• Title/Summary/Keyword: Sound emission

Search Result 109, Processing Time 0.069 seconds

Multi-FNN Identification Based on HCM Clustering and Evolutionary Fuzzy Granulation

  • Park, Ho-Sung;Oh, Sung-Kwun
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.2
    • /
    • pp.194-202
    • /
    • 2003
  • In this paper, we introduce a category of Multi-FNN (Fuzzy-Neural Networks) models, analyze the underlying architectures and propose a comprehensive identification framework. The proposed Multi-FNNs dwell on a concept of fuzzy rule-based FNNs based on HCM clustering and evolutionary fuzzy granulation, and exploit linear inference being treated as a generic inference mechanism. By this nature, this FNN model is geared toward capturing relationships between information granules known as fuzzy sets. The form of the information granules themselves (in particular their distribution and a type of membership function) becomes an important design feature of the FNN model contributing to its structural as well as parametric optimization. The identification environment uses clustering techniques (Hard C - Means, HCM) and exploits genetic optimization as a vehicle of global optimization. The global optimization is augmented by more refined gradient-based learning mechanisms such as standard back-propagation. The HCM algorithm, whose role is to carry out preprocessing of the process data for system modeling, is utilized to determine the structure of Multi-FNNs. The detailed parameters of the Multi-FNN (such as apexes of membership functions, learning rates and momentum coefficients) are adjusted using genetic algorithms. An aggregate performance index with a weighting factor is proposed in order to achieve a sound balance between approximation and generalization (predictive) abilities of the model. To evaluate the performance of the proposed model, two numeric data sets are experimented with. One is the numerical data coming from a description of a certain nonlinear function and the other is NOx emission process data from a gas turbine power plant.

THE USE OF THE TECHNIQUE IN BOTH CLASSICAL AND FOLK SONG IN OCCIDENTAL SINGING

  • Naidich, Susana
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.2 no.1
    • /
    • pp.15-19
    • /
    • 1986
  • Our report refers to occidental vocal techniques from Greece until today. It is remarkable that even with poor anatomy knowledge, there were advices on styles given from very early periods, for both church and secular singing. During the 18th century, the names of "vox pectoris", "vox guturris" and "vox capitis" appear, nominations that somehow remain nowadays with great confusion about source of sound production and results of resonance. Vocal occidental styles developed different kinds of requirements from the singers, that had to adapt their vocal Possibilities to them. The same happened with "pop" song. Nowadays, all kinds of singers must have a conscious knowledge of its voice management to prevent vocal disturbances. We consider that the technique is the same, even when the singer has to sing Wagner, Debussy, Sconberg, Piazzola or Gershwin. The big changes occured at resonance levels, and because these different use of the vocal resonators the effects are quite different. In summary, the big differences on classical the effects are quite different. In summary, the big differences on classical and pop song are done on the different use of the resonators and its effects on the vocal tract. "Pop" singers, men and women, should be taught to use both registers, "modal" and "falsetto" to be able to reach the complete range of their songs without any harm to their larynxes. In our opinion, a good singing technique means that it could be adapted to every stylistic need. The same technique is adapted to the popular singer as well. The main difference lays on the use of resonators, pretty strong in the classic singer, weaken in the popular singer, on the volume and on the total extension of the voice. Breathing control, effortless emission and the use of "passage" at the right point should be taught to all singers, regardless of their style. (omitted)

  • PDF

Investigation of Frozen Rock Failure using Thermal Infrared Image (열적외선영상을 이용한 동결된 암석의 파괴특성 연구)

  • Park, Jihwan;Park, Hyeong-Dong
    • Tunnel and Underground Space
    • /
    • v.25 no.2
    • /
    • pp.144-154
    • /
    • 2015
  • Mechanical energy is accumulated in the object when stress is exerted on rock specimens, and the failure is occurred when the stress is larger than critical stress. The accumulated energy is emitted as various forms including physical deformation, light, heat and sound. Uniaxial compression strength test and point load strength test were carried out in low temperature environment, and thermal variation of rock specimens were observed and analyzed quantitatively using thermal infrared camera images. Temperature of failure plane was increased just before the failure because of concentration of stress, and was rapidly increased at the moment of the failure because of the emission of thermal energy. The variations of temperature were larger in diorite and basalt specimens which were strong and fresh than in tuff specimens which were weak and weathered. This study can be applied to prevent disasters in rock slope, tunnel and mine in cold regions and to analyze satellite image for predicting earthquake in cold regions.

