• Title/Summary/Keyword: Sound parameters

Search Result 607, Processing Time 0.027 seconds

Design of a Multimode Piezoelectric Spherical Vector Sensor for a Cardioid Beam Pattern (심장형 빔 패턴을 위한 다중모드 압전 구형 벡터센서 설계)

  • Lim, Youngsub;Lee, Jaeyoung;Joh, Cheeyoung;Seo, Heeseon;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.32-42
    • /
    • 2013
  • Typical underwater piezoelectric spherical sensors are omni-directional, thus can measure the scalar quantity sound-pressure-magnitude only with the limitation not being able to measure the direction of the incoming wave. This paper proposes a method to simultaneously measure both the magnitude and direction of the sound wave with the spherical sensor. The method divides the piezoceramic sphere of the sensor into eight elements, and distinguishes the magnitude and direction of the sound pressure by combining the output voltage of the elements in a particular manner. Further, through the analysis of the sensitivity variation in relation to the structural parameters like radius and thickness of the piezoceramic sphere, we have suggested the way to improve the sensitivity of the vector sensor.

Performance enhancement of underwater acoustic source localization by nonlinear optimization of multiple parameters (다수 정보들의 비선형 최적화에 의한 수중 음원 위치 추정 성능 향상)

  • Yang, In-Sik;Kwon, Taek-Ik;Kang, Tae-Woong;Kim, Ki-Man
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.6
    • /
    • pp.419-424
    • /
    • 2017
  • TDoA (Time Difference-of Arrival) or DoA (Direction-of-Arrival) can be used for source localization. However, the localizing performance is dependent on relative position between source and receivers, receivers' geometric structure, sound speed, and so on. In this paper we propose a source localization method with enhanced performance that combines multiple information. The proposed method uses the time TDoA, DoA and sound speed as variables. LM (Levenberg-Marquardt) method which is one of nonlinear optimizations is applied. The performances of the proposed method was evaluated by simulation. As result of simulation, the proposed method has the lower average localizing error performance than the previous method.

Creep Damage Evaluation of Cr-Mo Steel High-Temperature Pipeline Material for Fossil Power Plant Using Ultrasonic Test Method (초음파법을 이용한 Cr-Mo강 고온배관재료의 크리프손상 평가)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.18-26
    • /
    • 2000
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operating conditions such as high temperature and high pressure for an extended period time. Conventional measurement techniques(replica method, electric resistance method, and hardness test method) for measuring creep damage have such disadvantages as complex preparation and measurement procedures, too many control parameters. And also these techniques have low practicality and applied only to component surfaces with good accessibility. In this paper, artificial creep degradation test and ultrasonic measurement for their creep degraded specimens(Cr-Mo alloy steels) were carried out for the purpose of evaluation for creep damage. Absolute measuring method of quantitative ultrasonic measurement for material degradation was established, and long term creep degradation tests using life prediction formula were carried out. As a result of ultrasonic tests for crept specimens. we conformed that both the sound velocity decreased and attenuation coefficient linearly increased in proportion to the Increase of creep life fraction($\Phi$c).

  • PDF

Study of Optimum Operating Conditions of Thermal Acoustic Generator (열음향파 발생장치의 최적 작동 조건에 대한 실험적 연구)

  • Shin, Sang Woong;Oh, Seung Jin;Lee, Yoon Joon;Kim, Nam Jin;Chun, Wongee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.131-137
    • /
    • 2013
  • This study deals with the effects of major geometric parameters on the sound wave output of a thermal acoustic system. The output power of the acoustic wave was dependent on the stack position, stack length, resonator tube length, and input power. In experiments, the maximum SPL was generated when the stack was placed between one-fourth to half, resonator and stack length were longer, and input power was increased. The frequency was recorded to be 437 and 885 Hz when the resonator tube length was 200 and 100 mm, respectively. Therefore, when the resonator tube length was shorter, a higher frequency was recorded.

