power Supply using Embedded and Neural Network Controller

  • Thangavel, S.;Saravanan, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1454-1470
    • /
    • 2014
  • This paper propose a new power conditioner topology with intelligent power management controller that integrates multiple renewable energy sources such as solar energy, wind energy and fuel cell energy with battery backup to make best use of their operating characteristics and obtain better reliability than that could be obtained by single renewable energy based power supply. The proposed embedded controller is programmed for maintaining a constant voltage at PCC, maximum power point tracking for solar PV panel and WTG and power flow control by regulating the reference currents of the controller on instantaneous basis based on the power delivered by the sources and load demand. Instantaneous variation in reference currents of the controller enhances the controller response as it accommodates the effect of continuously varying solar insolation and wind speed in the power management. The power conditioner uses a battery bank with embedded controller based online SOC estimation and battery charging system to suitably sink or source the input power based on the load demand. The simulation results of the proposed power management system for a standalone solar/WTG/fuel cell fed hybrid power supply with real time solar radiation and wind velocity data collected from solar centre, KEC for a sporadically varying load demand is presented in this paper and the results are encouraging in reliability and stability perspective.

A Scheme to Support IP Mobility over Wireless ATM Networks (무선 ATM망에서 이동성 지원 기법)

  • 문영성;김영욱
    • Journal of KIISE:Information Networking
    • /
    • v.30 no.5
    • /
    • pp.573-580
    • /
    • 2003
  • Increasing user demand for the more bandwidths in wireless communications has motivated a new challenge to utilize the benefits of wireless ATM technology This paper focuses on how to provide IP services to a mobile user over wireless ATM networks. By enhancing the NHRP standard, several shortcomings are improved that are resulted from the naive combinations of Mobile IP over ATM and IP over wireless ATM. This paper presents a mobile location management algorithm that is referred to as the Mobile NHRP scheme. The mobile tracking procedure and the mobile locating procedure are explicitly defined in the proposed scheme. On the locating procedure, the source station may obtain the current location of the destination from NHSs(Next Hop Servers). Therefore the optimized connection can be setup directly. The total costs per move and per setup over ATM/IP overlaid networks are estimated.

A Single-Source Photovoltaic Power Conditioning System using Forward-Flyback converter and Asymmetric cascaded Multi Level H-bridge Inverter (포워드-플라이백 컨버터와 단일 전원 비대칭 다단식 H-bridge 다중 레벨 인버터를 적용한 태양광 전력 조절 시스템)

  • Jeon, Young-tae;Sundar, Mohana;Park, Joung-Hu
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.73-74
    • /
    • 2016
  • 본 논문은 포워드-플라이백 컨버터와 태양광 단일 전원 비대칭 다단식 H-bridge 다중 레벨 인버터를 적용한 태양광 전력 조절 시스템에 관한 논문이다. 이는 기존에 연구되었던 대칭형 다단식 H-Brdige 다중 레벨 인버터나 플라이백 컨버터를 사용한 태양광 전력 조절 시스템의 단점을 보완 한 것이다. 대칭형 다단식 멀티 레벨 인버터는 각 H-Bridge 구조 마다 독립된 전원이 필요하지만, 포워드-플라이백(Foward-Flyback) 컨버터를 접목시켜 단일 태양광 전원으로 하나의 다단식 H-Brdige 인버터를 구성 할 수 있고, 또한 기존의 플라이백 컨버터를 포워드-플라이백 컨버터로 대체 하면서 기존 대비 대용량 설비가 용이하고 효율적인 태양광 전력 조절 시스템을 설계 할 수 있다. 제안한 시스템의 가능성을 확인하기 위하여, PSIM 시뮬레이션을 통해 계통 연계형 1kW급 태양광 시스템의 최대 전력 추종 제어(Maximum Power Point Tracking)와 인버터의 $V_{dc}$ 전압 제어를 확인하였다.

  • PDF