• 제목/요약/키워드: Sound Insulation Material

검색결과 95건 처리시간 0.027초

폴리에틸렌 튜브를 혼입한 경량 시멘트 경화체의 기초물성 평가 (An Evaluation on the Properties of the Hardened Lightweight Cement Using the Polyethylene Tube)

  • 김세영;전봉민;김효열;오상균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.57-60
    • /
    • 2006
  • This study proposes the physical properties of the hardened lightweight cement using the polyethylene tube and to make the fundamental data regarding a new lightweight concrete development. The aerated concrete is displaying various effects such as lightweight, insulation characteristic and it is coming to be widely applied the slab layer of apartment as an insulating material but currently the aerated concrete has many problems. Therefore, demonstrating similar property of former aerated concrete and improving the defects, developing new hardened cement is needed. In this study, we predict adopting possibility of hollow core polyethylene tube, as a material to make cement hardening containing a lot of void. So we changed the mixing ratio, a diameter and length of the polyethylene tube and improved the compressive strength and unit capacity weight of the lightweight cement hardening body. From the test results, we judge that the aerated concrete is a developmental possibility.

  • PDF

절연체의 내아크성 평가를 위한 안테나 기법의 적용에 관한 연구 (Study on the application of antenna method for the criterion test of insulator arc resistance)

  • 이강원;김명룡;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.57-60
    • /
    • 2004
  • Electrical arc is the final stage of insulation breakdown and has high current density which cause heat and light in insulator. Insulator under electrical arc lost its insulating strength and eternal damages. Conventional criterion of electrical arc resistance in Standards have depended on the change of sound pressure and light color after damages on insulator by electrical arc. The recognition of these changes is done by human himself which was very subjective and resulted in some error to judge whether insulator has damages or not. This paper has shown that antenna method is the appropriate measure to judge electrical arc resistance for insulator. Antenna measures the electromagnetic waves radiated from tungsten electrodes with 6mm gap regulated by KSC2130. Applied voltage cross two tungsten electrodes have two different methods such as 1/8 10 and continuous 10mA. Signal amplitudes obtained by antenna has diminished after the damage of insulator, which will provide objective and good way to judge the electrical arc resistance.

  • PDF

철도용 터널형 방음벽 개발연구: 설계 방향 (Noise Protection Roof: Partial Opening Effect for Noise Reduction)

  • 김태민;김정태
    • 한국철도학회논문집
    • /
    • 제18권6호
    • /
    • pp.522-532
    • /
    • 2015
  • 본 연구에서는 철도 교량 위를 주행하는 철도 소음에 의한 고층 공동주택 거주민들의 철도 소음 피해를 최소화할 뿐 아니라, 방음시설에 미치는 풍하중 및 자중을 동시에 감소시키는 방안으로 터널형 방음벽의 벽면부 개방을 검토하였다. 광음향기법, 전산 유체 역학 및 구조 역학을 이용하여 방음 효과, 유동 효과 및 구조 경량화가 고려된 터널형 방음벽 설계 및 효과를 예측하였다. 해석결과, 벽면부를 부분 개방하여 경량화 및 풍하중 감소 효과를 얻을 수 있었으며, 방음시설의 풍하중은 최대 30% 감소되었다. 부분 개방으로 인해 철도소음의 피해가 특정 높이에서 증가하기 때문에 이를 보완하기 위하여 개방된 부분에 소음기 형태의 음향 루우버 설치를 검토하였다. 음향 루우버의 경우 기존 방음재료의 차음성능과 유사한 성능이 존재하도록 개공율에 따른 유동 해석과 차음성능 해석을 수행하였다. 개공율 30~40% 개방 시, 차음성능 10dB를 만족하며 풍하중이 약 25% 저감되는 것으로 분석되었다. 결과적으로 터널형 방음벽의 벽면부 개방과 음향 루우버 설치는 경량화 및 풍하중에는 긍정적인 효과를 보여주며, 부분 개방과 함께 적절한 방음 재료와 방음설계가 동시에 적용될 경우, 거주민들이 요구하는 5-10dB 수준의 소음저감 효과가 나타나는 것으로 분석되었다.

