• Title/Summary/Keyword: Sound Ray

Search Result 158, Processing Time 0.023 seconds

THYMOLIPOMA(Report of one case) (흉선지방종-1례 보고-)

  • 백승환
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.561-565
    • /
    • 1990
  • We experienced thymolipoma which is a rare benign mediastinal tumor, an admixture of atrophic thymic tissue and matured adipose tissue. The patient was, 13 years old boy, admitted due to anterior mediastinal mass on routine chest X-ray and complained of mild exertional dyspnea. The physical examination revealed percussion dullness, decreased breathing sound at right anterior hemithorax. The chest PA and lateral views showed both paracardiac mass density and obliteration of retrosternal clear space. The chest CT Scan showed tubular structure containing of thymic tissue and enhanced fatty tissue, suggested thymolipoma. Operation was performed under the impression of thymolipoma. Through median sternotomy, the huge mass was resected. Grossly, the mass was yellowish fatty colored, measured 15X12X10cm, weighed 600gm. Light microscopic examination showed that thymic tissue containing of Hassal`s corpuscles were surrounded by matured adipose tissue, as the characteristic finding of thymolipoma. The postoperative course was uneventful.

  • PDF

Numerical modeling and simulation technique in time-domain for multibeam echo sounder

  • Jung, Donghwan;Kim, Jeasoo;Byun, Gihoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.2
    • /
    • pp.225-234
    • /
    • 2018
  • A Multibeam Echo Sounder (MBES) is commonly used for rapid seafloor mapping. We herein present a time-domain integrated system simulation technique for MBES development. The Modeling and Simulation (M&S) modules consist of four parts: sensor array signal transmission, propagation and backscattering modeling in the ocean environment, beamforming of the received signals, and image processing. Also, the simulation employs a ray-theory-based algorithm to correct the reconstructed bathymetry, which has errors due to the refraction caused by the vertical sound velocity profile. The developed M&S technique enables design parameter verification and system parameter optimization for MBES. The framework of this technique can also be potentially used to characterize the seabed properties. Finally, typical seafloor images are presented and discussed.

The Effect of Joint Space Pumping Treatment in Patients with Reducible Disc Displacement Accompanied by TMJ Sound and Pain (악관절잡음 및 동통을 동반한 정복성 관절원판 변위환자에 대한 관절강 Pumping 효과)

  • Kim, Hyeon-Cheol;Choi, Jong-Hoon;Park, Hye-Suk;Kim, Chong-Youl
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.1
    • /
    • pp.9-24
    • /
    • 1999
  • Pumping into the upper joint cavity of the TMJ was done on patients who had reducible disc displacement with pain. This article discusses the change in TMJ sounds before and after the Pumping treatment. 20subjects(mean age of $32.1{\pm}10.2yr$)were selected among those who visited the department of Oral Medicine of Yonsei University for the treatment of craniomandibular dysfunctions. Through a thorough history taking, clinical exam and X-ray taking these subjects were diagnosed as reducible disc displacement patients, and they were subdivided into two groups as acute and chronic according to the time the TMJ sound was made. Sonopak was used to measure the TMJ sound before, right after and one-week after the Pumping treatment. VAS was used to measure the degree of subjective TMJ complaints(sounds and pain) before and one-week after the Pumping treatment. Vibration related items included total integral, high integral, low integral, ratio of high integral to low integral, peak amplitude, peak frequency and median frquency. 1. It was not statistically significant between the acute and chronic groups before the treatment. However, total integral, high integral, low integral, peak amplitude, peak frequency, median frequency showed to be greater in the chronic group. 2. In all the subjects, just after the Pumping treatment was done, total integral, high and low integral, peak amplitude and peak frequency significantly decreased (p<0.05). Even after one week, low integral, peak frequency and median frequency significantly decreased (p<0,05), and the TMJ sound diminished accordingly. 3. Comparing the two groups(before and right after the Pumping treatment), there was the following difference ; in the acute group, high integral, high amplitude, high frequency and median frequency significantly decreased(p<0.05). In the chronic group, total integral, high integral, low integral, ratio, peak amplitude and peak frequency significantly decreased(p<0,05). It was not statistically significant between the acute and chronic group. 4. Comparing the two groups(right after and one week after the Pumping treatment), there was the following difference : in the acute group, high integral, high amplitude, high frequency and median frequency significantly decreased(p<0.05), In the chronic group, low integral significantly decreased(p<0.05). However, although it was not statistically significant, after one week, there was an increase in total integral, ratio, peak amplitude and peak frequency compared to right after the treatment group. 5. In the VAS of before and one week after the Pumping treatment of the TMJ pain and sound, the TMJ pain significantly decreased(p<0.05) in both the acute and chronic group. However, it was not statistically significant between the two groups. There was a statistically significant decrease(p<0.05) in the TMJ sound in the acute group after one week of Pumping treatment, but no change was notable in the chronic group and it was not statistically significant between the two groups. From the above results, we can conclude that Pumping into the upper joint cavity of patients having reducible disc displacement is effective in reducing clicking and pain. Therefore, it can be applied in diverse clinical fields.

