• Title/Summary/Keyword: Solar module

Search Result 737, Processing Time 0.029 seconds

The Study on the Long-term Reliability Characteristics of Ribbon Joint: Solar Cell Ribbon Thickness and Solder Compositions (태양전지 Ribbon 두께와 조성에 따른 Ribbon접합부의 장기 신뢰성 특성에 관한 연구)

  • Jeon, Yu-Jae;Kang, Min-Soo;So, Kyung-Jun;Lee, Jae-June;Shin, Young-Eui
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.88-94
    • /
    • 2014
  • In this paper, Thermal Shock tests were performed varying the composition of the solder and ribbon thickness (A-type:0.2mm/60Sn40Pb, B-type:0.25mm/60Sn40Pb, C-type:0.2 /62Sn36Ag2Pb, D-type:0.25mm/62Sn36Ag2Pb) for evaluating the long-term reliability about Ribbon junction of Silicon solar cells. Thermal Shock test condition was performed during the 600cycles having $-40^{\circ}C{\sim}85^{\circ}C$ temperature range each 15 minutes; One cycle time was 30min. As a result, the initial efficiency of the A-type, B-type, and C, D-type were showed 15.0%, 15.4% and 15.8% respectively. After thermal shock test, the efficiency decreasing-rate of each type were as follow that A-type was 13.8%, B-Type was 15.4%. C-Type and D-Type was 15.3% and 16.2%, respectively. Also, degradation of surface changes and I-V characteristic curves were showed that the series resistance of the A, C-type was increased. Also, current lowering starting point of C-type shown 0.05volt[v] earlier than that of A-type. And B, D-type shown characteristics of composite lowering efficiency such as increase of series resistance, decrease of parallel resistance and cell damage. Therefore Initial solderability and efficiency of specimens using the solder with SnAgPb were superior. But, It has inferior the long-term reliability. The test was confirmed that as the ribbon thickness increases, long-term reliability of solar cell will decrease.

Monitoring of Mythimna separata Adults by Using a Remote-sensing Sex Pheromone Trap (원격감지 성페로몬트랩을 이용한 멸강나방(Mythimna separata) 성충 예찰)

  • Jung, Jin Kyo;Seo, Bo Yoon;Cho, Jum Rae;Kim, Yong
    • Korean journal of applied entomology
    • /
    • v.52 no.4
    • /
    • pp.341-348
    • /
    • 2013
  • We desinged and evaluated a remote-sensing sex pheromone trap for real-time monitoring of Mythimna separata (Lepidoptera: Noctuidae), a migratory insect in Korea. The system consisted of a modified cone-trap with a sex pheromone lure, a sensing module based on light interruption, a signal transmission module based on code division multiple access, a main electronic board for system control, a power supply based on a solar collector, a stainless steel-pole supporting the system, and a signal collection and display system based on an internet web page. The ratio (>92%) of the actual number of insects to the signal number in the remote-sensing trap was improved by sensing only within a limited period at night on the basis of the insect's circadian rhythm, control of signal sensitivity on the basis of sensing software programming, 1-h interval for signal transmission, and adjustment of the signal transmission program. The signal occurrence pattern in the remote-sensing trap was conclusively similar (correlation coefficient, >0.98) to the actual pattern of adult occurrence in the trap. The result indicated that the remote-sensing trap based on the attraction of the sex pheromone lure for M. separata has a promising potential for practical use. Occurrence of M. separata adults was observed several times in 2011 and 2012, and the peaks were sharp.

A Study of Standardization of Detecting Abnormal Data by Front Weed's Shadow Effect in over 100 kW Photo Voltaic Power Generation Unit (100 kW 이상의 태양광 발전단위에서 전방 잡초 그림자 영향 분석에 의한 비정상 데이터 표준화 연구)

  • Kim, Hong Myeong;Lee, Yu Ri;Jung, Jae hak
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.416-423
    • /
    • 2020
  • Majority of over 100 kW capacity photo voltaic (PV) power generation system was constructed on the plate ground of soil. Rarely PV system installed on concrete or building but it usually be under 25 kW capacity. On the soil ground the weeds growen up and it's shadow influenced to decrease of amount of PV power generation. This work analysis the weeds shadow's effect to decrease of PV power generation with 100 kW capacity of real PV power generation system in Yeungnam University, Finally the weed shadow"s influence value through the real field monitoring Data is suggested for give a standard management time of weeds to avoid the negative influence on whole power plant. Moreover the hot spot which is generated by long term partial shallow on PV module also can detected with the result of this work. It also suggested as a standard value of monitoring Data.

