• Title/Summary/Keyword: Source Imaging

검색결과 545건 처리시간 0.025초

Comparison of the Effect of the Interpolation Function on the Performance of the Noise Source Imaging Technology (소음원 영상화 기술의 성능에 보간 함수가 미치는 영향 비교)

  • Park, Kyu-Chil;Yoon, Jong Rak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제20권2호
    • /
    • pp.268-274
    • /
    • 2016
  • To find the location of a random noise source present in the three-dimensional space is required at least four microphones. Using four microphones distributed in a three-dimensional space, noise source imaging technique was applied and evaluated on their performance. To compensate resolution problem which comes from both the position of the sensor array is fixed and the sampling frequency is low, up-sampling technique and interpolation function were applied. Five different interpolation methods were applied such as zero-padding, zero-order hold, first-order hold, spline function, and random signal padding. The up-sampling rate were chosen by two, four, eight times, and counting up 16 times. As a result, it was possible to more accurately estimate the position of the noise source according to the higher of the up-sampling rate. It also found that the first-order hold and the spline function's performance were slightly falling relative to other methods.

An Isothermal Temperature Source with a Large Surface Area using the Metal-Etched Microwick-Inserted Vapor Chamber Heat Spreader

  • Go, Jeong-Sang;Kim, Kyung-Chun
    • Journal of Mechanical Science and Technology
    • /
    • 제18권4호
    • /
    • pp.681-688
    • /
    • 2004
  • For use of the thermal cycle of the biochemical fluid sample, the isothermal temperature source with a large surface area was designed, fabricated and its thermal characterization was experimentally evaluated. The comprehensive overview of the technology trend on the temperature control devices was detailed. The large surface area isothermal temperature source was realized by using the vapor chamber heat spreader. The cost-effectiveness and simple manufacturing process were achieved by using the metal-etched wick structure. The temperature distribution was quantitatively investigated by using IR temperature imaging system at equivalent temperatures to the PCR thermal cycle. The standard deviation was measured to be within 0.7$^{\circ}C$ for each temperature cycle. This concludes that the presented isothermal temperature source enables no temperature gradient inside bio-sample fluid. Furthermore it can be applied to the cooling of the electronic devices due to its slimness and low thermal spreading resistance.

Determination of Impact Source Location Using a Single Transducer and Time Reversal Technique (단일센서와 시간역전법을 이용한 판에서의 충격위치 결정에 관한 연구)

  • Jeong, Hyun-Jo;Cho, Sung-Jong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제32권1호
    • /
    • pp.47-55
    • /
    • 2012
  • A structural health monitoring technique for locating impact position in a plate structure is presented in this paper. The method employs a single sensor and spatial focusing of time reversal (TR) acoustics. We first examine the TR focusing effect at the impact position and its surroundings through simulation and experiment. The imaging results of impact points show that the impact source location can be accurately estimated in any position of the plate. Compared to existing techniques for locating impact or acoustic emission source, the proposed method has the benefits of using a single sensor and not requiring material properties and geometry of structures. Furthermore, it does not depend on a particular mode of dispersive Lamb waves that is frequently used in other ultrasonic testings of plate-like structures.

Fringe Sensitivity of Projection Moire Topography Due to Position of Light Source and Object Distance According to Grating Periods (영사식 무아레 토포그래피에서 격자 주기에 따른 물체거리와 광원의 위치에 대한 무늬 민감도 변화)

  • Oh, Hyun Seock;Ju, Yun Jae;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • 제27권2호
    • /
    • pp.67-72
    • /
    • 2016
  • In projection moire topography, the investigation of fringe sensitivity, which means the change rate of fringe order according to object height, is important and necessary to reduce the measurement error of the shape of an object. Using the fringe sensitivity, the determination of the absolute orders of moire fringes can be performed very easily and rapidly. The important parameters in the determination of absolute orders of fringes are the positions of light source and object, and the grating period in projection moire topography. Among these parameters, the fringe sensitivity due to the transverse motion of the light source and the longitudinal motion of the object according to grating periods are analyzed and compared. As a result, whereas the fringe sensitivity in the transverse-motion method increases linearly and gradually as the distance between light source and imaging sensor increases, the fringe sensitivity due to the longitudinal-motion method decreases dramatically as the distance between imaging lens and object increases. In these methods, the fringe sensitivity and its change increase as the grating period increases.

