• Title/Summary/Keyword: Sound absorbing panel

Search Result 27, Processing Time 0.023 seconds

A Study on Performance Improvement of Sound Absorbing Noise Barrier (흡음형 방음벽의 성능향상에 관한 연구)

  • 김현실;김재승;강현주;김봉기;김상렬
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.849-854
    • /
    • 2001
  • A study on performance of the sound absorbing noise barrier is presented. Noise barrier of sound absorbing type is composed of the front panel, sound absorbing material, and back panel. For allowing sound path, front panel is usually perforated. The performance of the noise barrier is governed by the opening ratio of the perforated panel, sound absorption coefficient of the sound absorbing material. In this study, the effects of the opening ratio, diameter of the hole, thickness of the sound absorbing material are investigated. It is found that the thickness of the sound absorbing material must be at least 50 mm to ensure the required minimum NRC value 0.70, and the opening ratio is greater than 0.2. It is shown that the thickness of the back panel is crucial in providing required STL (Sound Transmission Loss) value. The performance of the developed noise barrier is measured, where its sound absorbing coefficient and sound transmission loss satisfy the criteria.

  • PDF

Investigation of Sound Absorbing Characteristics of the Railway Noise Barrier by Changing the Configuration of the Front Perforated Panel and Absorbing Material (철도 방음벽의 전면 타공과 흡음재에 의한 흡음성능 고찰)

  • Kim, Kwanju;Kim, Sanghun;Park, Jinkyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.575-580
    • /
    • 2013
  • This study focused on the identification of sound characteristics according to the configuration of sound absorption material and perforated panel dimensions. Noise barriers consist of front perforated panel, sound absorption material and back plate. Noise barriers' acoustic performance should be required to meet the NRC of 0.7. The absorbing performance of the noise barrier relies on the opening ratio of perforated panel and the efficiency of the absorbing material. This study try to find out the possibilities of applications to railway usage.

  • PDF

A Study on the Improvement of Acoustic Absorption of Multiple Layer Perforated Panel Systems (다중 다공판 시스템의 흡음성능 향상에 관한 연구)

  • Lee, Dong-Hoon;Seo, Seong-Won;Hong, Byung-Kuk;Song, Hwa-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.5 s.98
    • /
    • pp.571-577
    • /
    • 2005
  • The acoustic absorption of multiple layer perforated panel systems is largely reduced at the anti-resonance frequency. In order to improve the acoustic absorption at the anti-resonance frequency, the sound absorbing materials are inserted between perforated panels. By the insertion of absorbing materials, it is found that the multiple layer perforated panel system has better acoustic absorption at the anti-resonance frequency and more broadband frequency. Besides, it is shown that the absorption coefficients from the transfer matrix method agree well with the values measured by the two-microphone impedance tube method for various combinations of perforated panels, airspaces or sound absorbing materials.

Sound Absorbing Characteristics According to Interior Configuration of Noise Barrier (흡음형 방음벽의 내부 구성에 따른 흡음특성)

  • 박진규;김상헌;김관주;박희준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.387-392
    • /
    • 2003
  • This study is put a focus on the identification of sound characteristics according to the interior configuration of sound absorption material and air gap. Noise barrier is general consists of front perforated panel, air layer, sound absorption material, air gap and back plate. Noise barrier is required to the NRC value of 0.7. The absorbing performance of the noise barrier relies on the opening ratio of the perforated panel and the efficiency of the absorbing material. This study has observed the effect of opening ratio and hole size, the increase of sound absorbing performance by the configurations of sound absorption material and air gap. New designed noise barrier is achieved the acoustical performance of 0.87 the measurement in a reveration room.

  • PDF

A Study of Sound Absorbing Characteristics of the Railway Noise Barrier with Respect to Front Perforated Panel and Absorbing Material (철도 방음벽의 전면 타공과 흡음재 변화에 의한 흡음성능 고찰)

  • Kim, Kwanju;Lee, Junheon;Kim, Sanghun;Park, Jinkyu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.4
    • /
    • pp.275-281
    • /
    • 2014
  • This study has been analyzed the sound performance of the noise barriers with respect to the configuration of the front perforated panel geometries and the filled absorption materials. Noise barriers' acoustic performance should be required to meet 0.7 of NRC value at least. The global absorbing performance of the barriers have been investigated by changing the opening ratio of the front perforated panel and the absorbing characteristics of the absorbing material using two microphone method. Therefore, It it possible to obtain to increase acoustic performance of the specific frequency ranges by designing the perforate rates of the front panel and absorbing characteristics of the absorbing materials inside, as well. This study try to find out the possibilities of applying the absorbing noise barrier to railway usage.