Study on Remote control and monitoring system of the multipurpose guard rail using USN (USN을 이용한 다목적 가드레일의 원격제어 및 모니터링 시스템에 관한 연구)

  • Song, Je-Ho;Lee, In-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.7176-7181
    • /
    • 2015
  • This thesis is about the system where the solar module is attached to the high functional guardrail posts with anti-weed, anti-plant, and road-kill applied to produce internal power, enabling the integrated control and real-time monitoring of appearance of wildlife and road conditions using the USN. The whole system consists of a photovoltaic module(PV), a detection sensor(pyroelectric), a controller(operation select and motion sensor), the USN system, the DB(sound and flash), an output unit of sound and flash, and the control system of road-kill prevention and safety induction for vehicles. Thus this study aims to address the remote control and monitoring system of multipurpose guardrails to improve road environment, prevent road-kills, protect wild animals, and guide cars safely by using the USN which is combined with new renewable energy and IT convergence technology. As a result of the study on the remote control and monitoring system using the USN, it was ascertained that the response time of the unmanned sensing system was within 5.1 ms with the current consumption of 0.328 mA, and the data transmission speed of the remote control system was 250 kbps with the current consumption of 0.283 mA.

Status Diagnosis Algorithm for Optimizing Power Generation of PV Power Generation System due to PV Module and Inverter Failure, Leakage and Arc Occurrence (태양광 모듈, 인버터 고장, 누설 및 아크 발생에 따른 태양광발전시스템의 발전량 최적화를 위한 상태진단 알고리즘)

  • Yongho Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.4
    • /
    • pp.135-140
    • /
    • 2024
  • It is said that PV power generation systems have a long lifespan compared to other renewable energy sources and require little maintenance. However, there are cases where the performance expected during initial design is not achieved due to shading, temperature rise, mismatch, contamination/deterioration of PV modules, failure of inverter, leakage current, and arc generation. Therefore, in order to solve the problems of these systems, the power generation amount and operation status are investigated qualitatively, or the performance is comparatively analyzed based on the performance ratio (PR), which is the performance index of the solar power generation system. However, because it includes large losses, it is difficult to accurately determine whether there are any abnormalities such as performance degradation, failure, or defects in the PV power generation system using only the performance coefficient. In this paper, we studied a status diagnosis algorithm for shading, inverter failure, leakage, and arcing of PV modules to optimize the power generation of PV power generation systems according to changes in the surrounding environment. In addition, using the studied algorithm, we examined the results of an empirical test on condition diagnosis for each area and the resulting optimized operation of power generation.

Development of P.P.T CanSat System Applying Energy Harvesting System (에너지 하베스팅 시스템을 적용한 자가발전 P.P.T CanSat 시스템 개발)

  • Chae, Bong-Geon;Kim, Su-Hyeon;Kim, Hye-In;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.4
    • /
    • pp.315-323
    • /
    • 2018
  • CanSat has being attracted considerable attentions for the use as training purposes owing to its advantage that can implement overall system functions of typical commercial satellites within a small package like a beverage can. So-called P.P.T CanSat (Power Plant Trio Can Satellite), proposed in this study, is the name of a CanSat project which have participated in 2015 domestic CanSat competition. Its main objective is to self-power on a LED and a MEMS sensor module by using electrical energy harvested from solar, wind and piezo energy harvesting systems. This study describes the system design results, payload level function tests, flight test results and lessons learned from the flight tests.

Study on Optimization of Tilt Angle for Stationary Solar Voltaic Module (고정식 태양 집광판의 설치각도 최적화에 관한 연구)

  • Kim, Moonki;Kim, Daeyeong;Yun, Hongsun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.129-129
    • /
    • 2017
  • 태양광 발전으로 생산된 전력으로 냉방기나 난방기를 직접 구동하는 경우에 냉방을 위해서는 7,8,9월 집광량이 많아야 하고, 난방을 위해서는 12,1,2월에 집광량이 많아야 한다. 하지만 일반적으로 사용되는 집광판은 평판형의 고정식이 대부분으로 필요에 따라서 집광량을 변동시키는 것이 불가능하다. 따라서 전력부하가 가장 큰 시기에 집량광이 가장 많아지도록 설치되어야 한다. 본 연구에서는 최적의 집광판 설치조건을 구명하기 위하여 집광판의 설치 각도에 따른 년중 일사량을 예측하기 위한 모델을 개발하고 계산된 일사량과 기상청에서 실측한 일사량을 비교하였다. 분석 대상은 대전(북위 36도 22분)으로 하였다. 년간 최대 일사량을 확보할 수 있는 집광판 설치각은 $36^{\circ}$로 분석되었다. 반면에 월별로 최대 일사량을 확보하기 위한 집광판 설치각도는 1월에 $57^{\circ}$, 2월에 $48^{\circ}$, 3월에 $36^{\circ}$, 4월에 $24^{\circ}$, 5월에 $15^{\circ}$, 6월에 $12^{\circ}$, 7월에 $15^{\circ}$, 8월에 $24^{\circ}$, 9월에 $36^{\circ}$, 10월에 $45^{\circ}$, 11월에 $57^{\circ}$, 12월에 $60^{\circ}$로 예측되었다. 한편 냉방부하가 많은 6.7.8.9월에 최대 일사량을 확보하기 위한 집광판 설치각도는 $21^{\circ}$로 예측되었다. 이상의 결과로 볼 때 태양광 발전을 위한 집광판은 전력부하와 용처에 따라 적정한 설치각도를 결정하는 것이 중요한 것으로 판단되었고, 본 연구에서 개발된 예측모델이 이러한 작업에 유효하게 사용될 수 있을 것으로 판단되었다.

