• Title/Summary/Keyword: Solar Energy Utilization

검색결과 211건 처리시간 0.032초

독립형 DC 마이크로그리드의 최적화 설계와 협조적 제어 (Optimized Design and Coordinated Control for Stand-alone DC Micro-grid)

  • 한태희;이지헌;김현준;한병문
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.63-71
    • /
    • 2013
  • This paper describes the coordinated droop control method for stand-alone type DC micro-grid to improve reliability and utilization of distributed generations and energy storage. The stand-alone type DC micro-grid consists of several distributed generations such as a wind power generation, solar power and micro-turbine, and energy storage. The proposed method which is based on autonomous control method shows high reliability and stability through coordinated droop control of distributed generations and energy storage and also capability of battery management. The operation of stand-alone type DC micro-grid was analyzed using detail simulation model with PSCAD/EMTDC software. Based on simulation results, a hardware simulator was built and tested with commercially available components and performance of system was verified.

한국형 지열발전 타당성 연구 (A Feasibility Study on Geothermal Power Plant in Korea)

  • 임효재;권정태;김금수;장기창
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.39-44
    • /
    • 2009
  • Geothermal energy is the heat contained in the earth and its internal fluids. Geothermal energy is stored as sensible or latent heat. Supplied by both internal and external sources, it represents a vast supply which is only started to be tapped for generation of electric power. In general, this is natural dry or wet medium to high enthalpy steam at temperatures above $150^{\circ}C$. For some time, binary systems employing substances with a lower boiling point than water in a secondary circuit have been used to generate vapor for driving turbines at a lower temperature level. The utilization of binary plants and the possibility of production from enhanced geothermal systems can expand its availability on a worldwide basis. The geothermal electricity installed capacity is approaching the 10,000GW threshold. Geothermal energy is not present everywhere, but its baseload capability is a very important factor for its success.

  • PDF

Adaptive Partial Shading Determinant Algorithm for Solar Array Systems

  • Wellawatta, Thusitha Randima;Choi, Sung-Jin
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1566-1574
    • /
    • 2019
  • Maximum power point tracking (MPPT) under the partial shading condition is a challenging research topic for photovoltaic systems. Shaded photo-voltaic module result in complex peak patterns on the power versus voltage curve which can misguide classical MPPT algorithms. Thus, various kinds of global MPPT algorithms have been studied. These have typically consisted of partial shading detection, global peak search and MPPT. The conventional partial shading detection algorithm aims to detect all of the occurrences of partial shading. This results in excessive execution of global peak searches and discontinuous operation of the MPPT. This in turn, reduces the achievable power for the PV module. Based on a theoretical investigation of power verse voltage curve patterns under various partial shading conditions, it is realized that not all the occurrences of partial shadings require a global peak search. Thus, an intelligent partial shading detection algorithm that provides exact identification of global peak search necessity is essential for the efficient utilization of solar energy resources. This paper presents a new partial shading determinant algorithm utilizing adaptive threshold levels. Conventional methods tend to be too sensitive to sharp shading patterns but insensitive to smooth patterns. However, the proposed algorithm always shows superb performance, regardless of the partial shading patterns.

저온 상변화 물질 특성을 이용한 태양열 물펌프 실용화 연구개발(II) ­시스템 구성 및 작동분석 (Development of a Solar Powered Water Pump by Using Low Temperature Phase Change Material ­ System Construction and Operation Analysis ­)

