• 제목/요약/키워드: Sound isolation materials

검색결과 23건 처리시간 0.026초

Development of a Practical Two-Microphone Impedance Tube Method for Sound Transmission Loss Measurement of Sound Isolation Materials

  • Ro, Sing-Nam;Hwang, Yoon;Lee, Dong-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권3호
    • /
    • pp.105-113
    • /
    • 2003
  • This study developed a practical two-microphone impedance tube method to measure the sound transmission loss of sound isolation materials without the use of an expensive reverberation room or an acoustic intensity probe. In order to evaluate the validation and applicability of the two-microphone impedance tube method, sound transmission losses for several sound isolation materials with different surface density and bending stiffness were measured, and the measured values were compared with the results from the reverberation room method and the theory. From the experimental results, it was found that the accuracy of sound transmission loss obtained by the impedance tube method depends upon the diameter size of the impedance tube (i.e., tested sample size). For sound isolation materials having relatively large bending stiffness such as acryl, wood, and aluminum plates, it was found that the impedance tube method proposed by this study was not valid to measure the sound transmission loss. On the other hand, for sound isolation materials having relatively small bending stiffness such as rubber, polyvinyl, and asphalt sheets, the comparisons of transmission loss between the results from the impedance tube method and the theory showed a good agreement within the range of the frequencies satisfying the normal incidence mass law. Therefore, the two-microphone impedance tube method proposed by this study can be an effective measurement method to evaluate the sound transmission loss for soft sound isolation sheets having relatively small bending stiffness.

복합재료를 이용한 시트형 차음재 개발 (Development of Sound Isolation Sheets with Compound Materials)

  • 이동훈;이태근;정성균;이희원;강문;김영배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.415-420
    • /
    • 2000
  • This paper describes a part of the results obtained in the process of the development of thin sound isolation sheets filled mineral compound powder with PVC. The raw materials used are pyrophillite, pottery stone and graphite. The physical properties such as the crystal structures, compositions, and specific gravities, etc. of raw materials are analyzed and discussed from a point of view of sound isolation material. From the analysis of experimental results, the particle size and the additive amount of mineral compound powder for manufacturing sample isolation sheets are decided. The resistant capability against fire of sound isolation sheets including mechanical, thermal and physical properties is tested. The transmission loss measuremenst of sound isolation sheets are performed using two-microphone method in an impedance tube. It is shown that the sound isolation capability of thin sheets has an excellent performance in excess of the object of development.

  • PDF

차음재의 음향투과손실 측정에 Two-Microphone Impedance Tube Method의 적용과 한계 (The Limit and Application of Two-microphone Impedance Tube Method to the Sound Transmission Loss Measurement of Sound Isolation Materials)

  • 이승;안민홍;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.883-888
    • /
    • 2002
  • This study describes the limit and application of the two-microphone impedance tube method to the sound transmission loss measurement of several sound isolation materials with different physical properties. For the sound isolation materials having small flexural rigidity, it is shown that the two-microphone impedance tube method is validated to practically measure the sound transmission loss. For the sound isolation materials having large flexural rigidity, on the other hand, it is found that the two-microphone impedance tube method is no longer valid to measure the sound transmission loss because the regions of resonance and mass law are moved into the higher frequencies. In addition, in order to accurately measure the sound transmission loss of sound isolation materials, their size should be decided based on the consideration of the effect of acoustic excitation on their vibration response.

  • PDF

바닥충격음 측정 및 차음 평가의 방향 (Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance)

  • 정정호;정영;서상호;송희수;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

폐타이어 칩의 바닥충격음 차단성능에 관한 실험적 연구 (The Experimental Study on the Impact Sound Insulation Floors due to Waste Tire Chip)

  • 양관섭;이세현;김홍열;김승민
    • 소음진동
    • /
    • 제9권3호
    • /
    • pp.477-484
    • /
    • 1999
  • This study aims to present proper thickness of resilient mount and pattern of chips for the improvement of impact sound isolation. To achieve this aim, field tests were performed to evaluate the performance of impact sound isolation of pilot samples using waste tire chips against light and heavy-weight impacter, which samples were installed over concrete slabs of an apartment housing. In this study, the experiments were performed by the impact sound level of floors in KS F 2810 "Method for field measurement of floor impact level". As results, a flooring structure using waste tire chips as a resilient mount, with no relation to chip's types, has enhanced performance by 1~2 degree in light impact sound isolation, while it has improvement in heavy impact sound isolation. And fiber-type chips have better performance than granule-type ones when they overlaid concrete slab with 15~20 mm of thickness. For the improvement of impact sound isolation, it is recommended that insulating materials should be applied at joints between floating floors and walls, or floating floors and a doorframes, and also waterproof papers should be used for the effective thickness of resilient mount.ent mount.

