• Title/Summary/Keyword: Song Mode

Search Result 1,054, Processing Time 0.033 seconds

A Study of Analysis for Impact Assessment of the Cost Risk-Factor on the Design-Build Projects based on Business Process (설계시공일괄방식 사업의 업무단계별 사업비용 리스크요인에 대한 영향도 평가 및 분석)

  • Seo, Jae-Pil;Lee, Sang-Hyun;Song, Young-Woong;Choi, Yoon-Ki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.3
    • /
    • pp.14-24
    • /
    • 2012
  • Recently, a delivery system has been rapidly changed in the global construction market. Also, construction projects are becoming bigger and more technology-intensive. A lot of projects have been delivered by Design-Build(DB) System; from the standpoint of cost, approximately 40% of delivered constructions by a Public Procurement Service were DB in 2009. Nevertheless, the achievement has not surpassed our expectations on management of the project cost. On the characteristic of DB, the reasons why that happens are that projects contract have been signed after the Design Development Stage; the insufficient review about new technology and up-to-date construction methods; a lack of discussion in process of design. Those reasons cause a risk of increasing Cost of the projects. In order to solve these problems, it is desirable to find Cost-increasing factors in promoting the projects and select on the order of priority for Risk-Factor with careful management. Therefore, this study analyzed the weight of each phase of the project on the authority of properties of DB project, and identified Risk-factors which is increasing the cost on the aspect of project management. Based on this analysis, the impact assessment of Risk-factor is evaluated through the Failure Mode and Effect Analysis(FMEA).

Compositions of haze aerosols and their variation by inflow pathway of air mass at Gosan site in Jeju Island during 2012-2013 (연무 에어로졸의 조성 및 기류 유입경로별 변화: 2012-2013년 제주도 고산지역 측정)

  • Hyeon, Dong-Rim;Song, Jung-Min;Kim, Ki-Ju;Kim, Won-Hyung;Kang, Chang-Hee;Ko, Hee-Jung
    • Analytical Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.213-222
    • /
    • 2014
  • The atmospheric aerosols of $PM_{10}$ and $PM_{2.5}$ were collected at Gosan site of Jeju Island during 2012- 2013. Their ionic and elemental species were analyzed in order to examine the composition variation of the haze aerosols in accordance with the pathway of air mass. The concentrations of $nss-SO_4{^{2-}}$, $NO_3{^-}$, and $NH_4{^+}$ increased 2.1~3.7 times in coarse particle and 3.1~6.5 times in fine particle modes, respectively, showing especially high $NO_3{^-}$ concentrations in fine particles during the haze days. The concentrations of S, Zn, Pb and K increased 3.0~5.6 times in coarse particles and 3.2~7.7 times in fine particles during the haze days, on the other hand Al, Fe, and Ca concentrations were high only in coarse particles. Due to the back trajectory analysis, the concentrations of $nss-SO_4{^{2-}}$ and $NO_3{^-}$ for haze days were high when the inflow pathway of air mass was from China, especially a high increase of $NO_3{^-}$ as through the south of China. The $NO_3{^-}/nss-SO_4{^{2-}}$ concentration ratio was relatively high in coarse mode as air mass inflow from China, but in fine mode it was high as air mass passing through the Korean peninsula.

Validation of LC-MS/MS method for determination of ginsenoside Rg1 in human plasma (인체 혈장 중 Ginsenoside Rg1의 정량을 위한 LC-MS/MS 분석법 검증)

  • Kim, Yunjeong;Han, Song-Hee;Jeon, Ji-Young;Hwang, Min-Ho;Im, Yong-Jin;Lee, Sun Young;Chae, Soo-Wan;Kim, Min-Gul
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.221-227
    • /
    • 2013
  • A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the investigation of the ginsenoside Rg1 in human plasma. After addition of internal standard (digoxin), plasma was diluted with acetone and methanol (80:20), the supernatant was concentrated and analyzed by LC-MS/MS. The optimal chromatographic separation was achieved on an Agilent Eclipse XDB-C18 column ($4.6{\times}150mm$, $5{\mu}m$) with a mobile phase of 0.1% formic acid in water and 0.1% formic acid in methanol at a flow rate of 0.9 mL/min gradient mode. The standard calibration curve for ginsenoside Rg1 was linear ($r^2=0.9995$) over the concentration range 1~500 ng/mL in human plasma. The intra- and inter-day precision over the concentration range of ginsenoside Rg1 was lower than 7.53% (correlation of variance, CV), and accuracy exceeded 98.28%. This LC-MS/MS assay of ginsenoside Rg1 in human plasma is applicable for quantifying in the pharmacokinetic study.