Development of the Program for Reconnaissance and Exploratory Drones based on Open Source (오픈 소스 기반의 정찰 및 탐색용 드론 프로그램 개발)

  • Chae, Bum-sug;Kim, Jung-hwan
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • 제17권1호
    • /
    • pp.33-40
    • /
    • 2022
  • With the recent increase in the development of military drones, they are adopted and used as the combat system of battalion level or higher. However, it is difficult to use drones that can be used in battles below the platoon level due to the current conditions for the formation of units in the Korean military. In this paper, therefore, we developed a program drones equipped with a thermal imaging camera and LiDAR sensor for reconnaissance and exploration that can be applied in battles below the platoon level. Using these drones, we studied the possibility and feasibility of drones for small-scale combats that can find hidden enemies, search for an appropriate detour through image processing and conduct reconnaissance and search for battlefields, hiding and cover-up through image processing. In addition to the purpose of using the proposed drone to search for an enemies lying in ambush in the battlefield, it can be used as a function to check the optimal movement path when a combat unit is moving, or as a function to check the optimal place for cover-up or hiding. In particular, it is possible to check another route other than the route recommended by the program because the features of the terrain can be checked from various viewpoints through 3D modeling. We verified the possiblity of flying by designing and assembling in a form of adding LiDAR and thermal imaging camera module to a drone assembled based on racing drone parts, which are open source hardware, and developed autonomous flight and search functions which can be used even by non-professional drone operators based on open source software, and then installed them to verify their feasibility.

Analysis of Image Quality According to Imaging Parameters in Digital Tomosynthesis (디지털 단층영상합성장치의 영상획득 조건에 따른 화질 분석)

  • Lee, Dahye;Lee, Seungwan;Kim, Burnyoung;Yim, Dobin;Nam, Kibok;Cho, Jeonghyo
    • Journal of the Korean Society of Radiology
    • /
    • 제14권4호
    • /
    • pp.477-486
    • /
    • 2020
  • The purpose of this study was to evaluate the effects of reconstruction filters, X-ray source trajectories and intervals in the quality of digital tomosynthesis (DT) images, and the results was clinically validated. The filtered back-projection was implemented by using Ramp, Shepp-Logan, Cosine, Hamming, Hann and Blackman filters, and the X-ray source trajectories were simulated with 1 × 36, 2 × 18, 3 × 12, 4 × 9 and 6 × 6 arrays. The X-ray source intervals were 5, 10, 20, 30 and 40 mm. The depth resolution, spatial resolution and noise of DT image were evaluated by measuring artifact spread function (ASF), full width at half maximum (FWHM) and signal-to-noise ratio (SNR), respectively. The results showed that the spatial resolution and noise properties of DT images were maximized by the Ramp and Blackman filters, respectively, and the depth resolution and noise properties of the DT images obtained with a 1 × 36 X-ray source trajectory were superior to the other trajectories. The depth resolution and noise properties of DT images improved with an increase of X-ray source intervals, and the high X-ray source intervals degraded the spatial resolution of DT images. Therefore, the characteristics of DT images are highly dependent on reconstruction filters, X-ray source trajectories and intervals, and it is necessary to use optimal imaging parameters in accordance with diagnostic purpose.

Fluorescence Molecular Imaging

  • Choi, Heung-Kook;Ntziachristos, Vasilis;Weissleder, Ralph
    • Proceedings of the KSMRM Conference
    • /
    • 대한자기공명의과학회 2004년도 제9차 학술대회 초록집
    • /
    • pp.23-32
    • /
    • 2004
  • The chemotherapy sensitive Lewis lung carcinoma (LLC) and chemotherapy resistant Lewis lung carcinoma (CR-LLC) tumors concurrently implanted in mice, and compare these findings with histological macroscopic observations against 3D reconstruction of Fluorescence Molecular Tomography (FMT) preformed in vivo on the same animals. For the 3D image reconstruction we used 32 laser source images, a flat image and 3D surface rendering that confused for 3D Fluorescence Molecular Imaging (FMI). A minimum of ten tissue sections were analyzed per tumor for quantification of the TUNEL-positive cells, cell-associated Cy5.5-Annexin and vessel-associated Alexa Fluor-Lectin. These are useful apoptosis and angiogenesis markers, and they serve as validation experiments to data obtained in vivousing a Cy5.5-Annexin V conjugate injected intravenously in chemotherapy-treated animals carrying the tumors studied histologically. We detected higher levels of apoptosis and corresponding higher levels of Cy5.5 fluorescence in the LLC vs. the CR-LLC tumors according to tissue depth and these findings confirm that in vivo staining with the Cy5.5-Annexing conjugate correlates well with in vitro TUNEL staining and is consistent with the higher apoptotic index expected from the LLC line. There appeared to be 1.38% more apoptosis for LLC than CR-LLC. Consequently there is good correlation between the histology results and in vivo fluorescence-mediated optical imaging. In conclusion the apoptotic images of 3D FMI were validated by microscopic histological image analysis. This is a significant result for the continuous progress of fluorescence 3D imaging research.