  • PDF

A Study on 6-pulse-shift Current-source PWM Inverter for Photovoltaic System (태양광발전을 위한 6-pulse-shift 전류형 인버터에 관한 연구)

  • Lim, Joung-Min;Lee, Sang-Hun;Park, Sung-Jun;Moon, Chae-Joo;Chang, Young-Hak;Lee, Man-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.193-200
    • /
    • 2006
  • This paper suggests a 6-pulse-shift converter structure with PWM current-source inverter based on buck-boost configuration to improve the efficiency and to reduce the switching frequency of inverter for photovoltaic generation system, the device can be operated as interface system between solar module system and power system grid without energy storage cell. The circuit has six current-source buck-boost converter which operate chopper part and kas one full bridge inverter which make a decision the polarity of AC output. Therefore, the proposed PWM power inverter has advantages such as the reduction of witching loss and realization of unity power factor operation. The theoretical backgrounds are discussed and the input-output characteristics for the implemented prototype inverter using TMS320F2812 are verified experimentally in this paper.

Short-range Monitoring of Marine AtoN Charge and Discharge Controller (해상용 항로표지 충·방전조절기의 근거리 모니터링)

  • Ye, Seong-Hyeon;Han, Soonhee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.933-939
    • /
    • 2015
  • If the Visual Aids(light wave signs) is not supplied the general power it is using solar power system. These power supply systems, the role of the charge/discharge control is very important. Introduction of IT(AIS etc.) for the effective management of the AtoN(Aids to Navigation) is a Visual Aids has been added to the device using the power to charge/discharge control, the need increases. The current charge/discharge controller is attached to the inside of the AtoN and checks on and verification of the maritime environment, depending on the difficulty. In order to resolve these issues in this paper, the Bluetooth module is mounted on the inside of the charge/discharge controller and proposed a possible system monitoring at close range. Advantage of the system implemented is a simple configuration and low installation cost. In addition, it can be applied to a variety of AtoN. Also, it has been able to check the real-time status information of the charge/discharge controller at a short distance in to reduce inspection costs, and reduce risk factors that might occur during check.

Magnetic Field Analysis for Development of Magnetic Torquer

  • Yim, Jo-Ryeong;Lee, Seon-ho;Rhee, Seung-Wu
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.63-63
    • /
    • 2003
  • There are many actuators and sensors used for attitude control system for KOMPSAT such as Reaction Wheel Assembly, Magnetic Torque Assembly, Dual Thruster Module, Solar array Drive, Three Axis Magnetometer, Conical Earth Sensor, Fine Sun Sensor Assembly, Coarse Sun Sensor Assembly, Gyro Reference Assembly and so on. For KOMPSA T satellite it has been considered using the Magnetic Torquer (MTQ) generating the magnetic dipole moment. In general, the magnetic dipole moment for satellite attitude control system is used for dumping out the excessive reaction wheel momentum so that the reaction wheel speed is not saturated. The objective of this study is to analyze the magnetic field characteristics generated by the Magnetic Torquer using the Maxwell 2D Field Simulator software. Currently, the developing model (DM) of the MTQ is being developed and manufactured at a company under the supervision of KARL MTQ is an electromagnet consisting of a ferromagnetic cylindrical core on which an excitation coil is wound. A current is passed through the coil to produce a dipole momentum in the ferromagnetic core. The configuration of the MTQ will be introduced in the presentation. The 2 dimensional model of the MTQ is drawn as axisymmetric models in RZ plane, and each corresponding material is assigned to the each MTQ object, the core, coil, and background. After the boundary conditions, current sources, and solution parameters are set up, the magnetic field intensities, directions, and other values specified by users can be calculated by using the finite element analysis. The theoretical magnetic field quantities obtained by the Maxwell 2D Simulator can be used for the basis of the development of the MTQ.

  • PDF