  • PDF

An Algorithm for Submarine Passive Sonar Simulator (잠수함 수동소나 시뮬레이터 알고리즘)

  • Jung, Young-Cheol;Kim, Byoung-Uk;An, Sang-Kyum;Seong, Woo-Jae;Lee, Keun-Hwa;Hahn, Joo-Young
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.472-483
    • /
    • 2013
  • Actual maritime exercise for improving the capability of submarine sonar operator leads to a lot of cost and constraints. Sonar simulator maximizes the capability of sonar operator and training effect by solving these problems and simulating a realistic battlefield environment. In this study, a passive sonar simulator algorithm is suggested, where the simulator is divided into three modules: maneuvering module, noise source module, and sound propagation module. Maneuvering module is implemented in three-dimensional coordinate system and time interval is set as the rate of vessel changing course. Noise source module consists of target noise, ocean ambient noise, and self noise. Target noise is divided into modulated/unmodulated and narrowband/broadband signals as their frequency characteristics, and they are applied to ship radiated noise level depending on the vessel tonnage and velocity. Ocean ambient noise is simulated depending on the wind noise considering the waveguide effect and other ambient noise. Self noise is also simulated for flow noise and insertion loss of sonar-dome. The sound propagation module is based on ray propagation, where summation of amplitude, phase, and time delay for each eigen-ray is multiplied by target noise in the frequency domain. Finally, simulated results based on various scenarios are in good agreement with generated noise in the real ocean.

Noise Protection Roof: Partial Opening Effect for Noise Reduction (철도용 터널형 방음벽 개발연구: 설계 방향)

  • Kim, Tae-Min;Kim, Jeung-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.6
    • /
    • pp.522-532
    • /
    • 2015
  • In the present study, a tunnel type soundproof wall with partial opening is proposed to reduce the environmental noise caused by railway vehicles traveling on bridges, which affects residents of high-rise apartment buildings; the study also attempts to minimize load due to wind and the weight of the wall. Applying the principles of computational fluid dynamics and structural mechanics, and the ray tracing method, a reduction in noise as well as of the overall weight of the soundproof walls is estimated. Analysis results show that the proposed soundproof wall with a partial opening weighs less, while reducing the wind loading by up to 30%. To prevent direct propagation of sound through openings in the wall, an acoustic louver, which is a type of silencer, could be considered for the opening. In order to achieve a similar noise effect with existing insulation material, the fluid flow and the insulation effect of the acoustic louver are analyzed. As the considered opening is in the range of 30~40% of the total length of the soundproof wall, the noise effect and wind load are reduced by 10dB and 25% respectively. Consequently, opening some part of tunnel type soundproof walls and installing louvers on the wall openings can have the effects of weight-reduction and reduced wind load. If a partial opening is applied with proper sound material application, a gain of an additional 5~10dB of noise reduction can be achieved.

