• 제목/요약/키워드: Source Calibration

검색결과 385건 처리시간 0.027초

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • 제5권2호
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

Drilling Gas Hydrate at Hydrate Ridge, ODP Leg 204

  • 이영주;류병재;김지훈;이상일
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.663-666
    • /
    • 2005
  • Gas hydrates are ice-like compounds that form at the low temperature and high pressure conditions common in shallow marine sediments at water depths greater than 300-500 m when concentrations of methane and other hydrocarbon gases exceed saturation. Estimates of the total mass of methane carbon that resides in this reservoir vary widely. While there is general agreement that gas hydrate is a significant component of the global near-surface carbon budget, there is considerable controversy about whether it has the potential to be a major source of fossil fuel in the future and whether periods of global climate change in the past can be attributed to destabilization of this reservoir. Also essentially unknown is the interaction between gas hydrate and the subsurface biosphere. ODP Leg 204 was designed to address these questions by determining the distribution, amount and rate of formation of gas hydrate within an accretionary ridge and adjacent basin and the sources of gas for forming hydrate. Additional objectives included identification of geologic proxies for past gas hydrate occurrence and calibration of remote sensing techniques to quantify the in situ amount of gas hydrate that can be used to improve estimates where no boreholes exist. Leg 204 also provided an opportunity to test several new techniques for sampling, preserving and measuring gas hydrates. During ODP Leg 204, nine sites were drilled and cored on southern Hydrate Ridge, a topographic high in the accretionary complex of the Cascadia subduction zone, located approximately 80km west of Newport, Oregon. Previous studies of southern Hydrate Ridge had documented the presence of seafloor gas vents, outcrops of massive gas hydrate, and a pinnacle' of authigenic carbonate near the summit. Deep-towed sidescan data show an approximately $300\times500m$ area of relatively high acoustic backscatter that indicates the extent of seafloor venting. Elsewhere on southern Hydrate Ridge, the seafloor is covered with low reflectivity sediment, but the presence of a regional bottom-simulating seismic reflection (BSR) suggests that gas hydrate is widespread. The sites that were drilled and cored during ODP Leg 204 can be grouped into three end-member environments basedon the seismic data. Sites 1244 through 1247 characterize the flanks of southern Hydrate Ridge. Sites 1248-1250 characterize the summit in the region of active seafloor venting. Sites 1251 and 1252 characterize the slope basin east of Hydrate Ridge, which is a region of rapid sedimentation, in contrast to the erosional environment of Hydrate Ridge. Site 1252 was located on the flank of a secondary anticline and is the only site where no BSR is observed.

  • PDF

가변 페브리-페로 필터와 FBG를 이용한 광세기 기반 자기기준 광섬유 센서 (An Intensity Based Self-referencing Fiber Optic Sensor Using Tunable Fabry-Perot Filter and FBG)

  • 최상진;반재경
    • 전자공학회논문지
    • /
    • 제50권3호
    • /
    • pp.146-152
    • /
    • 2013
  • 본 논문에서는 자기기준 특성을 가지는 광세기 기반 광섬유 센서 구조를 제안하고 실험적으로 구현하여 성능을 제시한다. 제안하는 광섬유 센서는 광대역 광원(BLS), fiber Bragg grating (FBG), 가변 페브리-페로(Fabry-Perot) 필터, LabVIEW 프로그램으로 구성된다. 제안한 자기기준 광섬유 센서의 이론적인 해석을 통하여 측정 변수(X)와 보정 변수(${\beta}$)를 정의하고, 이를 바탕으로 전달함수(H)를 구한다. 또한 실험을 통하여 이론적인 해석의 타당성을 제시한다. 제안한 광섬유 센서 구조는 광대역 광원의 출력 광세기가 0 dB, 3 dB, 6 dB 감소해도 측정결과에 영향을 미치지 않는 자기기준 특성을 가진다. 또한 다른 특성의 FBG를 사용하여도 측정 가능하므로, 제안한 광섬유 센서 구조는 임의의 규격을 가진 FBG를 사용할 수 있다. 광원의 광세기가 감소하였을 때와 세 가지 다른 특성의 FBG 쌍을 이용하여 측정한 결과 이론적인 값과 잘 일치함을 보였다. 따라서 제안한 광섬유 센서는 자기기준 특성과 구성하는 FBG의 규격이 비교적 엄격하지 않아도 되는 장점을 가진다.