The Effects of Eye Lateralization on Transient Evoked Otoacoustic Emissions of Auditory Function (측방 눈 주시가 유발이음향방사 청각기능에 미치는 영향)

  • Joo, Seokhee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.4
    • /
    • pp.131-140
    • /
    • 2019
  • Purpose : The purpose of this study was to investigate the interrelationship between eye movement and auditory function through the effects of eye lateralization on transient evoked otoacoustic emissions of auditory function. Methods : 25 subjects with complete set of ears were used in this study, which composed of 12 males and 13 females with pure tone threshold of below 25 dB without otolaryngology were evaluated. Each of the patient has a visual acuity of greater than 1.0 after correction, and has no problems with eye disease, eye movement, and human parallel system. In a dark silent room, the subjects sat on a chair with their heads fixed on a headrest. The tests were performed by asking the patients to look at a fixed red light dot on a light bar in front of them. This light was directed to the front, right and left sides of the subject at an angle of 40 ° In the presence of the stimulus sound in the ipsilateral ear, the transient evoked otoacoustic emissions of the ipsilateral ear was measured at the straight, right and left fixation. In order to evaluate the transient evoked otoacoustic emissions through the efferent auditory pathway, the transient evoked otoacoustic emission values of the contralateral ear were measured at the straight, right and left fixation. These measurements were taken at frequencies of 1 kHz, 1.4 kHz, 2.0 kHz, 2.8 kHz and 4 kHz, respectively. Results : Transient evoked otoacoustic emissions caused by lateral movement of the eye showed significant changes at 1.4 KHz and 2 KHz of the afferent pathway of the ipsilateral ear. Also, significant changes were observed at 1.4 KHz and 4 KHz of the efferent pathway of the contralateral ear. Conclusion : These results indicated that there is a close relationship between eye movement and auditory cochlea. In the future, further studies considering more diverse subjects and age groups will be needed.

Development of a Laser Absorption NO/$NO_2$ Measuring System for Gas Turbine Exhaust Jets

  • Zhu, Y.;Yamada, H.;Hayashi, S.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.802-806
    • /
    • 2004
  • For the protection of the local air quality and the global atmosphere, the emissions of trace species including nitric oxides (NO and NO$_2$) from gas turbines are regulated by local governments and by the International Civil Aviation Organization. In-situ measurements of such species are needed not only for the development of advanced low-emission combustion concepts but also for providing emissions data required for the sound assessment of the effects of the emissions on environment. We have been developing a laser absorption system that has a capability of simultaneous determination of NO and NO$_2$concentrations in the exhaust jets from aero gas turbines. A diode laser operating near 1.8 micrometer is used for the detection of NO while a separated visible tunable diode laser operating near 676 nanometers is used for NO$_2$. The sensitivities at elevated temperature conditions were determined for simulated gas mixtures heated up to 500K in a heated cell of a straight 0.5 m optical path. Sensitivity limits estimated as were 30 ppmv-m and 3.7 ppmv-m for NO and NO$_2$, respectively, at a typical exhaust gas temperature of 800K. Experiments using the simulated exhaust flows have proven that $CO_2$ and $H_2O$ vapor - both major combustion products - do not show any interference in the NO or NO$_2$ measurements. The measurement system has been applied to the NO/NO$_2$ measurements in NO and NO$_2$ doped real combustion gas jets issuing from a rectangular nozzle having 0.4 m optical path. The lower detection limits of the system were considerably decreased by using a multipass optical cell. A pair of off-axis parabola mirrors successfully suppressed the beam steering in the combustion gas jets by centralizing the fluctuating beam in sensor area of the detectors.

  • PDF

Effects of Antibiotics, Copper Sulfate and Probiotics Supplementation on Performance and Ammonia Emission from Slurry in Growing Pigs (사료에 대한 항생제, 황산동 및 생균제 첨가가 육성돈의 생산성 및 슬러리의 암모니아 발생에 미치는 영향)

