• 제목/요약/키워드: Solution Plasma

검색결과 735건 처리시간 0.028초

뉴로메드정(옥시라세탐 800 mg)에 대한 뉴라세탐정의 생물학적동등성 (Bioequivalence of Neuracetam Tablet to Neuromed Tablet (Oxiracetam 800 mg))

  • 최성업;김종석;윤미경;김정일;박석;한상범;이재휘;최용욱
    • Journal of Pharmaceutical Investigation
    • /
    • 제34권3호
    • /
    • pp.215-222
    • /
    • 2004
  • The purpose of the present study was designed to evaluate the bioequivalence of two oxiracetam tablets, Neuromed tablet (Korea Drug Co., reference drug) and Neuracetam tablet (Sam Jin Pharmaceutical Co., test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Release of oxiracetam from the tablet in vitro was tested using KP VIII Apparatus II method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty-four healthy volunteers, $23.7\;{\pm}\;2.4$ year in age and $68.9\;{\pm}\;6.2$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was performed. After oral administration of a tablet containing 800 mg of oxiracetam, blood samples were taken at predetermined time intervals and concentrations of oxiracetam in plasma were determined using HPLC-MS-MS. The dissolution profiles of two formulations were very similar at all dissolution media. In addition, pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$ and $C_{max}$ untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug were 0.42%, 0.45% and -12.58% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals for the log transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., $log0.94{\sim}log1.06$ and $log0.90{\sim}log1.07$ for $AUC_t$, and $C_{max}$, respectively), indicating that Neuracetam tablet is bioequivalent to Neuromed tablet. The major pharmacokinetic parameters, $AUC_t$, and $C_{max}$ met the criteria set by KFDA for bioequivalence indicating that Neuracetam tablet is bioequivalent to Neuromed tablet.

모의 사용후핵연료에 함유된 루테늄의 양이온교환 분리 및 정량 (Cation Exchange Separation and Determination of Ruthenium in a Simulated Spent Nuclear Fuel)

  • 서무열;손세철;이창헌;최광순;김도양;박영재;박경균;지광용;김원호
    • 대한화학회지
    • /
    • 제44권6호
    • /
    • pp.526-532
    • /
    • 2000
  • 사용후핵연료에 미량 함유되어 있는 루테늄 분석법을 개발하기 위하여 양이온교환법을 이용한 분리 조건을 조사하였다. 산분해 장치를 사용하여 9:1 몰비의 혼합산($HCl-HNO_3$)으로 루테늄 시료를 용해시켰다. 염산 용액에서 루테늄의 흡수스펙트럼과 이온교환 거동 조사를 통해 분리에 관련된 루테늄의 화학종을 제시하였다. 미량의 루테늄이 함유되어 있는 우라늄 용액을 양이온교환수지(AG 50W ${\times}$ 8, 100~200 mesh) 분리관(0.7 ${\times}$ 8.0 cm)에 넣고 0.5 M 염산으로 루테늄을 용리시켰다. 모의 사용후핵연료에 확립된 루테늄 분리방법을 적용하고 유도결합 플라스마 원자방출분광분석법으로 분석한 결과 루테늄 회수율은 98.5%이었다.

  • PDF

샥스핀 가공 중 사용된 메타규산나트륨 분석 (Analytical Method to Quantify Sodium Metasilicate in Shark Fins)

