• Title/Summary/Keyword: Sound Transmission Class

Search Result 16, Processing Time 0.016 seconds

A study on wideband underwater acoustic signal amplifier design for generating multi-frequency (다중 주파수 재생을 위한 광대역 수중 음향 신호 증폭기 설계 연구)

  • Lee, Dong-Hun;Yoo, Seung-Jin;Kim, Hyeong-Moon;Kim, Hyoung-Nam
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.3
    • /
    • pp.179-185
    • /
    • 2017
  • The problem that occurred in the design/fabrication/testing of the wideband transmitting power amplifier for an embedded active SONAR (Sound Navigation and Ranging) system operating underwater was analyzed and the solution of the problem was proposed in this paper. Wideband acoustic SONAR systems had been developed in order to improve the underwater detection performance. The underwater acoustic transmission system had been also developed to achieve the wideband SONAR system. In this paper, the wideband acoustic transmission signal was generated using a 2 Level sawtooth type Class D PWM (Pulse Width Modulation) which was not complicated to implement. When the sonar signals having two or more frequencies were simultaneously generated, parasitic frequencies were added to the original signals by integer multiples of the frequency difference of the original signal. To cope with this problem, we proposed a way to remove the parasitic frequency from the source signal through modeling and simulation of the implemented power amplifier and PWM control hardware using MATLAB and Simulink.

Measurement and evaluation of speech privacy in university office rooms (대학 내 사무실의 스피치 프라이버시 측정 및 평가)

  • Lim, Jae-Seop;Choi, Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.396-405
    • /
    • 2019
  • The speech privacy of closed office rooms located in a university campus was measured and assessed in terms of SPC (Speech Privacy Class) values. The measurements of two quantities, the LD (Level Difference) between a source and a receiving room, and the background noise level ($L_b$) at the receiving room were carried out in 5 rooms located in 3 different buildings in the university campus. Each of the 5 rooms was adjacent to both offices and corridors through walls. The TL (Transmission Loss) between the source and the receiver room was also measured to compare the difference of two standard methods, ASTM E2836-10 and KS F 2809. The present results show that the speech privacy of the 5 office rooms is not met the requirement for a minimum SPC values of 70. A minimum LD value of 41 dB between the source and the receiver room should be achieved for having a SPC value of 70 when the mean measured value of $L_b$ at the receiving room is 29.2 dB. That is, the TL(avg) value averaged over the octave bands from 160 Hz to 5000 Hz between the source and the receiver room should be or greater than 40 dB. The most important architectural factor influencing the LD value is the presence of openings, such as doors, and windows, on the adjacent walls between the source and receiving room. Therefore, if the opening of the adjacent wall is replaced by an opening with high sound insulation, the appropriate SPC value of the research and office rooms can be achieved.

The study on the management method and installation guide of temporary noise barrier (가설방음벽의 운영방안 및 설치기준에 관한 연구)

  • Yoon, Je-Won;Kim, Young-Chan;Kang, Hee-Man;Jang, Tae-Soon;Lee, Ki-Jung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.372-375
    • /
    • 2006
  • 건설 공사장에서 발생하는 건설장비의 소음을 저감하여 공사장 인근 지역의 생활환경에 미치는 소음영향을 최소화할 수 있도록 건설업체에서는 최대한의 노력으로 가설방음벽을 설치 운영하고 있으나, 설치된 가설방음벽의 효과분석 및 운영방법에 대한 검토가 부족하여 효율적인 소음저감대책으로서의 가설방음벽 운영이 어려운 실정이다. 따라서, 본 연구에서는 가설방음벽의 기초데이터의 확보와 소음해석을 통한 효율적인 운영방안을 제시하며, 설치기준에 관한 방안을 제시하고자 한다.

  • PDF

A Study on the KS Standardization of Test Rooms for the Measurement of Sound Insulation in Buildings and. of Building Elements (건물 및 건물부재의 차음성능 측정을 위한 표준 측정실의 KS 규격화에 관한 연구)

  • Oh, Yang-Ki;Kim, Heung-Sik;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.336-339
    • /
    • 2000
  • Revision of KS, Korean Standards, is currently actively discussed. It is just the time for a new world class standards under the new system with WTO, World Trade Organization. This paper is a part of "Researchs on the Standards in the Building Acoustic Field", as one of KS revision projects. The aim of this study is to define the requirements of laboratory test facilities with suppressed flanking transmission. In the former KS, there is no items matched with this purpose. Therefore comparing several results with different measuring conditions of a laboratory and results between different laboratories was impossible. On these basis, a new part of KS is proposed, and some problems remained and further discussions in the proposed draft are described in this study.

  • PDF

Electronic Attendance System Using Smart Device and High Frequency Signal

  • Myoungbeom Chung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.11
    • /
    • pp.103-111
    • /
    • 2023
  • Recently, many universities have used various electronic attendance systems such as NFC, QR code, Sound-QR, Bluetooth BLE authentication, and face recognition to process attendance. However, existing methods have various problems such as attendance errors due to deformation of authentication signals, mis-recognition attendance from outside the classroom, and difficulty to process seat absence during class. Therefore, this study proposes a high-frequency signal-based electronic attendance system to solve these problems and manage more accurate electronic attendance. As the high-frequency signal replaces the BLE signal, and the transmission range of the signal is limited to the classroom, and the signal value can be immediately changed if a change of the signal is needed. To verify the performance of the proposed system, we conducted a comparative experiment with the Bluetooth based electronic attendance system, and as a result, the proposed method showed high accuracy. Thus, the proposed method will be a useful service that can be immediately used in smart device-based electronic attendance system.

A Noise Prediction of Floating, Production, Storage and Offloading(FPSO) (부유식 석유생산.저장.하역선박의 소음해석)

  • Kim, Young-Hyun;Kim, Dong-Hae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.307-310
    • /
    • 2000
  • Recently, the demand for the Floating, Production Storage, and Offloading facility(FPSO) which has some economic and technical advantages, has increased in offshore oil production areas. The basic characteristics of a 343,000 DWT class FPSO which is being built in Hyundai Heavy Industries and shall be installed in offshore Angola, is almost same as that of oil carriers. However, she do not have self-propulsion system, but has additional facilities for oil production and positioning system. Main noise source contributing to the cabin noise of the accommodation, are classified into the machine in the engine room and the deckhouse, HVAC system, and the topside equipments. In general, the noise regulation for the offshore structure is much severer than that of the common commercial ships and the maximum acceptable sound pressure level of cabins is specified in 45dB(A). This paper describes the procedure of noise analysis along with its results. Noise analysis has been carried out for the case of emergency diesel generator running condition and the case of normal production condition and the results has been compared with the measurement results of the first case. Based on the results, proper countermeasures to reduce excessive noise level has been applied considering the characteristics of sources and receiver spaces and can be satisfied the specifications at all spaces.

  • PDF