• Title/Summary/Keyword: Solar module

Search Result 737, Processing Time 0.027 seconds

A Basic Study on the Effect of the Wind Pressure according to Form on the Flat Roof mounted PV System (평지붕 PV거치 시스템의 형태에 따른 풍압영향에 관한 기초연구)

  • Yun, Doo-Young;Lee, Eung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.105-112
    • /
    • 2013
  • The new renewable energy became popular as a clean and sustainable alternative energy under the circumstances that the entire world is facing severe abnormal climate due to the use of fossil fuel, and among which, solar energy can be obtained anywhere and is not difficult to apply it into the existing buildings, which makes it possible to be widely distributed. However, as PV module is installed into a single plate system, it shows structural weaknesses which are vulnerable to wind load and give loss to design elements in external appearance. Accordingly, this study planned one-step parallel system to complement the problems occurring from a single plate system and used STAR-CCM+ V.8 made by CD-Adapco, a computational fluid dynamics(CFD) simulation tool to measure wind load stability and support based on the design standards for a single plate system and one-step parallel system. Building height was limited to less than 10m and wind speed was given when increasing from 35m/s to 50m/s by 5m/s on PV system installed into the flat roof. In this case, our analysis suggested that step-one parallel system was in class 7-9 according to Beaufort's wind power classification, which did not have an impact on the fixed PV system, and the single plate system is considered to cause risks in designing wind speed in central districts because it is more than wind power class 12.

Design and Analysis of Power System for Buoy (브이용 전력시스템 설계 및 분석)

  • Jo, Kwan-Jun;Yoo, Hee-Han;Gug, Seung-Gi;Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.31 no.3 s.119
    • /
    • pp.229-233
    • /
    • 2007
  • This paper presents the performance of PV(Photovoltaic) system, the design of MPPT(Maximum Power Point Tracker). Output of PV power system is DC, and PV power system is linked to the DC bus. The current(I)-voltage(V) output characteristic of PV cells changes with solar irradiance and cell temperature as parameters. As various PV modules respond differently to each of the parameters cited above. Maximum output of PV modules am be achieved by MPPT(Maximum Power Point Tracker) algorithm This paper includes a discussion on the performance of PV module, MPPT algorithm and the influence of PV module angle.

Analyzing the Possibility of the Building Integrated Photovoltaic with DSC by the Case Studies (사례연구를 통한 DSC에 의한 BIPV 가능성 분석 연구)

  • Lee, Eung-Jik
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.2
    • /
    • pp.54-63
    • /
    • 2017
  • The various colors and transparency of DSC and operability unrelated with directions greatly expand the use of BIPV, as a multi-functional composite of module. Therefore the possibility of DSC BIPV is examined by the case study and the analysis and then its applicability is examined. Most of the DSC BIPVs, which are found through a total of six case studies and analyzes in Korea and abroad, are mainly implemented with window glass and shading devices. This is related to the DSC transparency property. Improvements are due to the irritation of the eye due to the color of the red module. Therefore, it is important to take into account the color of the BIPV window depending on the use of the building and the room. Meanwhile, some colors of application model may stimulate eyes and such colors should be considered by use of buildings and rooms in the application of BIPV window. DSC BIPV has prospective diffusibility with the development of flexible module for the application of building surface.

Performance Evaluation Study of Solarwall-Photovoltaic Module to Generate Solar Electric Power (SWPV 태양 열-전기 복합생산 모듈 성능평가 연구)

  • Naveed Ahmed T;Kang E. C.;Lee E. J.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.397-402
    • /
    • 2005
  • Photovoltaic (PV) module can generate electricity using sunlight without causing any environmental degradation. Due to higher fossil fuel prices and environmental awareness, PV applications are becoming more popular as clean source of electricity generation. PV output is sensitive to the operating temperature and can be drastically affected in Building Integrated PV (BIPV) systems. PV Solarwall (SWPV) combination and PV systems have been evaluated in this study for improvement in electrical output and system costs. PV modules under forced ventilation. A 75W polycrystalline silicon PV module was fixed on SW in front of the ventilation fan as it was indicated to be the coolest position on the SW in phoenix simulations. The effectiveness of cooling by means of the forced ventilating air stream has been studied experimentally. The results indicate that there appears to be significant difference in temperature as well as electricity output comparing the SWPV and BIPV options. Electrical output power recovered is about $4\%$ during the typical day of the month of February. RETScreen(R) analysis of a 3kW PV system hypothetically located at Taegu has shown that with typical temperature reduction of $15^{{\circ}C$, it is possible to reduce the simple payback periods by one year. The work described in this paper may be viewed as an appraisal of a SWPV system based on its improved electrical and financial performances due to its ability to operate at relatively lower temperatures.

