• Title/Summary/Keyword: Solar Measurement

Search Result 582, Processing Time 0.024 seconds

Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module (PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

Research on Variable Constant Current Efficiency Measuring Device for Solar Panel to Reuse (태양광 패널 재사용을 위한 가변 정전류 기반의 효율 측정장치에 관한 연구)

  • Sang-Jin Woo;Dae-Heon Kim;Jae-Jin Lee;Oh-Min Kwon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.18 no.1
    • /
    • pp.9-17
    • /
    • 2023
  • This paper relates to the development of a device for measuring the efficiency of a solar panel based on a variable constant current, and proposed a standard for reuse of the solar panel. By applying a variable constant current circuit to a solar panel efficiency measuring device, it was easy to apply a maximum power point tracking (MPPT) algorithm. In addition, a load dispersion method was applied to measure the efficiency of a high-capacity solar panel. and it is possible to solve a problematic thermal runaway during a MOSFET parallel operation by applying the load dispersion method. As a result of the experiment, the solar panel efficiency measuring device was able to accommodate a large solar panel of 350W, which is the maximum measurement goal. In this paper, the validity was confirmed through the 310W solar panel efficiency measurement experiment collected after removal.

One-time measurement of irradiation intensity of Solar Simulator using cds photo-sensors (cds 광전소자(光電素子)를 이용한 인공태양(人工太陽) 일사강도(日射强度)의 동시측정(同時測定))

  • Bai, K.;Cho, S.H.;Lee, N.H.;Auh, P.C.M.
    • Solar Energy
    • /
    • v.5 no.2
    • /
    • pp.28-34
    • /
    • 1985
  • There are two kinds of irradiation intensity deviation, depending on time and position, on illuminated plane when thermal performance of solar collector is tested by using solar simulator. In this study we measured only position deviation of irradiation intensity using 45-cds photosensors and data acqusition system and found the point of average value. By this result we can improve the accuracy of irradiation measurement in indoor test of solar collector.

  • PDF

Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test (PV모듈의 I-V특성 시험을 위한 Solar Simulator의 측정불확도 요인 분석)

  • Kang, Gi-Hwan;Park, Chi-Hong;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.5-7
    • /
    • 2006
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.75W$ with 95% confidence level for 125W PV module.

  • PDF

Development of Flux Mapping Technique for the Solar Power Tower Plant (타워형 태양열발전을 위한 열유속 분포 측정기술 개발)

  • Chai, Kwan-Kyo;Lee, Hyun-Jin;Kim, Jong-Kyu;Yoon, Hwan-Ki;Lee, Sang-Nam;Kang, Yong-Heack;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.274-279
    • /
    • 2012
  • Daegu Solar Power Tower Plant of 200 kW thermal capacity was developed for the first time in Korea, 2011. Measurement of the heat flux distribution is essential to evaluate the solar energy concentrated by reflectors and to design a suitable receiver. The flux mapping technique, which uses a radiometer and a diffuse plate, is common for measurement of the heat flux distribution. Because the solar power tower plant has a wide concentration area, the flux mapping technique using a fixed diffuse plate is difficult to apply. Therefore, the flux distribution in the solar power tower plant should be measured by the flux mapping technique using a small moving bar. In this study, we measured flux distributions with the moving-bar system developed at the KIER solar furnace and evaluated its applicability for the solar power tower plant.

  • PDF

Evaluation of Typical Solar Radiation Data by the TRY Methodology (TRY 방법론에 의한 표준일사량데이터 평가)

