• Title/Summary/Keyword: Solar heat gain

Search Result 73, Processing Time 0.024 seconds

A study on the PAL according to thermal characteristic of building skin and perimeter zone depth (건물 외피의 열특성과 외주부 깊이에 따른 PAL에 관한 연구)

  • Kim, Ji-Hye;Kim, Hwan-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.2
    • /
    • pp.33-38
    • /
    • 2010
  • The perimeter zone is space which receives a significant effect of ambient condition, it is necessary to improve the thermal performance in order to building energy saving. For this reason, a lot of study about the active approach is being performed, such as perimeter-less air conditioning system. But the performance of the perimeter zone is necessary to improve, through the passive approach. Therefore, the purpose of this study is to provide basic materials of energy-saving design of perimeter zone, based of the PAL that simulation changing the thickness of insulation and the rate of windows.

An Evaluation of Application Possibility of Window System in the Building based on Optical Characteristics Analysis of DSSC (염료감응태양전지의 광학특성분석을 통한 건축창호 적용가능성 평가 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Jeong, Seon-Yeong;Baek, Nam-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.109-115
    • /
    • 2011
  • It can gain both the electric energy production and disperse of light at the same time if DSSC is applied in the building as window system. It means to help facade design and to be used in lighting, heating, cooling energy directly by applicating DSSC BIPV window that is possible to daylighting and materialization of color. For this, optical characteristics analysis that is basic step must take precedence. So, basic databases of DSSC are builded and optical performances according to the double and triple glazing are evaluated by analyzing spectral data of various colored DSSC. As a result, Green(4) has the highest visible transmittance that is 28.8%, and Blue(3) has the lowest that is 0.3%. And, in case of optical performance of Green(4) depending on the incidence angle, SHGC and Tsol are decreased sharply from more than $60^{\circ}C$. Finally, It is judged that Red(4), Green(1), (4), Blue(4) are suitable for application in office building because visible transmittance is high and solar heat gain coefficient is low relatively in spite of composing to double and triple glazing.

Energy Performance Evaluation of Apartment Building in Case of Applying a Blind Integrated Window System (전동 블라인드 내장형 창호시스템 적용에 따른 공동주택 에너지 성능평가 연구)

  • Choi, Gyeong-Seok;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.429-435
    • /
    • 2010
  • Although recently revised building code requires 15~20% increased thermal insulation performance for window systems, since the code is focusing on winter heat loss, it is not satisfactory to contribute on reducing rapidly rising cooling load in summer. Window systems have great impact on building heat gain and loss. Therefore technological development for window system specialized in shading solar gain in summer is an urgent matter. This study evaluates the performance of sun shading and thermal insulation for blind integrated window system. Also, computer simulation evaluates the effect of heating and cooling energy consumption reduction for an individual unit(floor area of $85m^2$) of a multi-family housing. Physibel Voltra, a heat transfer analysis software, was used to analyse the effect of energy consumption reduction, and the energy load was converted to the cost to compare the actual effect of economical benefit.

A Study on the Validation of Heliodon for Daylighting Performance Evaluation (자연채광성능 평가를 위한 태양고정형 Heliodon의 유용성 검증에 관한 연구)

  • Kim, Jeong-Tai;Lee, Ji-Hyun;Kim, Gon
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.51-62
    • /
    • 2004
  • Architects may evaluate building models to see how a building will shadow itself and its neighbors at various times. A heliodon, a tilt-table which is a machine that imitates the rotation and orbit of the Earth, helps architects wanting to analyze patterns of shadow patch, passive solar heating options, site solar panels, or control solar heat gain. The heliodon swivels in three directions for setting latitude, season, and time of day. Using the device, an architect first clamps a model to the tabletop, then turns the table to the coordinates of interest. Usually, the winter and summer solstices receive strong attention, for they represent extreme cases, A more recent installation at a university adds to its heliodon a set of lamps to recreate the illumination level and more accurate patterns of shadow patch. The table holds the building model at various angles to a spotlight, which mounts in the pole. The set of scale model measurement describes the validity of various electric lamps as an artificial sun to approximate the sun's parallel rays, helping designers to distinguish between illuminated areas in and around a building and those regions falling in the shadows.

