• Title/Summary/Keyword: Solar Storage

Search Result 615, Processing Time 0.022 seconds

Effects of Various Kinds of Salt on the Quality and Storage Characteristics of Tteokgalbi

  • Lee, Hyun-Joo;Lee, Jae-Joon
    • Food Science of Animal Resources
    • /
    • v.34 no.5
    • /
    • pp.604-613
    • /
    • 2014
  • This study was carried out to evaluate the effects of various kinds of salt on the quality and storage characteristics of tteokgalbi. The tteokgalbi was prepared using four types of salt: 1.5% purified salt (control, C), 1.5% five-year-old solar salt (FS), 1.5% Topan solar salt (TS), and 1.5% French Gu$\acute{e}$rande solar salt (GS). The moisture, crude lipid, crude ash, crude protein and calorie contents, water holding capacity, and cooking loss were not significantly different between control and all other treatments. As for the textural characteristics, the use of GS increased the hardness of the tteokgalbi. According to the sensory evaluation, the use of TS had the best score in springiness. Tteokgalbi made with TS and GS had the two highest scores in flavor and total acceptability. During 15 d of storage, the contents of 2-thiobarbituric acid (TBA) value, volatile basic nitrogen (VBN) and the total microbial counts increased, while the pH decreased. The TBA values of the tteokgalbi containing TS and GS were lower than that of C. Lightness (L) and yellowness (b) values decreased during storage, but redness (a) displayed no significant difference during storage. Overall, the best results, in terms of TBA value and sensory attributes, were obtained for the tteokgalbi containing TS and GS.

Performance of Natural Circulation Hot Water System with Flat-Plate Solar Collectors (평만형 태양열 집열기 를 설치한 자연 순환식 급탕시스템 의 성능 에 관한 연구)

  • 윤석범;전문헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.579-589
    • /
    • 1985
  • The storage tank of the natural-circulation-solar-hot-water system equipped with flat-plate solar collectors is located at higher elevation than the solar collectors. Therefore, the heat loss from the system due to a reversed flow during the night-time is an important factor as well as the day-time thermal performance of the system. The thermal performance of the natural-circulation-solar-hot-water system with flat-plate solar collectors during the day-time depends mainly on the heat collecting efficiency of the solar collectors, whereas its thermal performance during the night-time depends on the system configuration , such as the elevation of the water storage tank with respect to the solar collectors and the piping connections between the storage tank and the solar collectors, as well as thermo-physical properties of the circulating fluid. In the present work, a computer program has been developed to simulate a typical natural-circulation-solar-hot-water-system, and a series of simulation tests have been carried out with the computer program to examine the thermal performance of the system during the day-time as well as the hight-time. In addition , a series of experiment have been conducted under a real sun condition using a natural-circulation-solar-hot-water-system constructed and installed at the KAIST building to compare with the results obtained from computer simulations.

Experiment on the Charge and Discharge of Thermal Energy for Under-Water Harvest-Type Ice Storage System (수중 하베스트형 빙축열시스템의 축방냉 특성 실험)

  • Kim, J.D.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.11-17
    • /
    • 2002
  • This paper is concerned with the development of a new method for making, separating ice and storage floated ice by installing an evaporation plate at under-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating an ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. Developed new harvest-type method shows good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, however these components are not necessary in a new method. In this study ice storage systems are experimentally investigated to study the charge and discharge of thermal energy. The results show the applicable possibility and performance enhancement of a new type.

Technical Trend of Receiver for Solar Power Tower (타워용 태양열발전 시스템 흡수기 기술동향)

  • Kim, Jong-Kyu;Kim, Jin-Soo;Lee, Sang-Nam;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.161-164
    • /
    • 2008
  • For the development of solar thermal power tower plant from the early 80' to today, various kinds of receiver have been tested and evaluated. Most of 1st generation receiver used water/steam as a working fluid to operate steam turbine and now the first commercial solar power tower PS-10 also makes saturated steam. However, to increase thermal efficiency of storage system and to obtain practical use of solar energy, molten salt system have been used from THEMIS project in France at 1984. The Solar Tres plant of 17 MWe power generation will be constructed in Spain and have plan to operate 24 hours in summer. The air volumetric receiver system can be integrated with combined cycle of gas turbine and HRSG and also with steam turbine easily. Therefore, related researches to develop higher efficient solar power tower plant and to operate with stable are widely performed in the world.

