• 제목/요약/키워드: Sorbent tube

검색결과 25건 처리시간 0.025초

A Low-Cost Open-Source Air Sampler for the Sorbent Tube Sampling for TD-GC/MS Analysis

  • Jang, Hwa-yong;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • 제11권4호
    • /
    • pp.95-102
    • /
    • 2020
  • In this study, we provide full descriptions of how to make a low-cost and completely open-source laboratory-made air sampler that will be used for sample adsorption for thermal desorption-gas chromatography mass spectrometry (TD-GC/MS) analysis. It is well known that harmful gases cause bad effects on human bodies, so it is necessary to identify the types and amounts of gases in industrial sites. One of the most commonly used methods for gas sampling is to utilize a sorbent tube using an air sampler. Commercially available air samplers are expensive, typically priced between $1,000 and $2,000, and their design often cannot be modified to fit the experiment. To address these shortcomings, we have developed a do-it-yourself (DIY) air sampler that is not only cheap enough, but also completely open-source. Furthermore, the performance of the fabricated air sampler was validated in conjunction with TD-GC/MS for the analysis of volatile compounds.

열탈착/저온농축-GC/MS에 의한 실내공기 중 휘발성 유기화합물 정량용 기체상 및 액체상 표준물질 첨가한 고체 흡착관의 비교 분석 (A comparative analysis of gas and liquid phase standard spiked solid sorbent tubes for the determination of volatile organic compounds in indoor air by TD-GC/MS)

  • 임현우;정성운;강철호;박진숙;박병무;최용욱
    • 분석과학
    • /
    • 제26권4호
    • /
    • pp.287-297
    • /
    • 2013
  • 본 연구는 고체 흡착관과 TD-GC/MS를 이용하여 7종의 휘발성 유기화합물에 대한 열탈착 분석조건을 최적화하였고, 기체상 및 액상 표준물질 첨가한 고체 흡착관을 사용하여 얻어진 검정곡선으로부터 휘발성 유기화합물을 비교 정량하였다. 대응표본 t-검정 결과, 스타일렌을 제외하고 벤젠, 톨루엔, 에틸벤젠, o-, m- 및 p-자일렌을 포함한 6종의 휘발성 유기화합물에 대해서는 액상 표준물질에 의한 표준 흡착관법이 기체상에 의해 제작된 표준 흡착관법이 유의수준 (${\alpha}=0.01$)에서 일치한 반면, 스타일렌에 대해서는 기체상 및 액체상으로 작성된 검정곡선에서 감응인자가 15.6% 차이가 발생하였는데 이것은 두방법 간에 유의한 차이가 있다는 것을 의미하였다. 따라서 BTEX를 포함한 스타일렌을 정량하는데 오차를 감소시키기 위해 액상 표준물질을 이용한 고체상 흡착관법을 사용하였다. 바로 그 점이 이 논문의 핵심내용임. 즉, 고가의 표준가스 대신에 저가의 액상 표준물질을 사용하여 정량하더라도 스타일렌 이외에 거의 동일한 값을 나타내기 때문임. 액체상 표준물법 조건에서 7종의 VOCs의 회수율은 $100{\pm}5%$, 재현성은 0.3~7.7%, 검출한계는 o-자일렌의 $0.01{\mu}g/m^3$에서부터 톨루엔의 $0.27{\mu}g/m^3$까지 범위를 나타내었다. 이러한 최적화된 분석방법을 신축 기숙사, 원룸 아파트 및 신차의 실내공기 중 휘발성 유기화합물을 정량하는데 적용하였다.

에어샤워부품의 용출 가스 중 유기화합물의 반 정량적 Headspace GC-MS 분석 (Semiquantitative Dynamic Headspace GC-MS Analysis for Organic Compounds Outgassed from FAB Materials of Air Shower)

  • 박현미;백승우;김영만;이강봉
    • 분석과학
    • /
    • 제13권4호
    • /
    • pp.412-422
    • /
    • 2000
  • 실리콘 웨퍼 산업계의 청정실에서 사용되는 에어샤워기중 고분자로 제작된 부품들을 $100^{\circ}C$에서 30분간 다이나믹 해드 스페이스에서 가스로 용출한 후 GC-MS로 분석 하였다. 에어샤워기가 가동중인 청정실의 대기를 흡착관 튜브방식으로 채취하였고, 이러한 흡착관 튜브에 흡착된 유기화합물은 쏙시렛 용출법을 이용하여 용출한 후 GC-MS로 분석하였다. 에어샤워기의 제조 부품(electric over current relay, acryl plate. polycarbonate window, filter, fan housing, steel galvanized cold plate and canvas buffer)들로 부터의 분석결과 대부분의 성분들은 제조부품의 고분자 성분들에서 유래되었음을 확인 할 수 있었으며, 에어샤워기가 가동중인 청정실의 대기분석 결과와 비교 분석되었다. 이러한 분석결과의 비교 연구는 청정실내에서의 유기오염물질이 에어샤워기의 고분자 제조부품으로부터 유래 되었는지를 확인하게 해준다.

