• 제목/요약/키워드: Solar daylighting system

검색결과 59건 처리시간 0.023초

Embossed Structural Skin for Tall Buildings

  • Song, Jin Young;Lee, Donghun;Erikson, James;Hao, Jianming;Wu, Teng;Kim, Bonghwan
    • 국제초고층학회논문집
    • /
    • 제7권1호
    • /
    • pp.17-32
    • /
    • 2018
  • This paper explores the function of a structural skin with an embossed surface applicable to use for tall building structures. The major diagrid system with a secondary embossed surface structure provides an enhanced perimeter structural system by increasing tube section areas and reduces aerodynamic loads by disorienting major organized structure of winds. A parametric study used to investigate an optimized configuration of the embossed structure revealed that the embossed structure has a structural advantage in stiffening the structure, reducing lateral drift to 90% compared to a non-embossed diagrid baseline model, and results of wind load analysis using computational fluid dynamics, demonstrated the proposed embossed system can reduce. The resulting undulating embossed skin geometry presents both opportunities for incorporating versatile interior environments as well as unique challenges for daylighting and thermal control of the envelope. Solar and thermal control requires multiple daylighting solutions to address each local façade surface condition in order to reduce energy loads and meet occupant comfort standards. These findings illustrate that although more complex in geometry, architects and engineers can produce tall buildings that have less impact on our environment by utilizing structural forms that reduce structural steel needed for stiffening, thus reducing embodied $CO^2$, while positively affecting indoor quality and energy performance, all possible while creating a unique urban iconography derived from the performance of building skin.

자연채광 이용에 따른 조명에너지 예측방법에 관한 연구 (A Study on Lighting Energy Prediction by Using Daylight during Daytime)

  • 정유근;김정태
    • 태양에너지
    • /
    • 제11권2호
    • /
    • pp.9-19
    • /
    • 1991
  • 주된 사용시간이 주간인 사무소 건물에서 주광의 이용에 따른 연간 에너지 절약효과는 매우 큰 것으로 나타나고 있다. 더욱이 주광의 효과적인 이용은 작업자의 쾌적감과 만족감을 증가시키면서 수적으로 작업성능 또한 향상시킬 수 있다. 주광의 이용여부는 건축설계의 기본요소들이 검토되는 초기설계단계에서 검토되어야 한다. 따라서, 본 연구는 초기설계단계에서 주광의 이용에 따른 연간 조명에너지 절약률을 예측할 수 있는 평가도구를 개발하는데 연구목적이 있다. 이러한 평가도구로서 본 연구에서 개발한 노모그래프는 편측창 모델사무실을 대상으로 인공조명기구의 소등률과 조절방식에 따라 연간 조명에너지량을 예측할 수 있다. 이 노모그래프는 디자인 초기단계에서 유용한 자연채광 설계도구로서 이용될 수 있을 것이다.

  • PDF

광화이버 및 Fresnel lens 적용 집광식 자연채광 시스템의 이용을 통한 조명에너지의 절감 : 시뮬레이션 및 실측 비교 (Electric lighting energy saving through the use of a Fresnel lens based fiber-optic solar lighting system : Simulation and measurements)

  • 정해준;김원식;김영민;한현주;천원기
    • 에너지공학
    • /
    • 제26권1호
    • /
    • pp.34-44
    • /
    • 2017
  • 본 연구에서는 2축의 태양추적장치에 프레넬 렌즈를 장착한 fiber-optic 설비형 자연채광시스템의 효율성에 대하여 이론적 분석을 수행하였다. ECOTECT와 RADIANCE를 기반으로 시뮬레이션 모델을 개발하여 다양한 조건하에서 자연채광 시스템뿐만 아니라 형광등을 이용한 인공조명에 대한 실내 조도분석과 함께 실측 데이터와의 비교연구를 수행하였다. 형광등을 이용한 실내조명의 경우, 평균조도는 사무실 실내 조도 기준을(KS A 3011 일반 사무실 [G]등급[300-400-600lux]) 충분히 만족하는 결과를 보여주었다. 한편, 디퓨져를 사용한 자연채광시스템의 경우도 사무실 실내 조도 기준을 넘는 것으로 나타났다.

