• Title/Summary/Keyword: Solar Measurement

Search Result 582, Processing Time 0.024 seconds

A Study of Zero Energy Building Verification with Measuring and Model-based Simulation in Exhibition Building

  • Ha, Ju-wan;Park, Kyung-soon;Kim, Hwan-yong;Song, Young-hak
    • Architectural research
    • /
    • v.20 no.3
    • /
    • pp.93-102
    • /
    • 2018
  • With the change in Earth's ecosystems due to climate change, a number of studies on zero energy buildings have been conducted globally, due to the depletion of energy and resources. However, most studies have concentrated on residential and office buildings and the performance predictions were made only in the design phase. This study verifies the zero-energy performance in the operational phase by acquiring and analyzing data after the completion of an exhibition building. This building was a retention building, in which a renewable energy system using a passive house building envelope, solar photovoltaic power generation panels, as well as fuel cells were adopted to minimize the maintenance cost for future energy-zero operations. In addition, the energy performance of the building was predicted through prior simulations, and this was compared with actual measured values to evaluate the energy performance of the actual operational records quantitatively. The energy independence rate during the measurement period of the target building was 123% and the carbon reduction due to the energy production on the site was 408.07 tons. The carbon reduction exceeded the carbon emission (331.5 tons), which verified the carbon zero and zero-energy performances.

MEASUREMENT AND SIMULATION OF EQUATORIAL IONOSPHERIC PLASMA BUBBLES TO ASSESS THEIR IMPACT ON GNSS PERFORMANCE

  • Tsujii, Toshiaki;Fujiwara, Takeshi;Kubota, Tetsunari;Satirapod, Chalermchon;Supnithi, Pornchai;Tsugawa, Takuya;Lee, Hungkyu
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.6_2
    • /
    • pp.607-613
    • /
    • 2012
  • Ionospheric anomaly is one of the major error sources which deteriorate the GNSS performance. In the equatorial region, effects of the ionospheric plasma bubbles are of great interest because they are pretty common phenomena, especially in the period of the high solar activity. In order to evaluate the GNSS performance under circumstance of the bubbles, an ionospheric scintillation monitor has been developed and installed in Bangkok, Thailand. Furthermore, a model simulating the ionospheric delay and scintillation due to the bubbles has been developed. Based on these developments, the effects of the simulated plasma bubbles are analyzed and their agreement with the real observation is demonstrated. An availability degradation of the GPS ground based augmentation system (GBAS) caused by the bubbles is exampled in details. Finally, an integrated GPS/INS approach based on the Doppler frequency is proposed to remedy the deterioration.

A Study on the Electrical Properties of ITO Thin Films with Various Oxygen Gas Flow Rate (산소 가스 유량비 변화에 따른 ITO 박막의 전기적 특성에 관한 연구)

  • Choi, Dong-H.;Keum, Min-J.;Jean, A.R.;Han, Jean-G.
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.3
    • /
    • pp.144-148
    • /
    • 2007
  • To prepare the transparent electrode for electronic devices such as flat panel or flexible displays, solar cells, and touch panels; tin doped $In_2O_3$ (ITO) films with low resistivity and a high transparency were fabricated using a facing target sputtering (FTS) system at the various oxygen gas flow rate. The carrier concentration and mobility of ITO films were measured by Hall Effect measurement. And the transmittance was measured using the UV-VIS spectrometer. As a result, we can obtain the ITO thin films prepared at 10% oxygen gas flow ratio, thickness 150 nm with transmittance 85% and resistivity $8.1{\times}10^{-4}{\Omega}cm$ and surface roughness 5.01 nm.

DEVELOPMENT OF SEMI-VLBI SYSTEM AND OBSERVATION OF SUN AT 21 cm

  • Park Yong-Sun;Kang Hyun-Woo;Kim Hyo-Uk;Kang Heui-Jeong;Jee Myeong-Keun;Lee Sul-Gi;Ahn Jung-Hyun;Kim Jin-Su;Shin Young-Soo;Kang Song-Hun
    • Journal of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.51-56
    • /
    • 2006
  • We report the development of a semi-VLBI observation system operating at 21 cm and present the measurement of visibility function toward the sun using this system. The system consists of two 2.3 meter antennas with a maximum separation of 35 meter, a conventional high speed data acquisition system, and a set of programs for software correlation. Since two local oscillators of receiver modules are independent, data had to be fringe-fitted to yield the visibility amplitude. It is found that the visibility amplitude decreases and then bounces back as baseline increases. We confirm that solar disk with brighter limb best explains the measured visibility amplitude.

Study on Characteristics of Radiation Environment in the Urban through the Field Observation in the Summer (하절기 도시의 장.단파 복사특성 관측)

  • Jung, Im-Soo;Choi, Dong-Ho;Lee, Bu-Yong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.105-110
    • /
    • 2011
  • The objective of this study is to analyze the characteristic of radiation environment in the urban and rural through the field observation in the summer. The radiation balance was compared through the measurement of the shortwave radiation and long-wave radiation in the urban, sub-urban, and rural. The following conclusion could be obtained from this research. (1) In the results of observation including the rain-day, it was found that the short wave radiance in the urban is lower about 10% than the rural. (2) The upper part of atmosphere layers in the urban area absorb much short wave radiation energies compared with the rural relatively. It can increase the temperature of the upper part of atmosphere layers and the emittance of long wave radiation. (3) The ratio of the downward short wave radiation to the downward long wave radiation was 1.24 for the urban, 1.28 for sub-urban and1.35 for rural. It can be estimated that the atmosphere condition of the rural is better than that of other areas.

