• Title/Summary/Keyword: Solid environmental samples

Search Result 243, Processing Time 0.028 seconds

Risk assessment and distribution characteristics of N-nitrosamines in drinking water treatment plants (나이트로사민류의 국내 정수장 분포 특성 및 위해성 평가)

  • Son, Boyoung;Lee, Leenae;Yang, Mihee;Park, Sangmin;Pyo, Heesoo;Lee, Wonsuk;Park, Juhyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.389-398
    • /
    • 2018
  • A nationwide survey of 8 N-nitrosamines in finished water samples from drinking water treatment plants (DWTPs) in Korea was conducted. The samples were pre-treated by solid-phase extraction (SPE) and analyzed using a gas chromatography coupled with tandem mass spectrometry (GC-MS/MS). According to the study results, four N-nitrosamines (NDMA, NDEA, NMOR, NDBA) were detected for three consecutive years, NMEA and NPYR were only found in samples collected in 2013. Two of these N-nitrosamines, N-nitrosodimethylamine (NDMA) and N-nitrosodiethylamine (NDEA), have received attention and were the most commonly detected. The concentration of NDMA and NDEA in this study ranged from $0.002{\mu}g/L$ to $0.013{\mu}g/L$ and in $0.001{\mu}g/L$ to $0.008{\mu}g/L$, respectively. In comparison to studies performed in EPA(UCMR2), the concentrations of NDMA (from $0.002{\mu}g/L$ to $0.630{\mu}g/L$) and NDEA (from $0.005{\mu}g/L$ to $0.100{\mu}g/L$) observed in the this study were low.

Assessment of TOC Analysis Method for Livestock Manure including High Strength Solid Organics (고농도 고형 유기물질을 포함하는 가축 분뇨의 TOC 분석방법 평가)

  • Lee, Yunhee;Oa, Seong-Wook;Kim, Yongseok;Park, Jihyung
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.512-516
    • /
    • 2014
  • Two different methods for TOC (Total Organic Carbon) analysis of livestock manure including high strength solid organics were evaluated. Firstly, an analyzing method by dilution after pre-treated by Ultrasonicator and 100 mesh sieve for homogenization was defined as TOC 1; and secondly method divided by particulate organic carbon (POC) and dissolved organic carbon (DOC) was defined as TOC 2. 116 samples collected from 56 farms were analyzed in TOC1, TOC2, BOD and VSS. TOC1 method showed higher accuracy at less than 30,000 mg/L of TOC while TOC2 method presented significant reliability at over that concentration. Regarding to the sample with the same VSS concentration, the correlation between TOC 2 and VSS (${\rho}$: 0.806) was slightly higher than that between TOC 1 and VSS (${\rho}$: 0.784), resulted from a relatively low loss of solids and a low error probability (dilution and homogenization effects) in the analyzing procedures. In addition, the reliability between POC and VSS in TOC2 was high and the POC was about 4.4 fold that of the VSS. Consequently, TOC 2 without dilution effect was assessed as a proper method to increase the analyzing accuracy of swine manure including high solid organics.

Biological Evaluation for Characteristics of Leachate Toxicity from Municipal Solid Waste Landfill (생물학적 방법에 의한 도시생활폐기물 매립지의 침출수 독성특성 평가)