  • 박세종;장수진;최재천;김미혜
    • 한국식품과학회지
    • /
    • 제47권2호
    • /
    • pp.145-148
    • /
    • 2015
  • 메타규산나트륨은 우리나라 식품첨가물공전에 등록되어 있는 품목으로 식용유지류의 여과보조제의 목적 이외에는 사용할 수 없으며, 최종식품 완성 전에 제거하도록 규정되어 있다. 그러나 최근 샥스핀 등 수산물에 중량 증량의 목적으로 메타규산나트륨을 불법 사용하는 사례가 지속적으로 발생함에 따라 메타규산나트륨의 사용 여부를 판별할 수 있는 분석법의 필요성이 대두되고 있다. 그러나 메타규산나트륨의 수용액은 강알칼리성용액으로 식품에 첨가되면 해리되어 그 자체로 분석할 수 없으며, 규소 양의 측정을 통해 간접적인 방법으로 추정할 경우 시료 자체에 천연적으로 존재하는 규소와 구분해야 하는 어려움이 있다. 따라서 본 연구에서는 메타규산나트륨의 첨가 여부를 판별하기 위한 기초 자료 확보를 위해 메타규산나트륨 수용액에 가공되지 않은 상어지느러미를 침지하여 중량의 증가, pH 및 규소 함량 변화를 측정하였고, 이를 모니터링 결과와 비교하였다. 그러나 Robberecht 등(7)의 연구결과 6종의 어류에서 규소가 1.77-84.19 mg/kg의 범위에서 검출된 결과에서 알 수 있듯이, 수산물의 종류와 개체 간에 규소 함량의 편차가 크게 나타날 수 있기 때문에 향후 샥스핀의 규소 함량 모니터링을 지속적으로 수행하여 데이터베이스를 좀 더 보강할 필요가 있을 것으로 판단되며, 그 이후에 대조군과 pH, 수분 및 규소 함량 비교를 통해 메타규산나트륨 사용여부를 유추해 볼 수 있을 것으로 생각된다.

개심술중 심폐우회 충전용객속에서의 10% 펜타스타치와 20% 알부민의 임상 비교 (The Clinical Comparisons of 10% Pentastarch and 20% Albumin in Priming Solutions for Cardiopulmonary Bypass in Cardiac Operations)

  • 백만종
    • Journal of Chest Surgery
    • /
    • 제27권2호
    • /
    • pp.99-113
    • /
    • 1994
  • Pentastarch is a new synthetic hydroxyethyl starch similar to hetastarch. We report on the clinical comparisons the clinical efficacy and safety of 10% pentastarch in prime solutions for CPB in cardiac operations with that of 20% serum albumin. During CPB, group P [n = 20] received 500ml of 10% pentastarch and group A [n = 20] received 100ml of 20% albumin in prime solutions The postoperative time of ICU stay in group P and the day and amount of chest drain, hospital stay in group A were longer [p<0.05]. Fresh whole blood and PRBC were added only in group A and a higher amount of hartman solution was added in group A during CPB [p<0.05]. Prothrombin time was prolonged preoperatively and 2 days postoperatively in group A and 7 days postoperatively in group P [p<0.05] but there were no significant differences in bleeding time or fibrinogen level. Platelet count was higher immediately postoperatively in group A and preoperatively and 1, 2, and 7 days postoperatively in group P [p<0.05].Total protein and albumin level were higher 1 day postoperatively in group A and 2 and 7 days postoperatively in group P [p<0.05]. BUN was increased 2 days postoperatively in group A and Cr was increased 1 day postoperatively in group P [p<0.05]. CPK was higher preoperatively and 1, 2, and 7 days postoperatively in group A and plasma hemoglobin level was also higher 2 and 7 days postoperatively in group A [p<0.05]. There were no significant differences in arterial blood gas analysis but higher pO2 and lower pCO2 levels were maintained in group P and ejection fraction was higher 7 days postoperatively in group P [p<0.05]. Both groups were improved postoperatively in NYHA class and the hemodynamic parameters such as MAP, CO, CI, SV, LVSWI were well maintained in group P [p<0.05]. The amount of blood products used was higher in group A and urine output was higher immediately postoperatively in group A and 1, 2 days postoperatively in group P and the chest output was higher in group A. The complications were developed in 7 patients in group A and 5 patients in group P and mortality was not present in both groups.In conclusion, 10% pentastarch is as safe and effective as 20% albumin in prime solutions for cardiopulmonary bypass in cardiac operations.