Developments of monitoring system to measure sound absorbing coefficient and structural stability of sound absorbing panel on the concrete track in the urban train tunnel (도시철도 터널 내부 콘크리트 도상 국소공명흡음판의 흡음계수 및 구조안정성 평가를 위한 계측시스템 개발)

  • Oh, Soon-Taek;Lee, Dong-Jun;Lee, Dong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • In this study, a test-bed system simulated a tunnel and concrete track is tested on cite and invested an allowed limit of multi-layered sound absorbing panel for reducing noise reflected on the concrete track in train tunnel considering the criteria and limitation on the theoretical back ground. The studied results are an effective evaluating system of the sound absorbing coefficient influenced fluid effects depending on the vehicle speed in the urban train tunnel and measuring not only structural behaviors of maximum displacement and acceleration of the panel but also dynamic characteristics of damping ratio and natural frequency.

Absorption Characteristics of Perforated Environment Friendly Sound Absorbing Board using Hwangto (황토를 이용한 친환경 유공 흡음보드의 흡음특성)

  • Kim, Sun-Woo;Park, Hyeon Ku
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.3-8
    • /
    • 2011
  • Sound absorbing materials used for lightweight panels and interior material are mainly made of fibroid material such as glass wool or rock wool. However these fiber type sound absorbing materials have some problems such that sound absorption could be decreased as time goes by because of durability. In addition, dust scattering from fiber type material can cause another problem in health. In this point of view, this study aims to develop environment friendly sound absorbing material using Hwangto(so called loess or yellow soil), a traditional housing material. Hwangto is natural housing material in Korea and generally known for improving indoor air quality. Hwangto panel is made to construct on the floor, wall and ceiling, and expected that there is not enough absorption. Present study tried to develop environment friendly sound absorbing material that has high sound absorption performance with good environment performance in terms of air quality. Pore rate was designed to maximize the absorption in the specific frequency bands, and two kinds of backing space were applied in order to see the effect of backing space. As a result peak frequency that has maximum absorption is going high as the pore rate is increased. The backing space provides more absorption and makes the peak frequency down to low.

Noise Barrier Design for Increased Sound Absorption (흡음률 증가를 위한 방음벽 구조)

  • Kim Hyun-Sil;Kim Jae-Seung;Kang Hyun-Joo;Kim Bong-Ki;Kim Sang-Ryul
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.367-370
    • /
    • 2001
  • Various shapes of the noise barrier frame and construction of the sound absorbing panels are studied. It is found that insertion of the sound absorbing panel into barrier frame results in the decrease of the sound absorption coefficient, while the empty frame shows a peak around 250Hz. Using double sound absorbing panels with air gap can increase sound absorption coefficient up to NRC 0.85.

  • PDF

Developing Sustainable Inorganic Sound-Absorbing Panel Mixtures Using Industrial Waste (산업폐기물을 활용한 무기계 흡음 패널 개발 기초 연구)

  • Cheulkyu Lee;Seongwoo Gwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.501-508
    • /
    • 2023
  • Addressing urban noise problems, this study develops eco-friendly, inorganic sound-absorbing panels, overcoming the limitations of traditional PMMA and cement-based panels. These conventional panels pose safety risks due to flammability and environmental concerns due to carbon emissions. Utilizing industrial waste, the research comprises two phases: initial tests for physical and performance characteristics (fluidity, density, compressive strength, sound absorption) and subsequent development of optimized panel mixtures. This approach aims to replace existing panels with sustainable, effective alternatives, significantly contributing to safer, environmentally responsible urban infrastructure. The findings of this study have implications for the sound panel market, offering novel solutions for noise control while aligning with environmental and safety standards.

A Helmholtz Resonator Array Panel for Low Frequency Sound Absorption (저주파수 흡음을 위한 헬름홀쯔 공명기 배열형 패널)

  • Kim, Yang-Hann;Kim, SangRyul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.8 s.101
    • /
    • pp.924-930
    • /
    • 2005
  • Sound absorptive materials have good performance in high frequency range, not at low frequencies. Therefore it has been great challenge to develop a sound absorbing structure that is good at low frequency. We propose to use a Helmholtz resonator array panel for this purpose. A Helmholtz resonator is one of noise control elements widely used in many practical applications. The resonator is a simple structure composed of a rigid-walled cavity with a neck, but it has very high performance at resonance frequency. This paper discusses the sound absorption of Helmholtz resonator array panels at normal and random incidence. First, various experimental results are introduced and studied. Secondly, we theoretically predict the absorptive characteristics of the resonator away panel. The theoretical approach is based on the Fourier analysis for a periodic absorber. We believe that this method can be used to design a panel for low frequency noise control.