Design of the DSP for the FM Sound Synthesis (FM 합성방식을 이용한 악기음 합성용 DSP 설계)

  • Kwon, Min-Do;Jang, Ho-Keun;Kim, Jae-Yong;Park, Ju-Sung;Kim, Hyung-Soon;Yun, Pyung-Woo;Baek, Kwang-Ryul;Im, Chang-Hun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.63-73
    • /
    • 1995
  • The conventional acoustic sounds can be synthesized by Frequency Modulation which includes the variation of frequency, amplitude, and modulation index. In this paper the number of variable synthesis parameters are limited to easily implement the existing two carrier FM algorithm by hardware. The DSP(Digital Signal Processor), which is able to carry out the modified algorithm and synthesize 16 sounds at a time, is designed with $0.8{\mu}m$ standard sells. The DSP which can synthesize 2 sounds at a time is implemented by ASIC emulator to examine the sound quality of the designed DSP. Through the objective and subjective estimation, it is confirmed that the sounds of many instruments from the implemented DSP are very closed to their real sound. Finally the designed DSP is layouted and simulated by VLSI desgn tool. According to the simulation, the designed DSP has the sufficiently fast speed for synthesizing 16 sounds at a time.

  • PDF

Combination Effects of Zusanli(ST36) Electroacupuncture and Manual Acupuncture of other Acupoints on Gastric Vagal Nerve Activity and Pyloric Valve Function in Patients with Functional Dyspepsia. (기능성 소화불량증 환자의 위 미주신경 활성 및 유문부 기능에 대한 족삼리(足三里) 전침과 일반 체침 자극의 복합 효능)

  • Kim, Yoo-Seung;Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.3
    • /
    • pp.621-628
    • /
    • 2008
  • Objectives : The aim of this study was to investigate changes of gastric vagal nerve activity and pyloric valve function after execution of combination treatments of both electroacupuncture at Zusanli(ST36) and manual acupuncture at other acupoints in patient with functional dyspepsia. Methods : Bowel sounds of 49 patients (18 male, 31 female) were recorded and their % of bowel sound (%BS) and ratio of dominant frequency (DF) were analyzed. Postprandial %BS was used to indicate the gastric vagal activity after eating. Ratio of postprandial/fasting dominant frequency was used to present the degree of pyloric valve function. According to values of %BS and DF ratio, each patient was classified into normal or abnormal (<6 %BS, hypoactivity: <1 DF ratio, dysfunction) group. For 2 weeks, patients received a treatment consisting of both electroacupuncture stimulation at Zusanli (ST36) and acupuncture at other meridian points. Variation of parameters shifting normal to abnormal or abnormal to normal was observed, and total cure rate was calculated. Results : Total cure rate of %BS was 16%, and that of DF was 37%. Patients who improved to normal value from abnormal or aggravated to abnormal level showed both significant difference in both vagal nerve hypoactivity and pyloric valve dysfunction, respectively. Conclusions : Analysis of bowel sound might be useful to evaluate both gastric vagal nerve activity and pyloric valve function. Combination effects of Zusanli (ST36) electroacupuncture and manual acupuncture of other acupoints showed a bidirectional effect in which their activity and function were in general improved. sometimes from aggravated to abnormal level.

  • PDF

The Comparison of Sonographic Features of Ankle Ligament and Tendon in Affected Side With Non-Affected Side Ambulatory of Hemiplegic Patients (보행 가능한 편마비 환자에서 편측 및 건측 하지 발목 관절의 인대와 힘줄의 초음파 비교)

  • Park, Ji-Woong;An, Jae-Ki;Park, Yong-Bum;Bae, Won-Sik
    • Physical Therapy Korea
    • /
    • v.17 no.2
    • /
    • pp.60-66
    • /
    • 2010
  • In chronic ambulatory hemiplegic patients, structural changes might be developed at both ankles possibly due to unequal and repetitive weight bearing on tendons and ligaments. We examined ankles by sonography to find out structural changes of tendons and ligaments of both ankles in ambulatory hemiplegic patients. Nineteen ambulatory hemiplegic patients over 1 year were included as study subjects. All subjects had no previous trauma or disease history in their ankle joints and they were able to walk independently or with supervision but had spastic ankles with equinovarus tendency. We examined both ankle joints by sonography to see joint effusion and measure width, thickness, and area of tendons of the tibialis anterior, tibialis posterior, and Achilles, and also ligaments of the anterior talofibular and calcaneofibular. We compared sonographic features of the hemi-side ankle with the sound-side ankle. There were no significant differences between hemi-side and sound-side ankles in almost all measured parameters of tendons and ligaments. However, the width of the hemi-side tibialis posterior tendon ($7.24{\pm}1.52$ mm) was narrower than the sound-side tendon ($8.61{\pm}1.37$ mm). With the amount of active joint motion and weight bearing possibly preventing ligament and tendon atrophy even though marked weakness, spasticity occurred during the chronic hemiplegic phase.