Validation of Extended Building Heat Transfer Model (건축전열모델의 확장에 관한 연구)

  • 조민관
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.422-431
    • /
    • 2003
  • Theory of the building heat transfer is generally limited to the heat flux to the surfaces of windows and walls, which influences the indoor climate of a building, in the field of architectural environmental engineering. While the heat flux from the buildings to their environment has been considered in the viewpoint of urban climate, its conventional theory have been rarely examined. The purpose of this study is to propose a building-urban heat transfer model for defining the relation between the building and the urban climate by extending the building heat transfer model. In this study, the extended building heat transfer model, where response factor method is used, is established on the urban space and the indoor space by the boundary of building envelopes. Computer simulation (HASP/ACLD) is conducted on the subjected urban area by the established building-urban heat transfer model. As a result it is logically proved that the short waves of solar radiation, which interact with long Waves of radiation from the buildings and the earth, increase the urban air temperature ana buildings largely influence on the urban climate.

Design & Performance of the Solar Energy Research & Test Center (태양에너지 연구 시험센타 설계 및 효율에 관한 연구)

  • Auh, Paul Chung-Moo;Lee, Jong-Ho;Choi, Byung-Owan;Cho, Yil-Sik
    • Solar Energy
    • /
    • v.2 no.2
    • /
    • pp.29-36
    • /
    • 1982
  • The Solar Energy R&D Department of KIER under the auspice of the Korean government is pushing hard on the development of the passive solar technology with high priority for the expeditious widespread use of solar energy in Korea, since the past few years of experiences told us that the active solar technology is not yet ready for massive commercialization in Korea. KIER has completed the construction of the Solar Energy Research & Test Center in Seoul, which houses the major facilities for its all solar test programs. The Center was designed as a passive solar building with great emphasis on the energy conserving ideas. The Center is not only the largest passive building in Korea, but also the exhibit center for the effective demonstration of the passive heating and cooling technology to the Korean public. The Center was designed to satisfy the requirements based on the technical and economical criteria set by the KIER. Careful considerations, therefore, were given in depth in the following areas to meet the requirements. 1) Passive Heating Concepts The Center employed the combination of direct and indirect gain system. The shape of the Center is Balcomb House style, and it included a large built-in sunspace in front. A partition, consists of transparent and translucent glazings, separates the sunspace and the living space. Since most activities in the Center occur during the day time, direct utilization of the solar energy by the living spaces was emphasized with the limited energy storage capacity. 2) Passive Cooling Concepts(for Summer) Natural ventilation concept was utilized throughout the building. In the direct gain portion of the system, the front glazing can be openable during the cooling season. Natural convection scheme was also applied to the front sunspace for the Summer cooling. Reflective surfaces and curtains were utilized wherever needed. 3) Auxiliary Heat ing and Cooling System As an auxiliary cooling system, mechanical means(forced convection system) were adopted. Therefore forced air heating system was also used to match the duct work requirements of the auxiliary cool ing system. 4) Effect ive Insulation & Others These included the double glazed windows, the double entry doors, the night glazing insulation, the front glazing-frame insulation as well as the building skin insulation. All locally available construction materials were used, and natural lightings were provided as much as possible. The expected annual energy savings (compared to the non-insulated conventional building)of the Center was estimated to be about 80%, which accounts for both the energy conservation and the solar energy source. The Center is being instumented for the actual performance tests. The experimental results of the simplified tests are discussed in this paper.

  • PDF

Comparative Analysis of Surface Heat Fluxes in the East Asian Marginal Seas and Its Acquired Combination Data

  • Sim, Jung-Eun;Shin, Hong-Ryeol;Hirose, Naoki
    • Journal of the Korean earth science society
    • /
    • v.39 no.1
    • /
    • pp.1-22
    • /
    • 2018
  • Eight different data sets are examined in order to gain insight into the surface heat flux traits of the East Asian marginal seas. In the case of solar radiation of the East Sea (Japan Sea), Coordinated Ocean-ice Reference Experiments ver. 2 (CORE2) and the Objectively Analyzed Air-Sea Fluxes (OAFlux) are similar to the observed data at meteorological stations. A combination is sought by averaging these as well as the Climate Forecast System Reanalysis (CFSR) and the National Centers for Environmental Prediction (NCEP)-1 data to acquire more accurate surface heat flux for the East Asian marginal seas. According to the Combination Data, the annual averages of net heat flux of the East Sea, Yellow Sea, and East China Sea are -61.84, -22.42, and $-97.54Wm^{-2}$, respectively. The Kuroshio area to the south of Japan and the southern East Sea were found to have the largest upward annual mean net heat flux during winter, at -460- -300 and at $-370--300Wm^{-2}$, respectively. The long-term fluctuation (1984-2004) of the net heat flux shows a trend of increasing transport of heat from the ocean into the atmosphere throughout the study area.