Design of a PWM DC-DC Boost Converter IC for Mobile Phone Flash (휴대전화 플래시를 위한 PWM 전류모드 DC-DC converter 설계)

  • Jung, Jin-Woo;Heo, Yun-Seok;Park, Yong-Su;Kim, Nam-Tae;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2747-2753
    • /
    • 2011
  • In this paper, a PWM current-mode DC-DC boost converter for mobile phone flash application has been proposed. The converter which is operated with 5 Mhz high switching frequency is capable of reducing mounting area of passive devices such as inductor and capacitor, consequently is suitable for compact mobile phones. This boost converter consists of a power stage and a control block. Circuit elements of the power stage are inductor, output capacitor, MOS transistors and feedback resistors. Meanwhile, the control block consists of pulse width modulator, error amplifier, oscillator etc. Proposed boost converter has been designed and verified in a $0.5\;{\mu}m$ 1-poly 2-metal CMOS process technology. Simulation results show that the output voltage is 4.26 V in 3.7 V input voltage, output current 100 mA which is larger than 25 ~ 50 mA in conventional 500 Khz driven converter when the duty ratio is 0.15.

Analyzing of CDTA using a New Small Signal Equivalent Circuit and Application of LP Filters (새로운 소신호 등가회로를 활용한 CDTA의 해석 및 저역통과 필터설계)

  • Bang, Junho;Song, Je-Ho;Lee, Woo-Choun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7287-7291
    • /
    • 2014
  • A CDTA (current differencing transconductance amplifier) is an active building block for current mode analog signal processing with the advantages of high linearity and a wide frequency bandwidth. In addition, it can generate a stable voltage because all the differencing input current flows to the grounded devices. In this paper, a new small signal equivalent circuit is proposed to analyze a CDTA. The proposed small signal equivalent circuit provides greater precision in analyzing the magnitude and frequency response than its previous counterparts because it considers the parasitic components of the input, internal and output terminal. In addition, observations of the changes made in various devices, such as the resistor (Rz) confirmed that those devices heavily influence the characteristics of CDTA. The designed parameters of the proposed small signal equivalent circuit of the CDTA provides convenience and accuracy in the further design of analog integrated circuits. For verification purposes, a 2.5 MHz low pass filter was designed on the HSPICE simulation program using the proposed small signal equivalent circuit of CDTA.

Evaluation of Fracture Behavior of Adhesive Layer in Fiber Metal Laminates using Cohesive Zone Models (응집영역모델을 이용한 섬유금속적층판 접착층의 모드 I, II 파괴 거동 물성평가)

  • Lee, Byoung-Eon;Park, Eu-Tteum;Ko, Dae-Cheol;Kang, Beom-Soo;Song, Woo-Jin
    • Composites Research
    • /
    • v.29 no.2
    • /
    • pp.45-52
    • /
    • 2016
  • An understanding of the failure mechanisms of the adhesive layer is decisive in interpreting the performance of a particular adhesive joint because the delamination is one of the most common failure modes of the laminated composites such as the fiber metal laminates. The interface between different materials, which is the case between the metal and the composite layers in this study, can be loaded through a combination of fracture modes. All loads can be decomposed into peel stresses, perpendicular to the interface, and two in-plane shear stresses, leading to three basic fracture mode I, II and III. To determine the load causing the delamination growth, the energy release rate should be identified in corresponding criterion involving the critical energy release rate ($G_C$) of the material. The critical energy release rate based on these three modes will be $G_{IC}$, $G_{IIC}$ and $G_{IIIC}$. In this study, to evaluate the fracture behaviors in the fracture mode I and II of the adhesive layer in fiber metal laminates, the double cantilever beam and the end-notched flexure tests were performed using the reference adhesive joints. Furthermore, it is confirmed that the experimental results of the adhesive fracture toughness can be applied by the comparison with the finite element analysis using cohesive zone model.

Foliar ultrastructure of Korean Orostachys species (한국산(韓國産) 바위솔속(屬) 엽육조직(葉肉組織)의 미세구조(微細構造))

  • Kim, In-Sun;Pak, Jae-Hong;Seo, Bong-Bo;Song, Seung-Dal
    • Applied Microscopy
    • /
    • v.25 no.4
    • /
    • pp.52-61
    • /
    • 1995
  • Ultrastructural characteristics were examined with leaves of three species, O. japonicus A. Berger, O. malacophyllus Fisch., and O. sikokianus Owhi that probably have CAM mode. The mesophyll cells of these Orostachys possessed vacuoles with precipitates, myelin-like figures, and plasmalemmasomes, along with typical chloroplasts, microbodies and darkly stained bodies in their thin peripheral cytoplasm. Separation of the plasmalemma from the cell wall, leaving a space between them, was a common phenomenon in these species. A complex array of small to large vacuoles which contain small, membrane-bounded vesicles or vacuole-like structures were frequently found. A well-developed thylakoid system was observed in the chloroplasts and this indicates that the photosynthetic capacity of these mesophyll cells is probably active. A peculiar configuration of cytoplasm, especially around the chloroplasts, was also encountered. The variety of cytoplasmic constituents and vacuoles suggest the water-storing mesophyll cells may be complex in function. Some cellular features detected in this study strongly suggest the possible occurrence of CAM mode in Orostachys species.

