• Title/Summary/Keyword: Source Imaging

Search Result 545, Processing Time 0.027 seconds

The development of a fully automated homemade system for [11C] acetate synthesis using an open source PLC

  • Kang, Se Hun;Hong, Sung Tack;Park, Kwangseo;Kim, Seok-ki
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.2
    • /
    • pp.103-107
    • /
    • 2016
  • Solid phase extraction (SPE) purification method is the efficient and well-known tool for automated [$^{11}C$]acetate synthesis. A fully automated homemade module adopting the SPE method and 'pinch' valves was developed very economically with a universal interface board, a relay card and an open source programmable logic controller. The radiochemical yield of the optimized [$^{11}C$]acetate synthesis by this system was $58.8{\pm}2.1%$ (n=10, decay-corrected) from $15.5{\pm}0.19GBq$ of $[^{11}C]CO_2$ as starting activity, and total synthetic time was 15 minutes. HPLC analysis showed its high radiochemical purity as $97.4{\pm}1.1%$ without possible by-products.

EXPERIMENTAL DEMONSTRATION OF ADVANTAGE OF MOTION INDUCED SYNTHETIC APERTURE RADIOMETER

  • Park, Hyuk;Kim, Sung-Hyun;Lee, Ho-Jin;Moon, Nam-Won;Yu, Hwan-Wook;NamGoong, Up;Sim, Won-Seon;Kim, Yong-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.22-25
    • /
    • 2008
  • Aperture synthesis with platform motion has been presented as a useful tool to achieve the high spatial resolution imaging. Using a motion induced synthetic aperture radiometer (MISAR), a passive microwave image can be achieved with a small number of antennas. Moreover, the MISAR is capable of imaging better than the case without motion, using the same configuration of antenna array. With a platform motion, visibility can be sampled more efficiently, and as a result the imaging performance of the MISAR shows higher quality than the case without platform motion. In this paper, the advantage of MISAR is demonstrated experimentally. Using a laboratory model of inteferometric radiometer, the point source images are obtained under the condition with platform motion and without platform motion. In the experimental results, the point source response of the MISAR shows better quality of sidelobe level and beam efficiency than the case without platform motion.

  • PDF

Characteristics Evaluation of the Lens for Underwater Acoustic Imaging (수중음향 영상화를 위한 렌즈 제작 및 특성 평가)

  • Cho, Wan-Ho;Kwon, Hyu-Sang;Cho, Yo-Han;Seo, Hee-Seon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.6_spc
    • /
    • pp.687-696
    • /
    • 2016
  • A series of process to design an acoustic lens for underwater imaging is reviewed and the method to evaluate characteristics of the lens is investigated. If the target specification of lens is given, the design process consists of the material selection, evaluation of its properties, lens geometry design, prediction of lens characteristics, manufacturing, and evaluation by measurement. In this study, an actual acoustical lens is made by cutting polymethylpentene block. The characteristics of lens are predicted by the hybrid method, combination of ray tracing and Rayleigh integral. For the direct comparison between the prediction and measurement results, a simulation method based on the equivalent source method is suggested to reflect the actual radiation pattern of transducer used for measurements. Finally, the measurement is conducted in a small water tank to observe the actual characteristics of the manufactured lens.

Performance evaluation of an adjustable gantry PET (AGPET) for small animal PET imaging

  • Song, Hankyeol;Kang, In Soo;Kim, Kyu Bom;Park, Chanwoo;Baek, Min Kyu;Lee, Seongyeon;Chung, Yong Hyun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2646-2651
    • /
    • 2021
  • A rectangular-shaped PET system with an adjustable gantry (AGPET) has been developed for imaging small animals. The AGPET system employs a new depth of interaction (DOI) method using a depth dependent reflector patterns and a new digital time pickoff method based on the pulse reconstruction method. To evaluate the performance of the AGPET, timing resolution, intrinsic spatial resolution and point source images were acquired. The timing resolution and intrinsic spatial resolution were measured using two detector modules and Na-22 gamma source. The PET images were acquired in two field of view (FOV) sizes, 30 mm and 90 mm, to demonstrate the characteristic of the AGPET. As a result of in the experiment results, the timing resolution was 0.9 ns using the pulse reconstruction method based on the bi-exponential model. The intrinsic spatial resolution was an average of 1.7 mm and the spatial resolution of PET images after DOI correction was 2.08 mm and 2.25 mm at the centers of 30 mm and 90 mm FOV, respectively. The results show that the proposed AGPET system provided higher sensitivity and resolution for small animal imaging.

Gaussian Model for Laser Image on Curved Surface

  • Annmarie Grant;Sy-Hung Bach;Soo-Yeong Yi
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.701-707
    • /
    • 2023
  • In laser imaging, accurate extraction of the laser's center is essential. Several methods exist to extract the laser's center in an image, such as the geometric mean, the parabolic curve fitting, and the Gaussian curve fitting, etc. The Gaussian curve fitting is the most suitable because it is based on the physical properties of the laser. The width of the Gaussian laser beam depends on the distance from the laser source to the target object. It is assumed in general that the distance remains constant at a laser spot resulting in a symmetric Gaussian model for the laser image. However, on a curved surface of the object, the distance is not constant; The laser beam is narrower on the side closer to the focal point of the laser light and wider on the side closer to the laser source, which causes the distribution of the laser beam to skew. This study presents a modified Gaussian model in the laser imaging to incorporate the slant angle of a curved object. The proposed method is verified with simulation and experiments.