A Study on Solar Radiation Analysis and Saving Elements of Heating Load according to the Location and Type of Housing in Multi-family Apartments (공동주택 주동형태별 세대위치에 따른 일사분석 및 난방부하 절감요소에 관한 연구)

  • Kim, Soo-Jeong;Park, Doo-Yong;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.47-55
    • /
    • 2013
  • This study aims to evaluate the correlation between vertical solar radiation and the level of heating load according to the location and type of housing in multi-family apartments. This study shows that heating load is related with factors such as wall loss, window loss, ventilation loss and solar radiation gain. The heating load increases in the order of the middle floors, the highest floors and the lowest floors. The lowest and the highest floors are the most vulnerable floors, and it should be as emphasized as the middle floors. The heating load saving proposal contains 52 Alt. that shows heating load savings from min. 4% to max. 49%. The goal is to reduce the heating load of the highest and the lowest floors to the level of the middle floors. The result showed that there are 3 Alt. for the lowest floors and 16 Alt. for the highest floors as the heating load saving proposal. This study suggests integrated application to compose saving elements of heating load. so it could be utilized as a data for the construction of passive houses.

Technology Development Trends of Self-Powered Next Generation Smart Windows (PV 일체형 차세대 스마트 윈도우 기술개발 동향)

  • Pyun, Sun Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.12
    • /
    • pp.753-764
    • /
    • 2015
  • Among several types of energy saving smart window technologies, the leader, the dynamic EC (electrochromic) window one needs integrated PV (photovoltaics), to minimize expensive electrical wiring as well as to obviate the need for external energy. Self-powered smart windows were reviewed according to PV types used. DSSCs (dye sensitized solar cells) were found to be compatible with EC cells, to have several categories of next generation smart windows such as PECCs (photoelectrochromic cells), PVCCs (photovoltachromic cells), EC polymer PECCs. In addition silicon solar cells and third generation solar cells were investigated. They are summarized in a table showing their advantages and disadvantages respectively for a fast comparison. The strategy to expedite the commercialization of these next generation smart windows includes developing retrofit smart window coverings for use on flexible polymer substrates adhered to the inside surface of a window and easily replaced after use for upto 10 years.

A Study on Heating Load Analysis of Zero Energy Solar House Considering the Effective Transmittance of Window (창호의 유효투과율을 고려한 제로에너지 태양열 주택의 난방부하 분석에 관한 연구)

  • Son, Sun-Woo;Baek, Sang-Hun;Lee, Hyun-Soo;Baek, Nam-Choon;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.62-69
    • /
    • 2009
  • To reduce the building energy consumption, the major advanced nations are conducting actively many researches on so called a "self-sufficient building(or other words zero energy building)" which can support its required energy by itself. Given this background, KIER(Korea Institute of Energy Research) built full size test-bed of the zero energy solar house in early 2001, and has studied on the self-sufficient heating load up to now. We analyse the sensitivity between the heating load and the solar radiation gain according to the change the effective transmittance of windows. The authors classified 9 cases by solar transmittance of glass. The results demonstrate the solar radiation amount is 0.466 MWh from the eastern zone of Fl.,1(the first floor), 0.332 MWh from Fl.,2(the second floor), 1.194 MWh form the southern zone of F1., and 0.822 MWh from the southern zone of Fl.,2 on the case 1(each cases are classified by window types). On the case 9, the solar radiation amount is 3.127 MWh, 2.662 MWh, 8.799 MWh and 6.078 MWh from the same condition. For the Fl.,1, the amount of Heat Load that is saved per year ranged 10.5 to 48%, and the reduction was anywhere from 0.2 to 17.9% for Fl.,2.