• 제목/요약/키워드: Soot characteristics

검색결과 307건 처리시간 0.027초

LPG 확산화염내 매연입자의 전기적 특성 및 전기장에 의한 입자 크기 변화 (Electrical characteristics of soot particles in a LPG diffusion flame and particle size change by electric fields)

  • 박종인;지준호;황정호
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1326-1338
    • /
    • 1997
  • Electrical characteristics of soot particles in a LPG diffusion flame were studied for the control of soot particle coagulation. When a DC voltage was applied between two electrodes installed parallel to gas flow, ionic wind effect caused soot deposition on the cathode, implying that most of the soot particles were positively charged. Soot deposit on the cathode linearly increased and was saturated with respect to the strength of the applied voltage. The possibility of applying an AC voltage to enhance the particle coagulation was then investigated and the efficiency of the size control was checked with transmission electron microscope photographs. For the amplitude of 2 kV AC field, primary (spherical) soot particle size decreased from 30 ~ 40 nm to around 20 nm when the frequency of the applied AC voltage was 60 Hz and higher. Collisions between the soot particles in such a selected AC condition could lead to the formation of much bigger agglomerates of roughly 1-5 .mu.m in size.

촉매 코팅 DPF의 soot loading과 유량 변화에 따른 압력강하 및 열전달에 관한 실험적 연구 (An Experimental Study on Effects of Soot Loading and Mass Flow Rate on Pressure Drop and Heat Transfer in Catalyzed Diesel Particulate Filter)

  • 조용석;노영창;박영준;김득상
    • 한국자동차공학회논문집
    • /
    • 제15권3호
    • /
    • pp.72-78
    • /
    • 2007
  • A diesel particulate filter causes progressive increase in back pressure of an exhaust system due to the loading of soot particles. To maintain the pressure drop caused by DPF under proper level, a regeneration process is mandatory when excessive loading of soot is detected in the filter. It is a major reason why the relation between the amount of soot and the pressure drop in a DPF becomes crucial. On the other hand, pressure drop varies with not only the soot loading but also conditions of exhaust gas such as mass flow rate. Therefore, the relation among them becomes complicated. Furthermore, the characteristics of heat transfer in a DPF is another crucial parameter in order for the filter to avoid thermal crack during regeneration period. This study presents characteristics of pressure drop under various conditions of soot loading and mass flow rate in catalyzed diesel particulate filter. This study also shows characteristics of heat transfer in DPF when high temperature gas flows into the filter. Experiments reveal that the soot loading and mass flow rate affect characteristics pressure drop independently. Experiments also indicate that the amount of coating material has little influence on pressure drop with changes in soot loading and mass flow rate. However, increased catalyst coating may lead to the improved heat transfer which is efficiency to reduce thermal stress of the filter.

동축류 확산화염의 OH 라다칼 분포 및 매연 특성 (OH Radical Distribution and Sooting Characteristics in Co-Flow Diffusion Flames)

  • 이원남;송영훈;차민석
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1997년도 제15회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.1-11
    • /
    • 1997
  • The soot and OH radical distributions have been experimentally studied in ethylene and propane laminar diffusion flames. The integrated soot volume fraction was measured along the centerline of a flame using a laser light extinction method. Planar laser light scattering and PLIF techniques are employed for the soot and OH radical distribution measurements utilizing Nd:YAG laser and OPO, FDO system. The concentration of OH radical is rapidly decreased at the edge of sooting region, which implies the importance of OH radical species on the soot oxidation process. For ethylene flames, the addition of air in fuel moves the OH radical distribution towards the center line of a flame at the soot oxidation region, while the concentration of OH radical remains relatively high at the soot formation region. The interaction between soot particles and OH radicals becomes more active with fuel-air at the soot oxidation region. For propane flames, however, any indication of the increased interaction between soot particles and OH radicals with fuel-air was not noticed.

