• Title/Summary/Keyword: Solar Energy Utilization

검색결과 211건 처리시간 0.021초

에너지저장장치를 이용한 제주지역 풍력발전 한계용량 증대효과 분석 (Increasing Effect Analysis of the Wind Power Limit Using Energy Storage System in Jeju-Korea)

  • 김영환;김세호
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.81-90
    • /
    • 2014
  • The Jeju-Korea power system is a small-sized network with a system demand ranging from a autumn minimum of 350MW to a summer peak of 716MW. Because Jeju island is well exposed to north-east winds with high speed, applications to connect to Jeju power system are flooded. Considering physical/environmental constraints, Jeju Self-governing Province has also target for the wind power capacity of 1,350MW by 2020. It amounts to two or three times of Jeju average-demand power and wind power limit capacity announced by Korea Power Exchange (KPX) company. Wind farm connection agreements will be signed to maximize utilization of wind resource. In spite of submarine cable HVDC connected to Korea mainland, Jeju power system is independently operated by frequency and reserve control. This study reevaluates wind power limit based on the KPX criteria from 2016 to 2020. First of all wind power generation limit are affected by off-peak demand in Jeju power system. Also the possibility capacity rate of charging wind power output is evaluated by using energy storage system (ESS). As a result, in case of using 110MWh ESS, wind power limit increases 33~55MW(30~50% of ESS), wind power constraint energy decreases from 68,539MWh to 50,301MWh and wind farm capacity factor increases from 25.9 to 26.1% in 2020.

계층분석법을 이용한 환경친화 계획요소의 중요도 분석에 관한 연구 (A Study on the Importance Analysis of Environmentally-Friendly Planning Factors Using Analytic Hierarchy Process)

  • 류지원;김정환;정응호
    • 한국환경과학회지
    • /
    • 제12권9호
    • /
    • pp.897-903
    • /
    • 2003
  • This study focuses on importance level analysis of environmentally-friendly planning factors using Analytic Hierarchy Process(AMP). This study verify different planning principle makes comparison matrix by a relative comparison value, verified consistency after yield weight to analyze more objective importance for apartment complex estate environmentally-friendly planning factor. In order to decide importance of apartment complex estate environmentally-friendly planning factors multiplying weight of verified planning principle with weight of planning factors. The results are as follows; First, importance of preservation of green tract of lands, Preparation of Biotop, Tree planting of sites, Propriety of development density high except Circulation and practical use of water. Next, valued planning factors constituent appeared to Energy efficient building plan, Rubbish recycling, thermal utilization of solar energy, Artificial tree planting of buildings etc. importantly. Finally, plan constituent that importance is underrated most appeared by Practical use of building materials and equipment, Centralization of energy and resources, Preservation of corridor etc.

태양열 난방 일체형 복합시스템의 축열조 효율개선에 관한 연구 (The Study on Efficiency Improvement of Thermal Storage Tank for Solar Combined Heating System)

  • 류남진;고광수;한유리;박윤철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.188-192
    • /
    • 2006
  • This study is conducted to improve efficiency of thermal storage tank. The thermal storage tank was designed to store heat energy that obtained from solar or the others heat sources. However, it has difficulties in storing heat with uniform temperature through the entire tank with respect to vertical direction. This kind of maldistribution of the supplied heat to the storage tank effects on the system performance. In this study is focused on utilization of the thermal stratification to improve thermal comfort for people in the house. To enhance temperature stratification of the tank, a distributor was designed and Installed in the middle of the tank. The distributor is supplies hottest water to the top side of the tank which is very close to inlet of the supply line to the heating load. The hottest water that is accumulated on top side of the tank is firstly supplied to the load with higher temperature. Reminder water takes a little time to warming up until desired supply temperature reached. This kind alternating selection of the supply temperature is improve thermal comfort with moderated system performance.