  • PDF

2,4-DNPH와 가스크로마토그래프를 이용한 포름알데히드 분석방법 (Analytical method for analyzing formaldehyde using 2, 4-DNPH and gas chromatography/FID, NPD)

  • 정지연;박승현;이광용;오세민
    • 한국산업보건학회지
    • /
    • 제10권1호
    • /
    • pp.126-146
    • /
    • 2000
  • To develop and evaluate formaldehyde measurement method using 2,4-dinitro-phenylhydrazine (2,4-DNPH) coated sampler and gas chromatography, laboratory test and field test were conducted. Results of this study are as follows. Limit of detection(LOD) of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is $0.008{\mu}g/m{\ell}$ $0.060{\mu}g/m{\ell}$, $0.472{\mu}g/m{\ell}$ respectively. Coefficiency of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is 0.008, 0.009, 0.020 respectively. Desorption efficiency of sep-pak xposure aldehyde sampler and sorbent sample tube is 1.05(range : 0.99 - 1.12), 1.02(range : 0.99 - 1.06) respectively. Samples of sorbent sample tube and sep-pak xposure aldehyde sampler turned out to be stored at refrigerator, according to storage test results. Measurement methods of HPLC-UVD, GC-NPD, GC-FID, according to results of precision for the combined sampling and analytical procedure, became acceptable to OSHA evaluation standard. Field test using exposure chamber met the NIOSH overall uncertainty recommendation(less than 25%). Overall uncertainty of Sepak-HPLC(UVD), Tube-GC(NPD), Tube-GC(FID) is 11.0% - 17.0%. Consequently gas chromatography(GC-NPD, GC-FID) and high performance liquid chromatography(EPA TO-11) using 2,4-DNPH coated sampler for formaldehyde measurement turned out to be suitable to measure personal formaldehyde exposure at workplaces.

  • PDF

Identification of Coffee Fragrances Using Needle Trap Device-Gas Chromatograph/Mass Spectrometry (NTD-GC/MS)

  • Eom, In-Yong;Jung, Min-Ji
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1703-1707
    • /
    • 2013
  • A fast and simple sampling and sample preparation device, (NTD) has been developed and applied to sample and analyze volatile components from ground coffee beans. Coffee fragrances and other volatile organic compounds (VOCs) were sampled by the NTD and then analyzed by gas chromatograph-mass spectrometry (GC/MS). Divinylbenzene (DVB) particles (80/100 mesh size) were the sorbent bed of the NTD. More than 150 volatile components were first identified based on the database of the mass library and then finally 30 fragrances including caffeine were further confirmed by comparing experimental retention indices (i.e. Kovat index) with literature retention indices. Total sampling time was 10 minutes and no extra solvent extraction and/or reconstitution step need. Straight n-alkanes (C6-C20) were used as retention index probes for the calculation of experimental retention indices. In addition, this report suggests that an empty needle can be an alternative platform for analyzing polymers by pyrolysis-GC/MS.

공기연소 분위기와 순산소 연소 분위기에서 입자 크기와 습도가 $CaCO_3$ 흡착제 입자의 반응특성에 미치는 영향 분석 (Analysis of the Effect of Particle Size and Humidity on Reaction Characteristics of $CaCO_3$ Sorbent Particle under Air and $O_2/CO_2$ Atmospheric Conditions)

  • 정성하;이강수;길상인;윤진한;김상수
    • 한국입자에어로졸학회지
    • /
    • 제10권2호
    • /
    • pp.75-82
    • /
    • 2014
  • It is necessary to find out the reaction characteristics of $CaCO_3$ sorbent particles in air and $O_2/CO_2$ atmospheric conditions in order that an in-furnace desulfurization technique can be applied to oxy-fuel combustion system. In this study, rate of change of GMD(geometric mean diameter) and specific surface area of $CaCO_3$ sorbent particles reacted in DTF(drop tube furnace) experimental setup were analyzed to investigate the effect of particle size and humidity on the reaction characteristics of them. In air atmospheric condition, calcination process occurs actively within shorter residence times as the particle size increases. On the contrary, in $O_2/CO_2$ atmospheric condition, a calcination process is delayed as particle size increases. The increment of humidity accelerates calcination process in an air atmospheric condition and increase rate of calcination in an $O_2/CO_2$ atmospheric condition.