  • PDF

SYSTEM ANALYSIS OF PIPELINE SOFTWARE - A CASE STUDY OF THE IMAGING SURVEY AT ESO

  • Kim, Young-Soo
    • Journal of Astronomy and Space Sciences
    • /
    • 제20권4호
    • /
    • pp.403-416
    • /
    • 2003
  • There are common features, in both imaging surveys and image processing, between astronomical observations and remote sensing. Handling large amounts of data, in an easy and fast way, has become a common issue. Implementing pipeline software can be a solution to the problem, one which allows the processing of various kinds of data automatically. As a case study, the development of pipeline software for the EIS (European Southern Observatory Imaging Survey) is introduced. The EIS team has been conducting a sky survey to provide candidate targets to the 250 VLTs (Very Large Telescopes) observations. The survey data have been processed in a sequence of five major data corrections and reductions, i.e. preprocessing, flat fielding, photometric and astrometric corrections, source extraction, and coaddition. The processed data are eventually distributed to the users. In order to provide automatic processing of the vast volume of observed data, pipeline software has been developed. Because of the complexity of objects and different characteristic of each process, it was necessary to analyze the whole works of the EIS survey program. The overall tasks of the EIS are identified, and the scheme of the EIS pipeline software is defined. The system structure and the processes are presented, and in-depth flow charts are analyzed. During the analyses, it was revealed that handling the data flow and managing the database are important for the data processing. These analyses may also be applied to many other fields which require image processing.

Performance Analysis of the Inversion Schemes in the Spotlight-mode SAR(Synthetic Aperture Radar) (Spotlight-mode SAR(Synthetic Aperture Radar)에서의 Inversion 기법 성능 분석)

  • 최정희
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • 제40권1호
    • /
    • pp.130-138
    • /
    • 2003
  • The classical image reconstruction for stripmap-mode Synthetic Aperture Radar is the Range-Doppler algorithm. When the spotlight-mode SAR system was envisioned, Range-Doppler algorithm turned out to fail rapidly in this SAR imaging modality. Thus, what is referred to as Polar format algorithm, which is based on the Plane wave approximation, was introduced for imaging from spotlight-mode SAR raw- data. In this paper, we have studied for the raw data processing schemes in the spotlight-mode Synthetic Aperture Radar. We apply the Wavefront Reconstruction scheme that does not utilize the approximation in spotlight-mode SAR imaging modelity, and compare the performance of target imaging with the Polar format inversion scheme.

Detection Algorithm for Cracks on the Surface of Tomatoes using Multispectral Vis/NIR Reflectance Imagery

  • Jeong, Danhee;Kim, Moon S.;Lee, Hoonsoo;Lee, Hoyoung;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제38권3호
    • /
    • pp.199-207
    • /
    • 2013
  • Purpose: Tomatoes, an important agricultural product in fresh-cut markets, are sometimes a source of foodborne illness, mainly Salmonella spp. Growth cracks on tomatoes can be a pathway for bacteria, so its detection prior to consumption is important for public health. In this study, multispectral Visible/Near-Infrared (NIR) reflectance imaging techniques were used to determine optimal wavebands for the classification of defect tomatoes. Methods: Hyperspectral reflectance images were collected from samples of naturally cracked tomatoes. To classify the resulting images, the selected wavelength bands were subjected to two-band permutations, and a supervised classification method was used. Results: The results showed that two optimal wavelengths, 713.8 nm and 718.6 nm, could be used to identify cracked spots on tomato surfaces with a correct classification rate of 91.1%. The result indicates that multispectral reflectance imaging with optimized wavebands from hyperspectral images is an effective technique for the classification of defective tomatoes. Conclusions: Although it can be susceptible to specular interference, the multispectral reflectance imaging is an appropriate method for commercial applications because it is faster and much less expensive than Near-Infrared or fluorescence imaging techniques.