• Title/Summary/Keyword: Solar Radiation Analysis

Search Result 513, Processing Time 0.028 seconds

Analysis of Passive Cooling Effect of the Tree by Field Observations in the Summer (하절기 단일 수목의 열 환경 관측을 통한 서열완화 효과 해석)

  • Choi, Dong-Ho;Lee, By-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.109-118
    • /
    • 2006
  • The tree is regarded as an sustainable architectural outdoor design element which reduce urban heat island effect by its solar shading and evapotranspiration. This study carried out field observations of measuring thermal environment of selected tree and its ambience to determine passive cooling effects. Results from the field observations are as below; Tree-shading effect to the thermal environment can not be properly evaluated by merely measuring air temperature differences between tree-shaded space and unshaded space for the maximum temperature difference is less than $1.5^{\circ}C$. The differences of longwave radiation and shortwave radiation between tree-shaded space and unshaded space are measured. Shortwave radiation is considered as a main thermal comfort determining factor for the difference of the shortwave radiation is much bigger than that of longwave radiation. By thermal infrared image analysis, the surface temperature of the tree under strong solar radiation is measured same as ambient air temperature. By which the evapotranspiration is considered to retard tree surface temperature raising effectively.

A Study on the Optimization of Color Module BIPV Architectural Design Using BIM - Based on the data of Seoul surveyed solar radiation - (BIM을 활용한 컬러모듈 BIPV 건축 설계 최적화 방안 연구 - 서울 지역 실증 일사량 데이터 중심으로 -)

  • Jeon, Hyun-Woo;Yoon, Hea-Kyung;Park, Suh-Jun
    • Journal of KIBIM
    • /
    • v.9 no.3
    • /
    • pp.19-29
    • /
    • 2019
  • Currently, BIPV (Building Integrated Photovoltaic) design technology lacks analysis function at the planning stage, and there is a lack of understanding and reliability of BIPV design method and system for building designers. To design and consider various building integrated solar design alternatives, the color of building integrated solar is often monotonous or does not match the design direction of the building. In this study, architectural designers can select various color modules in the planning and design process of the building and analyze the characteristics of color module solar cells and compare and analyze the actual solar radiation and predicted solar radiation in Republic ofKorea Seoul to reduce the confusion of design methods. By building a BIM design integrated system that can prove the quality of the building and analyze the shading analysis and power generation performance architecturally, it can improve the reliability of color module solar cell applicability that can express aesthetics in buildings and the predicted solar power generation capacity of each region. In the initial design stage, based on the empirical data of the BIPV system, it is possible to analyze the power generation performance for each installation angle and installation direction by analyzing the surrounding environment and the installation area, and accurately determine the appropriateness of the design accordingly.

Property of CdTe/CdS Solar Cells on Gamma-irradiation (방사선에 대한 CdTe/CdS 태양전지 특성 검토)

  • Kim, Ji-Yoo;Kim, Hwa-Jung;Park, Hae-Jun;Ha, Jang-Ho
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.17-22
    • /
    • 2014
  • In this study, we prepared CdTe/CdS solar cells using a thermal vacuum evaporation method. In particular, $CdCl_2$ treatment was attempted using this same method at $400^{\circ}C$ for 30 min. The prepared CdTe/CdS solar cells were investigated using Fouier transform infrared spectrometry (FTIR), field emission scanning electron microscopy (FE-SEM), and a solar simulator system including light absorption properties, morphological properties, and power conversion efficiency (PCE). In addition, we investigated the gamma-irradiation treatment at dose rates of 0 Gy, 500 Gy, 1 kGy, 10 kGy, and 30 kGy. The characteristics of gamma-irradiation treatment were studied based on the same method described above. In particular, it showed increased values as 0.826% higher than the non-irradiation of 0.448% from PCE analysis.

A Characteristic Analysis of Solar Radiation Resources in Korea (국내 일사량 자원 특성분석)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.413-416
    • /
    • 2009
  • Since the solar radiation is main input for sizing any solar photovoltaic system and solar thermal power system, it will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 and direct normal insolation data since December 1992 at 16 different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar energy system users as well as by research institutes. Among some significant results, the yearly averaged horizontal global insolation was turned out 3.61 kWh/$m^2$/day and the yearly mean 5.38 kWh/$m^2$/day of the direct normal insolation was evaluated for clear days.

  • PDF

A Accuracy Evaluation & Rehabitation of Domestic Solar Insolation Data by Field Measurement (국내(國內) 일사량(日射量) 측정(測定)데이타의 정확도(正確度) 평가(評價) 및 보정(補正))

  • Jo, D.K.;Cho, S.H.;Chea, Y.H.;Auh, P.C.
    • Solar Energy
    • /
    • v.8 no.1
    • /
    • pp.107-121
    • /
    • 1988
  • The Korea Institute of Energy and Resources (KIER) has begun collecting horizental insolation data since May, 1982 at different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by the solar system users as well as by research institutes. But, the quality of the solar radiation data is not always good. This reports on an attempt to identify systematic error in such data using clear-day analysis for data rehabilitation. Clear-day analysis is successful in uncovering solar radiation data of questionable quality. It is not proven that rehabilitation process can improve the quality of data for daily or monthly means but it is suggested that the method can be used to improve the quality of data for monthly means of several years for use in many applications of solar energy planning. Earlier studies finding a maximum ETR of about 0.80 are confirmed.