비접촉 암호 분석용 루프 프로브 설계 및 전자파 신호 측정 (Loop Probe Design and Measurement of Electromagnetic Wave Signal for Contactless Cryptographic Analysis)

  • 최종균;김채영;박제훈;문상재
    • 한국전자파학회논문지
    • /
    • 제18권10호
    • /
    • pp.1117-1125
    • /
    • 2007
  • 본 논문은 스마트카드에서 방사되는 전자파를 이용한 암호 분석용 소형 루프 프로브 설계와 프로브에 유기된 전자파 신호의 분석에 관한 연구이다. 암호 분석용 프로브는 일반적인 전자장 측정용 프로브와는 다르다. 그 이유는 제시된 프로브의 목적은 암호 장비의 비밀 키 해독에 필요한 정보를 얻기 위함이기 때문이다. 스마트카드에서 발생된 파형을 분석하여서 전자파 공격을 시도하기 때문에 프로브에 유기된 전압의 파형과 IC 칩에서 발생된 파형은 가능한 한 서로 동일해야 한다. 그 목적을 위해서 전자파를 이용한 암호 분석, 신호원의 근사 모델링, 암호 분석용 프로브의 특징, 전자파 신호 측정 그리고 프로브의 교정에 대한 검토가 필요하다. 스마트카드 칩의 소비 전력 신호와 제안된 프로브를 이용한 전자파 신호를 측정하고 두 신호를 EMA의 관점에서 비교하였다. ARIA 알고리즘을 적용하여 제안된 비접촉 암호 분석용 프로브의 적합성 여부를 실험적으로 확인하였다.

OPTICAL MULTI-CHANNEL INTENSITY INTERFEROMETRY - OR: HOW TO RESOLVE O-STARS IN THE MAGELLANIC CLOUDS

  • Trippe, Sascha;Kim, Jae-Young;Lee, Bangwon;Choi, Changsu;Oh, Junghwan;Lee, Taeseok;Yoon, Sung-Chul;Im, Myungshin;Park, Yong-Sun
    • 천문학회지
    • /
    • 제47권6호
    • /
    • pp.235-253
    • /
    • 2014
  • Intensity interferometry, based on the Hanbury Brown-Twiss effect, is a simple and inexpensive method for optical interferometry at microarcsecond angular resolutions; its use in astronomy was abandoned in the 1970s because of low sensitivity. Motivated by recent technical developments, we argue that the sensitivity of large modern intensity interferometers can be improved by factors up to approximately 25 000, corresponding to 11 photometric magnitudes, compared to the pioneering Narrabri Stellar Interferometer. This is made possible by (i) using avalanche photodiodes (APD) as light detectors, (ii) distributing the light received from the source over multiple independent spectral channels, and (iii) use of arrays composed of multiple large light collectors. Our approach permits the construction of large (with baselines ranging from few kilometers to intercontinental distances) optical interferometers at the cost of (very) long-baseline radio interferometers. Realistic intensity interferometer designs are able to achieve limiting R-band magnitudes as good as $m_R{\approx}14$, sufficient for spatially resolved observations of main-sequence O-type stars in the Magellanic Clouds. Multi-channel intensity interferometers can address a wide variety of science cases: (i) linear radii, effective temperatures, and luminosities of stars, via direct measurements of stellar angular sizes; (ii) mass-radius relationships of compact stellar remnants, via direct measurements of the angular sizes of white dwarfs; (iii) stellar rotation, via observations of rotation flattening and surface gravity darkening; (iv) stellar convection and the interaction of stellar photospheres and magnetic fields, via observations of dark and bright starspots; (v) the structure and evolution of multiple stars, via mapping of the companion stars and of accretion flows in interacting binaries; (vi) direct measurements of interstellar distances, derived from angular diameters of stars or via the interferometric Baade-Wesselink method; (vii) the physics of gas accretion onto supermassive black holes, via resolved observations of the central engines of luminous active galactic nuclei; and (viii) calibration of amplitude interferometers by providing a sample of calibrator stars.

