• Title/Summary/Keyword: Sound intensity method

Search Result 134, Processing Time 0.022 seconds

독립, 비독립 음원이 동시에 존재할 경우 선형 마이크로폰 어레이를 이용한 소음원 탐지 방법 (Indentification of Coherent/Incoherent Noise Sources Using A Microphone Line Array)

  • 김시문;김양한
    • 소음진동
    • /
    • 제6권6호
    • /
    • pp.835-842
    • /
    • 1996
  • To identify the locations and strengths of acoustic sources, one may use a microphone line array. Apparent advantage of the source identification method utilizing a line array is that it requires less measurement points than intensity method and holography. This method is based on the information of magnitude and phase difference between pressure signals at each microphone. Since those differences are dependent on the source model, we have to assume them such as plane, monopole, etc. In this paper the conventional source identification methods such as beamforming method and MUSIC method are briefly reviewed by modeling a source as plane and spherical wave, then a modified method is introduced. This can be applied to sound field which may by either coherent or incoherent. Typical simulations and experiment are performed to confirm this identification method.

  • PDF

Classification of Porcine Wasting Diseases Using Sound Analysis

  • Gutierrez, W.M.;Kim, S.;Kim, D.H.;Yeon, S.C.;Chang, H.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제23권8호
    • /
    • pp.1096-1104
    • /
    • 2010
  • This bio-acoustic study was aimed at classifying the different porcine wasting diseases through sound analysis with emphasis given to differences in the acoustic footprints of coughs in porcine circo virus type 2 (PCV2), porcine reproductive and respiratory syndrome (PRRS) virus and Mycoplasma hyopneumoniae (MH) - infected pigs from a normal cough. A total of 36 pigs (Yorkshire${\times}$Landrace${\times}$Duroc) with average weight ranging between 25-30 kg were studied, and blood samples of the suspected infected pigs were collected and subjected to serological analysis to determine PCV2, PRRS and MH. Sounds emitted by coughing pigs were recorded individually for 30 minutes depending on cough attacks by a digital camcorder placed within a meter distance from the animal. Recorded signals were digitalized in a PC using the Cool Edit Program, classified through labeling method, and analyzed by one-way analysis of variance and discriminant analysis. Input features after classification showed that normal cough had the highest pitch level compared to other infectious diseases (p<0.002) but not statistically different from PRRS and MH. PCV2 differed statistically (p<0.002) from the normal cough and PRRS but not from MH. MH had the highest intensity and all coughs differed statistically from each other (p<0.0001). PCV2 was statistically different from others (p<0.0001) in formants 1, 2, 3 and 4. There was no statistical difference in duration between different porcine diseases and the normal cough (p>0.6863). Mechanisms of cough sound creation in the airway could be used to explain these observed acoustic differences and these findings indicated that the existence of acoustically different cough patterns depend on causes or the animals' respiratory system conditions. Conclusively, differences in the status of lungs results in different cough sounds. Finally, this study could be useful in supporting an early detection method based on the on-line cough counter algorithm for the initial diagnosis of sick animals in breeding farms.

스테레오 입체음향을 위한 머리 움직임 추정 (A Tracking of Head Movement for Stereophonic 3-D Sound)

  • 김현태;이광의;박장식
    • 한국멀티미디어학회논문지
    • /
    • 제8권11호
    • /
    • pp.1421-1431
    • /
    • 2005
  • 입체음향을 구현하는 방법은 두 가지가 있으며, 5.1 채널과 같은 서라운드 시스템(surround system)을 이용하는 방법과 2 채널의 바이노럴 시스템(binaural system)을 이용하는 방법이 있다. 바이노럴 시스템은 사람이 두 귀를 이용하여 음상을 정위하는 원리를 이용하는 방법이다. 일반적으로 라우더 스피커 시스템에서 각 채널사이에 발생하는 크로스토크(crosstalk)는 본래의 입체음향을 재생하기 위해서는 제거되어야만 한다. 이 문제를 해결하기 위해서는 머리의 움직임을 추정할 필요가 있다. 본 논문에서는 청취자의 머리 움직임을 제대로 추정하는 새로운 알고리즘을 제안한다. 제안하는 알고리즘은 얼굴과 눈의 영역 검출을 기본으로 한다. 얼굴 검출은 이미지의 밝기 값을 이용하고 눈 검출은 수학적 형태학(mathematical morphology)을 이용한다. 청취자의 머리가 움직일 때 얼굴 영역과 눈 사이의 경계선의 길이가 변한다. 이 정보를 이용하여 머리 움직임을 추정한다. 컴퓨터 시뮬레이션을 통해 제안하는 알고리즘이 +10오차 범위 내에서 머리의 움직임을 효율적으로 추정하는 것을 확인하였다.