  • PDF

Modeling Analysis for Thermal Performance of Solar Flat Plate Collector System Through a Year (평판형 태양열 집열기의 연중 열적 성능의 모델링 해석)

  • Kim, Gew Deok;Park, Bae Duck;Kim, Kyoung Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.541-549
    • /
    • 2014
  • The monthly-average meteorological data, in particular, the monthly average daily terrestrial horizontal insolation are required for designing solar thermal energy systems. In this paper, the dynamic thermal performance of a flat plate solar collector system is numerically investigated through a year from the monthly average insolation data in Seoul. For a specified data set of solar collector system, the dynamic behaviors of total solar radiation on the tilted collector surfaces, heat loss from the collector system, useful energy and collector efficiency are analyzed from January to December by a mathematical simulation model. In addition, the monthly average daily total solar radiation, useful energy, and daily collector efficiencies through a year are estimated. The simulated results show that the average total radiation is highest in March and the useful energy is highest in October, while the total radiation and the collector efficiency are lowest in July.

Modal Parameter variation of Steel Cable-stayed Bridge Considering Solar Radiation (일사에 의한 온도변화에 따른 강사장교의 동적특성 변화)

  • Kim Sang-Hyo;Jo Kwang-Il;Park Ju-Yang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.1040-1047
    • /
    • 2006
  • Bridges are exposed to constantly changing weather conditions and temperature. The temperature change is induced by a change in atmospheric temperature and solar radiation. Atmospheric temperature change acts on the whole structure. Thus, it is relatively easy to consider in the design. Solar radiation, however, causes un-uniform temperature distribution in the structure, depending on the shape of the structure and its shadows. Un-uniform temperature distribution causes a torsional moment in bridge section and a deformation of bridge. A deformation can make differences of dynamic and static behavior of bridge. In this study, the method for analysis of static and dynamic behavior considering deformation and changes of material properties due to temperature variation was developed. By this method, it is found from dynamic analysis results that the change of frequency in analysis model is similar with test results of public used cable-stayed bridge. When a temperature goes down, a frequency goes up. And it is found that the change of frequency is affected by the change of material properties.

  • PDF

Relationship between Solar Radiation in Complex Terrains and Shaded Relief Images (복잡지형에서의 일사량과 휘도 간의 관계 구명)

  • Yun, Eun-Jeong;Kim, Dae-Jun;Kim, Jin-Hee;Kang, Dae-Gyoon;Kim, Soo-Ock;Kim, Yongseok
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.4
    • /
    • pp.283-294
    • /
    • 2021
  • Solar radiation is an important meteorological factor in the agricultural sector. The ground exposed to sunlight is highly influenced by the surrounding terrains especially in South Korea where the topology is complex. The solar radiation on an inclined surface is estimated using a solar irradiance correction factor for the slope of the terrain along with the solar radiation on a horizontal surface. However, such an estimation method assumes that there is no barrier in surroundings, which blocks sunlight from the sky. This would result in errors in estimation of solar radiation because the effect of shading caused by the surrounding terrain has not been taken into account sufficiently. In this study, the shading effect was simulated to obtain the brightness value (BV), which was used as a correction factor. The shaded relief images, which were generated using a 30m-resolution digital elevation model (DEM), were used to derive the BVs. These images were also prepared using the position of the sun and the relief of the terrain as inputs. The gridded data where the variation of direct solar radiation was quantified as brightness were obtained. The value of cells in the gridded data ranged from 0 (the darkest value) to 255 (the brightest value). The BV analysis was performed using meteorological observation data at 22 stations installed in study area. The observed insolation was compared with the BV of each point under clear and cloudless condition. It was found that brightness values were significantly correlated with the solar radiation, which confirmed that shading due to terrain could explain the variation in direct solar radiation. Further studies are needed to accurately estimate detailed solar radiation using shaded relief images and brightness values.

Analysis of Solar Radiation and Heat-Efficiency in Semi-Greenhouse Type Solar-Dehumidification Lumber Dryer (반온실형(半溫室型) 제습(除濕).태양열(太陽熱) 목재(木材)드라이어의 일사량(日射量)과 열효율분석(熱效率分析)에 관(關)한 연구(硏究))

  • Lee, Hyoung-Woo
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.3-12
    • /
    • 1989
  • Semi-greenhouse type solar-dehumidification drying of oak was carried out to investigate the possibility to dry wood using solar energy in Korea. The energy balance equation was set up, considering all the energy requirements, and the solar radiation was calculated to analyze the efficiencies of solar dryer with and without the dehumidifier. The average temperature inside dryer and collector rose up to $52^{\circ}C$ and $70^{\circ}C$, respectively. The average daily total beam, diffuse, and ground-reflected radiations were 7.27MJ, 8.70MJ, and 0.33MJ on the roof and 2.08MJ, 4.84MJ, and 5.37MJ on the south wall collector, respectively. Heat efficiency of solar dryer was 14.04% with dehumidifier and 13.13% without dehumidifier. The energy required to remove 1g of water from wood was 0.0289MJ/g in solar-dehumidification drying and 0.0310 MJ/g in semi-greenhouse type solar drying.

  • PDF

Analysis of Cloudiness and Radiation Characteristics during Summer in the Greater Daegu Area (대구지역의 하절기 운량과 장·단파 복사 특성 분석)

  • Baek, Chang-Hyeon;Choi, Dong-Ho;Lee, Bu-Yong;Lee, In-Gyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.13-22
    • /
    • 2017
  • In this study, long and short-wave radiations were observed in urban and suburban areas during the summer season, and frequency analysis was performed for each radiation intensity by a new analysis method. The following results were obtained. (1) Long-wave radiation values were found to be larger in the afternoon than in the morning, in both urban and suburban areas, unlike short-wave radiation values. (2) Short-wave radiation showed a right-skewed frequency distribution. In the high energy area greater than $900W/m^2$, the frequency was significantly higher in the suburbs than in the urban areas. (3) Long-wave radiation was in the range of $290{\sim}479W/m^2$, its frequency distribution resembled a normal distribution, and the frequency of 410, $420W/m^2$ was the highest.