  • PDF

자연채광 유도공간에의한 전시공간내 채광에 관한 연구 (A study of Illumination on Exhibitory Space by Natural Light Through the Inducing Space)

  • 황규선;태원진
    • 한국태양에너지학회 논문집
    • /
    • 제32권1호
    • /
    • pp.48-55
    • /
    • 2012
  • In recent years, it clearly shows the tendency toward the utilization of daylight in many exhibitory buildings such as museum since the expectation of visitors for whom high illuminance levels are preferable to perceive the details of the works of art. Shading devices and special glazings are often used as the tool to control the amount of light and heat which should be avoided for the presentation of high-light sensitive art works such as paintings. Another way of controling the light is to provide the space for inducing and attenuating light in the exhibitory building. This study aims to investigate the illuminance on the exhibitory space when the space for inducing and attenuating light is applied. Interaction between the daylight and the space was simulated by Lumen Micro program with variation of the size of the exhibitory space, the length of inner wall, surface reflectivity, area of windows to obtain the illumination of the wall surface. This study shows that those variables affect the illumination on the wall surfaces. By comparing the results with suggestive illumination of KS and ICOM, available wall for display on natural lighting are suggested for the seasons and time.

투자비회수기간법을 이용한 공공청사 적용 축열식 지열히트펌프 시스템의 경제성 평가 (Economic Estimation of Heat Storage Type Geothermal source Heat Pump System Adopted in Government office Building by a Payback Period Method)

  • 고명진;오중근;김용인;김용식
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.175-182
    • /
    • 2007
  • Geothermal-energy has been getting popular as a natural energy source for green buildings these days. As a result Geothermal Source Heat Pump System (GSHPs) was being recognized effective alternative systems to conventional heating and cooling systems owing to their higher energy utilization efficiency. But GSHPs has not been popularized thereby the large amount of initial cost of the system and insufficiency of studies for economic estimation. Therefore GSHPs are being developed to make up for the weak points that are the large amount of initial cost of the system and much annual electricity consumption. In this paper, economic estimation was conducted by payback period method and it shows that the pay back period of Heat Storage Type GSHPs was calculated 6.8 years compared with the absorption Chiller-Heater system and 8.2 years compared with the Ice storage-Boiler system. Heat Storage Type GSHPs also has the lower annual source energy consumption than the conventional heating and cooling systems because of using nighttime electricity.

Multi-Objective Optimal Predictive Energy Management Control of Grid-Connected Residential Wind-PV-FC-Battery Powered Charging Station for Plug-in Electric Vehicle

  • El-naggar, Mohammed Fathy;Elgammal, Adel Abdelaziz Abdelghany
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.742-751
    • /
    • 2018
  • Electric vehicles (EV) are emerging as the future transportation vehicle reflecting their potential safe environmental advantages. Vehicle to Grid (V2G) system describes the hybrid system in which the EV can communicate with the utility grid and the energy flows with insignificant effect between the utility grid and the EV. The paper presents an optimal power control and energy management strategy for Plug-In Electric Vehicle (PEV) charging stations using Wind-PV-FC-Battery renewable energy sources. The energy management optimization is structured and solved using Multi-Objective Particle Swarm Optimization (MOPSO) to determine and distribute at each time step the charging power among all accessible vehicles. The Model-Based Predictive (MPC) control strategy is used to plan PEV charging energy to increase the utilization of the wind, the FC and solar energy, decrease power taken from the power grid, and fulfil the charging power requirement of all vehicles. Desired features for EV battery chargers such as the near unity power factor with negligible harmonics for the ac source, well-regulated charging current for the battery, maximum output power, high efficiency, and high reliability are fully confirmed by the proposed solution.