  • PDF

차음시트의 음향투과손실 측정에 관한 연구 (A Study on the Sound Transmission Loss Measurement of Sound Isolation Sheets)

  • 이동훈;강문;이주원;정갑철;권영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.409-414
    • /
    • 2000
  • A new impedance tube method is presented for the measurement of transmission loss of sound isolation sheets. The two-microphone method based on the sound decomposition theory proposed by Seybert and Ross is reviewed in this impedance tube method, which has been used for the determination of absorption coefficient of absorptive materials as well as transmission loss of automotive mufflers. Sound transmission losses for rubber, polyvinyl and asphalt sheets are measured in an impedance tube and reverberation room facility, respectively. By comparing two measurement methods, the reliability of impedance tube method used in this study is validated. From the experimental results, it is shown that the accuracy of sound isolation capability obtained by the impedance tube method depends upon the microphone spacing and the distance of the first microphone from the test sample surface.

  • PDF

중공 섬유를 이용한 자동차 흡음재 성능 향상 연구 (The Study on Improvement of Acoustic Performance for Automobile Sound-absorbing Materials Using Hollow Fiber)

  • 이정욱;이수남;심재현;정판기;이원구;방병주
    • 한국소음진동공학회논문집
    • /
    • 제21권9호
    • /
    • pp.850-857
    • /
    • 2011
  • Generally, sound-absorbing materials in vehicles are used for giving the comfort to passengers by reducing noise while driving. Materials of which targets are light weight, high performance, eco friendliness and recycling have been developed recently. In this study, sound-absorbing materials using PET(polyethylene terephthalate) hollow fibers to achieve the light weight and the high sound absorption performance are developed, and then evaluated to meet a requirement for the automotive components. The test results show that the acoustic performances of developed products having new fiber structure are better than those of the conventional product.

감쇠재 사용에 따른 중량충격음의 소음 및 진동특성 (Noise and Vibration Characteristics of Heavy-weight floor impact by Using Damping Materials)

  • 전진용;정영;송희수;김민배;이영제
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.97-102
    • /
    • 2004
  • The Characteristics of noise and vibration by heavy-weight floor impact sound was studied. Resonance frequency increased a little in structures that use damping material in living room and bedroom, and acceleration waves length that respond became short, and displayed aspect that oscillation level decreases. Result that measure sound pressure level, structure that compare and applies damping materials with structure that apply the resilient materials from 63Hz lower part that impact energy is concentrated in energy spectrum of heavy-weight floor impact sound displayed result that sound pressure, level decreases remarkably. Therefore, according to use of damping materials, confirmed reduction effect of heavy-weight floor impact sound.

  • PDF

다중 페널의 차음성능에 대한 실험적 연구 (Empirical Research for the Sound Insertion Loss of Panels)

  • 고강호;국형석;김영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.198-203
    • /
    • 2001
  • This paper discusses an experimental method for measuring the insertion loss (IL) performance of a double panel that are used in vehicles. Instead of two adjacent reverberation chambers which are generally used to measure the transmission loss (TL) of the large sound isolation materials, air-borne sound insulation tester was utilized to determine the IL and articulation index (AI) of standardized deadening materials. In comparison to reverberation chamber method, air-borne sound insulation tester method is more space-saving, more time-saving and more simple to the automotive acoustics. From the empirical results, it is verified that the performance of deadening materials is closely connected with thickness of panels, type of filling material that is filled into a double panel, and area ratio of double panel.

  • PDF

다층 인슐레이션의 차음성능에 대한 실험적 연구 (Experimental Research for Air-borne Noise Reduction of a Multi-layered Insulation)

  • 고강호;김영호;국형석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1185-1191
    • /
    • 2001
  • This paper discusses an experimental method for measuring the insertion loss (IL) performance of multi-layered insulations that are used in vehicles. Instead of two adjacent reverberation chambers which are generally used to measure the transmission loss (TL) of the large sound isolation materials, air-borne sound insulation tester was utilized to determine the IL and articulation index (AI) of standardized insulation materials. In comparison to reverberation chamber method, air-borne sound insulation tester method is more space-saving, more time-saving and more simple to the automotive acoustics. From the empirical results, it is found that the performances of insulation materials are closely connected with density of polyurethane foam, thickness of heavy layer, thickness of polyurethane foam, and application ratio to panel area.

  • PDF