  • 김영복;이양근;이승규;김성태;나우정;민영봉
    • 한국축산시설환경학회지
    • /
    • 제9권2호
    • /
    • pp.69-78
    • /
    • 2003
  • 태양열을 동력원으로 하여 열에너지를 동력으로 변환, 물을 양수할 목적으로 저온 상변화물질인 펜탄을 작동물질로 하는 에너지변환장치를 제작하여 실험하였다. 장치는 각부의 크기를 그 기능과 상호작용 원리에 따라 논리에 맞게 최적 설계하였다. 장치의 제작 후 실험을 통하여 그 운전 특성을 분석하여 성능향상에 필요한 자료를 획득하고자 하였다. 작동물질인 펜탄을 가열하는 탱크 내부의 온도는 사이클 경과시간에 따라 약 $40­86^{\circ}C$ 범위에서 변동하고 있었으며, 물탱크내 온도 약 $23­24^{\circ}C$, 공기탱크 내 온도 $22­23.5^{\circ}C$ 범위에서 비교적 일정하게 유지되고 있었다. 응축기내의 온도와 냉각수출구 온도는 냉각수입구 온도수준에 따라 정의 상관관계로 변하고 있는 것을 알 수 있었으며, 또한 열 교환 능력도 냉각수 온도수준이 낮을수록 커진다는 것을 확인하였다. 물탱크 내 온도와 응축기내 온도가 상당히 차이가 나므로 물탱크와 응축기와의 연결거리를 최소화하고 연결파이프 크기를 큰 것으로 하여 내부물질이동 저항을 줄이는 것이 바람직하다는 것을 알 수 있었다. 실험 중 양수량은 1.6­2.4 liter로 나타났으며, 냉각시간의 수준에 따른 물탱크내의 흡입물높이 상승은 차이를 나타내지 않았다. 응축기로부터의 냉각수 배출파이프가 연장되지 않은 경우 냉각수 유량이 5.9 liter/min 이었으나 연장파이프가 있을 때는 2.3 liter/min으로 나타났다. 이러한 현상에서 양수하는 물의 온도가 낮고 유량이 부족한 경우에는 연장파이프를 이용하는 것이 좋고, 냉각수치 양은 풍부하지만 그 온도가 낮지 않은 경우에는 연장파이프를 이용하지 않는 것이 좋다는 사실을 알 수 있다. 실험에서의 응축기내 냉각수의 최대 열교환량은 95.75 kJ/min로 나타났다. 작동물질가열탱크와 기액 분리탱크 내의 압력은 0.13­0.14 MPa.a, 물탱크와 응축기내의 압력은 약 0.11 MPa.a정도로 나타났다.

  • PDF

학교건축의 친환경적 계획수법에 대한 사례연구 - 미국, 일본, 한국의 학교건축을 중심으로 - (A Study on Examples of Eco-Friendly School Design - Focusing on School Facilities in USA, Japan and Korea -)

  • 이지영;이경선
    • 교육시설 논문지
    • /
    • 제18권2호
    • /
    • pp.3-14
    • /
    • 2011
  • This study aims to identify differences and lessons in eco-school planning techniques and sustainable design methods by analyzing comparatively green building certification system and the cases of sustainable schools in US, Korea and Japan. As a result of the comparative analysis, green building certification system for school facilities, both domestic and international, is categorized into external environment, energy, materials and resources, and indoor environment. From the case study, it is common that roof garden and biotopes are installed for external environment, while energy saving, passive energy utilization methods for natural lighting and ventilation such as arrangement planning, courtyard, top-light, shading devices, solar panel and insulation by roof garden are most frequently used. Also, storm water uses, water saving equipment and sustainable materials are often introduced for resource savings. Concerns for indoor environment is frequently addressed by introducing natural light and ventilation in the buildings, which makes ultimately a comfortable space.

  • PDF

초고층 공동주택의 주방.욕실 배기풍속 활용을 위한 기초연구 (A Basic Study on the Utilization of Kitchen and Bathroom Exhaust Wind Velocity in High-Rise Apartment)

  • 김성용;이용호;박진철;황정하
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.226-231
    • /
    • 2011
  • This study set out to review the air current fluidity in exhaust common ducts by installing an inlet pipe at a leisure space in the PS(Pipe Shaft)room for the sake of wind power generation with kitchen and bathroom exhaust common ducts of all the equipment and air conditioning shafts in high-rise apartment. The air current functionality of kitchen and bathroom exhaust common ducts was reviewed by analyzing wind velocity changes according to changes to the area of exhaust common ducts through a simulation, changes to the wind velocity of the kitchen hood by applying an external inlet pipe, changes to the usage factor of exhaust common ducts, and changes to wind velocity by altering the form of the ventilator at the bottom of the old exhaust common duct. It was a basic study on the utilization of exhaust wind velocity in exhaust common ducts.

