• Title/Summary/Keyword: Solar Measurement

Search Result 582, Processing Time 0.03 seconds

A Study on the Uncertainty Analysis for Thermopile Pyranometer Calibrations (일사계 교정을 위한 불확실성 분석에 관한 연구)

  • Jo, D.K.;Chun, I.S.;Jeon, M.S.;Kang, Y.H.;Auh, C.M.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.3
    • /
    • pp.25-32
    • /
    • 2001
  • The major purpose of this paper is to develop an uncertainty estimate for the calibration of thermopile instruments used to measure solar radiation parameters. We briefly describe the solar radiation parameters most often measured, instrumentation, reference standards, and calibration techniques. The bulk of the paper describes elemental sources of error and their magnitude. We then apply a standard error analysis methodology to combine these elemental error estimates into a statement of total uncertainty for the instrument calibration factor. Our results allow one to evaluate the accuracy of a radiometric measurement using thermopile instrumentation in the light of the application, such as engineering test evaluation or for validation of theoretical models.

  • PDF

3-Component Velocity of Magnetized plasma at Solar Photosphere

  • Jung, Hyewon;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.70.3-70.3
    • /
    • 2019
  • We present a method to estimate 3-component plasma velocity (Vx, Vy and Vz) at solar photosphere near solar disk center, using the Helioseismic and Magnetic Imager (HMI) onboard the Solar Dynamics Observatory (SDO) called Space-weather HMI Active Region Patch (SHARP). In Heliocentric-Cartesian Coordinates, the component of Vz is obtained from Dopplergram while the components of Vx and Vy are derived from the relation of $B_z{\overrightarrow{u}}=B_z{\overrightarrow{{\nu}_t}}-{\nu}_z{\overrightarrow{B_t}}$ (Demoulin & Berger 2003) using a series of vector magnetograms by an optical flow technique NAVE (Nonlinear Affine Velocity Estimator). This velocity measurement method is applied to AR 12158 producing an X1.6 flare along with a coronal mass ejection. We find noticeable upflow motions at both ends of flux ropes which become a major eruption part, and strong transverse motions nearby them before the eruption. We will discuss the change of plasma motions and magnetic fields before and after the eruption.

  • PDF

The Study on the Energy self-sufficiency and Economic Analysis of KIER Zero Energy Solar House (제로에너지 솔라하우스(KIER ZeSH)의 에너지 자립도 및 경제성 분석)

  • Jeong, Seonyeong;Baek, Namchoon;Yoo, Changkyoon;Yoon, Eungsang;Yoon, Jongho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.64.1-64.1
    • /
    • 2010
  • In this study, the energy and economic analysis of KIER Zero Energy Solar House (KIER ZeSH) was carried out. KIER ZeSH was designed and constructed in the end of 2009 for the purpose of more than 70% energy self-sufficiency in total load as well as less than 20% of additional construction cost. The several building energy conservation technologies like as super insulation, high performance window, wast heat recovery system, etc and renewable energy system. The renewable heating and cooling system is a kind of solar thermal system combined with geo-source heat pump as a back-up device. The capacity of 3.15kW solar BIPV system was also installed on the roof. The measurement by monitering system of ZeSH was conducted for one year from November 2009 to October 2010. The energy self-sufficiency and economic analysis were conducted based on the this monitering result. As a result, the energy self sufficiency is about 83% which is higher than that of the target and the payback period is 11 years.

  • PDF

Improved Efficiency by Insertion of TiO2 Interfacial Layer in the Bilayer Solar Cells

  • Xie, Lin;Yoon, Soyeon;Kim, Kyungkon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.432.1-432.1
    • /
    • 2016
  • We demonstrated that the power conversion efficiency (PCE) of bilayer solar cell was significantly enhanced by inserting interfacial layer between the organic bilayer film and the Al electrode. Moreover, the water contact angle shows that the bilayer solar cells suffer from the undesirable surface component which limits the charge transport to the Al electrode. The AFM measurement has revealed that the pre- and post-thermal annealing treatments results in different morphologies of the interfacial layer which is critical for the higher PCE of the bilayer solar cells. Furthermore we have investigated the electrical properties of the bilayer solar cells and obtained insights into the detailed device mechanisms. The transient photovoltage measurements suggests that the significantly enhanced Voc is caused by reducing the recombination at the interface between the organic films and the Al electrode. By inserting the TiO2 layer between the bilayer film and Al electrode, the open circuit voltage (Voc) was increased from 0.37 to 0.66V. Consequently, the power conversion efficiency (PCE) of bilayer solar cells was significantly enhanced from 1.23% to 3.71%. As the results, the TiO2 interfacial layer can be used to form an ohmic contact layer, serveing as a blocking layer to prevent the penetration of the Al, and to reduce the recombination at the interface.

  • PDF

Space Radiation Measurement on the Polar Route onboard the Korean Commercial Flights

  • Hwang, Jung-A;Lee, Jae-Jin;Cho, Kyung-Suk;Choi, Ho-Sung;Rho, Su-Ryun;Cho, Il-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.1
    • /
    • pp.43-54
    • /
    • 2010
  • This study was performed by the policy research project of Ministry of Land, Transport and Maritime Affairs, which title is "Developing safety standards and management of space radiation on the polar route". In this research, total six experiments were performed using Korean commercial flights (B747). Three of those are on the polar route and the other three are on the north pacific route. Space radiation exposure measured on the polar route is the average 84.7 uSv. The simulation result using CARI-6M program gives 84.9 uSv, which is very similar to measured value. For the departure flight using the north pacific route, the measured space radiation is the average 74.4 uSv. It seems that is not so different to use the polar route or not for the return flight because the higher latitude effect causing the increase of space radiation is compensated by the shortened flight time effect causing decreasing space radiation exposure.