  • PDF

아세틸렌/공기 비예혼합 난류 제트화염의 Soot 생성에 대한 수치해석 (Numerical Analysis for the Soot Formation Processes in Acetylene-Air Nonpremixed Turbulent Jet Flame)

  • 김후중;김용모;윤명원
    • 한국자동차공학회논문집
    • /
    • 제10권6호
    • /
    • pp.80-89
    • /
    • 2002
  • The flame structure and soot formation in Acetylene-Air nonpremixed jet flame are numerically analyzed. We employed two variable approach to investigate the soot formation and oxidation processes. The present soot reaction mechanism involves nucleation, surface growth, particle coagulation, and oxidation steps. The gas phase chemistry and the soot nucleation, surface growth reactions are coupled by assuming that the nucleation and soot mass growth has the certain relationship with the concentration of pyrene and acetylene. We also employed laminar flamelet model to calculate the thermo-chemical properties and the proper soot source terms from the information of detailed chemical kinetic model. The numerical and physical model used in this study successfully predict the essential features of the combustion processes and soot formation characteristics in the reaction flow field.

선박용 디젤 엔진 수트의 발생원에 따른 구조적 특성 연구 (Structural Characteristics of Marine Diesel Engine Soot by Source)

  • 강준;최재혁;윤성환;김수양;김준수;장하식;이원주
    • 해양환경안전학회지
    • /
    • 제26권1호
    • /
    • pp.114-120
    • /
    • 2020
  • 본 연구에서는 IMO의 향후 예상 규제 물질 중 하나인 수트를 선박용 엔진을 대상으로는 최초로 배기 수트와 엔진 수트로 구분하여 구조적 특성의 비교 분석을 시도하였다. 그리고 최근 발표되고 있는 배기 수트 재활용 연구의 연장선상에서 엔진 수트의 재활용 가능성 여부를 확인하기 위하여 2,000℃로 열처리를 시행하였고, 열처리 전·후의 수트를 고분해능 전자현미경과 라만분광법을 통해 분석하였다. 전자 현미경을 통한 분석 결과, 배기 수트와 엔진 수트는 유사한 형태의 나노 구조를 가지고 있으나, 배기 수트는 구형의 1차 입자가 체인형 결합구조를 가지고 있었고, 엔진 수트는 배기 수트에 비해 무정형한 구조가 확인되었다. 라만분광법 분석 결과, 배기 수트와 엔진 수트 모두 D peak(1,350 cm-1)와 G peak(1,580 ~ 1,600 cm-1)가 확인되었다. 다만, G/D ratio는 엔진 수트에 비해 배기 수트가 상대적으로 높게 나타나며, 이는 배기 수트가 더 흑연화 된 구조를 나타냄을 의미한다. 열처리 후의 분석 결과, 엔진 수트도 배기 수트와 유사하게 흑연화가 문제없이 진행됨을 확인하였고, 이를 통해 선박용 디젤엔진에서 발생하는 배기 수트와 엔진 수트 모두 흑연재료로 재활용이 가능함을 확인하였다.

엔진 오일 열화와 피스톤 톱링 그루브 온도가 카본 디포짓 형성에 미치는 영향 Part II-디젤 엔진의 디포짓 형성 특성 (The Effect of Engine Oil Degradation and Piston Top Ring Groove Temperature on Carbon Deposit Formation Part II - The Deposit Formation Characteristics of Diesel Engine)

  • 김중수;민병순;오대윤;최재권
    • Tribology and Lubricants
    • /
    • 제14권4호
    • /
    • pp.108-113
    • /
    • 1998
  • In order to investigate the characteristics of top ring groove deposit formation in diesel engine, engine test and simulation test were performed. From component analysis of used oils sampled from actual running engines, soot content in engine oil was selected as a main parameter for evaluating oil degradation. Deposit formation is highly related to soot content in lubricating oils. And high soot content oil accelerates deposit formation even in low temperature region below 26$0^{\circ}C$. In low temperature region below 26$0^{\circ}C$, deposit formation rate is mainly affected by top ring groove temperature. However, in high temperature region above 26$0^{\circ}C$, deposit formation rate is affected by soot content as well as top ring groove temperature. Therefore, soot content as well as top ring groove temperature should be kept a certain level in order to prevent troubles due to carbon deposit formation.

역 확산화염 내 매연입자에 의한 광소멸 특성 연구 (Light Extinction Characteristics of Soot Particle in Hydrocarbon Inverse Diffusion Flames.)

