• 제목/요약/키워드: Sound Power

검색결과 811건 처리시간 0.025초

New method development for position estimation of underground acoustic source using a passive SONAR system

  • Jarng, Soon-Suck;Lee, Je-Hyeong;Ahn, Heung-Gu;Park, Heun-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1999년도 제14차 학술회의논문집
    • /
    • pp.149-152
    • /
    • 1999
  • The aim of the work described in this paper is to develop a complex underground acoustic system which detects and localizes the origin of an underground hammering sound using an array of hydrophones located about loom underground. Three different methods for the sound localization will be presented, a time-delay method, a power-attenuation method and a hybrid method. In the time-delay method, the cross correlation of the signals received from the way of sensors is used to calculate the time delays between those signals. In the power-attenuation method, the powers of the received signals provide a measure of the distances of the source from the sensors. In the hybrid method, both informations of time-delays and power-ratios are coupled together to produce better performance of position estimation. A new acoustic imaging technique has been developed for improving the hybrid method. For each method the sound localization is carried out in three dimensions underground. The minimum distance between the true and estimated origins of the source is 28 m for a search area of radius 250m.

  • PDF

New Acoustic Imaging Method Development for Localization of an Underground Acoustic Source Using a Passive SONAR System

  • Jarng, Soon-Suck
    • The Journal of the Acoustical Society of Korea
    • /
    • 제18권2E호
    • /
    • pp.10-17
    • /
    • 1999
  • The aim of the work described in this paper is to develop a complex underground acoustic system which detects and localizes the origin of an underground hammering sound using an array of hydrophones located about 100m underground. Three different methods for the sound localization will be presented, a time-delay method, a power-attenuation method and a hybrid method. In the time-delay method, the cross correlation of the signals received from the array of sensors is used to calculate the time delays between those signals. In the power-attenuation method, the powers of the received signals provide a measure of the distances of the source from the sensors. In the hybrid method, both informations of time-delays and power-ratios are coupled together to produce better performance of position estimation. A new acoustic imaging technique has been developed for improving the hybrid method. This new acoustic imaging method shows the multi-dimensional distribution of the normalized cost function, so as to indicate the trend of the minimizing direction toward the source location. For each method the sound localization is carried out in three dimensions underground. The distance between the true and estimated origins of the source is 28m for a search area of radius 250m.

  • PDF

서브밴드 필터 뱅크를 이용한 강인한 음원 추적시스템에 대한 연구 (A Study on the Robust Sound Localization System Using Subband Filter Bank)

  • 박규식;박재현;온승엽;오상헌
    • 한국음향학회지
    • /
    • 제20권1호
    • /
    • pp.36-42
    • /
    • 2001
  • 본 연구는 폐쇄된 사무 공간상에서 2개의 마이크로폰을 이용하여 임의의 위치에서 발생한 음성 및 음향의 방향성 (방향각)을 추적하는 새로운 알고리듬을 제안한다. 본 논문에서 제안한 Subband CPSP (Cross Power Spectrum Phase) 알고리듬은 기존의 CPSP 알고리듬을 개선한 것으로서, 마이크로폰에 수신된 2개의 입력 신호에 대해 서브밴드 필터 뱅크를 이 용하여 대역 분할하고 각 서브밴드 대역에서 구해지는 대역별 CPSP 결과의 평균값을 제공한다. 이러한 주파수 대역 분할방식은 잡음의 영향을 각 대역으로 한정 분산시켜 사무 공간내 잡음의 영향을 각 대역으로 한정하여 음원의 방향각 계산시 발생하는 오차를 최소화할 수 있는 보다 강인하고 정확한 음원 추적 시스템을 가능하게 한다. 제안된 알고리듬의 성능을 입증하기 위해 기존의 CPSP 와 Subband CPSP 알고리듬의 실시간 음원 추적 실험을 수행하였으며, 실험 결과 제안된 Subband CPSP가 CPSP에 비해 평균 5% 이상의 성능 향상을 가져옴을 확인할 수 있었다.

