• Title/Summary/Keyword: Sonography

Search Result 277, Processing Time 0.021 seconds

Evaluation of Medial Instability of the Knee with Ultrasonography - Technical note - (초음파를 이용한 슬관절 내측 불안정 평가 -측정기법-)

  • Kim, Jung-Man;Lee, Dong-Yeob;Koh, In-Jun;Kim, Seung-Min
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.73-77
    • /
    • 2008
  • Purpose: The purpose of this study was to describe the method of dynamic sonographic measurements in the evaluation of the MCL injury of the knee joint while applying valgus and varus stress. Materials and Methods: Seven cases of MCL injury from January to April of 2008 was used for the study. For the evaluation of the medial instability, sonography was used immediately after injury, 6 weeks and 12 weeks after conservative treatment with limited motion brace. The length between the foot of the medial femoral epicondyle and the most proximal point of the tibial cortex was measured in 30 degrees flexion with valgus and varus stress of the knee joint. Results: The foot of the medial epicondyle and the starting point of the proximal tibial cortex underneath the round portion of the articular cartilage were always able to be seen on ultrasonography, even in varus and valgus stress with gravity in 30 degrees flexion of the knee joint. The results of measurements were always constant. Conclusion: Sonography can be used in evaluation of medial instability under the dynamic valgus and varus stress of the knee joint without further injury.

  • PDF

Usefulness of External Monitoring Flap in the Buried Jejunal Free Flap (유리 공장 피판술 후 외부 감시 피판의 유용성)

  • Kim, Baek Kyu;Chang, Hak;Minn, Kyung Won;Hong, Joon Pio;Koh, Kyung Suck
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.432-435
    • /
    • 2007
  • Purpose: The jejunal free flap has the shorter ischemic time than other flap and requires a laparotomy to harvest it. As the evaluation of the perfusion the buried flap is very important, the perfusion of the buried jejunal free flap requires monitoring for its salvage. We tried to improve the monitoring flap method in the jejunal free flap and examined its usefulness. Methods: From March 2002 to March 2006, the monitoring flap method was applied to 4 cases in 8 jejunal free flaps for the pharyngeal and cervical esophageal reconstructions. The distal part of the jejunal flap was exposed without suture fixation through cervical wound for monitoring its perfusion. The status of perfusion was judged by the color change of jejunal mucosa and mesentery. If necessary, pin prick test was performed. Doppler sonography was applied to mesenteric pedicle of the monitoring flap in case of suspicious abnormal circulation. Results: The monitoring flap shows no change in 3 cases, but the congestion happened in one case at the 12 hours after the operation. This congestion was caused by the twisting or kinking of the mesenteric pedicle of the monitoring flap. So, we fixed up the monitoring flap close to adjacent cervical skin for prevention of rotation. Finally, the main part of transferred jejunal flap was intact. Conclusion: The success of a jejunal free flap depends on close postoperative monitoring and early detection of vascular compromise. So, various monitoring methods have been tried, for instance, direct visualization using a fiberoptic pharyngoscope, through a Silastic window placed in the neck flap, or external surface monitoring with an Doppler sonography, use of a buried monitoring probe. But, all of the above have their own shortcomings of simplicity, non-invasiveness, reliability and etc. In our experience, monitoring flap can be a accurate and reliable method.

Analysis of increased nuchal translucency: Chorionic villi sampling and second-trimester level II sonography