사무공간 적용 BIPV시스템의 자연채광 및 성능평가에 관한 연구 (A Study on Evaluation of Daylighting in Office Space Applied BIPV Systems in Accordance with Power Performance)

  • 서영석;오민석;김회서
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.148-154
    • /
    • 2009
  • By the skyscraper building, increase of skin area and expansion of curtain wall system will be the important factors of acceleration in extending supply of BIPV system. In the future interior environmental evaluation is not a necessary to the residents but an essential term which will bring enormous influence. In the interior environmental evaluation, natural light will let the residents with direct contact with outside circumstances and make them feel opened. also only the daylight has radiant energy and color rendering that will have a great influence to residents' mental, operation efficiency and advancing productivity. This research compares and analyzes BIPC system in office spaces with two general sunlight's module. In addition to natural light's efficiency for BIPC system's comfort and confirmed economical efficiency will be applied to basic research data. Hence forth, ensuring indoor intensity of illumination and controlling light system to reducing energy research data will be demanded to increase the amount of supplying BIPC system. Also continuance research in the possibility of applying BIPC system in various buildings, room temperature affected by location of windows and its condensation, and economical evaluation will be required.

  • PDF

Analysis of Energy Performance and Green Strategies in the Foreign High-Performance Buildings

  • Park, Doo-Yong;Kim, Chul-Ho;Lee, Seung-Eon;Yu, Ki-Hyung;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • 제15권3호
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: In this study, we analyzed the energy performance levels and high-performance technology trends through the case studies of foreign high-performance buildings. Method: Buildings built within 10 years were selected for the analysis of recent trends. we analyzed the buildings of U.S.A, Germany and Japan using LEED certified buildings, Passive House certified buildings and CASBEE certified buildings database for the case study of foreign high-performance buildings. A total of 20 high-performance buildings including 14 cases in U.S.A, 4 cases in Germany and 4 cases in Japan were selected. Annual energy consumption levels for 20 high-performance buildings were collected with the actual energy consumption data or data from simulation programs officially recognized by DOE. Annual energy consumption were compared with the energy performance standard of the office buildings in the CBECS database, ASHRAE Standard 90.1-2004 and Building Energy Efficiency Rating System in Korea. Result: The order of the green strategies applied in the main categories are Renewable Energy(63%), Indoor Environment Control(51%), Envelope Improvement(44%) and HVAC System & Control(28%). Specified strategies most widely used in the sub-categories are high-performance Insulation (70%), High Efficiency Heating, Cooling Source Equipment(85%), Photovoltaic&Solar Thermal(80%) and Daylighting(80%).

AHP 방법을 이용한 노후학교 에너지절감을 위한 요소기술의 우선순위 결정 (Determining the Priority of Factors for Reducing Energy at Deteriorated School Buildings Using AHP Method)

  • 이상춘;최영준;최율
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.127-132
    • /
    • 2011
  • Since the late 20th century, countries of the world have made every effort to solve environmental problems due to global warming. The Korean Government has also made various efforts on reducing energy and $CO_2$ emission under the motto of "Low-Carbon Green Growth". In order to achieve the goal to reduce energy in the construction field, severe design standards and regulations on saving energy in new buildings have been established. However, for maximizing the reduction of energy in buildings, it is time to focus on deteriorated buildings where applications of energy saving designs and techniques have been insufficient. Especially, there are little guidelines and researches on reducing energy through remodeling at deteriorated school buildings which were built over 20 years ago. This paper suggests the priority of factors to reduce energy on the remodeling process at deteriorated school buildings using the AHP(Analytic Hierarchy Process) method. For applying the AHP method, the survey of staffs in the Education Offices and board members in the Korea Institute of Ecological Architecture and Environment was conducted via e-mail. As a result, factors of insulation, daylighting, system control, and windows turned out important in the energy reducing remodeling process at deteriorated school buildings, while factors of artificial lighting, solar heating, ventilation, and system did relatively unimportant.