  • Han, Y.K.;Shin, H.T.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.537-546
    • /
    • 2005
  • An experiment was conducted to determine the effect of supplementation of chlortetracycline (CTC,110ppm), copper sulfate(Cu, 125ppm) and two levels of probiotics(Prob I, 0.04%, Prob II, 0.1%), Bacillus licheniformis and Bacillus subtilis) on growth performance, nutrient digestibility and manure characteristics in growing pigs. A total of 50 pigs that averaged 20.78$\pm$0.35kg BW and 50$\pm$2.3d age were allocated in a randomized block design with two pigs per pen and 5 pens per treatment. Pigs and feeders were weighed 10-days interval for the 40-d trials to determine ADG, ADFI and feed:gain ratio(F:G). Average daily gain, feed intake, feed/gain and nutrient digestibility were not improved(P>0.10) by the supplementation of CTC, Cu and two levels of probiotics. There were significant(P<0.05) Cu effects on digestibility of crude protein, and probiotics effects on digestibilities on organic matter, crude protein and energy between first 20 days and subsequent 20 days. Fecal concentrations of copper were highly increased(P<0.001) by the copper supplementation. Total bacteria and coliform counts were not altered by the supplementation of CTC, Cu and two levels of probiotics. Ammonia emission from slurry, measured during first 3 weeks, was reduced (P<0.001) in pigs fed diet with 125 ppm copper from copper sulfate. Results indicate that CTC, Cu and Probiotics supplementation had a little or not positive effect on grower pig performance under sound environmental conditions. Further studies may be warranted to investigate the effects of dietary copper-either reduced or in combination with dietary ammonia control agents-on the ammonia emission characteristics of swine manure.

A Temporal Trend of Dioxins Levels in Environmental Media

  • Park, Kyunghee;Daeil Kang;Junheon Youn;Lee, Choong;Sunghwan Jeon;Jingyun Na
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.05a
    • /
    • pp.148-148
    • /
    • 2003
  • This study is to investigate the environmental levels and trend of dioxins, which was the 3$\^$rd/ year of environmental monitoring research for endocrine disrupting chemicals since 1999. Total 282 samples were analyzed from 115 sites including 26 sites of airs, 43 sites of waters, 11 sites of sediments and 35 sites of soil, which were the same as those of investigated sites in 2000. Sampling period was from June 2001 to June 2002. Target chemicals were seventeen species of 2,3,7,8-chlorine-substituted PCDD and PCDF congeners and were analyzed by the standard methods, established by National Institute Environmental Research (NIER). The average concentration of dioxins in air decreased from 0.324 pg-TEQ/N㎥ in 2000 to 0.287 pg-TEQ/N㎥ in 2001, and those in water and soil were 0.073pg-TEQ/L and 1.703pg-TEQ/dry g, respectively, which was the less values detected in 2000. In sediment, however, the value was 0.086pg-TEQ/dry g, which was the increase from the value of the year 2000. The concentration range of dioxins in air for 26 sites in 17 regions detected were 0.013∼l.664pg-TEQ/N㎥, 4 sites from those were exceeded the Air Quality Standards of Dioxin in Japan (0.6 pg-TEQ/N㎥). The tolerable daily intake of dioxins was calculated at the highest level (1.664) in air, with referring the soil and food data from Japan, was calculated to be 2.85pg-TEQ/kg/day, which was below the level of 4 pg-TEQ/kg/day suggested in KFDA(Korea). While the average concentration of dioxins in 15 big cities was 0.190 pg-TEQ/N㎥, that in 8 medium/small cities constituting an industrial complex was 0.558 pg-TEQ/N㎥. In water, the concentration range detected were 0∼0.946pg-TEQ/L and the trend of the average concentrations shows an increase from those of 1999 but decreased from those of 2000, any sites however were not exceeded the Water Quality Standards of Dioxin in Japan (1 pg- TEQ/L). In soil. the detected range were 0∼43.333 pg-TEQ/dry g and the average concentration decreased, compared with the results of 2000. According to the monitoring results by land utilization, the detected range were 0∼43.333pg-TEQ/dry g in farmland, 0.017∼0.601 pg-TEQ/dry g in the industrial area, 0.005∼0.049pg-TEQ/dry g in the park and 0.008∼1.825 pg-TEQ/dry g in the rest. In sediment, the detected range increased from 0∼0.244 pg-TEQ/dry g to 0∼0.537 pg-TEQ/dry g, based on the results of 2000. For the proper control of dioxins, continuous monitoring needs to be performed and in addition, the dioxin inventory should be prepared for major sources through the dioxin emission survey. These results would provide sound and solid basis for proper decision making of dioxins management like establishment of environmental quality standards in Korea.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

A Study on Public Nuisance in Seoul, Pusan and Daegu Cities Part I. Survey on Air Pollution and Noise Level (공해(公害)에 관(關)한 조사연구(調査硏究) 제일편(第一編) : 서울, 부산(釜山), 대구(大邱) 지역(地域)의 대기오염(大氣汚染) 및 소음(騷音)에 관(關)한 비교조사(比較調査) 연구(硏究))