  • Park, Ji Eun;Park, Ji Kwon;Cho, In Ae;Baek, Jong Chul;Kang, Min Young;Lee, Jae Ik;Shin, Jeong Kyu;Choi, Won Jun;Lee, Soon Ae;Lee, Jong Hak;Paik, Won Young
    • Journal of Genetic Medicine
    • /
    • v.11 no.2
    • /
    • pp.56-62
    • /
    • 2014
  • Purpose: To assess the outcomes of increased fetal nuchal translucency (NT), to aid in prenatal counseling and management in our practice. Materials and Methods: We retrospectively reviewed the medical records of patients who underwent first trimester fetal karyotyping using chorionic villi sampling (CVS) and second trimester level II sonography for a fetal NT thickness ${\geq}3.0mm$ between 11 weeks and 13 weeks 6 days' gestation, at Gyeongsang National University Hospital. Pediatric medical records and a telephone interview were used to follow-up live-born children. Exclusion criteria included incomplete data and CVS for other indications. Results: Seventy cases met the inclusion criteria (median NT thickness, 4.7 mm; range, 3.0-16.1 mm). Twenty-nine cases (41.4%) were aneuploid. The prevalence of chromosomal defects increased with NT thickness: NT 3.0-3.4 mm, 16.7%; NT 3.5-4.4 mm, 27.3%; NT 4.5-5.4 mm, 66.7%; NT 5.5-6.4 mm, 37.5%; NT ${\geq}6.5mm$, 62.5%. The most common karyotype abnormality was trisomy 18 (n=12), followed by trisomy 21 (n=9). In chromosomally normal fetuses (n=41), fetal death occurred in 2 cases (4.9%), and structural malformations were found in 11 cases (26.8%). In chromosomally and anatomically normal fetuses (n=28), one child had neurodevelopmental delay (3.6%). Twenty-eight infants who had a prenatal increased NT were alive and well at follow-up (40%). Conclusion: Outcomes of increased fetal NT might help inform prenatal counseling and management. The high prevalence of chromosomal defects associated with increased fetal NT implies that CVS should be performed in the first trimester, particularly considering the stress associated with an uncertain diagnosis.

Effects of LI11 Acupuncture on CO2 reactivity in the anterior and middle cerebral arteries during hyperventilation-induced hypocapnia in normal subjects: A before and after study.

  • Kim, Gyeong-muk;Jung, Woo-Sang;Kwon, Seungwon;Jin, Chul;Cho, Seung-Yeon;Park, Seong-Uk;Moon, Sang-Kwan;Park, Jung-Mi;Ko, Chang-Nam;Cho, Ki-Ho
    • The Journal of Korean Medicine
    • /
    • v.42 no.4
    • /
    • pp.164-175
    • /
    • 2021
  • Objectives: The LI11 (Quchi) acupuncture point has always been included in the Seven acupoints for stroke; however, additional LI11 acupuncture research is needed. In this study, the effect of LI11 acupuncture on cerebral blood flow of the anterior cerebral arteries (ACA) and middle cerebral arteries (MCA) was investigated. Method: This study included 10 healthy young male subjects. Cerebral blood flow velocity and cerebrovascular reactivity were measured using transcranial Doppler sonography. Changes in hyperventilation-induced carbon dioxide (CO2) reactivity and modified ACA and MCA blood flow velocity at 40 mmHg (CV40), blood pressure, and heart rate were observed before and after LI11 acupuncture treatment. Results: A statistically significant increase in contralateral anterior cerebral artery CO2 reactivity (p=0.036) and decrease in contralateral middle cerebral artery CV40 (p=0.047) were observed. No significant difference in mean blood pressure was shown. A statistically significant increase in heart rate occurred after LI11 acupuncture; however, it was not clinically significant as there were negligible changes in the heart rhythm. Conclusions: LI11 acupuncture treatment could improve cerebral blood flow velocity. These results might be explained by regulating endothelium-dependent vessel dilation in the anterior cerebral artery region. Trial registration: This trial has been registered with Clinical Research Information Service, a service of the Korea Centers for Disease Control and Prevention: KCT0004494 (retrospectively registered). https://cris.nih.go.kr/cris/search/search_result_st01.jsp?seq=15359

A Case of Neurofibromatosis Combined with Ectopic Kidney (이소성 신장을 동반한 신경섬유종 1례)