  • Yoo, Ho-Chun;Lee, Gwan-Ho;Kim, Kyoung-Ryul;Park, So-Hee
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.23-28
    • /
    • 2007
  • Limited fossil fuels and unstable energy supply are considered as one of the critical problems in architecture requiring large amounts of energy. In order to this challenge, environment-friendly architecture design is required. Clear data should be prepared to apply solar energy to architecture aggressively and properly. This study used FS statistical analysis data regarding average daily solar radiation of Seoul observed over 20 years to find out standard year and standard daily solar radiation. This study also aims to compare and evaluate an appropriate method of selecting a standard year which is too close to measurement value through comparison and analysis with daily solar radiation acquired by applying overseas researchers' suggesting weight factor. As a result, the data nearest to measurement value of daily solar radiation was UK CIBSE TRY(TYPE 2) displaying 0.100in t-statistic index. For UK CIBSE TRY(TYPE 2), weight factor was applied to three climatic elements except relative humidity. TYPE 1 and TYPE 3 recorded 0.343 and 0.367, respectively, showing higher record of t-statistic than TYPE 2. TYPE 1 was calculated through FS statistical value of single data about daily solar radiation with other climatic elements excluded. For TYPE 3, relative humidity was added to TYPE 2. In particular, since TYPE 2 was closer to the measurement value compared to the others, it is necessary to consider relationship with other climate elements if other climate elements are added.

Characterization ion of Solar Cells (태양전지의 효율측정)

  • 조영현;조은철;이수홍
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.163-166
    • /
    • 1995
  • A solar cell I-V (current-voltage) characteristic measurement facility is crucial, for the characteristic of solar cells, The solar cell I-v tester has been designed and fabricated to characterize the solar cell at SAIT.

  • PDF

Performance Measurement Method of Several Types of Photovoltaic Module Depending on Efficiency (고효율 태양전지모듈의 성능측정 방법)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Yoon, Soon-Gil
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.93-99
    • /
    • 2011
  • To guarantee more exact maximum power of solar cell module, it is absolutely required to have performance characteristics of various solar cells. Today, there are many types of solar simulator for large area measurement. But it is very opaque how to select the best one for various solar cell module like crystalline silicon solar cell, high efficiency solar cell, amorphous silicon thin film solar cell, CdTe and CIGS solar cell module. So, in this paper 4 types of photovoltaic module were selected to compare the electrical characteristics by changing light pulse duration time and voltage scan direction. Light pulse duration time was varied from 10msec to 800msec. And two types of voltage scan directions, Voc->Isc and Isc->Voc were selected. From this results, optimum measuring condition was suggested and electrical variation was analysed for each types of solar cell module. The detail description is specified as the following paper.

Quantum Efficiency Measurement and Analysis of Solar Cells (태양전지의 양자효율 측정 및 분석)

  • Youngkuk Kim;Donghyun Oh;Jinjoo Park;Junsin Yi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.4
    • /
    • pp.351-361
    • /
    • 2023
  • The purpose of this paper is to help those who research and develop solar cells in university laboratories and industrial sites understand the most basic and important quantum efficiency measurement and analysis method in analyzing solar cell performance. Starting with the definition of quantum efficiency, we calculate the theoretical current density according to the band gap of the solar cell material from the solar spectrum, along with a detailed introduction to the measurement and analysis methods, and measure and analyze the theoretical current density and quantum efficiency. We discuss in depth how to analyze the performance of solar cells through Quantum efficiency measurement and analysis of solar cells is a very useful method that can give intuition to solar cell performance analysis as it can analyze solar cells according to depth (front emitter, bulk, rear surface). Students and researchers who study solar cells with a deep understanding of theoretical current density and quantum efficiency measurement analysis are expected to use it as a basis for analyzing solar cell performance.

Characteristic of the Radiation Heat Flux Distribution for the KIER Solar Furnace (KIER 태양로의 열유속 분포 특성)

  • Chai, Kwan-Kyo;Lee, Hyun-Jin;Kim, Jong-Kyu;Yoon, Hwan-Ki;Lee, Sang-Nam;Kang, Yong-Heack;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.74-79
    • /
    • 2011
  • Concentration characteristics of the KIER solar furnace are analyzed with a heat flux measurement technique. Total heat capacity of 40kW was confirmed within 1.04% average error, and the normalized maximum heat flux of 3,452 $kW/m^2$ was proved. Non-Gaussian flux distribution in the vertical direction implies that reflectors should not be random rather inclined downwards. Moreover, we characterized flux distribution variations with furnace blind opening ratio, distance from the focal plane, and misalignment of the measurement system. Based on the results, the heat flux distribution can be simply estimated once reflectivity and direct normal insolation values are known. This study will be helpful to the design and the performance evaluation of receivers or chemical reactors.

  • PDF