  • PDF

터보형송풍기의 소음 방사특성에 관한 실험적 연구 (A Study on the Noise Emission Characteristics of Turbo Axial Flow Fan by Experimental Method)

  • 김동규;백종진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.271-277
    • /
    • 2003
  • 최근 환경 소음이 사회적인 문제로 대두되고 있는 가운데, 생활수준의 향상으로 저소음화에 대한 요구가 증가되고 있는 실정이다. 이와 같이 소음에 관한 일반인들의 관심이 높아지면서 생환주변에서 주요 소음원으로 지적되고 있는 회전기계, 특히 가전제품을 비롯한 유동관련 기계류의 소음을 낮추기 위한 노력이 절실히 요구되고 있다. 본 소평팬에 대한 연구에서는 음압 및 음향인텐시티를 이용하여 소음원을 해석하였다. 이때, 광센서를 이용한 축류형 팬의 동기화가 수행되어졌고, 팬 형상에서 정확한 소음원의 위치를 규명하기 위한 기록시간의 결정이 제안되어졌다. 소음 발생하는 위치를 규명하였고, 지향성 연구를 통하여 축류형 팬의 방사형태를 결정하였으며, 음의 흐름도를 가시화 하였다.

  • PDF

음환경의 쾌적성에 관한 의미구조의 분석 II -소음의 심리적 평가요인과 속성- (An Analysis on the Structure of Meaning for Amenities of Sound Environment II -Psychological Evaluation Factors and Attributes of Noise-)

  • 한명호;김선우
    • 소음진동
    • /
    • 제8권4호
    • /
    • pp.706-714
    • /
    • 1998
  • The purpose of this study is to analyse the main factors and attributes of psychological evaluation to noise. For this purpose, a psycho-acustic experiment was conducted by using the method of rating scale. 52 subjects were participated in the experiment, 20 stimuli were presented to subjects in random order with 23 adjectives. As a result of factor analysis, it was found that the primary factors for evaluating the quality of noise subjectively are four factors of unpleasantness, intensity, irregularity, and sharpness. And, as a result of MDPREF(multi-dimensional analysis of preference data), it was found that the noise sources including the factors of unpleasantness, intensity, and irregularity are related to the sounds of hammering in construction field, car horn, road traffic, idling of car, and printing by computer printer, and the factor of sharpness are the sounds of car siren, claps of thunder, car horn, and snowstorm etc.

  • PDF

Perceptual Experiment on Number Production for Speaker Identification

  • Yang, Byung-Gon
    • 음성과학
    • /
    • 제8권1호
    • /
    • pp.7-19
    • /
    • 2001
  • The acoustic parameters of nine Korean numbers were analyzed by Praat, a speech analysis software, and synthesized by SenSynPPC, a Klatt formant synthesizer. The overall intensity, pitch and formant values of the numbers were modified dynamically by a step of 1 dB, 1 Hz and 2.5% respectively. The study explored the sensitivity of listeners to changes in the three acoustic parameters. Twelve subjects (male and female) listened to 390 pairs of synthesized numbers and judged whether the given pair sounded the same or different. Results showed that subjects perceived the same sound quality within the range of 6.6 dB of intensity variation, 10.5 Hz of pitch variation and 5.9% of the first three formant variations. The male and female groups showed almost the same perceptual ranges. Also, an asymmetrical structure of high and low boundary was observed. The ranges may be applicable to the development of a speaker identification system while the method of synthesis modification may apply to its evaluation data.

  • PDF

Pulsed Nd ; YGA 레이저의 치수마취효과에 관한 연구 (A STUDY OF ANALGESIC EFFECT ON PULP INDUCED BY PULSED Nd : YAG LASER)

  • 김도형;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제24권1호
    • /
    • pp.301-312
    • /
    • 1997
  • The purpose of this study was to evaluate the analgesic effect on pulp induced by pulsed Nd : YAG laser according to the power density, irradiated time and the method of application (Non-contact vs contact) in vivo. Experiments were carried out on 90 volunteers who have sound 4 canines. Each canine was grouped by the intensity and the time of irradiation of pulsed Nd : YAG laser was measured. Mean EPT response(units) was measured at 5 min, 30 min, and 60 min after irradiation with various intensity(1.5-3W, 15-30Hz), irradiated time (1.5min, 3min), and application method (Non-contact and contact). The results were as follows: 1. 5 minutes after irradiation, the mean EPT response(units) was increased by 32 % in the non-contact method and by 35% in the contact method of application. Which showed significant difference in mean EPT response(units) compared to not-lased canine in each groups(P<0.05). 2. The mean EPT response(units) with irradiating condition according to the various laser intensity, and the irradiation time stastically did not show significant difference in each groups as time elapsed. 3. There was no significant difference between the non-contact and contact method in the mean EPT response(units). 4. The mean EPT response(units) returned to the baseline value within 30 miuntes. In regard to the above results, the analgesic effect on pulp induced by pulsed Nd : YAG laser resulted a slight increase of pulpal pain threshold, but it was not as high as to replace the role of drug analgesia as whole. This technique can be used for inducing pulpal analgesia as adjunct to other pain control methods and is needed to develop better analgesic effects.