선형가속기의 선량율에 따른 쐐기필터의 선량분포 (Dose Distribution of Wedge filter by Dose Rate in LINAC)

  • 권태형;김승욱;윤용학;원도연;정경환;정재은;조준호
    • 한국방사선학회논문지
    • /
    • 제9권5호
    • /
    • pp.323-329
    • /
    • 2015
  • 이 연구는 금속쐐기필터를 대신하여 동적쐐기필터를 사용할 수 있을지에 대한 적정성 평가에 관한 것이다. 선형가속기에서 발생되는 엑스선 에너지는 6 MV, 10 MV로 상용화되어있다. 금속쐐기필터의 $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$에 각각 100, 200, 300, 400, 500, 600 선량율(MU/min)로 48번 조사하였고, 동적쐐기필터와의 비교를 위해 같은 조건으로 총 96번 조사하였다. 측정조건은 선원필름간 거리 100cm, 조사면 $10{\times}10cm$ 로 측정하였다. 현상된 필름을 스캔하여 선량분석프로그램으로 교정 후 분석하였고, 표준편차를 구해 선량율을 비교하였다. 동적쐐기필터는 선량, 산란선 및 치료시간을 감소시키며, 환자에 조사되는 선량이 적어 매우 유용하다. 동일한 조건에서 선량율에 따른 오차는 연관성이 없으므로 환자의 상황에 따라 고선량율의 치료를 사용하는 것도 가능할 것으로 생각된다.

생태계 탄소순환 이해를 위한 국내 토양호흡 연구의 고찰 (Discussion of Soil Respiration for Understanding Ecosystem Carbon Cycle in Korea)

  • 이재호;이준석;전영문;채남이;이재석
    • 생태와환경
    • /
    • 제46권2호
    • /
    • pp.310-318
    • /
    • 2013
  • 육상생태계의 토양에는 대기의 약 2배에 해당하는 많은 양의 탄소를 가지고 있으며, 기후변화에 의한 기온 상승으로 대기로의 방출에 매우 취약한 상황에 놓여 있다. 한반도의 육상 생태계 토양탄소 수지의 변화예측을 위해 필연적으로 요구되는 다양한 생태계의 토양호흡 자료 수집을 위해 이용되는 방법론, 기기, 기기들 간의 오차, 시공간적인 불균일성, 결측 자료에 대한 보충 (gap filling), 발생원 별 구분 등에 대한 현 상황을 정리하고 그를 바탕으로 국내 토양호흡 연구의 문제점과 과제에 대해 고찰하였다. 결론적으로 국내의 토양호흡 연구는 기기 간 또는 방법들 간의 오차 보정이나 노력들이 매우 빈약하게 행해져 왔기 때문에 과거 및 현재 축적되는 자료의 품질은 거의 보정되지 않은 상태로 볼 수 있다. 이러한 문제점들이 해소되지 않고 지금까지와 같은 방식으로 토양호흡 자료가 축적된다면 그 활용성은 매우 낮을 수 밖에 없다. 또한 장기적인 자료 축적, 토양호흡 조절 메커니즘에 관한 조절 실험, 다양한 생태계, 토성, 토심 등에 대한 자료 역시 장래의 토양권 탄소 동태 변화를 모델 수단으로 예측하는 데에는 매우 중요한 요소이므로 토양호흡 자료 수집과 함께 수집되어야 할 것이다. 더불어 장기적인 측면에서 이러한 문제들이 연구자 간에 깊숙이 인식되어 보다 양질의 자료가 생산되도록 노력할 필요가 있다.

저온-진공 흑체시스템의 설계 및 성능 평가 (Design and Performance Evaluation of Low-Temperature Vacuum Blackbody System)

  • 김기석;장기수;이상용;김건희;김동익
    • 비파괴검사학회지
    • /
    • 제33권4호
    • /
    • pp.336-341
    • /
    • 2013
  • 본 논문에서는 저온-진공 흑체시스템의 설계 및 구성과 함께 흑체시스템의 수학 모델을 이용한 열해석 평가 방법과 그 결과를 제시하였으며 적외선 카메라를 이용한 흑체시스템의 평가 방안 및 결과를 명시하였다. 개발된 흑체시스템은 기존의 시스템에 비해 상대적으로 규모가 소형이며 273 K이하의 저온에서 수증기가 응결될 수 있는 현상을 방지하기 위하여 흑체시스템 내부를 진공 ($2.67{\times}10^{-2}$ Pa) 상태로 유지되도록 제작되었다. 또한 흑체시스템 내부의 열손실로 인한 성능 저하를 막기 위하여 radiator가 설치되는 부위에는 heat sink, heat shield 및 cold shield를 설계하였다. 흑체시스템의 수학 모델에 대한 열 해석을 위해서 변형된 스테판-볼츠만의 정리를 이용하여 radiator의 성능을 검증하였고 실제 흑체시스템에서 방사되는 적외선 신호에 대해서는 적외선 카메라를 이용하여 신호전달함수 및 온도분해능을 측정, 분석하였다. 제안된 설계와 해석 및 실험 결과에 근거하여, 개발된 저온-진공 흑체시스템은 적용온도범위인 268~333 K 구간에서 적외선 측정장치의 캘리브레이션을 위한 기준장치로서 성능이 안정적이고 적용이 적합한 것으로 확인되었다.