  • PDF

인간의 청각 시스템을 응용한 음원위치 추정에 관한 연구 (A study imitating human auditory system for tracking the position of sound source)

  • 배진만;조선호;박종국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.878-881
    • /
    • 2003
  • To acquire an appointed speaker's clear voice signal from inspect-camera, picture-conference or hands free microphone eliminating interference noises needs to be preceded speaker's position automatically. Presumption of sound source position's basic algorithm is about measuring TDOA(Time Difference Of Arrival) from reaching same signals between two microphones. This main project uses ADF(Adaptive Delay Filter) [4] and CPS(Cross Power Spectrum) [5] which are one of the most important analysis of TDOA. From these analysis this project proposes presumption of real time sound source position and improved model NI-ADF which makes possible to presume both directions of sound source position. NI-ADF noticed that if auditory sense of humankind reaches above to some specified level in specified frequency, it will accept sound through activated nerve. NI-ADF also proposes practicable algorithm, the presumption of real time sound source position including both directions, that when microphone loads to some specified system, it will use sounds level difference from external system related to sounds of diffraction phenomenon. In accordance with the project, when existing both direction adaptation filter's algorithm measures sound source, it increases more than twice number by measuring one way. Preserving this weak point, this project proposes improved algorithm to presume real time in both directions.

  • PDF

화력발전소의 소음분포 해석 및 방음벽 대책 (Noise distribution analysis and noise barrier measures of thermal power plant)

  • 윤준호;김원진
    • 한국음향학회지
    • /
    • 제39권2호
    • /
    • pp.105-112
    • /
    • 2020
  • 발전소 소음을 저감하기 위해서는 여러 가지 설비요소의 소음원에 대해 설계단계에서부터 정확한 소음예측을 수행하고, 과도한 소음에 대해서는 효과적이고 경제적인 방음대책의 수립이 필요하다. 이에 본 논문에서는 발전소 지역 및 주변 주택지역을 포함한 소음분포 해석 가능 모델을 제안하고, 주택지역의 소음저감 방법을 수립하였다. 발전소의 주요 소음원에 대한 소음레벨의 측정을 통하여 음향파워레벨을 평가하고, 설계도면 및 지형정보를 이용하여 소음전달에 영향을 주는 지형 및 지물 등을 최대한 상세히 모델에 포함함으로써 발전소 및 주택 지역의 소음분포를 효과적으로 해석할 수 있는 모델을 수립하였다. 수립된 소음 해석 모델의 신뢰성은 주요 위치에서의 소음레벨 해석 결과와 측정 결과를 비교하여 검증하였으며, 이를 바탕으로 신규호기의 증설에 의한 인근 주택지역에서의 소음 영향도를 평가하고, 발전소의 가동 시에 소음환경기준을 만족시키는 방음벽을 제안하였다.

Evaluation of Impact Sound Insulation Properties of Light-Framed Floor with Radiant Floor Heating System

  • Nam, Jin-Woo;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권3호
    • /
    • pp.75-84
    • /
    • 2002
  • In order to find out impact insulation properties, various types of current radiant floor heating systems and light-framed floors that are used in light-framed residential buildings were evaluated for two types of impact sources at the same time. Sound Pressure Level (SPL) was different from each impact sources for those spectrum patterns and peaks. In case of light-framed floor framework, the excitation position and the assumed effective vibrating area have effects on sound pressure level but it is not considerable, and Normalized SPL was reduced for each frequency by increasing the bending rigidity of joist. The mortar layer in the radiant heating system had relatively high density and high impedance, therefore, it distributed much of the impact power when it was excited, and reduced the Normalized SPL considerably. Nevertheless, Increasing a thickness of mortar layer had little influence on SPL. Ceiling components reduced the sound pressure level about 5~25 dB for each frequency. Namely, it had excellent sound insulation properties in a range from 200 to 4,000 Hz frequency for both heavy and lightweight impact sources. Also, there was a somewhat regular sound insulation pattern for each center frequency. The resilient channel reduced the SPL about 2~11 dB, irrelevant to impact source. Consequently, current radiant floor heating systems which were established in light-framed residential buildings have quite good impact sound insulation properties for both impact sources.