  • PDF

TiO2/SiO2 박막 코팅에 의한 폴리카보네이트 특성 개선 (Improvement of Polycarbonate Properties by Coating of TiO2 and SiO2 Thin Film)

  • 원동수;이원규
    • 공업화학
    • /
    • 제25권1호
    • /
    • pp.41-46
    • /
    • 2014
  • 폴리카보네이트의 표면에 무기계 $SiO_2$ 박막을 바인더로 코팅한 후 광촉매 특성을 갖는 $TiO_2$ 박막을 추가로 형성하여 모재의 특성을 향상시키는 연구가 수행되었다. 바인더로 사용되는 $SiO_2$ 박막은 광투과 특성이 우수하며, 상압플라즈마처리를 통한 친수성의 증가로 $TiO_2$ 함유 수용액의 도포성을 향상시켜 균일한 박막을 형성시킬 수 있었다. 약 200 nm이상으로 코팅된 $TiO_2$ 박막은 180~400 nm의 자외선을 차단하여 폴리카보네이트의 황변현상을 억제하고 내열성을 크게 향상하는데 기여하였다. 최외층에 형성된 $TiO_2$ 박막은 자외선의 흡수로 활성화되는 표면산화특성으로 유기 오염물의 분해반응 촉진과 표면의 친수성의 증가에 따른 자기세정특성을 나타내었다. $TiO_2$ 박막과 폴리카보네이트 기재 사이에 $SiO_2$ 박막의 적용은 기재의 부식에 의한 코팅된 $TiO_2$ 층의 박리를 억제하여 구조 안정성을 유지할 수 있었다.

다중벽 탄소 나노 튜브, 전도성고분자 및 티로시나아제 효소로 구성된 나노복합체를 이용한 비스페놀A 맞춤형의 전기화학적 검출법 (Electrochemical Determination of Bisphenol A Concentrations using Nanocomposites Featuring Multi-walled Carbon Nanotube, Polyelectrolyte and Tyrosinase)

  • 구나영;변아영;이혜진
    • 공업화학
    • /
    • 제32권6호
    • /
    • pp.684-689
    • /
    • 2021
  • 본 논문에서는 경제적이며 일회용 센서칩으로 제작 가능한 스크린프린팅한 탄소칩 전극[screen printed carbon electrode(SPCE)]에 다중벽 탄소 나노 튜브, 전도성고분자 및 티로시나아제를 융합하여 제작된 나노복합체를 도포한 센서를 개발하고 이를 내분비 저하 물질이면서, 비만, 당뇨병 및 심혈관질환 등의 만성질환 및 성조숙증, 여성 생식 질환, 불임 등과 관련성이 입증된 비스페놀A 농도 분석에 적용하고자 하였다. 다중벽 탄소 나노 튜브를 산화시켜 음전하를 띠게 한 후 양전하를 띠는 전도성고분자인 polydiallyldimethylammonium (PDDA)로 감싸준 후 용액의 pH를 조절하여 음전하를 띠게 한 티로시나아제를 첨가하여 최종적으로 산화된 다중벽 탄소 나노 튜브-PDDA-티로시나아제 나노복합체를 형성하였다. 상기 나노복합체를 물리적으로 흡착시킨 센서칩 표면을 비스페놀A 용액에 접촉시키고, 비스페놀A가 티로시나아제와 2단계의 효소-기질반응을 할 수 있는 충분한 시간(3분)을 주면, 생성물[4,4'-isopropylidenebis(1,2-benzoquinone)]이 생성된다. 이 때 순환전압전류법과 시차펄스전압전류법을 이용하여 생성물[4,4'-isopropylidenebis(1,2-benzoquinone)]을 환원(-0.08V vs. Ag/AgCl)하였을 때 얻어진 전류값 변화를 측정하여 비스페놀A의 농도를 정량적으로 분석하였다. 추가적으로 개발한 센서 전극표면에 비스페놀A와 유사한 비스페놀S 방해물질을 비스페놀A와 함께 접촉하였을 때 비스페놀A에 대한 우수한 선택성을 확인하였다. 최종적으로 제작한 센서를 실험실에서 제작한 환경 시료안에 비스페놀A의 농도를 분석하는 데 적용함으로써 실제 현장에서 활용될 수 있는 가능성을 시사하였다.