전기변색 외피시스템 적용 업무공간의 채광 성능 분석 (Daylighting Performance of Office Space Applied with Electrochromic Façade System)

  • 김재향;한승훈
    • 토지주택연구
    • /
    • 제13권1호
    • /
    • pp.131-140
    • /
    • 2022
  • 스마트 윈도우는 건물의 에너지 절감을 실현할 수 있는 신소재 건축 자재이며, 상황에 따라 가시광선 투과율(Visible Light Transmittance), 일사획득계수(Solar Heat Gain Coefficient, g-value)를 자유롭게 조절할 수 있는 특징을 가진다. Electrochromic(EC), Suspended Particle Device(SPD), Polymer Dispersed Liquid Crystal(PDLC) 등이 스마트 윈도우에 해당되며 현재 실용화 단계에 있다. 최근 스마트 윈도우의 VLT 및 g-value 조절 기능을 통해 건축물의 에너지를 절감하는 방법에 대한 연구가 활발하게 진행되고 있으며, 일부 유의미한 결과가 도출되고 있다. 하지만, 건축물의 에너지 절감에 대해서 연구의 영역이 제한되어 있고, 실내 환경에 대한 연구는 다소 부족한 실정이다. 에너지 절감에만 초점을 맞춘 실내 공간은 충분한 쾌적성이 확보되지 않기 때문에 실내 환경에 대한 고려가 요구된다. 따라서 이 연구에서는 사무공간을 기준으로 채광성능(Daylight Performance) 분석이 수행되었다. 세계 각 국의 친환경 건축인증제도인 LEED, BREEAM, CASBEE, G-SEED의 기준을 통해 스마트 윈도우의 VLT 조절에 따른 채광성능 검토가 이루어졌으며, 쾌적한 실내 채광환경을 유지할 수 있는 스마트 윈도우의 VLT 범위에 대한 고찰이 이루어졌다. 분석을 위해 사용된 스마트 윈도우는 VLT 조절 범위가 가장 넓은 EC가 사용되었다. 분석 결과 한국의 친환경 건축인증제도인 G-SEED의 평균주광률을 충족하기 위한 스마트 윈도우의 최소 VLT는 25% 이상으로 나타났으며, 스마트 윈도우의 VLT 조절은 균제도에 유의한 영향을 미치지 않는 것으로 나타났다. 또한, LEED의 실내 최소조도의 기준을 적용할 시 적용되어야 하는 계절 및 향에 대한 스마트 윈도우의 VLT 조절 범위 값이 도출되었다.

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • 제5권4호
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

베네시안 블라인드의 높이와 슬랫각도 조절에 따른 계절별 실내주광분포 분석 (Daylight Assessment of Venetian Blind by Shading Heights and Slat Angles)

  • 신화영;김곤;김정태
    • KIEAE Journal
    • /
    • 제11권2호
    • /
    • pp.105-111
    • /
    • 2011
  • Aims of this study is to investigate the daylighting control strategy of venetian blind system was performed as a function of ratio of shading height to window and slat angles in the preliminary stage of the parametric study. Floor-to-ceiling window walls of living spaces are used widely in apartment buildings since the Korean government has legally allowed elimination of the balcony area. Enlarging living area by balcony elimination, the larger glass area of window is exposed to the direct sunlight. As a common sunlight controlling device, blind system can be used in all orientations and all latitudes and it may obstruct, absorb, reflect and transmit solar radiation to building by proper adjusting. However, blind system can produce discomfort in occupant and less energy efficiency, if it has not been controlled optimally. The simulation model was based on the unit module of typical living space with balcony elimination. The room dimension was $6.0m(w){\times}6.9m(d){\times}2.7m(h)$ with floor to ceiling height of 2.5m. The blind system was simulated at five slat angles (horizontal, $30^{\circ}$, $45^{\circ}$ upward and downward tilted) and the four ratio of shading height to window (fully closed, partly opened, no-blind) using the Desktop RADIANCE 2.0 program. The series of simulation results indicates that the advantages of available daylight and outside of view can be improved by proper adjusting blind system.