• 제목/요약/키워드: Sound and vibration monitoring

검색결과 46건 처리시간 0.037초

구조물 음향진동 모니터링을 위한 광섬유 센서 설계 (Fiber Optic Sensor Design for the Monitoring of Structural Sound and Vibration)

  • 이종길
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.81-84
    • /
    • 2007
  • In this paper, fiber optic sound and vibration monitoring sensor which is latticed shape structure based on Sagnac interferometer is fabricated and tested in laboratory conditions. To detect external vibrations surface mounted fibers on the latticed steel wire fence with a dimension of 170cm by 180cm is used. To detect external sound frequency the tightened fiber optic itself wire netting fence with a dimension of 50cm by 50cm is used. Experiments for the detection of the excited vibration and sound signals were performed. A small vibrator induced external vibration signal and it is applied to the latticed structure in the range of 100Hz to several kHz. External sound signal applied to the fiber optic sensor net using non-directional sound speaker. The detected optical signals were compared and analyzed to the detected both accelerometer and microphone signals in the time and frequency domain. Based on the experimental results, distributed fiber optic sensor using Sagnac interferometer detected effectively external vibration and sound signal and had a good performance. This system can be expanded to the monitoring of a significant system and to the structural health monitoring system.

  • PDF

음향-진동 신호의 고차 통계해석을 이용한 회전요소 베어링의 상황감시에 관한 연구 (A Study on the Condition Monitoring for Rolling Element Bearing using Higher Order Statistical Analysis of Sound-Vibration Signal)

  • 이해철;이준서;차경옥
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.405-413
    • /
    • 2000
  • This paper present study on the application of sound pressure and vibration signals to detect the presence of defects in a rolling element bearing using a statistical analysis method. The well established statistical parameters such as the crest factor and the distribution of moments including kurtosis and skew are utilized in this study. In addition, other statistical parameters derived from the beta distribution function are also used. A comparison study on the performance of the different types of parameter used is also performed. The statistical analysis is used because of its simplicity and quick computation. Under ideal conditions, the statistical method can be used to identify the different types of defect present in the bearing. In addition, the results also reveal that there is no significant advantages in using the beta function parameters when compared to using kurtosis and the crest factor for detecting and identifying defects in rolling element bearings from both sound and vibration signals.

  • PDF

원전 복수계통 열교환기의 이음 원인 분석 (Abnormal Sound from Heat Exchanger of Condensate Water System at Nuclear Power Plant)

  • 이준신;이욱륜;김태룡
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.469-474
    • /
    • 2016
  • Abnormal sound was heard from a heat exchanger of condensate water system in a nuclear power plant, which was identified as impact sound of a loose part later. Nuclear power plants are normally equipped with loose part monitoring system for primary water system, but not for secondary water system. The abnormal sound was analyzed by using the impact signal-processing methodology based on the Hertz theory. The predicted results for impact location and size of the loose part showed good agreement with those of the actual loose part found during the overhaul period in the plant. So, this analysis methodology for the impact signal will be widely utilized for the primary and secondary side of the nuclear power plant.

3가지 음장가시화 시스템의 소개와 적용 예 (Introduction and application of three sound visualization systems)

  • 김양한;남경욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1197-1202
    • /
    • 2001
  • Near-field acoustic holography is a powerful tool to visualize sound sources. This method requires pressure measurement at many points for a good hologram. Thus one has to measure carefully so that errors due to the uncertainty of position, sensor mismatch, and so on are reduced. A method to solve this problem is to use a well-designed measurement system. This paper introduces a sound visualization system at center for noise and vibration control (NOVIC), KAIST, and addresses the advantages in terms of the error reduction. The system consists of array microphones, array jigs, a system to control the position and the velocity of the jigs, a data acquisition system, and a monitoring system. This paper also shows some sound visualization results when the system is applied to a speaker and a computer. The results verifies that the sound visualization system is useful for identifying sound sources.