A Detailed Survey on the Solar Availability for the Construction of Photovoltaic Power Generation Sites (태양광발전단지 건설을 위한 태양광자원 정밀조사)

  • Jo, Dok-Ki;Kang, Young-Heack;Lee, Euy-Joon;Auh, Chung-Moo
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.83-88
    • /
    • 2004
  • Since the solar radiation is the main input for sizing any solar photovoltaic system, it will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar photovoltaic system users as well as by research institutes From the results, we can conclude that 1) The yearly averaged horizontal global insolation of Korea was turned out $3.57kWh/m^2.day$ in the periods of $1982\sim2001$. 2) Horizontal global insolation of spring and summer was respectively 24 % and 21 % higher than the yearly average value, and that of fall and winter was respectively 12 % and 34 % lower than the yearly average value.

Characteristics analysis of Residential 3kW PV System (주택용 3kW 태양광발전시스템의 구성요소법 특성 분석)

  • Bian, W.J.;Piao, Z.G.;Lim, H.W.;Lee, K.Y.;Cho, G.B.;Baek, H.L.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1181-1182
    • /
    • 2006
  • The solar power system comprises a solar battery that directly converts light energy to electrical energy with a photovoltaic effect and a power converter system, that is, inverter that converts direct current power, which is generated from solar battery to common alternating current. In this paper, database was constituted through remote monitoring supervision measurement for the long-time positive operation of 3kW solar power system installed within the solar energy positive research complex of Chosun University. As a result of analyzing the reduction of the efficiency of solar battery and inverter that are compositional components of PV system through an analysis on the acquired data, the PV output was proven over 65% of the total output when insolation intensity exceeded 600W/m2 in 2005, and the array conversion efficiency dropped much more than rating; meanwhile, insolation intensity dropped below 600W/m2. Therefore, it has been demonstrated that approximately 35% of the entire amount of PV output operated under the condition that the inverter efficiency rate dropped rapidly by 60 to 70%.

  • PDF

Improve the Efficiency of Hybrid Solar LED Street Lamp Controller (하이브리드 태양광 LED 가로등 컨트롤러의 효율 개선)

  • Yun, Jung-Hyun;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.131-136
    • /
    • 2015
  • We develop the 60 W class hybrid solar LED street lamp controller. The controller is providing power via an inverter in the day with the least solar cell and battery and charging the battery for the ESS, acts as a power failure, the built-in battery. Rated output of the fabricated LED street lamp is 300 W or greater battery capacity 300 Wh, discharge time 10 hr, LED street lamp efficiency showed a very high level of light efficiency by about 127 lm/W. In addition, as a result of light distribution pattern according to the distance and the light intensity measurement will be able to ensure a very high quality, show the constant brightness in the distance from the road lights 6 m is about 35~40 lux in uniformity ratio. The proposed hybrid solar LED street lamp system showed a high energy capacity of approximately 1.5 to 152.7% power generation efficiency than typical conventional solar street lamp.

A Study on Accuracy Evaluation of Horizontal Global Radiation Data in Korea (국내 수평면 전일사량 데이터의 정확도 평가에 관한 연구)

  • Jo, D.K.;Chun, I.S.;Lee, T.K.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.31-43
    • /
    • 2000
  • The Korea Institute of Energy Research(KIER) has been collecting horizontal global radiation data since May, 1982 for 16 different locations. KIER's new data is expected to be extensively used by designer and researchers of solar systems in lieu of unreliable old ones. Unfortunately, the quality of the data has not always been properly mentioned. Some of them were taken at temporary field stations where the primary goal of the measurement was quick estimation of local solar radiation. The purpose of this study is to systematically identify errors in such data set using clear-day analysis in an effort to rehabilitate error-ridden old data. Clear-day analysis successfully uncovered solar radiation data that had questionable quality. Even through the rehabilitation process not necessarily improves the quality of data for daily or monthly mean, it can be used to improve the quality of data for monthly means of several years and the processed data can be used in various applications of solar energy with more confidence. A average ETR value of 0.63 obtained in this study is in good agreement with previous results obtained by other researchers.

  • PDF

Fabrication and Characteristics of $n-CdS_{0.69}Se_{0.31}/p-Cu_{2-x}S_{0.69}Se_{0.31}$ Heterojunction Solar Cell ($n-CdS_{0.69}Se_{0.31}/p-Cu_{2-x}S_{0.69}Se_{0.31}$ Heterojunction 태양전지의 제작과 특성)

  • Baek, Seung-Nam;Hong, Kwang-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.51-55
    • /
    • 2004
  • $CdS_{0.69}Se_{0.31}$ single crystal grown by sublimation method. Hall effect measurement were carried out by the Van der Pauw method. The measurement values under the temperature were found to be carrier density $n=1.95{\times}10^{23}m^{-3}$, Hall coeffcient $RH=3.21{\times}10^{-5}m^3/c$, conductivity ${\sigma}=362.41{\Omega}^{-1}m^{-1}$, and Hall mobility ${\mu}=1.16{\times}10^{-2}m^2/v.s.$ Heterojunction solar cells of $n-CdS_{0.69}Se_{0.31}/p-Cu_{2-x}S_{0.69}Se_{0.31}$ were fabricated by the substitution reaction. The open-circuit voltage, short-circuit currint density, fill factor and power conversion efficiency of $n-CdS_{0.69}Se_{0.31}/p-Cu_{2-x}S_{0.69}Se_{0.31}$ heterojunction solar cell under $80mW/cm^2$ illumination were found to be 0.41V, $19.5mA/cm^2$, 0.75 and 9.99%, respectivity.

  • PDF