Functional beamforming for high-resolution ultrasound imaging in the air with random sparse array transducer (고해상도 공기중 초음파 영상을 위한 기능성 빔형성법 적용)

  • Choon-Su Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.361-367
    • /
    • 2024
  • Ultrasound in the air is widely used in industry as a measurement technique to prevent abnormalities in the machinery. Recently, the use of airborne ultrasound imaging techniques, which can find the location of abnormalities using an array transducers, is increasing. A beamforming method that uses the phase difference for each sensor is used to visualize the location of the ultrasonic sound source. We exploit a random sparse ultrasonic array and obtain beamforming power distribution on the source in a certain distance away from the array. Conventional beamforming methods inevitably have limited spatial resolution depending on the number of sensors used and the aperture size. A high-resolution ultrasound imaging technique was implemented by applying functional beamforming as a method to overcome the geometric constraints of the array. The functional beamforming method can be expressed as a generalized beam forming method mathematically, and has the advantage of being able to obtain high-resolution imaging by reducing main-lobe width and side lobes. As a result of observation through computer simulation, it was verified that the resolution of the ultrasonic source in the air was successfully increased by functional beamforming using the ultrasonic sparse array.

A Volume Reconstruction Algorithm and a Coordinate Calibration of an X-ray Three Dimensional Imaging System

  • Roh, Young-Jun;Cho, Hyung-Suck;Jeon, Hyoung-Jo;Kim, Hyeong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.63.3-63
    • /
    • 2001
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. In this paper, we propose a three dimensional volume reconstruction method, which is an iterative method and as uniform and simulated algebraic reconstruction technique (USART). In this method, two or more x-ray images projected from different views are needed, and also the geometry of the imaging system need to be a priori identified well. That is to say, the relative locations between the x-ray source, imaging plane and the object should be determined exactly by calibration. To achieve this, we propose a series of coordinate calibration methods of the x-ray imaging system using grid pattern images. Some experimental results of these calibrations is presented and discussed in detail ...

  • PDF

Imaging of seismic sources by time-reversed wave propagation with staggered-grid finite-difference method (지진원 영상화를 위한 엇갈린 격자 유한 차분법을 이용한 지진파 역행 전파 모의)

  • Sheen, Dong-Hoon;Hwang, Eui-Hong;Ryoo, Yong-Gyu;Youn, Yong-Hoon
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.25-32
    • /
    • 2006
  • We present a imaging method of seismic sources by time reversal propagation of seismic waves. Time-reversal wave propagation is actively used in medical imaging, non destructive testing and waveform tomography. Time-reversal wave propagation is based on the time-reversal invariance and the spatial reciprocity of the wave equation. A signal is recorded by an array of receivers, time-reversed and then back-propagated into the medium. The time-reversed signal propagates back into the same medium and the energy refocuses back at the source location. The increasing power of computers and numerical methods makes it possible to simulate more accurately the propagation of seismic waves in heterogenous media. In this work, a staggered-grid finite-difference solution of the elastic wave equation is employed for the wave propagation simulation. With numerical experiments, we show that the time-reversal imaging will enable us to explore the spatio-temporal history of complex earthquake.

  • PDF

Unwanted effects due to interactions between dental materials and magnetic resonance imaging: a review of the literature

  • Chockattu, Sherin Jose;Suryakant, Deepak Byathnal;Thakur, Sophia
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.4
    • /
    • pp.39.1-39.20
    • /
    • 2018
  • Magnetic resonance imaging (MRI) is an advanced diagnostic tool used in both medicine and dentistry. Since it functions based on a strong uniform static magnetic field and radiofrequency pulses, it is advantageous over imaging techniques that rely on ionizing radiation. Unfortunately, the magnetic field and radiofrequency pulses generated within the magnetic resonance imager interact unfavorably with dental materials that have magnetic properties. This leads to unwanted effects such as artifact formation, heat generation, and mechanical displacement. These are a potential source of damage to the oral tissue surrounding the affected dental materials. This review aims to compile, based on the current available evidence, recommendations for dentists and radiologists regarding the safety and appropriate management of dental materials during MRI in patients with orthodontic appliances, maxillofacial prostheses, dental implants, direct and indirect restorative materials, and endodontic materials.

Wavefront Folding Interferometer for 3-dimensional Coherence Imaging (3 차원 결맞음 결상을 위한 파면 접힘 간섭계)

  • Oh, Se-Baek;Hong, Young-Joo;Kwak, Yoon-Keun;Kim, Soo-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.755-759
    • /
    • 2004
  • The van Cittert-Zernike theorem has been used in radio astronomy. Recently, the van Cittert-Zernike theorem has been tried to 3D source reconstruction. A couple of interferometer has been used in 3D coherence imaging like Michelson Stellar Interferometer and Rotational Shearing Interferometer. We propose a new type of interferometer, which is a wavefront folding interferometer with a corner cube. By characteristics of the corner cube, it is capable of measuring both mutual intensity and cross spectral density function, and it is very easy to align and robust to disturbance. We simulate the feasibility of this interferometer setup by simulation of point source reconstruction.

  • PDF