건물일체형 태양광발전시스템의 실증분석 (The Output Characteristics of 3kW BIPV System)

  • 김지훈;변문걸;이강연;김평호;조금배;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.386-389
    • /
    • 2006
  • BIPV(Building Integrated PV) system can expect dual effects that reduce expenses for establishment of PV system by adding new function as outer covering material of building expect producing the electricity. In case of PV(photovoltaic system) there are many generation differences according to the exterior environmental facts(solar cell array, design and installation condition of interactive inverter system). In this paper, we compared constitute factors of 3kW BIPV(solar cell module, inverter), operating characteristic and total system characteristic(utilization, generation efficiency, loss fact) and found out long time operating data using a watch instrumentations. By use of long time operating result, compare a totally operating characteristics, and we proposed a next building application of BIPV. BIPV system that is proposed in this paper, was established in Solar Energy research center of Chosun University, composed with system. The objective of this paper, is to provide a efficient BIPV design method through the considerations for the integration of PV system.

  • PDF

공명 튜브의 기하학적 형상에 따른 열음향 레이저의 특성 비교 연구 (The Comparative Study on the Characteristics of Thermoacoustic Laser According to Shapes of Resonance Tube)

  • 김남진;안응진;오원종;오승진;천원기
    • 에너지공학
    • /
    • 제21권2호
    • /
    • pp.133-137
    • /
    • 2012
  • 청정에너지 이용 기술 중 태양 에너지 이용 기술은 태양광 발전이나 태양열 난방 및 급탕 등 여러 분야에서 활용되고 이다. 특히, 획기적인 에너지 변환 방법인 열음향(Thermoacoustic)은 태양열 및 주변의 폐열을 이용하기 때문에 청정에너지 기술로서 주목받고 있다. 따라서 본 연구에서는 태양 에너지를 열원으로 하는 열음향 레이저의 개발을 위하여, 열음향파 발생 시스템에 전원을 공급하여 단일 튜브의 기하학적 형상에 따른 음향파의 기본 특성을 측정하였다. 본 연구는 스택의 재질 및 형상과 공명튜브의 내경(20.2 mm)을 고정하고, 스택의 위치와 길이, 공명튜브의 길이, 전원의 크기를 변화시켜 실험을 진행하였다. 실험 결과, 공명튜브의 길이가 200 mm, 스택의 길이가 25.6 mm이고, 스택의 위치가 닫힌 면으로부터 5 cm에 위치하였을 때 114.5 dB의 평균음압이 발생하였으며, 공급 전원을 35W로 변화시켰을 때 117.29 dB의 평균음압이 발생하였고, 각각 500 Hz의 주파수가 발생하였다. 또한 공명 튜브의 길이를 150 mm로 하였을 때, 115.7 dB의 평균음압과 630 Hz의 주파수가 나오는 것을 확인하였다.

계통측에서 본 풍력발전단지 도입에 따른 해결과제 및 대책연구 (Problem and Solution of Wind Farm based on Distribution Power system)

  • 윤기갑;박상만;허엽;정상봉;김홍필;이승학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.488-490
    • /
    • 2001
  • A dispered power system means a little bit of small power generation equipment located near the power-damend areas. Due to no power supply line, such a power source is very favorable for the decrease in loss of electric power supply, in comparison to the giantly focused power source, Because of small power source, this power source also corresponds promptly to the variation of power demend. On the basis of energy saving, environmental reservation, and utilization of natural or unused energy, solar power plants can be introduced into the residence section of cities and small water or wind-power plants near the urban areas. In case of Korea, some wind farm have been introduced into Cheju island, Condensed introduction of several small power sources into an used distribution line may, however, result in a big problem, it is, therefore, necessary that protective-cooporative plans between power quality and distribution line should be introduced for efficient utilization of KEPCO distribution system.

  • PDF

신재생에너지가 연계된 마이크로그리드에서 에너지 저장장치의 최적 용량 선정에 관한 연구 (A Study on Optimal Capacity of Energy Storage System in Renewable Energy Based Micorgrids)

  • 김욱원;이남형;이윤성;신제석;김진오
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.529-533
    • /
    • 2012
  • By introducing RPS(Renewable Portfolio Standard) for reduction of greenhouse gas, Renewable energy sources have becoming widespread gradually. However, Renewable energy sources, such as wind power and PV are difficult to control the output and they have intermittent characteristics of the output. These characteristics would cause some problems when it is connected in the power system. In order to solve these problems, