• Title/Summary/Keyword: Solid-Gas Reaction

Search Result 270, Processing Time 0.029 seconds

Preparation of Pure CO2 Standard Gas from Calcium Carbonate for Stable Isotope Analysis (탄산칼슘을 이용한 이산화탄소 안정동위원소 표준시료 제작에 대한 연구)

  • Park, Mi-Kyung;Park, Sunyoung;Kang, Dong-Jin;Li, Shanlan;Kim, Jae-Yeon;Jo, Chun Ok;Kim, Jooil;Kim, Kyung-Ryul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.1
    • /
    • pp.40-46
    • /
    • 2013
  • The isotope ratios of $^{13}C/^{12}C$ and $^{18}O/^{16}O$ for a sample in a mass spectrometer are measured relative to those of a pure $CO_2$ reference gas (i.e., laboratory working standard). Thus, the calibration of a laboratory working standard gas to the international isotope scales (Pee Dee Belemnite (PDB) for ${\delta}^{13}C$ and Vienna Standard Mean Ocean Water (V-SMOW) for ${\delta}^{18}O$) is essential for comparisons between data sets obtained by other groups on other mass spectrometers. However, one often finds difficulties in getting well-calibrated standard gases, because of their production time and high price. Additional difficulty is that fractionation processes can occur inside the gas cylinder most likely due to pressure drop in long-term use. Therefore, studies on laboratory production of pure $CO_2$ isotope standard gas from stable solid calcium carbonate standard materials, have been performed. For this study, we propose a method to extract pure $CO_2$ gas without isotope fractionation from a solid calcium carbonate material. The method is similar to that suggested by Coplen et al., (1983), but is better optimized particularly to make a large amount of pure $CO_2$ gas from calcium carbonate material. The $CaCO_3$ releases $CO_2$ in reaction with 100% pure phosphoric acid at $25^{\circ}C$ in a custom designed, evacuated reaction vessel. Here we introduce optimal procedure, reaction conditions, and samples/reactants size for calcium carbonate-phosphoric acid reaction and also provide the details for extracting, purifying and collecting $CO_2$ gas out of the reaction vessel. The measurements for ${\delta}^{18}O$ and ${\delta}^{13}C$ of $CO_2$ were performed at Seoul National University using a stable isotope ratio mass spectrometer (VG Isotech, SIRA Series II) operated in dual-inlet mode. The entire analysis precisions for ${\delta}^{18}O$ and ${\delta}^{13}C$ were evaluated based on the standard deviations of multiple measurements on 15 separate samples of purified $CO_2$. The pure $CO_2$ samples were taken from 100-mg aliquots of a solid calcium carbonate (Solenhofen-ori $CaCO_3$) during 8-day experimental period. The multiple measurements yielded the $1{\sigma}$ precisions of ${\pm}0.01$‰ for ${\delta}^{13}C$ and ${\pm}0.05$‰ for ${\delta}^{18}O$, comparable to the internal instrumental precisions of SIRA. Therefore, we conclude the method proposed in this study can serve as a way to produce an accurate secondary and/or laboratory $CO_2$ standard gas. We hope this study helps resolve difficulties in placing a laboratory working standard onto the international isotope scales and does make accurate comparisons with other data sets from other groups.

Synthesis of Titanium Diboride and Composites by Carbothermic Reduction of Titanium Oxide and Boric Oxide

  • Yoon, Su-Jong;Jha, Animesh
    • The Korean Journal of Ceramics
    • /
    • v.4 no.4
    • /
    • pp.387-393
    • /
    • 1998
  • The formation of titanium diboride ($TiB_2$ ) via the reduction of $TiO_2$ with boric oxide and carbon was studied in a partially reducing atmosphere of argon mixed with 4 vol.%H2. The effect of reaction time, temperature, partial pressure of nitrogen and $TiO_2/B_2_O3$ stoichiometric ratio on the reducibility of oxides has been studied. The phases formed were analysed by using X-ray rowder diffraction and scanning sosctron microscopic techniques. In this paper, we also investigated the presence of $CaC_2$ as a reducing agent on the reducibility of oxide mixtures and on the Ti-B-C-Ca-O phase equilibria. The morphology of $TiB_2$ formed in the presence of $CaC_2$ is compared with the microstructure of $TiB_2$ formed as a consequence of carbothermic reduction. The observed variation in $TiB_2$ crystals formed is also explained.

