• 제목/요약/키워드: Solar Measurement

검색결과 582건 처리시간 0.023초

PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

태양광 패널 재사용을 위한 가변 정전류 기반의 효율 측정장치에 관한 연구 (Research on Variable Constant Current Efficiency Measuring Device for Solar Panel to Reuse)

  • 우상진;김대헌;이재진;권오민
    • 대한임베디드공학회논문지
    • /
    • 제18권1호
    • /
    • pp.9-17
    • /
    • 2023
  • This paper relates to the development of a device for measuring the efficiency of a solar panel based on a variable constant current, and proposed a standard for reuse of the solar panel. By applying a variable constant current circuit to a solar panel efficiency measuring device, it was easy to apply a maximum power point tracking (MPPT) algorithm. In addition, a load dispersion method was applied to measure the efficiency of a high-capacity solar panel. and it is possible to solve a problematic thermal runaway during a MOSFET parallel operation by applying the load dispersion method. As a result of the experiment, the solar panel efficiency measuring device was able to accommodate a large solar panel of 350W, which is the maximum measurement goal. In this paper, the validity was confirmed through the 310W solar panel efficiency measurement experiment collected after removal.

cds 광전소자(光電素子)를 이용한 인공태양(人工太陽) 일사강도(日射强度)의 동시측정(同時測定) (One-time measurement of irradiation intensity of Solar Simulator using cds photo-sensors)

  • 배강;조서현;이보호;오정무
    • 태양에너지
    • /
    • 제5권2호
    • /
    • pp.28-34
    • /
    • 1985
  • There are two kinds of irradiation intensity deviation, depending on time and position, on illuminated plane when thermal performance of solar collector is tested by using solar simulator. In this study we measured only position deviation of irradiation intensity using 45-cds photosensors and data acqusition system and found the point of average value. By this result we can improve the accuracy of irradiation measurement in indoor test of solar collector.

  • PDF

PV모듈의 I-V특성 시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test)

  • 강기환;박지홍;김경수;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.5-7
    • /
    • 2006
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.75W$ with 95% confidence level for 125W PV module.

  • PDF

타워형 태양열발전을 위한 열유속 분포 측정기술 개발 (Development of Flux Mapping Technique for the Solar Power Tower Plant)

  • 채관교;이현진;김종규;윤환기;이상남;강용혁;서태범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.274-279
    • /
    • 2012
  • Daegu Solar Power Tower Plant of 200 kW thermal capacity was developed for the first time in Korea, 2011. Measurement of the heat flux distribution is essential to evaluate the solar energy concentrated by reflectors and to design a suitable receiver. The flux mapping technique, which uses a radiometer and a diffuse plate, is common for measurement of the heat flux distribution. Because the solar power tower plant has a wide concentration area, the flux mapping technique using a fixed diffuse plate is difficult to apply. Therefore, the flux distribution in the solar power tower plant should be measured by the flux mapping technique using a small moving bar. In this study, we measured flux distributions with the moving-bar system developed at the KIER solar furnace and evaluated its applicability for the solar power tower plant.

  • PDF

TRY 방법론에 의한 표준일사량데이터 평가 (Evaluation of Typical Solar Radiation Data by the TRY Methodology)

  • 유호천;이관호;김경률;박소희
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.23-28
    • /
    • 2007
  • Limited fossil fuels and unstable energy supply are considered as one of the critical problems in architecture requiring large amounts of energy. In order to this challenge, environment-friendly architecture design is required. Clear data should be prepared to apply solar energy to architecture aggressively and properly. This study used FS statistical analysis data regarding average daily solar radiation of Seoul observed over 20 years to find out standard year and standard daily solar radiation. This study also aims to compare and evaluate an appropriate method of selecting a standard year which is too close to measurement value through comparison and analysis with daily solar radiation acquired by applying overseas researchers' suggesting weight factor. As a result, the data nearest to measurement value of daily solar radiation was UK CIBSE TRY(TYPE 2) displaying 0.100in t-statistic index. For UK CIBSE TRY(TYPE 2), weight factor was applied to three climatic elements except relative humidity. TYPE 1 and TYPE 3 recorded 0.343 and 0.367, respectively, showing higher record of t-statistic than TYPE 2. TYPE 1 was calculated through FS statistical value of single data about daily solar radiation with other climatic elements excluded. For TYPE 3, relative humidity was added to TYPE 2. In particular, since TYPE 2 was closer to the measurement value compared to the others, it is necessary to consider relationship with other climate elements if other climate elements are added.