DIGITAL IMAGE PROCESSING AND CLINICAL APPLICATION OF VIDEODENSITOMETER (실험적으로 제작한 Videodensitometer의 디지털 영상처리와 임상적 적용에 관한 연구)

  • Park Kwan-Soo;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.273-282
    • /
    • 1992
  • The purpose of this study was to propose the utility which was evaluated the digital image processing and clinical application of the videodensitomery. The experiments were performed with IBM-PC/16bit-AT compatible, video camera(CCdtr55, Sony Co., Japan), an color monitor(MultiSync 3D, NEC, Japan) providing the resolution of 512×480 and 64 levels of gray. Sylvia Image Capture Board for the ADC(analog to digital converter) was used, composed of digitized image from digital signal and the radiographic density was measured by 256 level of gray. The periapical radiograph(Ektaspeed EP-21, Kodak Co., U. S. A) which was radiographed dried human mandible by exposure condition of 70 kVp and 48 impulses, was used for primary X-ray detector. And them evaluated for digitzed image by low and high pass filtering, correlations between aluminum equivalent values and the thickness of aluminum step wedge, aluminum equivalent values of sound enamel, dentin, and alveolar bone, the range of diffuse density for gray level ranging from 0 to 255. The obtained results were as follows: 1. The edge between aluminum steps of digitized image were somewhat blurred by low pass filtering, but edge enhancement could be resulted by high pass filtering. Expecially, edge enhancement between distal root of lower left 2nd molar and alveolar lamina dura was observed. 2. The correlation between aluminum equivalent values and the thickness of aluminum step wedge was intimated, yielding the coefficient of correlation r=0.9997(p<0.00l), the regression line was described by Y=0.9699X+0.456, and coefficient of variation amounting to 1.5%. 3. The aluminum equivalent values of sound enamel, dentin, and alvolar bone were 15.41㎜, 12.48㎜, 10.35㎜, respectively. 4. The range of diffuse density for gray level ranging from 0 to 255 was wider enough than that of photodenstiometer to be within the range of 1-4.9.

  • PDF

Effect of Higher Order Form Factors on the Prediction of Room Acoustics by Extended Radiosity Method (확장 라디오시티법에 의한 실내음향 예측에 있어 고차 형태 계수의 영향)

  • 이희원;고일두;오양기;두세진;정대업
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.7-13
    • /
    • 2003
  • Numerous investigations have demonstrated that diffused reflection is one of the most important factors in predicting room acoustics by computer simulation. Recent studies have suggested several computational algorithms in order to account for diffused reflections in the ray tracing or beam tracing method. In this study, a computational algorithm for the calculation of diffuse sound reflections in the image method is suggested and a computer simulation system is developed based on the suggested algorithm. The methodology adopted in our computer simulation system is similar to the extended radiosity method, which is developed for the computer graphics. In a real room, sound energy is reflected in a partially diffused manner which results in four reflection combinations: diffuse-diffuse, specular-specular, diffuse-specular and specular-diffuse. In this study, higher order form factor is introduced to handle the four types of reflection combinations so that the partially diffused reflection could be modeled. In this paper, the concept of extended radiosity method is described and the approximate method of calculating higher order form factor is suggested. Finally, the effect of higher order form factors on the simulation of reverberation time is investigated.

REMINERALIZATION DEPTH OF CPP-ACP ON DEMINERALIZATION HUMAN ENAMEL IN VITRO (탈회된 법랑질에서 CPP-ACP의 재광화 깊이)

  • Choi, Han-Ju;Choi, Yeong-Chul;Kim, Kwang-Chul;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.278-286
    • /
    • 2008
  • Many studies regarding Casein phosphopeptides-amorphous calcium phosphate(CPP-ACP) have demonstrated the remineralization ability on the demineralized enamel surface. A question is still remained that how deep can the calcium (Ca) and phosphorus (P) ions supplied by the CPP-ACP paste penetrate into the enamel subsurface. The aims of this study were to measure the penetrating depth of Ca and P ions in the demineralized human enamel in vitro, and were to determine the amount and depth of Ca and P ions according to the duration. The amount and depth of Ca and P ions were measured by microscopic observation with Field Emission Scanning Electron Microscopy (FE-SEM; LEO SUPRA 55, Carl Zeiss, Germany) and Energy Dispersive X-ray Spectrometer (EDS; GENESIS 2000, EDAX, USA: Linescan of Calcium and Phosphorus). Freshly extracted four human 1st premolars were obtained from the Dept. of Pediatric Dent., Kyung Hee Univ. Buccal surfaces of the 1st premolars were covered with nail varnish to form a window on the middle third of buccal surface. All of the teeth with enamel windows were immersed in a solution of 0.1 M lactic acid, Carbopol C907 (carboxypolymethylene BF Goodrich, Cleveland, OH, USA) at pH 4.8, and then incubated for 7 days. Each tooth crown was sawn in half through the midline of buccal window along the long axis of premolar. The four blocks of premolars were immersed in a 10-times diluted solution of CPP-ACP paste (Tooth Mousse, GC Corp., Tokyo, Japan) for 1, 2, 3 and 5 weeks while the rests were immersed in a placebo solution (distilled water) for the same duration. Each specimen was embedded in epoxy resin, and was sectioned perpendicular to the window, using a water-cooled diamond blade saw. The spectrum density indices of Ca and P were measured in the sound, de- and remineralized enamels by FE-SEM and EDS. The Student's t test was performed to compare the Spectrum Density Indices (SDI) of sound, re-and demineralized enamels, and to compare the differences among the durations. Followings are the conclusion : 1. The penetration depth of the remineralizing ions (Ca & P) of CPP-ACP paste is related to the depth of demineralized enamel (approximately $1050{\sim}1350{\mu}m$). It is revealed that the penetration depth of both ions reaches full thickness of decalcification and even slightly into the sound enamel. 2. The Ca & P levels of remineralized enamels in 1, 2 weeks were significantly higher than those of the sound enamels (p<0.05). 3. No statistically significant difference of Ca & P levels was found in relation with the increasing duration of remineralization (p>0.05).

