• Title/Summary/Keyword: Solar daylighting

Search Result 94, Processing Time 0.024 seconds

Performance Evaluation of Applied to Natural Light and Artificial Lighting Hybrid Dimming Control System (자연조명과 인공조명이 병행 적용된 하이브리드 디밍제어시스템의 성능평가)

  • Sung, Tae-Kyung;Lee, Chung-Sik;Kim, Byung-Chul;Joung, Che-Bong;Kang, Seung-Hoo
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.66-74
    • /
    • 2014
  • In this paper, the performance of Hybrid Dimming control system for Daylighting system is evaluated by accredited tests. The system controls the balance of illuminance of daylight between daylight system and LED light system. It makes the normal illuminance of interior without the effects of weather by controlling the LED depending on the brightness of outside. For the tests, 6 diffusers($600{\times}300mm$) were installed in lighting area($36m^2$) and normal operation of the system sensors were tested about the interference of sunlight. The results of the examinations were satisfied with the criteria of accredited tests. Further research is the verification of energy saving effect by comparing the Hybrid Dimming control system to current artificial light system.

The Study on the Application of Accurate Solar Tracking Algorithm by using LabVIEW (태양정밀추적 알고리즘의 LabVIEW 적용 연구)

  • Oh, Seung-Jin;Kin, Young-Min;Lee, Yoon-Joon;Cho, Yil-Sik;Chun, Won-Gee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.121-125
    • /
    • 2009
  • There have been many developed systems for harnessing the solar energy such as solar water heaters, solar thermal power systems, PV systems, daylighting and solar hydrogen systems. all of them are capable of reducing $CO_2$ emission. However, the efficiency of those systems which work without a solar tracker is lower. This paper is a step by step procedure for fabrication and a performance test of a solar tracking system. The system developed in this study consists of motion controllers, motor drives, step-motors, feedback devices and application. CdS sensors are introduced into the solar tracking system for playing a primary role in poor conditions for tracking due to a gear backlash and a strong wind. Mini-dish was used as a concentrator for collecting sun light. The solar position data, in terms of azimuth and elevation, sunrise and sunset times was compared with those of KASI(Korea Astronomy & Space Science Institute). The results presented in this article provide the high accuracy of the present system in solar tracking and indicate a potential for energy savings.

  • PDF

A Study on the Indoor Environment Evaluation and Improvement of the Atrium in Summer (하계 아트리움 실내환경 평가 및 개선방안에 관한 연구)

  • Nam, Jung-Woo;Kwon, Kyung-Woo;Won, Jong-Seo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.216-221
    • /
    • 2009
  • The purpose of this study is to evaluate and improve the indoor environment of the Atrium in summer. Thermal and daylighting performance was evaluated quantitatively by integrated simulation according to 4 types of shading device.(none shading, opaque shading, translucent shading, internal blind) As a result, with internal blind, the effects of isolating solar radiation and reducing indoor temperature are estimated to be decreased by about 90% and $3.2^{\circ}C$. In the outer shading device which is controled according to solar altitude, the effects of isolating solar radiation and reducing indoor temperature are revealed to be decreased by about 82% and $4.9^{\circ}C$.

  • PDF

An Evaluating of Daylighting Performance by Venetian Blind Shapes Type Change - Centre on Radiance Program (베네치안 블라인드 슬랫각도 형태변화에 따른 주광성능에 관한 연구 - Radiance Program 중심으로)

  • Lim, Tae Sub;Park, Jong Myung;Lim, Jung Hee;Kim, Byung Seon
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.59-66
    • /
    • 2013
  • Current Architectural Facade Designs have been trending to increased glass areas resulting in increasing impact on interior lighting and daylighting. In regards to indoor environmental quality, the increase in window space has a large impact on the daylighting received which ultimately impacts the liveability of a space. Especially when considering seasons, in the summer, excessive daylighting can result in glare as well as put an increased load in conditioning the air space further reducing energy efficiency. As a result, in order to improve the sustainability performance of a building, it is important to limit the natural lighting exposure to properly meet the needs and conditions of the building occupants. One of the most representative features to limit excessive sunlight exposure, is to incorporate operable blind systems. To this end, this research has been based on simulations performance through the Radiance Program. Radiance is capable of analyzing performance of daylight and impact of sunlight. Through analysis of different slat angles and blind shapes, impact and minimization of energy usage was evaluated. Furthermore, seasonal analysis was performed in order to understand the effects of seasonal climate factors. Ultimately this research provides an analysis of operable blinds optimization and effects of blind shape, control factors and angle of shading.

Trends of International Daylight Measurement Programme (국제 자연채광 측정 프로그램의 동향)

  • Kim, Hway-Suh
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.30-36
    • /
    • 1993
  • In recent year in many countries with various climatic conditions are becoming very widely used with daylighting system based on maximum used of the Sunlight. This paper will present on trend of International Daylight Measurement program which has already organized by CIE technical committe called TC307. The International Daylight Measurement Year(IDMY) has been decided to be initiated at the beginning of 1991 to collect various kind of daylight and solar radiation data all over the world.