  • Yang, Eu Gene;Kim, Bo Hyun;Lee, Joon Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.4
    • /
    • pp.448-452
    • /
    • 2005
  • Neurofibromatosis(NF) is an autosomal dominant disorder, probably of neural crest origin that affects all three germinal layers. It is a group of heterogeneous multisystemic neurocutaneous disorders involving both neuroectodermal and mesenchymal derivatives. Type 1(von Recklinghausen disease) is the most common neurocutaneous disorder among the eight subtypes. Previous reports showed various involvements in the renal organ. Renovascular hypertension is the most common major manifestation of renal involvement in this disease. However, we experienced a case of ectopic kidney concurrent with neurofibromatosis type 1. The diagnosis of neurofibromatosis had been made by typical skin manifestation on physical examination, and ectopic kidney was discovered accidentally during routine abdominal sonography. The etiological basis of this association is not clear. We report a rare case of coexisting neurofibromatosis and ectopic kidney in a 7-year-old girl with a brief review.

Usefulness of FAST for Evaluation of Blunt Abdominal Trauma Patients (복부둔상 환자의 혈복강 진단에 있어 FAST의 유용성에 대한 고찰)

  • Chu, Yong Sik;Kim, Ok Jun;Choi, Sung Uk;Lee, Jung Han
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.135-142
    • /
    • 2006
  • Purpose: We planned to determine the diagnostic capability of focused assessment with sonography for trauma (FAST) in cases of blunt abdominal injury (BAI). Methods: A retrospective analysis of FAST sheets was performed from April 2002 to December 2004. During the study period, 135 BAI patients were evaluated with FAST at the Emergency Department of Bundang CHA Hospital. Of this group, twenty-eight patients were excluded, leaving 107 patients for analysis. Abdomen CT (computerized tomography) or exploratory laparotomy confirmed the presence of hemoperitoneum. At the secondary survey, patients underwent a three-view FAST examination (LogicQ; General Electric, Waukesha, USA) by an emergency physician, followed within 2 hours by an abdomen CT or exploratory laparotomy. The FAST examination was considered positive if it demonstrated evidence of free intra-abdominal fluid. Results: There were 45 true-positive FAST examination, 57 true-negatives, 1 false-positive, and 4 false negatives (sensitivity 91.8%, specificity 98.3%, positive predictive value 97.8%, negative predictive value 93.4%). The area under the ROC curve was 0.951 for the FAST examination. Conclusion: FAST is a highly reliable method for screening patients suspected of having BAI for the presence or absence of hemoperitoneum.

Current Status of Health Screening in Korea (한국의 건강검진 현황)

  • Jo, Han-Ik
    • Journal of Korea Association of Health Promotion
    • /
    • v.2 no.3
    • /
    • pp.73-96
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items and methods should be carefully selected. This study was to get hold of the test items of major health screening programs in Korea Most of the health screening programmes focused upon detection of risk factors and diagnosis of life - style related diseases (diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis) ,cancers (stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus) , infectious diseases (hepatitis, tuberculosis, sexually-transmitted diseases, parasites) , chronic obstructive respiratory diseases, chronic renal diseases (bacteriuria hematuria, proteinuria) , anemia, glaucoma, hearing loss, Alzheimer disease, stress, early psychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests (CBC, urinalysis, liver function tests, lipid tests, glucose, HbAlc, uric acid, electrolytes, serological tests (HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray (chest PA, CT) , endoscopy (gastroscopy, colonoscopy) , sonography(abdomen, thyroid, pelvis, breast) ,cytology (cervix) , bone density, tumor markets (NMP22, alpha-FP, CEA, CA-19-9, CA12S, PSA) and eye tests. Advanced technologies, like CT, PET, MRI, MRT/Angio, molecular testings) were widely used in hospital health screening programmes .In summary, a variety of tests were utilized in health screening in Korea. Those tests were utilized by stages or according to sex and age in most of health screening programmes, however a few program used tests to excess disregarding health screening subjects.