  • 황인영;류경무
    • Environmental Analysis Health and Toxicology
    • /
    • v.11 no.1_2
    • /
    • pp.31-39
    • /
    • 1996
  • Leachate from municipal solid waste (MSW) landfill, effluent from leachate treatment plant, and ground water sample from a monitoring well near landfill site were tested for an acute toxicity. Microtox toxicity test was used for testing the acute toxicity of leachate and other samples. EC$_{50}$ values which a concentration of pollutant for reducing 50% light output from luminescent bacteria, Photobacterium phosphoreum were determined to assess the toxicity of pollutants as well as the relative toxicity. In addition, characteristics of leachate were studied and compared to those of phenol and pentachlorophenol (PCP) which are typical aquatic toxic pollutants. For leachate, EC$_{50}$ for 30 min incubation was 10.8%, while for phenol and PCP, 46 ppm and 1.2 ppm, respectively. the relative toxicity of treated leachate by in situ aeration with activated sludge was reduced to more than 75% of toxicity of the untreated leachate. Microtox toxicity test was failed to figure out EC$_{50}$ values for groundwater from a monitoring well since the relative toxicity of the unconcentrated sample was too low to estimate EC$_{50}$. Addition of activated carbon to leachate was reduced the relative toxicity. The reduction Pattern of the relative toxicity of leachate by mechanical aeration was similar to that of PCP, but different from that of phenol. These findings suggest that the toxicity of leachate may come from PCP-like toxic compounds rather than phenol-like one. In conclusion, the process of aeration with activated sludge might be very important to reduce the environmental toxicity of leachate. And Microtox test could be a reasonable bioassay for screening and monitoring the environmental toxicity of leachate from municipal solid waste landfill as well as for determining the reduction efficiency of the leachate toxicity by various treatment processes in leachate treatment plant.

  • PDF

A Microbiological Study on the Frozen Beef and Pork in Seoul Area (서울시 일부지역 冷凍牛肉 및 豚肉의 細菌學的 調査硏究)

  • Shin, Kyoung-Ho;Lee, Yong-Wook
    • Journal of Environmental Health Sciences
    • /
    • v.13 no.2
    • /
    • pp.65-74
    • /
    • 1987
  • This study was carried out to investigate the bacterial contamination of retailed beef and pork in Seoul area. For this study 44 samples were collected at butcheries and department stores from March to April, 1987 and were examined on the following items. 1. Comparison of bacterial contamination between butcheries and department stores. 2. Degree of bacterial enumeration by repair method of injured microorganisms in the frozen beef and pork. 3. Degree of bacterial contamination in the frozen beef and pork. As the result of this study, the following conclusions were obtained. 1. Difference of bacterial contamination between butcheries and department stores was not significant. 2. Enumeration of total bacterial count by solid repair procedure resulted in about 1.5-fold increase in beef and about 1.8-fold increase in port. 3. Enumeration of total coliform count by liquid repair procedure resulted in about 32.1-fold increase in beef and about 12.0-fold in pork. 4. Salmonella species were not detected, but Staphylococcus species were detected 8 cases (18.2%) in beef, 7 cases (15.9%) in pork. 5. In total bacterial count, all beef samples were lower than 10$^6$/g, but 2 pork samples were higher than 10$^6$/g. 6. The ratio of total coliform count to total bacterial count was 0.07 in beef, 0.05 in pork by standard method and 0.48 in beef, 0.25 in pork by repair method.

  • PDF

Assessment of Groundwater Quality for Irrigation and Agro-based Industrial Usage in Selected Aquifers of Bangladesh

  • Rahman, Md. Mokhlesur;Hoque, Syed Munerul;Jesmin, Sabina;Rahman, Md. Siddiqur;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.2
    • /
    • pp.98-105
    • /
    • 2005
  • Groundwater sampled from 24 tube wells of three districts namely Sherpur, Gaibandha and Naogaon in Bangladesh was appraised for their water quality for irrigation and agro-based industrial usage. All waters under test were slightly alkaline to alkaline (pH = 7.2 to 8.4) in nature and were not problematic for crop production. As total dissolved solid (TDS), all groundwater samples were classified as fresh water (TDS<1,000 mg/L) in quality. Electrical conductivity (EC) and sodium adsorption ratio (SAR) values reflected that waters under test were under medium salinity (C2), high salinity (C3) and also low alkalinity (S1) hazard classes expressed as C2S1 and C3S1. As regards to EC and soluble sodium percentage (SSP), groundwater samples were graded as good and permissible in category based on soil properties and crop growth. All water samples were free from residual sodium carbonate (RSC) and belonged to suitable in category. Water samples were under soft moderately hard, hard and very hard classes. Manganese, bicarbonate and nitrate ions were considered as major pollutants in some water samples and might pose threat in soil ecosystem for long-term irrigation. For most of the agro-based industrial usage, Fe and Cl were considered as troublesome ions. On the basis of TDS and hardness, groundwater samples were not suitable for specific industry. Some water samples were found suitable for specific industry but none of these waters were suitable for all industries. The relationship between water quality parameters and major ions was established. The correlation between major ionic constituents like Ca, Mg, K, Na, $HCO_3$ and Cl differed significantly. Dominant synergistic relationships were observed between EC-TDS, SAR-SSP, EC-Hardness, TDS-Hardness and RSC-Hardness.