태양전지의 효율측정 (Characterization ion of Solar Cells)

  • 조영현;조은철;이수홍
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 춘계학술대회 논문집
    • /
    • pp.163-166
    • /
    • 1995
  • A solar cell I-V (current-voltage) characteristic measurement facility is crucial, for the characteristic of solar cells, The solar cell I-v tester has been designed and fabricated to characterize the solar cell at SAIT.

  • PDF

고효율 태양전지모듈의 성능측정 방법 (Performance Measurement Method of Several Types of Photovoltaic Module Depending on Efficiency)

  • 김경수;강기환;유권종;윤순길
    • 한국태양에너지학회 논문집
    • /
    • 제31권1호
    • /
    • pp.93-99
    • /
    • 2011
  • To guarantee more exact maximum power of solar cell module, it is absolutely required to have performance characteristics of various solar cells. Today, there are many types of solar simulator for large area measurement. But it is very opaque how to select the best one for various solar cell module like crystalline silicon solar cell, high efficiency solar cell, amorphous silicon thin film solar cell, CdTe and CIGS solar cell module. So, in this paper 4 types of photovoltaic module were selected to compare the electrical characteristics by changing light pulse duration time and voltage scan direction. Light pulse duration time was varied from 10msec to 800msec. And two types of voltage scan directions, Voc->Isc and Isc->Voc were selected. From this results, optimum measuring condition was suggested and electrical variation was analysed for each types of solar cell module. The detail description is specified as the following paper.

태양전지의 양자효율 측정 및 분석 (Quantum Efficiency Measurement and Analysis of Solar Cells)

  • 김영국;오동현;박진주;이준신
    • 한국전기전자재료학회논문지
    • /
    • 제36권4호
    • /
    • pp.351-361
    • /
    • 2023
  • 본 논문은 대학연구실과 산업현장에서 태양전지를 연구 개발하는 초년생들이 태양전지 성능 분석하는 데 있어 가장 기본적이면서도 중요한 양자효율(quantum efficiency) 측정, 분석 방법에 이해를 돕는 것을 목적으로 한다. 양자효율의 정의를 시작으로, 측정 방법, 분석 방법에 대한 자세한 소개와 함께 태양광 스펙트럼으로부터 태양전지 소재의 밴드 갭에 따른 이론적인 전류밀도를 계산하고, 이론적인 전류밀도와 양자효율 측정, 분석을 통해 태양전지의 성능을 분석하는 방법에 대해 깊이 있게 논의한다. 태양전지의 양자효율 측정 분석은 태양전지를 깊이(전면, bulk, 후면)에 따라 분석할 수 있어 태양전지 성능 분석에 직관을 줄 수 있는 매우 유용한 방법이다. 이론적 전류밀도와 양자효율 측정 분석에 대한 깊은 이해로 태양전지를 연구하는 학생과 연구원들이 태양전지의 성능 분석을 하는 데 있어 기반으로 활용할 수 있기를 기대한다.

KIER 태양로의 열유속 분포 특성 (Characteristic of the Radiation Heat Flux Distribution for the KIER Solar Furnace)

  • 채관교;이현진;김종규;윤환기;이상남;강용혁;서태범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.74-79
    • /
    • 2011
  • Concentration characteristics of the KIER solar furnace are analyzed with a heat flux measurement technique. Total heat capacity of 40kW was confirmed within 1.04% average error, and the normalized maximum heat flux of 3,452 $kW/m^2$ was proved. Non-Gaussian flux distribution in the vertical direction implies that reflectors should not be random rather inclined downwards. Moreover, we characterized flux distribution variations with furnace blind opening ratio, distance from the focal plane, and misalignment of the measurement system. Based on the results, the heat flux distribution can be simply estimated once reflectivity and direct normal insolation values are known. This study will be helpful to the design and the performance evaluation of receivers or chemical reactors.

  • PDF