  • PDF

유한요소법에 의한 소음기의 감음특성해석 (Analysis of Sound Attenuation by Chambers in Duct Systems by the Finite Element Method)

  • 최석주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1991년도 춘계학술대회논문집; 한국해사기술연구소, 대전; 1 Jun. 1991
    • /
    • pp.23-27
    • /
    • 1991
  • 각종 홀 (음악홀, 극장, 사무실건물)의 공조 덕트계에는 미로형소음챔버가 설 치되는 경우가 많다. 이러한 소음장치를 건물내부에 설치하는 경우에는 건물 설계단계에서부터 소음챔버로 인한 감음양(투과손실 : Transmission Loss)의 예측계산이 중요하다. 그렇지만, 일반적인 소음장치는 그 형상이나 내표면의 흡음조건이 아주 복잡하기 때문에, 현단계에서는 간단한 이론만으로 투과손 실예측이 거의 불가능하다. 지금까지 이 문제에 대해서 유한요소법(Finite Element Method : FEM)을 이용해 검토한 예가 종종 소개되었으나, 대부분 소음챔버의 입구와 출구에서의 임의의 점에 대한 음압비를 투과손실로서 구 하고 있다. 그러나, 소음기자체의 실질적인 투과손실특성을 알기 위해서는 소음기의 입력 파워에 대한 출력파워의 비로서 구하지 않으면 안된다. 따라 서, 본 연구에서는 유한요소법에 의한 복소음향인텐시티(Complex sound intensity)의 수치계산법을 각종소음기 (팽창형, 미로형)의 투과손실해석에 적 용하기 위하여 이론적인 면에서 고찰했으며, 프로그램도 개발하여 모델해석 에 적용하였다. 또한, 위에서 언급된 수치해석법의 타당성의 검증을 위하여, 측정에 의한 투과손실예측방법으로서 크로스스펙트럼(Cross Spectrum)법에 의한 음향인텐시티계측법의 이용에 대해서 이론적으로 고찰했으며, 그 이론 을 기초로 한 축척 모형실험을 병행하였다.

  • PDF

우주비행체 음향-진동 연성시험장치 개발 (Development of Vibro-acoustic Testing System for Space Flight Vehic1e)

  • 김홍배;문상무;우성현;이동우;이상설
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.96-102
    • /
    • 2001
  • High intensity vibro-acoustic testing is the appropriate method for flight qualification testing of space flight vehicle which must ensure the acoustic environment of launch. Growing demand for satellites and launch vehicles in korea has resulted in a recent increase in the demand for high intensity vibro-acoustic test facility. The test facility is designed to provide an acoustic environment of 152 ㏈( re 20 ${\mu}$Pa) overall sound pressure level over the band width of 30 Hz to 10,000 Hz in the reverberant chamber. The reverberant chamber has a volume of 1,000 ㎥ with interior dimensions of 8.7m${\times}$l0m${\times}$12m, which can accommodate not only satellites but also launch vehicle payload fairing. Korea Aerospace Research Institute and Korean industries have been carrying out the development of the reverberant chamber and auxiliary devices, such as automatic control system, monitoring/safety device, and jet nozzle, etc. This paper presents the detailed description of High Intensity Acoustic Chamber of KARI, which will be the first and unique testing facility in Korea.

  • PDF

음도 고정 시 강도 변화에 따른 일반인과 성악인 발성의 성대접촉률 변화 특성의 비교 (The Changes in the Closed Qutient of Trained Singers and Untrained Controls Under Varying Intensity at a Constant Vocal Pitch)

  • 김한수;전용선;정성민;조근경;박은희
    • 대한후두음성언어의학회지
    • /
    • 제16권1호
    • /
    • pp.28-32
    • /
    • 2005
  • Background and Objectives : The most important two factors of the voice production are the respiratory function which is the power source of voice and the glottic closure that transform the air flow into sound signals. The purpose of this study was to investigate the differences between trained singers and untrained controls under varying intensity at a constant vocal pitch by simulataneous using the airway interruption method and electroglottography(EGG). Materials and Methods : Under two different intensity condition at a constant vocal pitch(/G/), 20(Male 10, Female 10) trained singers were studied. Mean flow rate(MFR), subglottic pressure(Psub) and intensity were measured with aerodynamic test using the Phonatory function analyzer. Closed quotients(CQ), jitter and shimmer were also investigated by electroglottography using Lx speech studio. These data were compared with that of normal controls. Results : MFR and Psub were increased on high intensity condition in all subject groups but there was no statistically significance. Statistically significant increasing of CQ. were observed in male trained singers on high intensity condition (untrained male : 51.31${\pm}$3.70%, trained male :55.52${\pm}$6.07%, p=.039). Shimmer percent, one of the phonatory stability parameters, was also decreased statistically in all subject groups(p<.001). Conclusion : The trained singers' phonation was more efficient than untrained singers. The result means that the trained singers can increase the loudness with little changing of mean flow rate, subglottic pressure but more increasing of glottic closed quotients.

  • PDF