타이타늄-질소 코팅된 금속관에 대한 평가: 표면 경도, 부식 저항성, 색조 안정성 (Evaluation of Titanium-nitride Coated Crown: Surface Hardness, Corrosion Resistance and Color Sustainability)

  • 김효진;임수민;김진영
    • 대한소아치과학회지
    • /
    • 제48권3호
    • /
    • pp.344-351
    • /
    • 2021
  • 이 연구의 목적은 타이타늄-질소 코팅된 금속관(TiNCs)의 표면 경도와 스테인리스 스틸 금속관(SSCs)의 표면 경도를 비교하고, TiNCs의 부식 저항성 및 물리적 자극에 대한 금색 코팅의 안정성을 평가하는 것이다. 표면 경도 시험을 위해 10개의 TiNCs와 10개의 SSCs를 사용하였다. 각 금속관 종류당 총 30번의 경도를 측정하여 평균값을 구하고 비교하였다. 부식 저항성 시험을 위해 직사각형 형태의 TiNC와 SSC의 원재료(금속관으로 가공되기 전 판상 형태)를 준비하였다. 각 금속관 종류 당 2회의 부식 시험을 시행하였다. 부식 용액에 용출된 금속 이온의 총 양을 유도결합 플라즈마 분광분석기로 측정하였다. 5개의 TiNCs로 반복적으로 가해지는 칫솔력에 대한 색조 안정성 시험을 시행하였다. TiNCs의 평균 경도는 SSCs의 평균 경도보다 유의미하게 높았다. TiNCs와 SSCs의 원재료로부터 용출된 금속 이온의 총 합은 ISO 22674(재료의 무결성에 관한 기준) 기준치를 넘지 않음을 확인했다. TiNCs의 금색 코팅은 반복적인 물리적 자극에 대하여 주어진 시간 동안 안정성을 가졌다.

스트레처블 기판상에 산화물 기반의 광센서 제작 (Fabrication of an Oxide-based Optical Sensor on a Stretchable Substrate)

  • 김무진
    • 산업융합연구
    • /
    • 제20권12호
    • /
    • pp.79-85
    • /
    • 2022
  • 최근 전자소자는 플렉서블 기판상에 제작된 스마트폰이 출시되었으며, 스트레처블 한 전자소자의 연구가 진행되고 있다. 본 논문에서는 실리콘 기반의 스트레처블한 소재를 만들어 이것을 기판으로 사용하여 산화물을 이용한 광센서 소자를 구현하여 평가하고자 한다. 이를 위해, 실리콘 기반의 용액성 고무를 이용하여 상온에서 잘 늘어나는 기판을 만들어 소재의 350% 연신율을 확인하였으며, 반사도, 투과도, 흡수도와 같은 광특성을 측정하였다. 다음으로 이러한 소재는 표면이 소수성을 나타내기 때문에 표면 세정 및 친수성으로 변화시키기 위하여 산소 기반의 플라즈마 표면 처리를 진행하였으며, 진공장비로 AZO(Aluminium Zinc Oxide) 기반의 산화막을 증착한 후 면봉을 이용하거나 메탈 마스트로 Ag 전극을 형성시켜 광센서를 완성하였다. 제작된 광전자소자는 빛을 조사했을 때와 하지 않았을 때의 전압에 따른 전류 변화를 분석하여 광에 의하여 생성된 캐리어들에 의한 광전류를 관찰하였으며, 벤딩 장비를 이용하여 폴딩에 따른 광센서소자 영향성을 추가 테스트하였다. 벤딩 테스트 전과 빛에 의해 생성되는 전류값 변화를 추가로 분석하였다. 향후 스트레처블 기판위에 늘어나는 반도체 물질 및 전극을 형성하여 폴딩(벤딩) 및 늘어나는 광소자를 집중적으로 연구할 계획이다.