Determinant Factors for Blood VOCs Exposures in College Students (대학생들의 혈액 내 휘발성 유기화합물 노출에 영향을 미치는 요인)

  • Choi, Jeong Mi;Kim, Min Su;Shin, Won Ho;Moon, Chan-Seok
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.1
    • /
    • pp.24-29
    • /
    • 2015
  • Objectives: The objective of this study was to identify determine factors for blood VOCs levels in college students. Methods: Venous blood samples were collected from healthy 29 male and 25 female volunteers. The samples were analyzed with solid-phase microextraction gas chromatography and mass spectrometry. Results: Blood concentrations of benzene, toluene, ethylbenzene, m-,p-xylene, o-xylene were higher in smoking group than in non-smoking group. Geometric means of smoking group and non-smoking group were 0.45 and $0.36{\mu}g/L$ in benzene, 0.82 and $0.47{\mu}g/L$ in toluene, 0.44 and $0.41{\mu}g/L$ in ethylbenzene, 0.49 and $0.39{\mu}g/L$ in m-,p-xylene and 0.47 and $0.43{\mu}g/L$ in o-xylene, respectively. Gender, alcohol drinking, coffee, commuting time (30 minutes) by a car and adjacency between home and road were not associated with increasing blood VOCs concentrations of college students. Conclusion: Smoking habit was significantly associated with blood concentrations of benzene, toluene, ethylbenzene, o-,m-,p-xylene in college students.

Application and Optimization of the IsoButoxycarbonyl Derivatization method to the Analysis of Trace Level Phenols in Environmental Samples (환경시료로부터 미량 페놀류의 분석을 위한 isoButoxycarbonyl 유도체화 분석방법 적용 및 최적화)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.1
    • /
    • pp.37-51
    • /
    • 2002
  • Eleven phenols including two chlorophenols, eight alkylphenols and bisphenol A were derivatized with isobutylchloroformate to form their isobutoxycarbonyl derivatives. Standard phenol mixture was concentrated for the isobutoxycarbonyl (isoBOC) derivatization and analysed by gas chromatography/mass spectrometry (GC/MS). The recoveries of the derivatization method of alkylphenols, chlorophenols, and bisphenol A were calculated by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison; shaking and heating method. The linear detector responses were obtained in the concentration range of 5∼400 ng, with correlation coefficients varying from 0.9755∼0.9981. Recoveries of the alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison ; the US-EPA method and the isoBOC derivatization method, Eleven phenols in water samples were extracted with dichloromethane and then concentrated. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1∼109.9% and 90.3∼126.6% for the US-EPA method and the isoBOC.