하나로의 즉발감마선 방사화분석 장치를 이용한 붕소의 정량에 대한 연구 (Study on Determination of Boron using the PGAA Facility at HANARO Research Reactor)

  • 정용삼;조현제;문종화;김선하;김영진
    • 분석과학
    • /
    • 제16권5호
    • /
    • pp.391-398
    • /
    • 2003
  • 하나로의 즉발감마선 방사화분석 장치를 이용하여 생물시료중의 붕소의 정량을 위한 기초연구를 수행하였다. 측정조건에 대한 특성조사를 위해 시료에 대한 중성자 조사 위치에서 중성자속 및 균질도를 측정하였다. 시료위치에서 열중성자 빔의 크기가 $2{\times}2cm^2$ 되도록 집속하였으며, 측정된 선속은 $1.0{\sim}6.5{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$ 범위를 나타냈으며, 중심부로부터 반경 4.5 mm 이내 및 9 mm 이내에서 각각 $5.77{\pm}0.71{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$, $4.68{\pm}1.64{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$이었다. 따라서 양질의 균일한 조사를 위해서 시료의 크기를 10 mm 이내로 조정하였다. 검출 시스템은 컴프턴 산란에 의한 백그라운드 요인을 억제하고 분석감도를 높이기 위해 설계되었으며, 감마선 계측 시스템의 에너지 교정과 컴프턴 억제율을 조사하기 위해 NaCl 표준체를 이용하여 단일 및 컴프턴 모드로 백그라운드를 측정하였다. 또한 정확한 붕소의 측정을 위해 시료의 매질효과로서 발생하는 분광학적 Na의 472 keV 피이크에 대한 간섭효과를 결정하였으며, 세 가지 인증표준물질 (NIST SRM 1570a, 1547, 1573a)을 이용한 붕소농도 측정시험을 두 가지 모드로 실시한 후 결과를 비교하였다.

플라즈마 진단을 위한 이온에너지 분석장치의 제작 및 특성 조사 (Fabrication and Its Characteristics of Ion Energy Spectrometer for Diagnostics of Plasma)

  • 김계령;김완;이용현;강희동
    • 센서학회지
    • /
    • 제7권3호
    • /
    • pp.163-170
    • /
    • 1998
  • 플라즈마 이온온도를 측정하기 위해 정전평판형 이온에너지 분석기를 설계 제작하고 에너지 교정 및 에너지 분해능 등의 특성을 조사하였다. 일정한 검출기 위치에서 이온의 에너지에 따른 편향평판전압은 선형성을 보였으며, $53{\sim}103mm$ 사이의 검출기 위치에서 이온에너지에 대한 최대편향평판전압의 기울기는 $1.61{\sim}0.92$로 검출기위치의 증가에 따라 선형적으로 감소하였다. 본 실험 영역에서 에너지 분해능은 약 $4.16{\sim}11.60%$였으며, 검출기 위치 및 이온에너지의 증가에 따라 향상되었다. 상대적 검출효율은 검출기 위치의 증가에 따라 감소하였다. 제작된 분석기를 다목적 플라즈마 발생장치에 설치하여 DC 플라즈마의 이온에너지 스펙트럼을 측정하였다. 방전전압이 320V, 전류가 0.17A인 DC 플라즈마의 이온온도는 $203{\sim}205eV$로 나타났으며 검출기의 위치에 따른 이온온도의 변화는 없었다. 검출기의 위치에 따른 에너지 분해능은 $18{\sim}21%$로 검출기 위치가 증가할수록 향상되었다.

  • PDF