• Title/Summary/Keyword: Sound-absorption Measure

Search Result 32, Processing Time 0.016 seconds

Studies on the Improvements for GAYAKUM Sounding Boards (가야금(伽倻琴) 향판재(響板材)의 개선(改善)에 관(關)한 연구(硏究))

  • Hong, Byung-Wha
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.65-78
    • /
    • 1990
  • For the purpose of Improving the sounding boards for the conventional GAYAKUM, I was making approximately 202 specimens of radial board, 371 specimens of tangential board by cutting along the grain and the part of stem and 31 specimens of the disjointed traditional GAYAKUM made in Paulownia coreana. And it was conducted to measure specific gravity, dynamic Young's modulus, internal friction, resonant frequency, velosity of sound and width of annual ring by the method of the frexural vibration in a free-free bar in the audio frequency range. And it confirmed the juvenile wood by measuring wood fiber length of specimens. It was also conducted to investigate dynamic properties and moisture absorption by various heat-treatment and to test dynamic Young's modulus and internal friction for the disjointed conventional GAYAKUM. The results obtained were summarized as follow: 1. The Juvenile wood is located within about 7 annual rings from the pith in Paulownia coreana. 2. As increased with the specific gravity, the dynamic Young's modulus had more and more increased, but the internal friction had slightly decreased. 3. I think that radial board would be good for sounding board wood. because radial board is higher than tangential board in dynamic Young's mudulus and internal friction is lower than tangential board. 4. The value of mean dynamic Young's modulus on the conventional GAYAKUM, radial board and tangential board of 604 samples is $0.4283\pm0.037(\times10^{11}dyne/cm^2)$, $0.4316\pm(\times10^{11}dyne/cm^2)$ and $0.4234\pm0.112(\times10^{11}dyne/cm^2)$ respectively. The value of the radial board showed little higher than that of conventional GAYAKUM, but It had a similar tendency between conventional GAYAKUM and tangential board. 5. The annual ring width by four aspect is more narrow in north and west than that of others. 6. The values of specific gravity and dynamic Young's modulus in the mature wood showed higher than those of juvenile wood. 7. As the grain angle in the butt wood more increased to bark from pith, the dynamic Young's modulus were low. Then it was not good for sounding board. 8. It appeared that the heat-treatment for sounding board wood had a more effect to do the treatment of hotiron on surface after heat-treatment during 24 hours in $60^{\circ}C$ temperature. 9. As increased with the temperature, the rate of moisture absorption of heat-treatment wood had decreased. In conclusion, I thought that the sounding board wood for GAYAKUM would had the most effect to do the treatment of hotiron on surface after heat-treatment during 24 hours in $60^{\circ}C$ temperature using the radial board of mature wood.

  • PDF

Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid (이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰)

  • Jung, Eui-Sung;Seong, Ki-Woong;Lim, Hyung-Gyu;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.