  • PDF

CO2 Decomposition Characteristics of Zn-ferrite Powder Prepared by Hydrothermal and Solid State Reaction (수열합성법과 고상법을 이용해 제조된 Zn-ferrite 분말의 이산화탄소 분해 특성)

  • Nam, Sung Chan;Park, Sung Youl;Yoon, Yeo Il;Jeong, Soon Kwan
    • Applied Chemistry for Engineering
    • /
    • v.22 no.5
    • /
    • pp.555-561
    • /
    • 2011
  • The objective of this study is the development of carbon recycle technology which converts $CO_2$ captured from flue gas to CO or carbon and reuse in industrial fields. Since $CO_2$ is very stable and difficult to decompose, metal oxide was used as an activation agent for the decomposition of $CO_2$ at low temperature. Metal oxides which convert $CO_2$ to CO or carbon at $500^{\circ}C$ were prepared using Zn-ferrite by the solid state reaction and hydrothermal synthesis. The behaviors of $CO_2$ decomposition were studied using temperature programmed reduction/oxidation (TPR/TPO) and thermogravimetric analyzer (TGA). Zn-ferrite containing 5 wt% ZnO showed the largest reduction and oxidation. Reduction by $H_2$ was 26.53 wt%, oxidation by $CO_2$ was 25.73 wt% and 96.98% of adsorbed $CO_2$ was decomposed to $CO_2$ and carbon with excellent oxidation-reduction behaviors.

Ducted Rocket Propulsion System Development Proposal (Ducted Rocket의 현황과 추진기관 개발방안)

  • Lee Jun-Ho;Choi Sung-Han;Hwang Jong-Sun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.475-478
    • /
    • 2005
  • Ducted rocket produces thrust by 2 steps, primary incomplete combustion in the gas generator, and secondary complete combustion reaction in combustion chamber mixed by air taken through duct. the range of a rocket is determined by the weight of propellant, especially the weight of fuel. So ducted rocket has more efficiency and high terminal speed compared to traditional solid rocket motor. This propulsion system expected to be applied to various kinds of missile for anti-aircraft, anti-ship

  • PDF

Methane carbon dioxide reforming for hydrogen production in a compact reformer - a modeling study

  • Ni, Meng
    • Advances in Energy Research
    • /
    • v.1 no.1
    • /
    • pp.53-78
    • /
    • 2013
  • Methane carbon dioxide reforming (MCDR) is a promising way of utilizing greenhouse gas for hydrogen-rich fuel production. Compared with other types of reactors, Compact Reformers (CRs) are efficient for fuel processing. In a CR, a thin solid plate is placed between two porous catalyst layers to enable efficient heat transfer between the two catalyst layers. In this study, the physical and chemical processes of MCDR in a CR are studied numerically with a 2D numerical model. The model considers the multi-component gas transport and heat transfer in the fuel channel and the porous catalyst layer, and the MCDR reaction kinetics in the catalyst layer. The finite volume method (FVM) is used for discretizing the governing equations. The SIMPLEC algorithm is used to couple the pressure and the velocity. Parametrical simulations are conducted to analyze in detail the effects of various operating/structural parameters on the fuel processing behavior.

Characteristics of Organic Gas Sensitivity in Polymer LB Films (고분자 LB막의 유기 가스 감지 특성)

  • 신훈규;최용성;권영수;장상목;이범종
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.11a
    • /
    • pp.109-111
    • /
    • 1993
  • We reported the fabrication and thermal cross-linking of the LB files on porous substrates. The monolayers of the polymers which polyion-conplexed with PAA at the air-water interface can be transferred onto solid substrates such as porous fluorocarbon membrane filter and quartz crystal microbalance. The properties of the monolayers and the LB films investigated by $\pi$-A isothem, FT-IR, and SEM will be discussed. In addition, it was attempted to investigate the reaction of polymer LB films in the organic gas surrounding by the use of LB technique.