  • PDF

Digital Tomosynthesis for Patient Alignment System Using Half-fan Mode CBCT Projection Images (Half-fan 모드를 이용한 방사선치료환자 위치교정을 위한 디지털영상 합성영상기술에 관한 예비연구)

  • Park, Justin C.;Park, Sung-Ho;Kim, Jin-Sung;Han, Young-Yih;Ju, Sang-Gyu;Shin, Eun-Hyuk;Shin, Jung-Suk;Park, Hee-Chul;Ahn, Yong-Chan;Song, Willian Y.
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.360-366
    • /
    • 2010
  • To generate on-board digital tomosynthesis (DTS) for three-dimensionalimage-guided radiation therapy (IGRT) as an alternative to conventional portal imaging or on-board cone-beam computed tomography (CBCT), two clinical cases (liver and bladder) were selected to illustrate the capabilities of on-board DTS for IGRT. DTS images were generated from subsets of CBCT projection data (45, 162 projections) using half-fan mode scanning with a Feldkamp-type reconstruction algorithm. Digital tomosynthesis slices appeared similar to coincident CBCT planes and yielded substantially more anatomic information. Improved bony and soft-tissue visibility in DTS images is likely to improve target localization compared with radiographic verification techniques and might allow for daily localization of a soft-tissue target. Digital tomosynthesis might allow targeting of the treatment volume on the basis of daily localization.

Fiber-optic Temperature Sensor Using a Silicone Oil and an OTDR (OTDR을 이용한 실리콘 오일 기반의 광섬유 온도 센서)

  • Jang, Jae Seok;Yoo, Wook Jae;Shin, Sang Hun;Lee, Dong Eun;Kim, Mingeon;Kim, Hye Jin;Song, Young Beom;Jang, Kyoung Won;Cho, Seunghyun;Lee, Bongsoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.11
    • /
    • pp.1592-1597
    • /
    • 2015
  • In this study, we developed a fiber-optic temperature sensor (FOTS) based on a silicone oil and an optical time domain reflectometer (OTDR) to apply the measurement of a coolant leakage in the nuclear power plant. The sensing probe of the FOTS consists of a silicone oil, a stainless steel cap, a FC terminator, and a single mode optical fiber. Fresnel reflection arising at the interface between the silicone oil and the single mode optical fiber in the sensing probe is changed by varying the refractive index of the silicone oil according to the temperature. Therefore, we measured the optical power of the light signals reflected from the sensing probe. The measurable temperature range of the FOTS using a Cu-coated silica fiber is from $70^{\circ}C$ to $340^{\circ}C$ and the maximum operation temperature of the FOTS is sufficient for usage at the secondary system in the nuclear power plant.

Inter-hospital Comparison of Cesarean Section Rates after Risk Adjustment (위험도 보정을 통한 병원간 제왕절개 분만율의 비교)

  • Lee, Sang-Il;Ha, Beom-Man;Lee, Moo-Song;Kang, Wee-Chang;Koo, Hee-Jo;Kim, Chang-Yup;Khang, Young-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.4
    • /
    • pp.337-346
    • /
    • 2001
  • Objective : To determine the clinical risk factors associated with the mode of delivery decision and to compare cesarean section rates after adjusting for risk factors identified among Korean hospitals. Methods Data were collected from 9 general hospitals in two provincial regions by medical record abstraction during February 2000. A total of 3,467 cases were enrolled and analyzed by stepwise logistic regression. Performance of the risk-adjustment model (discrimination and calibration) was evaluated by the C statistic and the Hosmer-Lemeshow test. Crude rates, predicted rates with 95% confidence intervals, and adjusted rates of cesarean section were calculated and compared among the hospitals. Results : The average crude cesarean section rate was 53.2%, ranging from 39.4% to 65.7%. Several risk factors such as maternal age, previous history of cesarean section, placenta previa, placental abruption, malpresentation, amniotic fluid abnormality, gestational anemia, infant body weight, pregnancy-induced hypertension, and chorioamnionitis were found to have statistically significant effects on the mode of delivery. It was confirmed that information about most of these risk factors was able to be collected through the national health insurance claims database in Korea. Performance of the risk-adjustment model was good (c statistic=0.815, Hosmer-Lemeshow test=0.0621). Risk factor adjustment did lead to some change in the rank of hospital cesarean section rates. The crude rates of three hospitals were beyond 95% confidence intervals of the predicted rates. Conclusions : Considering that cesarean section rates in Korean hospitals are too high, it is apparent that some policy interventions need to be introduced. The concept and methodology of risk adjustment should be used in the process of health policy development to lower the cesarean section rate in Korea.

  • PDF