  • PDF

국내 주요 기관의 건강진단 검사 종목

  • Jo, Han-Ik;Kim, Sang-In
    • Journal of Korea Association of Health Promotion
    • /
    • v.2 no.1
    • /
    • pp.9-25
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items of major health screening program in Korea. Most, of the health screening programmes focused upon detection of risk factors and diagnosis of life-style related diseases(diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis), cancers(stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus), infections diseases(hepatitis, tuberculosis, sexually-transmitted diseases, parasites), chronic obstructive respiratory diseases, chronic renal diseases(bacteriuria, hematuria, proteinuria), anemia, glaucoma, hearing loss, Alzheimer disease, stress and earlypsychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests( CBC, urinalysis, liver function tests, lipid tests, glucose, HbA1c, uric acid, electrolytes, serological tests(HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray(chest PA, CT) endoscopy(gastroscopy, colonoscopy), sonography (abdomen, thyroid, pelvis, breast), cytology(cervix), bone density, tumor markers(NMP22, alpha-FP, CEA, CA-19-9, CA125, PSA and eye tests. Advanced technologies, like CT, PET, MRI, MRI/Angio, molecular testing were widly used in hospital based health screening programmes. In summary, a variety of tests were untilized in health screening in Korea. Those tests were utilized by stages or according to sex and age in most of health screening programmes, however a few programs used tests excessvely disregarding health screening subjects.

  • PDF

Association Between Physical Activity and Quantitative Ultrasound in a Rural Population (신체활동과 골초음파지표와의 연관성)

  • Kim, Seung-Joon;Shin, Min-Ho;Kweon, Sun-Seog
    • Physical Therapy Korea
    • /
    • v.12 no.2
    • /
    • pp.20-27
    • /
    • 2005
  • Osteoporosis is characterized by low bone mass and the microarchitectural deterioration of bone tissue with a consequent increase in bone fragility and susceptibility to fracture. It has been suggested that speed of sound (SOS) and broadband ultrasound attenuation (BUA) of quantitative ultrasound sonography (QUS) may provide information about not only bone density but also the microarchitecture and elastic properties of bone. Physical inactivity reduced mechanical usage and it made process to the bone changes. This study aimed to association between the physical activity and the QUS parameters in 1305 (593 men, 712 women) aged 20 years over in a rural population. Two QUS parameters, BUA (p=.23) and SOS(p=.73) were measured at the right calcaneus of postmenopausal women, no significant associations were observed between sports index and SOS and BUA. These results suggest that work, non-sports leisure physical activity (p<.01) have a significant influence on QUS parameters in a rural population. Physical activity are meaningful predictor of QUS parameters of the calcaneus in a rural population.

  • PDF

Diagnostic Consistency between Sonoelastography and Conventional Sonography of Long Head of the Biceps

  • Yoon, Sunghyun;Seo, Joong-Bae;Yoo, Jae-Sung;Ryu, Jee-Won
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.3
    • /
    • pp.107-113
    • /
    • 2014
  • Background: Sonoelastography (SE) is a new technique that can assess differences in tissue stiffness, the purpose of this study was to evaluate the ability of SE to assess the long head of biceps tendon alteration. Methods: Forty shoulders of 36 consecutively registered patients with clinical symptoms and conventional ultrasonography findings of biceps tendinitis or tendinosis, and 40 asymptomatic shoulders of 20 healthy volunteers were assessed with SE. Transverse and longitudinal images of long head of biceps tendon were obtained using SE. SE images were performed by one orthopedic surgeon and evaluated by two orthopedic surgeons using an experimentally proven color grading system. Results: The transverse images of SE showed a sensitivity of 87.5%, a specificity of 95.0% and a accuracy of 91.3%, the longitudinal images of SE showed a sensitivity of 92.5%, a specificity of 90.0% and a accuracy of 91.3%. Inter-observer reliability of SE was in 'almost perfect agreement' with a weighted kappa coefficient of 0.83. Conclusions: SE is valuable in the detection of the intratendinous and peritendinous alterations of biceps tendon, and has excellent accuracy and excellent correlation with conventional ultrasound findings.