  • PDF

Toward residential building energy conservation through the Trombe wall and ammonia ground source heat pump retrofit options, applying eQuest model

  • Ataei, Abtin;Dehghani, Mohammad Javad
    • Advances in Energy Research
    • /
    • 제4권2호
    • /
    • pp.107-120
    • /
    • 2016
  • The aim of this research is to apply the eQuest model to investigate the energy conservation in a multifamily building located in Dayton, Ohio by using a Trombe wall and an ammonia ground source heat pump (R-717 GSHP). Integration of the Trombe wall into the building is the first retrofitting measure in this study. Trombe wall as a passive solar system, has a simple structure which may reduce the heating demand of buildings significantly. Utilization of ground source heat pump is an effective approach where conventional air source heat pump doesn't have an efficient performance, especially in cold climates. Furthermore, the type of refrigerant in the heat pumps has a substantial effect on energy efficiency. Natural refrigerant, ammonia (R-717), which has a high performance and no negative impacts on the environment, could be the best choice for using in heat pumps. After implementing the eQUEST model in the said multifamily building, the total annual energy consumption with a conventional R-717 air-source-heat-pump (ASHP) system was estimated as the baseline model. The baseline model results were compared to those of the following scenarios: using R-717 GSHP, R410a GSHP and integration of the Trombe wall into the building. The Results specified that, compared to the baseline model, applying the R-717 GSHP and Trombe wall, led to 20% and 9% of energy conservation in the building, respectively. In addition, it was noticed that by using R-410a instead of R-717 in the GSHP, the energy demand increased by 14%.

태양에너지를 이용한 식물(植物) 생산(生産) 시스템내의 양액재배(養液栽培) 환경조절(環境調節)에 관(關)한 연구(硏究) -국내(國內) 양액재배(養液栽培) 실행농가(實行農家)의 실태조사(實態調査)- (Environmental Control of Nutriculture in a Plant Production System Utilization Solar Energy -Investigation of Actual State of the Nutriculture in Korea-)

  • 김문기;남상운;손정익
    • Journal of Biosystems Engineering
    • /
    • 제16권2호
    • /
    • pp.178-187
    • /
    • 1991
  • In order to provide fundamental data for the achievement of safe environmental condition, investigation of the actual state of the nutriculture practices in Korea was carried out. The result obtained are summarized as follows. 1. Cultivation area of nutriculture was 6 ha and culture types included deep flow technique(43%), nutrient film technique(45%), gravel culture(6%), chaff charcoal culture(3%) and rockwool culture(3%). 2. Greenhouses were mostly made of pentite pipe frames and covered by polyethylene film, and culture beds were handy combination of cement blocks, concrete and styrofoam, which were not standard products. 3. Development of nutriculture system appropriate to our actual circumstances and improvement of establishments are required. 4. Since there was not farmhouse that performs the environmental measurement and environmental conditions of cultivation were very limited. sensor applied environmental control technology of nutriculture should be developed.

  • PDF

A Novel Partial Shading Detection Algorithm Utilizing Power Level Monitoring

  • Wellawatta, Thusitha;Seo, Young-Tae;Choi, Sung-Jin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.136-137
    • /
    • 2017
  • Maximum power point tracking (MPPT) under partial shading condition (PSC) is a challenging process in the PV array system. The shaded PV panel makes different peak patterns on the P-V curve and misguides the MPPT algorithm. Various kinds of global MPP (GMPP) detecting algorithms are used to overcome this issue. Generally, too frequent execution of GMPP tracking algorithm reduces the achievable power of PV panel due to time spent on the scanning process. Thus, partial shading detection algorithm is essential for efficient utilization of solar energy source. While conventional method only detects fast shading patterns, the proposed algorithm always shows superb performance regardless of the speed of partial shading patterns.

  • PDF

MICRSTRUCTURAL INVESTIGATION OF CALCINED AND SULFATED LIMESTONE FOR THE UTILIZAION IN THE AFBC ENVIRONMENT

  • Kim, Hyung-Taek;Kim, Dong-Hyung;Kim, Hong-Tae;Hyukbo Kwon
    • 한국표면공학회지
    • /
    • 제26권5호
    • /
    • pp.255-262
    • /
    • 1993
  • Major parameters determining the extent of Ca utilization were investigated for their calcination/sulfation behavior of limestone in the AFBC(Atmospheric Fluidized Bed Combustion) environments. Three different particle sizes of Fredonia limestone were investigated in the lab-scale tubular reactor. The results of the calcination codnversion of limestone imply that thesd decomposition rate of CaCO3 into CaO is dependent on the amount of heat which limestone absorbed. Hg porosimeter measurement of calcined limestone illustrated that surface area and pore volume are increased with decreasing particle size. Raw Fredonia limestone and sequentially as well as simultaneously calcined/sulfated limestones were also examined using SEM. The SEM Studied showed that the surface of the calcined limestone particles is more diffusive nature than that of the parent calcite. However, the sulfur distribution pattern of simultaneously-treated particles and that of the se-quentially-treated one shows no difference.

  • PDF