  • PDF

Electric Lighting Energy Saving Through the Use of A Fresnel Lens Based Fiber-optic Solar Lighting System: Simulation and Measurements (광화이버 및 Fresnel lens 적용 집광식 자연채광 시스템의 이용을 통한 조명에너지의 절감: 시뮬레이션 및 실측 비교)

  • Jeong, Haejun;Kim, Wonsik;Kim, Yeongmin;Han, Hyun Joo;Chun, Wongee
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.1-12
    • /
    • 2017
  • This paper deals with the effectiveness of a fiber optic solar lighting system that uses a Fresnel lens mounted on a two-axis solar tracker. A series of comparative analyses were made concerning its performance as compared to fluorescent lighting by using a simulation model based on ECOTECT and RADIANCE as well as referring to actual data. ECOTECT was used to model the test room (space) while RADIANCE was used for its indoor lighting conditions (environment). It was found that the average indoor light levels of fluorescent lighting fully satisfy the KS standard (KS A 3011, general office, class [G]: 300-400-600 lux) whereas those of the solar lighting with light diffusers depends on the occlusion factor of roller shades installed on the south window.

A Study on the Validation of Heliodon for Daylighting Performance Evaluation (자연채광성능 평가를 위한 태양고정형 Heliodon의 유용성 검증에 관한 연구)

  • Kim, Jeong-Tai;Lee, Ji-Hyun;Kim, Gon
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.51-62
    • /
    • 2004
  • Architects may evaluate building models to see how a building will shadow itself and its neighbors at various times. A heliodon, a tilt-table which is a machine that imitates the rotation and orbit of the Earth, helps architects wanting to analyze patterns of shadow patch, passive solar heating options, site solar panels, or control solar heat gain. The heliodon swivels in three directions for setting latitude, season, and time of day. Using the device, an architect first clamps a model to the tabletop, then turns the table to the coordinates of interest. Usually, the winter and summer solstices receive strong attention, for they represent extreme cases, A more recent installation at a university adds to its heliodon a set of lamps to recreate the illumination level and more accurate patterns of shadow patch. The table holds the building model at various angles to a spotlight, which mounts in the pole. The set of scale model measurement describes the validity of various electric lamps as an artificial sun to approximate the sun's parallel rays, helping designers to distinguish between illuminated areas in and around a building and those regions falling in the shadows.

A Study on Solar Light Collector using Fresnel Lens Film (프레넬 필름을 이용한 태양광 채광시스템 연구)

  • Jeong, H.G.;Han, S.B.;Jung, B.M.;Lee, E.J.;Lim, S.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.1
    • /
    • pp.81-86
    • /
    • 2002
  • Solar daylighting system provides free and comfort lighting, but its design and control has been key issue due to heavy light collecting system. One of the solutions for the heavy weight issues would be using a light framed film such as fresnel and prism lens. This prototype system consists of light collector, light transformer and light guide luminaire. The light collector which is installed at window or the rooftop concentrates solar light, the collected beam is converted to suitable light by the light transformer. and the prism light guide luminaire has been used to distribute light emitted from light transformer for illumination. In this paper, the design concept and performance of light collector in this prototype system are presented.

Performance characteristics of building-integrated transparent amorphous silicon PV system for a daylighting application (자연채광용 박막 투광형 BIPV 창호의 발전특성 분석 연구)

  • Yoon, Jong-Ho;Kim, Seok-Ge;Song, Jong-Wha;Lee, Sung-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.280-283
    • /
    • 2007
  • The first grid-connected, building-integrated transparent amorphous silicon photovoltaic installation has been operated since October 2004 in Yongin, Korea. The 2.2kWp transparent PV system was applied to the facade of entrance hall in newly constructed KOLON E&C R&D building. The PV module is a nominal 0.98m ${\times}$ 0.95m, 10% transparent, laminated, amorphous(a-Si) thin-film device rated at 44 Wp per module. To demonstrate the architectural features of thin film PV technologies for daylighting application, transparent PV modules are attached to the building envelope with the form of single glazed window and special point glazing(SPG) frames. Besides power generation, the 10% transmittance of a-Si PV module provides very smooth natural daylight to the entrance hall without any special shading devices for whole year. The installation is fully instrumented and is continuously monitored in order to allow the performance assessment of amorphous silicon PV operating at the prevailing conditions. This paper presents measured power performance data from the first 12 months of operation. For the first year, annual average system specific yield was just 486.4kWh/kWp/year which is almost half of typical amorphous silicon PV output under the best angle and orientation. It should be caused by building orientation and self-shading of adjacent mass. Besides annual power output, various statistical analysis was performed to identify the characteristics of transparent thin film PV system.

  • PDF

Evaluation of Daylighting Performance and Design of a Curved-Lightshelf by the Ray Tracing Method (광선추적기법을 활용한 곡면형 광선반시스템 설계 및 채광성능 평가)

  • Kim, Dong-Su;Yoon, Jong-Ho;Shin, Woo-Chul;Lee, Kwang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.136-141
    • /
    • 2011
  • The lightshelf system reduces intense illumination levels of indoor from direct sun light and reflect to lead diffused light into indoor deeply. This study aims to design acurved-lightshelf by a ray tracing method and evaluate the daylighting performance of window integrated with the curved-lightshelf by computer simulations. For this purpose, evaluation test model was designed for the experiments to validate the simulation model, and the curved-lightshelf was designed by the ray tracing method using Ecotect. After the office model was designed using 3D simulation, the average indoor illuminance, luminance and distribution of illuminance were evaluated by simulation which has a algorithm of Radiosity and Ray-Tracing method under four different cases(case1;no lightshelf, case2; Flat board, case3; tilted at $30^{\circ}$ angle, case4; the curved-lightshelf). As results, it turns out that case1 showed higher average illuminance and case4 was more uniformly distributed than case2 and case3, In addition average luminance of case1 was also lower. indicating that the curved-lightshelf would reduce the possibility of the glare, while maintaining the sufficient daylight level.