  • PDF

Cleanliness Test by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment (전자·반도체용 스프레이 분사형 세정제에 대한 청정도 평가)

  • Heo, Hyo Jung;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.688-694
    • /
    • 2009
  • A spray-type cleaning agent in utilizing dust-remover on PCB was chosen to study the cleanliness test and efficiency. In order to choose alternative environmental-friendly cleaning agents, it is important that the systematic selection procedures should be introduced and applied through the evaluation of their cleaning ability, environmental characteristics, and economical factors, and that the objective and effective evaluation methods of cleanliness should be established for the industry. A novel cleaning evaluation method with scanning electron microscopy/energy-dispersive X-ray analysis of surface observation evaluation method and an infra-red thermography camera(THERMOVISION A20 model) was studied in this work. The sound card(CT-2770 model) cut by $2{\times}2cm$ size was used as a part, and before and after the spray cleaning, the cleanliness was observed by the image analyzer of SEM and further the removal efficiency of dust was quantitatively evaluated by the component analysis of EDX. For the parts of P4TE model motherboard and IPC-A-36 PCB plate, before and after the spray cleaning, temperature differences were measured and compared at room temperature and 50 oven temperature by an infra-red thermography camera in the contaminants of dust and iron powder.

Prediction of the Acoustic Performance of a Music Hall Considering the Radiation Characteristics of Korean Traditional Musical Sources (국악음원의 방사특성을 고려한 국악원의 음향 성능 예측)

  • 정철호;이정권;연철호;한찬훈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.146-161
    • /
    • 2004
  • There have been always some difficulties in target setting and conditioning of acoustic performances of the Korean traditional music hall due mainly to the lack of the information on the sound radiation characteristics of Korean musical sources. In this study, the radiation characteristics of four typical Korean traditional musical sources were investigated in precision and their usage was demonstrated: The selected musical sources were Gayageum (string), Daegeum (woodwind), Jango (drum), and Pansori Chang (vocal performance). Each sound source was located at the center of a semi-anechoic chamber and the directivity was determined by the measured sound pressure levels in every 10° angular position, for both vertical and horizontal directions. The directivity pattern of Gayageum varies from a uniform to a complex pattern having many side lobes with the increase of frequency. The main radiation of Daegeum is toward the upward direction. The directivity pattern of Jango is clearly a side-oriented one and the left direction intensity is sharper than its right side at low frequencies. For the Chang, the directivity pattern change from a uniform pattern to a frontally directed one as the frequency goes high. Measured directional and spectral characteristics of traditional Korean music sources were implemented into the computation of architectural acoustic measures for the Busan National Korean Traditional Music Hall which is under construction. Parameters such as RT, SPL, C80, IE, STI were calculated at two receiver positions by using a ray tracing technique. Significant differences in the acoustic measures at receiver positions were observed between the results in using the omni-directional source and the directional one. It is thought that the suggested source data and design method can be used as a basic reference in the future acoustic design of performance halls for the Korean traditional music.