Effect of the Holding Temperature and Vacuum Pressure for the Open Cell Mg Alloy Foams

  • Yue, Xue-Zheng;Hur, Bo-Young
    • 한국재료학회지
    • /
    • 제22권6호
    • /
    • pp.309-315
    • /
    • 2012
  • Metal foam has many excellent properties, such as light weight, incombustibility, good thermal insulation, sound absorption, energy absorption, and environmental friendliness. It has two types of macrostructure, a closed-cell foam with sealed pores and an open-cell foam with open pores. The open-cell foam has a complex macrostructure consisting of an interconnected network. It can be exploited as a degradable biomaterial and a heat exchanger material. In this paper, open cell Mg alloy foams have been produced by infiltrating molten Mg alloy into porous pre-forms, where granules facilitate porous material. The granules have suitable strength and excellent thermal stability. They are also inexpensive and easily move out from open-cell foamed Mg-Al alloy materials. When the melt casting process used an inert gas, the molten magnesium igniting is resolved easily. The effects of the preheating temperature of the filler particle mould, negative pressure, and granule size on the fluidity of the open cell Mg alloy foam were investigated. With the increased infiltration pressure, preheat temperature and granule sizes during casting process, the molten AZ31 alloy was high fluidity. The optimum casting temperature, preheating temperature of the filler particle mould, and negative pressure were $750^{\circ}C$, $400-500^{\circ}C$, and 5000-6000 Pa, respectively, At these conditions the AZ31 alloy had good fluidity and castability with the longest infiltration length, fewer defects, and a uniform pore structure.

완충재의 동특성에 따른 중량충격음 증폭에 관한 해석적 연구 (The effect of dynamic property of absorbing sheet on the amplification of heavy weight floor impact noise)

  • 황재승;문대호;박홍근;홍성걸;홍건호;임주혁;김용남
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.527-528
    • /
    • 2010
  • Previous experimental results performed by many researchers for a couple of decades in South Korea have shown that an absorbing sheet inserted in a conventional floating slab system for thermal insulation or vibration absorption may amplify the vibration of the slab system at specific frequency ranges depending on the material properties of the sheet. The amplified vibration, consequently, results in the heavy weight floor impact noise exceeding the sound level limit for an apartment house, 50dB. In this study, the amplification mechanism is examined through numerical analysis and a new slab system is proposed to reduce the amplification and control the noise. The new slab system consists of studs connecting the base slab and upper concrete finishing yielding the dramatically increased stiffness of the slab. The numerical simulation is performed to investigate the effect of the slab system with studs on the vibration and noise control. The results show that the performance of the slab is sensitive to the number and location of studs, and the heavy weight floor impact noise can be reduced up to 6-7dB compared to the conventional slab system at the optimal stud location.

  • PDF

알루미늄 복합 외장재를 사용한 고층 건축물의 외기 풍속, 풍향 변화가 화염전파에 미치는 영향에 대한 수치해석 연구 (NUMERICAL STUDY ON THE EFFECT OF EXTERNAL AIR VELOCITY AND DIRECTION ON FLAME SPREAD IN HIGH RISE BUILDING WITH THE ALUMINUM COMPOSITE EXTERNAL MATERIALS)

  • 김호진;배승용;최영기;유홍선
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.225-229
    • /
    • 2011
  • The aluminum composite panel are widely used for the external materials of high rise building because of well insulation of heat and sound and improved Constructability. However, the polyethylene in main material of the aluminum composite panel shows weakness in thermal and fire resistances. For this reason, flame is spread more quickly when the fire break out. Therefore, the potentiality of fire spread to the exterior wall is high due to difficulty of early extinguishment and effect of external air. In this study, numerical investigation was performed by using FDS program for flame spread characteristics with various external air velocity and direction in ten-story building with the aluminum composite external materials. As a result, the flame spread velocity is 0.134m/s and it takes 224 seconds for flames to spread to the 10th floor without external air velocity. however, the flame spread velocity decreases 40% and it takes 348 seconds for flames to spread to the 10th floor when external air velocity is 2.5 m/s. and air direction is little effect compared to air velocity.