Effectiveness of Settling Treatment System to Reduce Urban Nonpoint Source Pollutant Load by First Flush (초기 강우에 의한 도시 유역 비점오염 부하의 유입 저감을 위한 침강 처리 시설 적용 타당성 분석)

  • Kim, Jaeyoung;Seo, Dongil;Lee, Tongeun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.140-148
    • /
    • 2017
  • The effectiveness of the first flush treatment system using settling process was evaluated to reduce urban nonpoint source pollutant loads to surface water during storm events. A pilot scale system was constructed and tested in the field and surface runoff samples were collected automatically according to pre-defined conditions. Nine rainfall events were tested and average removal efficiencies of TSS (Total Suspended Solid), TP (Total Phosphorus) and TN (Total Nitrogen) were evaluated as 87.4%, 75.3%, and 43.6%, respectively. Concentration and removal efficiency of pollutants were found to be affected by an amount of rainfall and rainfall intensities of the respective events. This seemed to be caused by the greater particulate fractions of first flushed samples than the samples collected in later time periods during the same rainfall events. The study showed that it is possible to remove a significant portion of the nonpoint source pollutant loads in initial rainfall runoff by using a simple settling process for TSS and TP without requiring additional power or chemicals.

Simultaneous determination of 37 volatile organic compounds at ng/L concentration level in surface water by HS-SPME-GC/MS (HS-SPME-GC/MS에 의한 지표수에서 ng/L 농도 수준의 37개 휘발성유기화합물의 동시 분석)

  • Kim, Tae-Seung;Hong, Suk-Young;Kim, Jong-Eun;Lim, Hyun-Hee;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.39-49
    • /
    • 2012
  • A method to detect 37 volatile organic compounds (VOCs) in surface water was described based on headspace solid-phase micro extraction and gas chromatography-mass spectrometry. VOCs in water were vaporized for 30 min at 40 $^{\circ}C$ in a headspace vial and adsorbed on 85 ${\mu}m$ carboxen-polydimethylsiloxane. Under the established condition, the lowest quantification limit was 4.1-96 ng/L by using 4.0 mL water sample, and the relative standard deviation was less than 15% at concentrations of 0.05 and 0.50 ${\mu}g/L$. The detection limits meet lower concentration than 1/10 of the water quality criteria for VOCs established by the US EPA or Germany. The LOQ is a sensitivity which the monitoring for the establishing water quality criteria requires. When the proposed method was used to analyze the target compounds in sixteen surface water samples and total 16 VOCs were detected in surface water samples collected from Gum-River. Maximum concentrations of VOCs detected were not exceeded the EPA or Germany guidelines in any of the samples.

Characteristics of Stabilization of Excavated Solid Wastes by Aerobic and Anaerobic Landfilling (호기 및 혐기매립에 의한 굴착폐기물의 안정화 특성 연구)

  • Park, Jin-Kyu;Oh, Dong Ik;Lee, Nam-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.3
    • /
    • pp.76-85
    • /
    • 2004
  • Anaerobic decomposition of municipal solid waste (MSW) had potential adverse impacts such as the production of methane and long-term post closure on human health and the environment. It was demonstrated that aerobic degradation of MSW resulted in the reduction of a methane yield and the enhancement of stabilization of MSW. Excavated solid wastes were both aerobically and anaerobically treated in order to evaluate the effects of air injection on the stabilization of landfill site. The municipal solid waste (MSW) samples were excavated from a 10-year old landfill (operation period: 1991. 11~1994. 11), Jeonju, Korea. Excavated municipal solid wastes are primarily composed of soils and vinyl/plastics. For the two aerobic simulated lysimeters, the levels of $O_2$ ranged 1.6~23.1% and the levels of $CO_2$ ranged 1.5~15.1%, which confirmed the aerobic decomposition. Aeration did prevent methane formation. For the anaerobic simulated lysimeter, the $CO_2$ rose as $O_2$ was consumed and low levels of CH4 were produced. The pH levels ranged from 7.7 to 8.9 for anaerobic lysimeter and from 7.3 to 8.5 for aerobic lysimeters. As expected, aerobic treatment proved to enhance the removal of biodegradable materials in the excavated solid wastes when monitoring the concentration of BOD, COD, $NH_4-N$, and $NO_3-N$ in the leachate.

  • PDF