흡착튜브 - 열탈착 정량분석 기법에 기반한 과일시료로부터 자연적 휘발성유기화합물의 배출특성 연구 (Biogenic Volatile Organic Compounds (BVOC) Emissions from Fruit Samples Based on Sorbent Tube Sampling and Thermal Desorption (ST-TD) Analysis)

  • 안정현;김기현
    • 한국대기환경학회지
    • /
    • 제29권6호
    • /
    • pp.757-772
    • /
    • 2013
  • In this study, a combination of sorbent tube (ST)-thermal desorption (TD)-gas chromatography (GC)-mass spectrometry (MS) was used for quantitative analysis of liquid phase standards of 10 BVOC ((1) (+)-${\alpha}$-pinene, (2) (+)-${\beta}$-pinene, (3) ${\alpha}$-phellandrene, (4) (+)-3-carene, (5) ${\alpha}$-terpinene, (6) p-cymene, (7) (R)-(+)-limonene, (8) ${\gamma}$- terpinene, (9) myrcene, and (10) camphene). The results of BVOC calibration yielded comparatively stable pattern with response factor (RF) of 23,560~50,363 and coefficient of determination ($R^2$) of 0.9911~0.9973. The method detection limit (MDL) of BVOC was estimated at 0.03~0.06 ng with the reproducibility of 1.30~5.13% (in terms of relative standard error (RSE)). Emissions of BVOC were measured from four types of fruit samples ((1) tangerine (TO), (2) tangerine peel (TX), (3) strawberry (SO), and (4) sepals of strawberry (SX)). The sum of BVOC flux (${\sum}flux$ (BVOC) in ng/hr/g) for each sample was seen on the descending order of (1) TX=291,614, (2) TO=2,190, (3) SO=1,414, and (4) SX=2,093. If the results are compared between the individual components, the highest flux was seen from (R)-(+)-limonene (265,395 ng/hr/g) from TX sample.

기중 포름알데히드 측정을 위한 확산포집기의 개발 (The Development of New Diffusive Sampler for Formaldehye in Air)

  • 최미헌;이광묵;노영만
    • 한국산업보건학회지
    • /
    • 제9권1호
    • /
    • pp.173-186
    • /
    • 1999
  • To utilize diffuse sampling of formaldehyde in air, a new sampler was designed. A glass fiber filter was impegnated with 2,4-dinitrophenylhydrazine(DNP) and phosphoric acid and mounted 37mm cassette. The formaldehyde vapor was sampled in the dynamic chamber and measured by high performance liquid chromatograph and compared with solid sorbent tube. The results were as follows ; 1. The desorption efficiencies of diffusive sampler between 97.0% and 100%. 2. the sampling rate is constant as in $58{\sim}61.8m{\ell}/min$ when sampling times are between 120 and 360 min. 3. There was a significant relationship between concentrations of diffusive samples and active samples with the coefficient of determination(R2) of 0.92. 4. Desorbed amount of formaldehyde diffusive sampler was increased by high relative humidity. 5. Wheth diffusive samplers were stored at room temperature or at refrigerator there was no statistically significant difference in the accuracy of result. 6. When the diffusive samplers, which collected formaldehyde vapor, were exposed to clean air for three hours, there was no significant loss of formaldehyde due to reverse diffusion. In conclusion, this study suggest that developed diffusive samplers will be a reasonable substitute for the solid sorbent tube for sampling formaldehyde and practical comparative study of developed diffusive sampler should be performed at workplaces of manufacturing industry.

  • PDF

ACF 흡착관 개발을 위한 파괴특성에 관한 연구 (A study on breakthrough characteristics of activated carbon fiber by development of sorbent tube)

  • 원정일;김기환
    • 환경위생공학
    • /
    • 제20권1호
    • /
    • pp.40-54
    • /
    • 2005
  • This dissertation aims to develop adsorption tubes for measuring organic solvents in the working environment, by comparing and analyzing breakthrough condition and adsorption capacity with ACF. 1. In breakthrough characteristics, the raising velocity of breakthrough curve is increasing according to assault concentration, but $50\%$ breakthrough time is decreasing. As breakthrough curve of calculated data using this agrees with the one of experimental data both of them can be used on determining sampling time of adsorption tubes. It is predicted by theoretical that $10\%$ breakthrough time is increasing in the case of increasing filled adsorbent amount. 2. $10\%$ breakthrough time is regularly decreasing as much as assault concentration is increasing. As a result, we can predict the life of adsorbent within the range of the low concentration, and adsorption amount that ACF can sample during $10\%$ breakthrough time is increasing as much as assault concentration is increasing.