차량 윈도우 리프트 음질 고급감 향상을 위한 음질 지수 제작 및 개선에의 응용 (The Development and Application of Sound Quality Index for the Improving Luxury Sound Quality of Road Vehicle Power Window System)

  • 김성현;박동철;조현호;성원찬;강연준
    • 한국소음진동공학회논문집
    • /
    • 제24권2호
    • /
    • pp.108-116
    • /
    • 2014
  • With the increasing the importance of emotional quality of vehicle, the sound quality of systems with electric motor components has become increasingly important. Electric motors are used for windows, seats, sun roof, mirrors, steering columns, windshield wiper and climate control blowers, etc. In this paper, a study was conducted to identify sound quality factors that contribute to customer's satisfaction and preference of the window lift system. Jury test for subjective evaluation was carried out and sound quality index was developed. Averaged sound pressure level and sharpness were significant factors when glass moves down. Also, maximum loudness at stop section and averaged loudness were significant factor when glass moves up. Next, noise source identification was carried out using beam forming method during glass transferred section and impulsive noise at stop section. Several improvement methods were applied using the source identification result. And finally, the degree of sound quality improvement was judged using sound quality index.

브레이커 소음측정시스템을 활용한 소음의 측정 및 평가 (Measurement of Breaker Noise by Using Breaker Noise Measurement System)

  • 이재원;강대준;구진회;박형규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1173-1176
    • /
    • 2007
  • The breaker noise is one of the main noise sources of construction site. It is very important to assess and measure the breaker noise accurately, because the noise labelling will be in effect January 2008 in Korea. Therefore, It is necessary to measure the sound power level of breakers and use a appropriate test method in accordance with international standard. In this study, we measure the sound power level of breakers by using the breaker noise measurement system. This system makes it possible to measure the breaker noise more accurately than to measure the noise of that attached with excavator, because this system can control main factors affecting breaker noise such as hydraulic input power, hydraulic supply pressure, breaker inlet oil flow and so on.

  • PDF

스피커의 특성을 고려한 음향 전력 증폭기 구동 방식의 비교: 전압 구동 방식과 전류 구동 방식 (Comparison of the Driving Modes of an Audio Power Amplifier Considering the Characteristics of the Loudspeaker: Voltage Drive vs. Current Drive)

  • 은창수;이유칠
    • 한국멀티미디어학회논문지
    • /
    • 제20권9호
    • /
    • pp.1551-1558
    • /
    • 2017
  • Audio power amplifiers have been designed based on the premise that the impedance of loudspeakers is fixed at nominal 4 ohms or 8 ohms. However, it is known that the impedance varies with frequency and takes on the nominal value at some limited frequencies. The principle of the loudspeaker operation reveals that the sound pressure produced by the loudspeaker is proportional to the current flowing in the voice coil, not the voltage between the two terminals. We take the characteristics of the loudspeaker into account and compare the frequency responses of the loudspeaker in voltage-drive mode and current-drive mode via computer simulations, to conclude that the audio amplifier drive mode should be re-considered in an effort to improve the sound quality.

장간유리애자 파손시 절연파괴 특성 (The Electrical Breakdown Characteristics of Broken Toughened Glass Stem Insulator)

  • 정종욱;정진수;김영석
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1398-1406
    • /
    • 2008
  • This paper describes the electrical breakdown characteristics of broken toughened glass stem insulators by comparing with those of sound ones. The broken toughened glass stem insulators were taken from the electric railway field. According to the international standards, the sound and broken toughened glass stem insulators were tested in electrical strength. In the test, the power frequency voltage and the impulse voltage with a standard waveform were applied to the insulators. The power frequency voltage tests were carried out under both dry and wet condition and the impulse voltage tests under only dry condition. The acquired results were compared one another and discussed in electrical breakdown characteristic by analyzing the flashover progress pictures. As a result, the electrical strength of the broken toughened glass insulators was acquired and the processes of the surface breakdown on the toughened glass insulators were confirmed.