  • Cha, Chul-Hwan;Shin, Young-Soo;Lee, Young-Il;Cho, Kwang-Soo;Choo, Chong-Yoo;Kim, Kyo-Sung;Choi, Dug-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.4 no.1
    • /
    • pp.41-64
    • /
    • 1971
  • During the period from July 1st to the end of November 1970, a survey on air pollution and noise level was made in Seoul, Pusan and Taegu, the three largest cities in Korea. Each city was divided into 4-6 areas; the industrial area, the semi-industrial area, the commercial area, the residential area, the park area and the downtown area. Thirty eight sites were selected from each area. A. Method of Measurement : Dustfall was measured by the Deposit Gauge Method, sulfur oxides by $PbO_2$ cylinder method, suspended particles by the Digital Dust Indicator, Sulfur dioxide ($SO_2$) and Carbon Monoxide (CO) by the MSA & Kitakawa Detector and the noise levels by Rion Sound Survey meter. B. Results: 1. The mean value of dustfall in 3 cities was $30.42ton/km^2/month$, ranging from 8.69 to 95.44. 2. The mean values of dustfall by city were $33.17ton/km^2/month$ in Seoul, 32.11 in Pusan and 25.97 in Taegu. 3. The mean values of dustfall showed a trend of decreasing order of semi-industrial area, downtown area, industrial area, commercial area, residential area, and park area. 4. The mean value of dustfall in Seoul by area were $52.32ton/km^2/month$ in downtown, 50.54 in semi-industrial area, 40.37 in industrial area, 24,19 in commercial area, 16.25 in park area and 15.39 in residential area in order of concentration. 5. The mean values of dustfall in Pusan by area were $48.27ton/km^2/month$ in semi-industrial area, 36.68 in industrial area 25.31 in commercial area, and 18.19 in residential area. 6. The mean values of dustfall in Taegu by area were $36.46ton/km^2/month$ in downtown area, 33.52 in industrial area, 20.37 in commercial area and 13.55 in residential area. 7. The mean values of sulfur oxides in 3 cities were $1.52mg\;SO_3/day/100cm^2\;PbO_2$, ranging from 0.32 to 4.72. 8. The mean values of sulfur oxides by city were $1.89mg\;SO_3/day/100cm^2\;PbO_2$ in Pusan, 1.64 in Seoul and 1.21 in Taegu. 9. The mean values of sulfur oxides by area in 3 cities were $2.16mg\;SO_3/day/100cm^2\;PbO_2$ in industrial area, 1.69 in semi-industrial area, 1.50 in commercial area, 1.48 in downtown area, 1.32 in residential area and 0.94 in the park area, respectively. 10. The monthly mean values of sulfur oxides contents showed a steady increase from July reaching a peak in November. 11. The mean values of suspended particles was $2.89mg/m^3$, ranging from 1.15 to 5.27. 12. The mean values of suspended particles by city were $3.14mg/m^3$ in Seoul, 2.79 in Taegu and 2.25 in Pusan. 13. The mean values of noise level in 3 cities was 71.3 phon, ranging from 49 to 99 phon. 14. The mean values of noise level by city were 73 phon in Seoul, 72 in Pusan, and 69 in Taegu in that order. 15. The mean values of noise level by area in 3 cities showed a decrease in the order of the downtown area, commercial area, industrial area and semi-industrial area, park area and residential area. 16. The comparison of the noise levels by area in 3 cities indicated that the highest level was detected in the downtown area in Seoul and Taegu and in the industrial area in Pusan. 17. The daily average concentration of sulfur dioxides ($SO_2$) in 3 cities was 0.081 ppm, ranging from 0.004 to 0.196. 18. The daily average concentrations of sulfur dioxides by city were 0.092 ppm in Seoul, 0.089 in Pusan and 0.062 in Taegu in that order. 19. The weekly average concentration of carbon monoxides(CO) was 27.59 ppm. 20. The daily average concentrations of carbon monoxides by city were 33.37 ppm. in Seoul, 25.76 in Pusan and 23.65 in Taegu in that order. 21. The concentration of $SO_2$ and CO reaches a peak from 6 p. m. to 8 p. m. 22. About 3 times probably the daily average concentration of CO could be detected in the downtown area probably due to heavy traffic emission in comparison with that in the industial area. 23. As for daily variation of the concentration of $SO_2$ and CO it was found that the concentration maintains relatively higher value during weekdays in the industrial area and on the first part of the week in the downtown area.

  • PDF