• Title/Summary/Keyword: Sound absorptive materials

Search Result 18, Processing Time 0.024 seconds

Characteristics of Absorption Performance of Sound Absorptive Materials according to Test Conditions (흡음재의 시험조건에 따른 흡음성능 특성)

  • Kang, Dae-Joon;Lee, W.S.;Lee, J.W.;Hong, J.K.;Jo, Y.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.7 s.112
    • /
    • pp.683-689
    • /
    • 2006
  • The sound absorption materials have been used to enhance the performance of a noise barrier and improve the room acoustics. In this study, 6 products of sound absorption materials generally used in Korea were chosen, and their absorption performance was tested in various conditions, that is, it was measured while changing thickness, density and air-gap in their back, and measured with or without facing on their face.

A Study on the Sound Transmission Loss Measurement of Sound Isolation Sheets (차음시트의 음향투과손실 측정에 관한 연구)

  • Lee, Dong-Hoon;Kang, Moon;Lee, Ju-Weon;Jung, Gab-Cheol;Kwon, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.409-414
    • /
    • 2000
  • A new impedance tube method is presented for the measurement of transmission loss of sound isolation sheets. The two-microphone method based on the sound decomposition theory proposed by Seybert and Ross is reviewed in this impedance tube method, which has been used for the determination of absorption coefficient of absorptive materials as well as transmission loss of automotive mufflers. Sound transmission losses for rubber, polyvinyl and asphalt sheets are measured in an impedance tube and reverberation room facility, respectively. By comparing two measurement methods, the reliability of impedance tube method used in this study is validated. From the experimental results, it is shown that the accuracy of sound isolation capability obtained by the impedance tube method depends upon the microphone spacing and the distance of the first microphone from the test sample surface.

  • PDF

Design and Measurement of Dissipative Silencers for Noise Reduction of Large Maritime Gas Turbine Engines (해상용 대형 가스터빈의 소음 저감을 위한 흡음형 소음기의 설계 및 성능 측정)

  • Baek, Seonghyeon;Lee, Kanghee;Gwon, Daehun;Lee, Iljae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.367-371
    • /
    • 2014
  • Based on ISO 7235, an experimental setup to measure the acoustic performance of splitter type dissipative silencers are fabricated. The length of each duct, sound source, microphone locations, modal filter, and anechoic termination are considered in the design of this setup. The modal filter is a particularly important factor because it affects the limit of measurement, which is also determined by the amount of flanking transmission of sound generated by the sound source to microphones. The effects of absorptive materials, media which covers the materials, and the number of splitters on the noise reduction of the sample silencers are experimentally investigated. The insertions loss of silencers with media and higher number of splitters increases, especially at higher frequencies.

  • PDF

Comparison of Absorption Coefficient according to Test Methods (시험방법에 따른 흡음률 비교)

  • Lee, J.W.;Gu, J.H.;Park, H.K.;Kang, Dae-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.5 s.122
    • /
    • pp.373-378
    • /
    • 2007
  • Today, the use of the sound absorptive material is increasing to improve the room acoustics in the auditorium and music hall, etc. Usually, the sound absorption materials have been used to enhance the performance of a noise barrier and improve the room acoustics in construction site. Generally, the sound absorbtion coefficients are the most important factor reflecting the sound absorbtion performance. There are two methods to measure the sound absorption coefficient. The first one is the reverberation room method, and the second is the impedance tube method. In this study, we measure the sound absorbtion coefficients using these two methods, and then we compared the results of the sound absorbtion coefficients to look into the difference of results between reverberation room method and impedance tube method. Also we compared the results of the sound absorbtion coefficients with respect to the size of sample and the volume of reverberation room. From the experiment, we could see that the sound absorbtion coefficients are measured equally for different sample size. But the sound absorbtion coefficients are measured differently according to test methods and test conditions.