  • PDF

Preparation and Properties of $TiO_2$ Films for Solar Energy Utilization (태양에너지이용을 위한 $TiO_2$ 박막의 제작과 특성)

  • Lee, Kil-Dong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.90-97
    • /
    • 2010
  • $TiO_2$ thin films for solar energy utilization were prepared on ITO coated glass by r.f magnetron sputtering with variations of working pressure, oxygen flow rate and annealing temperature. Ion insertion and extraction reaction, and ion storage properties of films were investigated by using a cyclic voltammetry. Transmittance of thin films in as-prepared, colored and bleached states was measured by UV-VIS spectrophotometer. The samples deposited in our sputtering conditions showed poor electrochromic properties. Improvement in ion storage properties of $TiO_2$ thin film was observed after annealing at temperature of $400^{\circ}C$ in air for 2 hours. It was found that $TiO_2$ thin film in electrochromic device could be used as a passive counter-electrode.

An Experimental Study on the Temperature Variation in Heat Storage Zone in the Honeycomb-covered Small Saltless Solar Pond (벌집형 소형 태양열 저장수조의 열저장층 내의 온도변화에 관한 실험적 연구)

  • Pak, Ee-Tong;Hwang, Sung-Il;Hahn, Dong-Kyun
    • Solar Energy
    • /
    • v.9 no.1
    • /
    • pp.30-35
    • /
    • 1989
  • This paper dealt with an experiments on temperature vairation in the heat storage zone due to change of vertical location (height) of sink diffuser and flow extraction in small saltless solar pond ($0.5{\times}0.5{\times}1.0M$), and the honeycomb device for this experimental purpose consisted of one-tired, sealed, and air filled by honeycomb panels. As results of experiments, 1) The storage zone was formed under lower region below the honeycomb device. 2) The higher vertical location of sink diffuser was placed, the more mixing phenomenon increased in the pond at steady flow extraction. 3) The more flow extraction increased, the more mixing phenomenon decreased at constant heat exchanger and variable flow extraction.

  • PDF

Experimental Verification for a Spiral-Jacketed Storage Tank Applied to Solar Thermal System (태양열 시스템에 적용된 나선재킷형 축열조의 실증실험)

  • Kim Jin Hong;Choi Bong Su;Hong Hiki;Kim Yong-Shik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.341-346
    • /
    • 2005
  • The simplification of solar thermal systems reduces the possibility of operating trouble and lowers the cost of the initial investment and maintenance. This also leads to increased competitiveness in the energy market. We proposed a spiral-jacketed storage tank that functions both as a heat exchanger and expansion tank, which removes the secondary piping and markedly simplifies the entire system. The new storage tank was designed and manufactured to maintain the same performance as the conventional system and the exiting system was remodelled by adopting the newly proposed storage tank. This experiment was conducted under real conditions over a period of several months. The retrofitted system with the spiral-jacketed storage tank showed good performance that is on a similar level as the previous system having a typical storage tank and heat exchanger.

An Effect of Insulated Raft on Longterm Hot Water Storage (Insulated Raft가 장기온수저장에 미치는 영향)

  • Pak, Ee-Tong;Cho, Woon
    • Solar Energy
    • /
    • v.17 no.1
    • /
    • pp.79-91
    • /
    • 1997
  • Thermal energy storage system used a storage tank is a reasonable method to solve energy problem. In thermal energy storage system, energy collected from many types of heat source is stored in a storage tank and then supply to load at the time is in demand. In this study, flow characteristics and storage efficiency were analysed by using a insulated raft in longterm hot water storage system. From the experiment it is found that insulated raft has a important role in longterm hot water storage system and storage efficiency can be obtained to 96% using inletport type and insulated raft together.

  • PDF

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.

A Study on the Optimum Design for a Solar Domestic Hot Water System (小規模 太陽熱 給湯시스템 의 最適設計 에 관한 硏究)

  • 서정일;이영수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.6
    • /
    • pp.517-525
    • /
    • 1984
  • This paper presents a typical solar domestic hot water system and estimates their performances with variance of collector size, storage volume, collector tilt and other factors. The analysis is performed by th computer simulation for which conceptual system against 8760 hourly solar intensities and ambient temperature for a model year stored in the computer has been running. System performance is analyzed on hourly, monthly and yearly basis respectively and at the same time, the economics of various systems are evaluated. And also, this paper shows how an optimized design can be selected for any locality for which solar data and collector performance are provided. The results of this study are as follows. (1)Storage volume of 45 liter per square meter of solar collector lead to the best design. (2)Tilting the collectors to the same angle of the latitude is generally the best (3)Optimal size of collector is approximately 6.68-8.35m$^{2}$ when the latitude is 37.6 .deg. N and storage volume is 300 liter. (4)The performances of a solar domestic hot water system does not depend on the hourly usage but the daily usage.