  • PDF

발전기 고정자 권선에 사용되는 마이카/에폭시 복합재료의 기계적 특성에 관한 연구 (Mechanical Properties of Mica/Epoxy Composite Materials used in Genrator Stator Windings)

  • 김희동;김희곤;김태완;강도열
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권4호
    • /
    • pp.327-333
    • /
    • 1997
  • Experiments on mechanical fatigue were conducted using the specimens which were cut from hydrogen cooled generator(rated 22kV and 50OMW) stator windings. We have investigated the aged mechanism of mica/epoxy insulation systems under air or hydrogen by both the tensile and compressive loadings. The fracture of generator stator windings is generally affected by mechanical stress. Thus, the tensile strength test were conducted. In this case, the maximum strength and strain are quite different between sound and aged specimens. It is observed that low bonded interface parts of tapes generally have lower strength than those of normal tapes which causes stress. In order to estimate the effects of cyclic load by the electromagnetic forces while the generator starts/stops, the mechanical fatigue test was also conducted. It is confirmed that the equation of expected life depends on stress amplitude and number of cycles. Though the stress amplitude and number of cycles are very tiny, the tensile fatigue of aged specimens under hydrogen atmosphere is bigger than those under air. In the case of hydrogen atmosphere, the tensile stress gives bigger effect than the compressive one.

  • PDF

인공경량골재로 제조된 콘크리트 패널의 물성 (Properties of Concrete Panel Made by Light Weight Aggregates)

  • 엄태호;김유택
    • 한국세라믹학회지
    • /
    • 제41권3호
    • /
    • pp.221-228
    • /
    • 2004
  • 국내에서는 최근 구조물 증축에 필요한 경량골재를 중국 및 일본 등에서 수입해 사용하고 있는 실정이고, 환경오염에 대한 관심 또한 고조되면서 폐기물의 처리, 처분 문제가 심각하게 대두되고 있다. 이에 순수 국내 기술로 폐기물과 점토질 원료를 습식혼합, 로터리 킬른에서 소성하여 인공경량골재를 제조한 후 기본 물성을 평가하였고 경량콘크리트에 적용하여 강도특성을 고찰하였다. 인공경량골재의 절건비중은 1.4~1.7, 흡수율은 13~16%이었으며, 파쇄율은 약 30~55%로 강자갈이나 쇄석과 비교하여 10% 이상 높은 수치를 나타내었고 파쇄 형상에서도 차이를 보였다. 골재를 2mm 이하로 분쇄하여 TCLP 용출시험 후 추출된 여액을 ICP-AES로 분석한 결과, 검출한계 이하 또는 용출량 기준치 이하로 용출되었다. 제조된 인공경량골재를 사용한 경량콘크리트 공시체를 제작하여 슬럼프, 압축강도, 휨파괴변형 특성을 시험하였다. 시험 결과, 인공골재 치환율 30vo1%, 물시멘트비 45wt%인 공시체에서의 슬럼프 및 압축강도 특성이 가장 우수하였다. 경량골재 콘크리트의 슬럼프 및 압축강도 시험결과를 통해 도출된 최적배합을 바탕으로 경량콘크리트 패널을 제작하여 단열 및 차음특성을 시험한 결과, 평균 열관류율은 3.293W/$m^2$$^{\circ}C$로 쇄석콘크리트에 비해 약 15% 우수하였으며, 음향투과손실은 500Hz에서 50.9㏈로 기준치를 약 13% 상회하는 결과를 보였다.