  • PDF

Performance characteristics of building-integrated transparent amorphous silicon PV system for a daylighting application (자연채광용 박막 투광형 BIPV 창호의 발전특성 분석 연구)

  • Yoon, Jong-Ho;Kim, Seok-Ge;Song, Jong-Wha;Lee, Sung-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.280-283
    • /
    • 2007
  • The first grid-connected, building-integrated transparent amorphous silicon photovoltaic installation has been operated since October 2004 in Yongin, Korea. The 2.2kWp transparent PV system was applied to the facade of entrance hall in newly constructed KOLON E&C R&D building. The PV module is a nominal 0.98m ${\times}$ 0.95m, 10% transparent, laminated, amorphous(a-Si) thin-film device rated at 44 Wp per module. To demonstrate the architectural features of thin film PV technologies for daylighting application, transparent PV modules are attached to the building envelope with the form of single glazed window and special point glazing(SPG) frames. Besides power generation, the 10% transmittance of a-Si PV module provides very smooth natural daylight to the entrance hall without any special shading devices for whole year. The installation is fully instrumented and is continuously monitored in order to allow the performance assessment of amorphous silicon PV operating at the prevailing conditions. This paper presents measured power performance data from the first 12 months of operation. For the first year, annual average system specific yield was just 486.4kWh/kWp/year which is almost half of typical amorphous silicon PV output under the best angle and orientation. It should be caused by building orientation and self-shading of adjacent mass. Besides annual power output, various statistical analysis was performed to identify the characteristics of transparent thin film PV system.

  • PDF

Study on the Long-term Reliability of Photovoltaic Module in the Cell level (태양전지의 Cell 레벨에서의 장기 신뢰성에 관한 연구)

  • Kim, Koung-Hwan;Jeon, Yu-Jae;Kim, Do-Sok;Jo, Il-Jea;Shin, Young-Eui
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.177-181
    • /
    • 2012
  • 본 연구는 고온고습 시험을 통하여 Cell 레벨에서의 표면관찰 및 효율저하를 분석하였다. 고온고습 시험 조건은 KS C IEC-61215에서 제시한 PV module하의 조건을 이용하여 온도 $85^{\circ}C$, 습도 85% 조건하에 1000시간 동안 수행하였다. 고온고습 시험에 따라 효율에 직접적인 영향을 줄 수 있는 이상 유 무를 Cell 표면을 통해 분석한 결과, 고온고습 시험 수행 중 부분적으로 변색되는 것을 확인하였다. 고온고습 시험 전 단결정 Cell의 효율은 17.74% 였으며, 1000시간 수행 후 15.63%으로 11.89%의 감소율을 보였다. 다결정 Cell의 시험 전 효율은 15.46%, 1000시간 수행 후 효율은 14.02%로 9.31%의 감소율을 보였다. 경년 시 나타나는 전기적 특성을 분석하기 위해 FF(Fill Factor)값을 분석한 결과, 고온고습 시험 전 단결정 Cell은 78.71%에서 75.01%로 4.7%의 감소율을 보였으며, 다결정 Cell은 78.10 %에서 76.66%로 1.84%의 감소율을 보였다. 효율 및 FF값에서 단결정 Cell이 다결정 Cell보다 감소율이 큰 것으로 분석되었으며, 이는 단결정 Cell이 외부 환경에서 더욱 크게 작용하여 효율저하에 영향을 주었다고 판단된다.