  • 임상철;이승훈;안태국;남연우;박선호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.257-260
    • /
    • 2015
  • Light extinction characteristics of soot particles in ethylene and propane inverse diffusion flames have been experimentally investigated. The measured data suggested that the refractive index of soot particles varies with light wavelength due to PAH contents existing during the soot growth process. The results showed that the scattering effect is less important as the size of secondary particles rarely affects the optical properties of the soot even when the size is large enough to deviate from Rayleigh assumptions.

  • PDF

레이저 및 열전대를 이용한 동축류 확산화염에서의 매연입자 측정에 관한 연구 (A Study on the Soot Particle Measurement in Co-Flow Diffusion Flame Using a Laser Diagnostics and a Thermocouple)

  • 한용택;이기형;이원남
    • 대한기계학회논문집B
    • /
    • 제28권7호
    • /
    • pp.863-870
    • /
    • 2004
  • The temperature and soot particle measurement technique in a laminar diffusion flame has been studied to investigate the characteristics of soot particle with temperature using a co-flow burner. The temperature distribution in the flame were measured by rapid insertion of a R-type thermocouple and the soot particles by LEM/LIS techniques. In these measurement, soot volume fraction, number density and soot diameters were analyzed experimentally. As a results, the spacial distributions of particle volume fraction, soot diameter, and number density are mapped throughout the flame using the Rayleigh theory for the scattering of light by particles. A laser extinction method was used to measure the soot volume fraction and laser induced scattering method was used to measure the soot particle diameter and number density. Also, we measured temperature without the effect of soot particles attached to the thermocouple junction, which is close to the nozzle. In this result, we found that upstream zone has a unstable flowing in co-flow diffusion flame and the y-axis temperature of flame has a uniform temperature distribution in the most soot volume fraction zone.

레이저 및 열전대를 이용한 동축류 확산화염에서의 매연입자 측정에 관한 연구 (A Study on the Soot Particle Measurement in Co-flow Diffusion Flame Using a Laser Diagnostics and a Thermocouple)

  • 한용택;이기형;이원남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1267-1273
    • /
    • 2004
  • The temperature and soot particle measurement technique in a laminar diffusion flame have been studied to investigate the characteristics of soot particle with temperature using a co-flow burner. The temperature distributions in the flame were measured by rapid insertion of a R-type thermocouple and the soot particles were detected were detected by LEM/LIS techniques. In these measurement, soot volume fraction, number density and soot diameters were analyzed experimentally. As a results, the spacial distributions of particle volume fraction, soot diameter, and number density are mapped throughout the flame using the Rayleigh theory for the scattering of light by absorbing particles. A laser extinction method was used to measure the soot volume fraction and Laser induced scattering method was used to measure the soot particle diameter and number density. Also, we measured temperature without the effect of soot particles attached to the thermocouple junction, which is close to the nozzle. In this result, we found that upstream zone has a unstable flowing in co-flow diffusion flame and the y-axis temperature of flame has a uniform temperature distribution in the most soot volume fraction zone.

  • PDF

초기 직경 변화가 Toluene 액적의 Soot 생성에 미치는 영향 (Effect of Initial Diameter on the Soot Generation of Toluene Fuel Droplet)

  • 임영찬;서현규
    • 한국분무공학회지
    • /
    • 제20권4호
    • /
    • pp.261-267
    • /
    • 2015
  • The main purpose of this study is to provide the information of soot generation of toluene fuel droplet. To achieve this, this paper provides the experimental results on the different initial diameter of toluene droplet combustion characteristics conducted under equivalent ambient pressure ($P_{amb}$) and oxygen concentration ($O_2$) conditions. Visualization of single fuel droplet was performed with high resolution CCD camera and visualization system. At the same time, ambient pressure ($P_{amb}$) and oxygen concentration ($O_2$) were maintained by ambient condition control system. Soot volume fraction ($f_v$) was analyzed and compared on the basis of intensity ratio ($I/I_0$) of background image. The result of soot generation was almost the same regardless of initial droplet diameter since thermophoretic flux is not much changed under the same ambient conditions. Soot standoff ratio (SSR) of 2 mm diameter showed unstable variation characteristics due to the short available measuring time.