  • PDF

The Study on the Thermal Comfort of Rural Housing in Chung-nam area (충남지역 농촌 주거용 건물의 열쾌적성능에 관한 연구)

  • Park, Jae-Sang;Yoo, Jong-Ho;Park, Jae-Wan;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.202-207
    • /
    • 2011
  • This study has measured indoor temperature and relative humidity and evaluated it for one year by selecting Chungnam's rural areas for improving indoor environment of rural housing in the circumstance that the environment of housing is poor due to deterioration of rural housing. As a result of its evaluation, the indoor temperature difference by household appeared to be more than $13^{\circ}C$, and it was measured that the indoor temperature was mostly low. A difference of more than 40% in case of relative humidity occurred, so the difference of the indoor environment by household was clear. In case of the thermal comfort zone, the number of households that are distributed to more than 50% of a thermal comfort criterion in the winter was only 3 households, rather than the summer.

  • PDF

Design and Verification of Advanced Distribution Management System using Information and Communication Convergence Technology (ICT융복합 기술을 이용한 차세대 배전계통 운영 시스템 설계 및 검증)

  • Kim, Dongwook;Park, Youngbae;Chu, Cheolmin;Jo, Sungho;Seo, Inyong
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.4
    • /
    • pp.19-29
    • /
    • 2019
  • Recently, with the rise of environmental issues and the change of government policy (Renewable Energy 3020 Implementation Plan), a large amount of renewable energy such as solar and wind power is connected to the power system, and most of the renewable energy is concentrated in the power distribution network. This causes many problems with the voltage management and the protection coordination of the grid due to the its intermittent power generation. In order to effectively operate the distribution network, it is necessary to deploy more intelligent terminal devices in the field to measure the status of the distribution network and develop various operation functions such as visualization and big data analysis to support the power distribution system operators. In addition, the failover technology must be supported for the non-stop operation of the power distribution system. This paper proposes the system architecture of new power distribution management system to cope with high penetration of renewable energy. To verify the proposed system architecture, the functional unit test and performance measurement were performed.

Experimental Investigation on High Efficient Electrolytes of Electrochemical Photovoltaic Cells (전기화학형 광전변환 셀의 고효율 전해질 제작에 관한 실험적 고찰)

  • Kim, Doo-Hwan;Han, Chi-Hwan;Sung, Youl-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.100-104
    • /
    • 2011
  • In this work, an optimum condition of electrolytes preparation for photovoltaic cells application was investigated experimentally in terms of impedance and conversion efficiency of the cells. 3-methoxyppropionitrie and redox pairs with LiI and $I_2$ were used as stable solvents for fabrication of electrolyte. Efficiency comparison of the prepared cells carried out for various additives and ionic liquids. From the results, there was an optimum concentration (about 0.3 M) of ionic liquids for efficient cell fabrication. For case of electrolyte using single DMAp additive, the maximum conversion efficiency of the cell was 6.4%($V_{oc}$: 0.78V, $J_{sc}$: 14.4 mA/$cm^2$, ff: 0.57). For case of electrolyte using both DMAp and CEMim additives, the maximum conversion efficiency of the cell was 7.2%($V_{oc}$: 0.79V, $J_{sc}$: 16 mA/$cm^2$, ff: 0.57). From the result of electrochemical impedance measurement, both Z1 and Z3 values of binary additives-based cell decreased compared to those of single additive-based. This is due to the decreased in internal and charge transfer resistivities of the cells.

Numerical Simulation of the Flow Patterns with Sloping Forest Canopies (경사진 산림지형에서의 자연유동에 대한 수치해석)

  • Yoon, Hyun-Gi;Stock, David E.;Yoo, Ki-Soo;Chung, Myung-Kyoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.3
    • /
    • pp.173-180
    • /
    • 2008
  • Diurnal variation of the flow over a forest canopy on a mountain slope is simulated numerically. In the daytime, the earth surface is heated by the solar radiation and the flow goes up the mountain due to the buoyancy force, and during the night, the air is drained downward along the slope owing to the cooling of the surface by radiation. In this flow process the forest canopy that consists of leaf region and the trunk region plays a dominant role as a momentum sink to the flow, thus the modeling of the leaf area region and trunk region is critical to the successful flow simulation. In the present study, a field measurement in an experimental forest in the State of Oregon in the United States is numerically analyzed. The resistance to the flow in the leaf region is directly related to the leaf area density (LAD), and the trunk is modeled as a cylinder.

Analysis of COMS In-Orbit Test for Moment of Inertia Measurement (천리안위성 관성모멘트의 궤도상 측정 시험 분석)

  • Park, Keun-Joo;Park, Young-Woong;Choi, Hong-Taek
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.121-127
    • /
    • 2011
  • In the attitude and orbit control subsystem design, the moment of inertia of the satellite is the major contributor to be considered. Satellites equipped with large solar arrays need to measure the moment of inertia accurately to avoid the interference of the thruster actuation period with its flexible mode. In this paper, the in-orbit tests of COMS to measure the moment of inertia are described. Then, the differences between the measured through in-orbit test and the predicted are compared. Finally, it is verified that the differences are below uncertainty bounds considered in the critical design of COMS attitude and orbit control subsystem.