  • PDF

Development of a Greenhouse Monitoring System Using Network (네트워크를 이용한 온실 감시 시스템의 개발)

  • 임정호;류관희;진제용
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.53-58
    • /
    • 2003
  • This study was carried out to design, construct, and test a greenhouse monitoring system fur the environment and status of control devices in a greenhouse from a remote site using internet. The measuring items selected out of many environmental factors were temperature, humidity, solar radiation, CO$_2$, SOx, NOx concentration, EC, pH of nutrient solution, the state of control devices, and the image of greenhouse. The developed greenhouse monitoring system was composed of the network system and the measuring module. The network system consists of the three kinds of monitors named the Croup Monitor. the Client Monitor and the Server Monitor. The results of the study are summarized as follows. 1. The measuring module named the House Monitor. which is used to watch the state of the control device and the environment of the greenhouse, was developed to a embedded monitoring module using one chip microprocessor 2. For all measuring items. the House Monitor showed a satisfactory accuracy within the range of ${\pm}$0.3%FS. The House Monitors were connected to the Croup Monitor by communication method of RS-485 type and could operate under power and communication fault condition within 10 hours. The Croup Monitor was developed to receive and display measurement data received from the House Monitors and to control the greenhouse environmental devices. 3. The images of the plants inside greenhouse were captured by PC camera and sent to the Group Monitor. The greenhouse manager was able to monitor the growth state of plants inside greenhouse without visiting individual greenhouses. 4. Remote monitoring the greenhouse environment and status of control devices was implemented in a client/server environment. The client monitor of the greenhouse manager at a remote site or other greenhouse manager was able to monitor the greenhouse environment and the state of control devices from the Server Monitor using internet.

Analysis of Development Requirements on Simulated Ground Test Module for Underwater Residential Facilities (해저거주시설 모사 지상실험모듈 개발 요구사항 분석)

  • Joohee Lee;Younkyu Kim;Jongwon Lee
    • Journal of Space Technology and Applications
    • /
    • v.2 no.3
    • /
    • pp.206-220
    • /
    • 2022
  • There are various systems that allow humans to safely maintain their space exploration missions and lives in completely different environments, such as the International Space Station, the Moon (the closest celestial body to Earth), and Mars (the only planet in the solar system for manned mission in the 2030s). Among them, when it comes to maintaining the basic breathing of humans, the human life support air management system is a key device system. Such an air management system can be used not only for space exploration but also for undersea bases and submarines on Earth where humans reside. The air management system basically consists of an oxygen generation system, a carbon dioxide removal system, and a harmful substance removal system. In this paper, in order to develop an air management system that can be used in an underwater residential platform, the development requirements of a ground test module to be used as an experimental facility were analyzed.

An accurate sun tracking controller with reconstructing facility for fault sensor (오류신호보정기능을 갖춘 정밀 태양추적제어기)

  • Keun, Hyun-Woong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.9
    • /
    • pp.1913-1920
    • /
    • 2009
  • An intelligent accurate sun tracking controller for solar lighting system was developed. This controller can detect the faulty sensor and correct the error signal based on Principle Component Analysis theory. A fuzzy controller was developed to control the tracker by using the collected sensor signal for precise position control. Also a multiple range searching sensor module for sun tracking was designed. To show the validity of the developed system, some experiments in the field were illustrated.

The Effect on the Heating and Cooling Load of Building by Slat Angle Variation of Venetian Blind (베네치안 블라인드의 슬래트 각도변화가 건물의 냉난방 부하에 미치는 영향)

  • Cho, S.H.;Shin, K.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.171-183
    • /
    • 1995
  • Generally, among many kinds of shading devices such as venetian blind, sunscreen, louver and curtain, venetian blind is using widely because the mechanism is so simple and easy to use solar insolation by controlling the slat angle. Analysis of time dependent heat transfer through the window with venetian blind is very important in order to use it effectivly. Therefore, in this study, theoretical thermal analysis method was developed to analyze time dependent heat transfer through a double pane window with and without venetian blind, and was made one module of TRNSYS(A Transient Simulation Program)program. By this way, it was analyzed that how much the variation of slat angle, slat colour and slat absorptivity of venetian blind would be affected on the heating and cooling load of building, and also which colour and angle of slat was optimal for the heating and cooling load of building.

  • PDF