An Experimental Study on the Absorption Property of Slit Absorbers with Composite Details

  • Jeong, Dae-Up;Joo, Moon-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2E
    • /
    • pp.81-90
    • /
    • 2002
  • Single absorbing materials and Helmholtz resonators have limited absorption characteristics over limited frequency ranges due to their structures and properties. Porous materials are highly absorptive for mid and high frequency ranges, while they have little sound absorption for low frequency sounds. Helmholtz resonators are generally used to absorb sound energy for a specified frequency range. Hence they have limited capability in controlling the overall acoustic properties of a space. Not much has been known about useful finishing materials which have enough rigidity and absorption over broad frequency range, in spite of wide demands from acoustic designers and consultants. The present work measured and analyzed absorption characteristics of a slit absorber by varying surface materials, depths of air gap, dimensions of slat and slit widths. It was found that the narrower the slit width, the larger the absorptions over the wide frequency ranges and the pattern was dependent on the presence of porous material. Narrower slat's width tend to increase the slit absorber's absorption more or less. Absorption coefficients at low frequency ranges were dramatically improved (from 0.23 to 0.56) by increasing air gap when porous materials were present.

Nonlinear Impedance Characteristics of Helmholtz Resonator with Tapered Neck (경사진 목을 가지는 헬름홀쯔 공명기의 비선형 임피던스 특성)

  • Seo, Sang-Hyeon;Chung, Hoe-min;Kim, Yang-hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.75-80
    • /
    • 2012
  • Helmholtz resonator is widely used acoustic instrument which has high absorption characteristics at its resonance frequency. Particularly it maintains good performance even in the low frequency region that is difficult to control by general porous absorptive materials. However, under severely high sound pressure level, the absorption characteristics are changed by increase of resistance due to nonlinear behavior of neck impedance. Because of this nonlinear behavior, it is difficult to obtain the expected absorption performance under high sound pressure environment. Thus, in order to prevent excessive rise of resistance, the resonator with neck having cross section dimension decrease away from the entry of the resonator cavity could be suggested. This paper introduces the experiment method and results about nonlinear characteristics of Helmholtz resonator with tapered neck and proposes the approximate nonlinear impedance model.

  • PDF

Interior surface treatment guidelines for classrooms according to the acoustical performance criteria (학교 교실의 음환경 기준에 따른 실내마감 방안)

  • Ryu, Da-Jung;Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.2
    • /
    • pp.92-101
    • /
    • 2016
  • There are many results in which acoustical conditions of a classroom play an important role for studying effects and academic achievement of students. However, there are very few guidelines or design proposals which could make appropriate acoustic environment when classrooms are built or renovated. The present study suggests various design proposals satisfying acoustic standards of classrooms based on theoretical calculation and acoustic field experiments. At first, minimum area of sound absorption was calculated which is required to satisfy the acoustic standard for domestic middle and high schools. Also, room acoustic measurements were carried out in order to investigate the acoustic performance of an existing classroom by changing interior finishing materials on ceiling and rear walls. As a result, it was revealed that reverberation time standard below 0.8 s can be acquired even if there is no sound absorption on ceiling which is a general practice executed in Korea. Specially, it was found that if partial area of ceiling would be treated as reflective with the ratio of sound absorption and reflection as 2:1, almost similar acoustic parameters of $C_{50}$, $D_{50}$, RASTI (Rapid Speech Transmission Index) and higher sound levels could be acquired in comparison with the case of entire sound absorption on ceiling.

Noise Analysis and Reduction Methods of the All-in One Window Ventilation System (창호일체형 환기장치의 소음분석 및 저감방안)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.43-55
    • /
    • 2013
  • The window ventilation system based on the heat recovery device was developed which make air ventilation possible without opening the windows. However, mechanical and aerodynamic noises were come to pass which annoyed people in rooms. In the present study, noise of new window ventilation system was measured in both general room and anechoic chamber. Also, the noise path was detected to find cause of noise generation and vulnerable area of the device. Sound absorptive and insulation materials were applied to mitigate the noise. Finally, an alternative noise control method was suggested which can satisfy with the indoor noise standards. As a result, it was shown that the cause of noise was the low transmission loss in the ventilation system. As a result, it was shown that the main noise source of the ventilation system was the blower and the major cause of noise was the low transmission loss of the ventilation system. It is also concluded that the noise levels complies with the noise standards of 40 dBA when 2 mm rubber sheet is applied inside the ventilation system.