  • PDF

일본 Rion 사의 휴대용 FFT 분석기, 선박 및 환경 진동계 및 휴대용 다용도 소음계의 소개 (Introduction of Handhold FFT Analyzer, Vibration Measuring Instrument of Environment and Habitability on Ship, Multi Purpose Sound Level Meter on Rion Co., Ltd.(Japan))

    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.1037-1040
    • /
    • 2004
  • Sound and vibrations enter every aspect of our daily lives. Some, like music and verbal communications, soothe and relax us; others, such as the noise and vibration from traffic or machinery, can threaten our well being. The Rion Co., Ltd. was eslablished in 1944 as an affiliate of physics and acoustic pioneer, Kobayashi Institute of Physical Research. The RION lineup affords a full line of easy-to handle measuring, recording, and analyzing equipment with innumerable applications for monitoring and maintaining a comfortable environment. RION's concern takes in all manner of sound and vibration. Our activities extend from measuring reverberation time in concert halls and testing the soundproofing characteristics of housing materials to the control and maintenance of machine noise and vibration levels.

  • PDF

간극이 있는 링크구동계의 상태진단 (Condition Monitoring of Link Driving System with Clearance)

  • 최연선;민선환
    • 소음진동
    • /
    • 제11권1호
    • /
    • pp.125-131
    • /
    • 2001
  • There is a clearance between the parts of a machine due to design tolerance, manufacturing error, wear, looseness, or misalignment. If the clearance is large, the vibration and noise of the machine is generally large. Therefore, the analysis on the nitration and noise of a machine can tell the clearance of the machine, which reveals the condition of the machine, i.e., the existence of faults and the safety of the machine. The investigation of this kind of research should be on the basis of experimental results. A link mechanism with a clearance at a joint between the coupler and locker is made for the investigation of the condition monitoring of a machine due to clearance. The vibration and sound are measured from the link driving system during the operation. The signals are clarified using line enhancement technique. The noise removed signals are used to develop the dynamic model of the system for a model based fault diagnosis. Also this study showed that the clarified signals can be used for the calculation of the joint forces between the coupler and rocker and for the correlation between the vibration and sound levels and the clearance sizes.

  • PDF

외부 음향 주파수 탐지를 위한 분포형 광섬유 센서망 설계 (Design of Distributed Fiber Optic Sensor Net for the Detection of External Sound Frequency)

  • 이종길
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.792-796
    • /
    • 2003
  • In this paper, to detect external sound frequency on the latticed structure, fiber optic sensor net using Sagnac interferometer was fabricated and tested. The latticed structure fabricated with dimension of 50cm in width and 50cm in height, the optical fiber, 50m in length, distributed and fixed on the latticed structure. Single mode fiber, a laser with 1,550nm in wavelength, 2${\times}$2 coupler were used. External sound signal applied to the fiber optic sensor net and the detected optical signals were compared and analyzed to the detected microphone signals against time and frequency domain. Based on the experimental results, fiber optic sensor net using Sagnac interferometer detected external sound frequency, effectively. This system can be expanded to the structural health monitoring system.

  • PDF

분포형 광섬유 센서망을 이용한 외부 음향 주파수 탐지 (Detection of External Sound Frequency by Using the Distributed Fiber Optic Sensor Net)

  • 이종길
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.569-576
    • /
    • 2004
  • In this paper, to detect external sound frequencies on the latticed structure, fiber optic sensor net using Sagnac interferometer was fabricated and tested. The latticed structure was fabricated with a dimension of 50 cm in width and 50 cm in height. The optical fiber of 50m in length was distributed and fixed on the surface of the latticed structure. Single mode fiber, a laser with 1,550 nm in wavelength, 2 ${\times}$ 2 coupler were used. External sound signal, 240 Hz, 495 Hz, 1.445 kHz, 2k Hz, applied to the fiber optic sensor net and the detected optical signals were compared to the detected microphone signals against time and frequency domains. Based on the experimental results, fiber optic sensor net using Sagnac interferometer detected external sound frequency, effectively. This system can be expanded to the structural health monitoring system.