저온 Cu 하이브리드 본딩을 위한 SiCN의 본딩 특성 리뷰 (A Review on the Bonding Characteristics of SiCN for Low-temperature Cu Hybrid Bonding)

  • 김연주;박상우;정민성;김지훈;박종경
    • 마이크로전자및패키징학회지
    • /
    • 제30권4호
    • /
    • pp.8-16
    • /
    • 2023
  • 디바이스 소형화의 한계에 다다르면서, 이를 극복할 수 있는 방안으로 차세대 패키징 기술의 중요성이 부각되고 있다. 병목 현상을 해결하기 위해 2.5D 및 3D 인터커넥트 피치의 필요성이 커지고 있는데, 이는 신호 지연을 최소화 할 수 있도록 크기가 작고, 전력 소모가 적으며, 많은 I/O를 가져야 하는 등의 요구 사항을 충족해야 한다. 기존 솔더 범프의 경우 미세화 한계와 고온 공정에서 녹는 등의 신뢰성 문제가 있어, 하이브리드 본딩 기술이 대안책으로 주목받고 있으며 최근 Cu/SiO2 구조의 문제점을 개선하고자 SiCN에 대한 연구 또한 활발히 진행되고 있다. 해당 논문에서는 Cu/SiO2 구조 대비 Cu/SiCN이 가지는 이점을 전구체, 증착 온도 및 기판 온도, 증착 방식, 그리고 사용 가스 등 다양한 증착 조건에 따른 SiCN 필름의 특성 변화 관점에서 소개한다. 또한, SiCN-SiCN 본딩의 핵심 메커니즘인 Dangling bond와 OH 그룹의 작용, 그리고 플라즈마 표면 처리 효과에 대해 설명함으로써 SiO2와의 차이점에 대해 기술한다. 이를 통해, 궁극적으로 Cu/SiCN 하이브리드 본딩 구조 적용 시 얻을 수 있는 이점에 대해 제시하고자 한다.

청정 수소 저장을 위한 고효율, 저탄소 배출 암모니아 합성기술 동향 (Advancements in High-Efficiency Ammonia Synthesis Technology: A Key Solution for Green Hydrogen Storage in the Carbon-Neutral Era)

  • 정원준;김진태;조강희
    • 청정기술
    • /
    • 제30권2호
    • /
    • pp.71-93
    • /
    • 2024
  • 최근, 무탄소 에너지원(특히, 선박 및 혼소 발전), 고효율 청정 수소 저장 및 매개체로써 암모니아가 다시 각광받고 있다. 암모니아는 화학공학에서 매우 중요한 공정 중 하나인 Haber-Bosch 공정을 통해 합성할 수 있지만, 이 공정은 에너지 소비량이 높고 탄소 배출량 역시 높아, 기존 공정을 통해 암모니아를 합성할 시 탄소 저감 효과가 미미하다. 이러한 기존 공정의 치명적인 단점을 해결하기 위해 최근, 높은 에너지 효율로 탄소 배출이 적게 암모니아를 합성할 수 있는 열화학적 합성 방법이 많이 개발되고 있다. 소재측면에서는 기존 공정보다 완화된 공정 조건에서도 충분히 높은 암모니아 합성 성능을 보일 수 있는 고성능 촉매 소재를 개발하는 연구가 진행되고 있으며, 공정측면에서는 매체 순환식(chemical-looping) 합성 방법, 플라즈마 합성방법, 기계화학적 합성 방식 등 다양하게 적용되고 있다. 이번 총설에서는 최근 청정수소 저장을 효과적으로 저장하기 위해 어떤 암모니아 합성 기술들이 개발되고 있는지 자세히 소개하고자 한다.