  • PDF

A Study on the Optimization of Microwave System for the Preparation of Activated Carbon

  • Kim, Dong-Sik;Park, Hwa-Chun;Byeon, Kyeong-Hwa
    • Carbon letters
    • /
    • v.3 no.4
    • /
    • pp.205-209
    • /
    • 2002
  • In the reaction of gas-solid phases, the microwave energy plays a role as a catalyst, because it causes friction between adjacent molecules and enables an unique characteristics of interior heating of the materials. When the dipole gases are adsorbed inside of the pore of carbon materials, the gases are decomposed by the microwave energy and reacted with the carbon atoms. Using this principle, we could make the activated carbon from coconut shell within 20 minute, and this residence time for activation is about 1/16 of rotary kiln. The BET surface area of activated carbon made by microwave is about $1,100m^2/g$ similar to conventional method of rotary kiln. In this study, the power of microwave generator was 400~1000W, and the gas for activation was steam mainly.

  • PDF

Asymptotic analysis of ignition of a semi-infinite body for a large activation energy (활성화 에너지가 매우 큰 경우에 점근법을 이용한 반무한체의 점화에 관한 연구)

  • 백승욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.4
    • /
    • pp.703-707
    • /
    • 1989
  • The ignition of solid particle under strong convective heating has been investigated by applying an asymptotic analysis to a semi-infinite body for varying values of gas recovery temperature and convective heat transfer coefficient. It was found that if the scale of the reaction zone is much smaller than the characteristic length of the body size, then infinite body theory can be used to estimate the ignition delay time. Furthermore, the convective heat transfer coefficient was found to have more influence on predicting the ignition delay times of particle exposed to an incident shock wave rather than the gas recovery temperature.

COMBUSTION TOXICITY ANALYSIS: ADVANCES USING A SPECIALIZED SAMPLING TECHNIQUE FOR FOURIER TRANSFORM INFRARED (FTIR) ANALYSIS

  • Talandis, Jonas;Innes, J.D.;Cox, A.W.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.178-184
    • /
    • 1997
  • The cone calorimeter as defined by ISO 5660, ASTM 1354, and NFPA 264A is used to assess the reaction to fire of almost any material that must be evaluated in the fire science field. Typical combustion gas analyses include oxygen, CO and CO2. Oxygen consumption is used to determine rate of heat release. Analysis of combustion gases other than oxygen, CO and CO2 has been attempted using filters to remove the solid smoke particles before analysis. This method has generated unreliable results due to the adsorption of many gas components on the active carbon . particles deposited on the filters. A technique using fourier Transform Infrared (FTIB) analysis without filtration will be disclosed and a discussion will be presented of the analytical results of toxic gases produced from various flame retarded polymeric materials. Use of such data in lethal toxic potency determinations is also reviewed.

  • PDF

Quantification of Three Prohibited Anabolic-Androgenic Steroids in Equine Urine using Gas Chromatography-Tandem Mass Spectrometry

  • Young Beom Kwak;Shaheed Ur Rehman;Hye Hyun, Yoo
    • Mass Spectrometry Letters
    • /
    • v.14 no.3
    • /
    • pp.104-109
    • /
    • 2023
  • Anabolic-androgenic steroids (AAS) are used illegally to enhance muscle development and increase strength and power. In this study, a reliable, and sensitive quantitative method was developed and validated using heptafluorobutyric acid anhydride (HFPA) derivatives for the simultaneous detection of prohibited AAS (testosterone [TS], boldenone [BD], 5α-estrane-3β,17α-diol [EAD]) using gas chromatography-tandem mass spectrometry (GC-MS/MS). For processing the samples, solid phase extraction, methanolic hydrolysis, and liquid-liquid extraction were used. For detection using mass spectrometry, the multiple reaction monitoring (MRM) mode was used with the electron ionization (EI) positive mode. The method was evaluated for selectivity, linearity, lower limit of quantification, intra- and inter-day precision, accuracy, and stability. The results showed that the method was accurate and reproducible for the quantitation of the three steroids. The developed method was finally applied to the analysis of a suspect gelding urine sample received from the Asian Quality Assurance Program (AQAP).