A Merging Algorithm with the Discrete Wavelet Transform to Extract Valid Speech-Sounds (이산 웨이브렛 변환을 이용한 유효 음성 추출을 위한 머징 알고리즘)

  • Kim, Jin-Ok;Hwang, Dae-Jun;Paek, Han-Wook;Chung, Chin-Hyun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.3
    • /
    • pp.289-294
    • /
    • 2002
  • A valid speech-sound block can be classified to provide important information for speech recognition. The classification of the speech-sound block comes from the MRA(multi-resolution analysis) property of the DWT(discrete wavelet transform), which is used to reduce the computational time for the pre-processing of speech recognition. The merging algorithm is proposed to extract valid speech-sounds in terms of position and frequency range. It needs some numerical methods for an adaptive DWT implementation and performs unvoiced/voiced classification and denoising. Since the merging algorithm can decide the processing parameters relating to voices only and is independent of system noises, it is useful for extracting valid speech-sounds. The merging algorithm has an adaptive feature for arbitrary system noises and an excellent denoising SNR(signal-to-nolle ratio).

Near-field limit in positioning the microphone for pressure measurements in using the near-field acoustical holography (근접 음향 홀로그래피에서 음압 측정용 마이크로폰의 근접 거리 한계)

  • Kang, Sung-Chon;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.731-736
    • /
    • 2000
  • The recently developed BEM-based NAH(nearfield acoustical holography) is a useful technique for identifying the sound source of vibrating objects. The acoustic parameters of a sound source can be reconstructed by using the vibro-acoustic transfer matrix, which is determined by means of BEM, and the sound pressure measured in the nearfield. Theoretically, one can come up with a very nice reconstructed result as the field plane gets near to the source surface. However, when a microphone is placed in the very close nearfield of the source surface, the scattering, reflection, or resonance in the gap between the source and the microphone can distort the acoustic field, and therefore, the measured field pressure would differ from the actual one in the absence of the microphone. In order to analyze this problem, the interference effect of the microphone is numerically calculated by using the nonsingular BEM that yields very small error in the nearfield. From this analysis, it is found that the prediction error of the field pressure decreases firstly and then increases as the microphone approaches the vibrating surface from the farfield to the close nearfield. It is noted that the microphone should be separated from the source surface by at least a diameter of the microphone for an error ratio less than 2% in the low frequency range less than about 2.7kHz. This means that if one wants to put a microphone in the very close nearfield. a microphone with small diameter should be used.

  • PDF

Broadband Transmission Noise Reduction Performance of Smart Panels Featuring Piezoelectric Shunt Damping and Passive Characteristics (압전감쇠와 수동적 특성을 갖는 압전지능패널의 광대역 전달 소음저감성능)

  • 이중근;김재환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.150-159
    • /
    • 2002
  • The possibility of a broadband noise reduction of piezoelectric smart panels is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing material is bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to tune the piezoelectric shunt circuit, the measured electrical impedance model is adopted. Resonant shunt circuit composed of register and inductor in stories is considered and the circuit parameters are determined based on maximizing the dissipated energy through the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a square crosses sectional tunnel and a loud speaker is mounted at one side of the tunnel as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across the panels is measured. Noise reduction performance of a double smart panel possessing absorbing material and air gap shows a good result at mid frequency region except the first resonance frequency. By enabling the piezoelectric shunt damping, noise reduction is achieved at the resonance frequency as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.