풍하중 저감형 방음판의 실증 연구 (An Empirical Study of Soundproof wall with Reduced Wind Load)

  • 최진규;이찬영
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.272-278
    • /
    • 2018
  • 최근 도시개발과 생활수준의 향상으로 인해 교통량이 크게 증가하고 있으며, 이와 더불어 증가되는 도로 소음으로 인해 많은 민원이 제기되고 있다. 이에 대한 대책으로 도로변에 높은 방음벽이 설치되고 있으나 방음벽 주요 설계 요건인 풍하중은 공사비의 기하급수적인 증가뿐만 아니라 방음벽 높이 제한의 요인으로 작용하게 된다. 이에 본 연구에서는 기존 방음벽 수준의 차음 성능과 더불어 풍하중을 획기적으로 저감할 수 있는 우수한 가격 경쟁력의 방음벽을 개발 하는 것을 목적으로 한다. 본 연구 대상의 방음판은 헬름홀츠의 공명기 이론을 바탕으로 공기와 같은 유체는 통과하고 소음은 저감할 수 있는 신개념 통기형 방음판에 해당된다. 본 연구에서는 실 크기의 금속재 방음판을 제작하여 음압투과손실실험, 풍동실험 및 재료품질 실험을 수행하여 고속도로의 품질기준을 만족하는 결과를 도출하였다. 또한 신뢰성을 검증하기 위해 현장에 제작 및 설치를 하고 시간대 별로 소음을 측정하여 방음판의 소음 차단 효과를 확인하였다. 향후 도로에 통풍형 방음벽을 설치할 경우 높은 소음 차단 효과로 인하여 쾌적한 생활환경을 조성할 수 있을 것으로 예상된다.

어린이집 실내·외 석면노출 가능성 조사에 관한 연구 (A Survey on Asbestos Exposure Possibility in Indoor and Outdoor Environments of Childcare Centers)

  • 박화미;손병훈
    • 한국산업보건학회지
    • /
    • 제24권2호
    • /
    • pp.122-129
    • /
    • 2014
  • Objectives: Because of its properties such as resistance to heat, chemicals and corrosion; tensile strength; sound absorption; and affordable price, asbestos has been widely used as a building material, fire resistant and retardant, thermal and heat insulator, soundproofing material, and electrical insulation. Since the prolonged inhalation of asbestos can cause serious illnesses such as lung cancer, mesothelioma, and asbestosis after an incubation period of 20 to 40 years, the mineral was classified as a Group 1 carcinogen by the International Agency for Research on Cancer, an intergovernmental agency forming part of the World Health Organization. Children and infants are more at risk than are adults if they are exposed to carcinogens, due to aweaker immunity that has not yet been fully developed. Most childcare centers are operated all day and children tend to spend a great amount of time in the centers. This is why it is important for them to be systematically isolated from environments that may expose them to asbestos. Materials: In order to understand both indoor and outdoor hazards to which children may have been exposed, the study focused on actual surveys of asbestos used in childcare centers, paying special attention to slate-roofed buildings in the vicinity of the centers. Results: A survey of a total of 211 childcare centers showed that the buildings of 18.1% of the centers contained asbestos, with 60.53% of the material being found in classroom ceilings. "Tex" was the most used material for ceilings, making up 89.47% of all ceilings. An outdoor survey showed that childcare centers in Daegu Metropolitan City had an average of 143 slate-roof buildings within a distance of 1km. Conclusions: Buildings housing mainly toddlers, children, teenagers and others more vulnerable to the toxicity of asbestos are not subject to asbestos investigation by law. A legal and practical basis for asbestos control is required for such buildings. In particular, housing materials which contain asbestos in day care centers require asbestos control. GIS should be used to identify the location of buildings with slate roofing materials in the vicinity of daycare centers in order to gauge toxicity of exposure to asbestos caused by potential asbestos friability possibility in outdoor conditions.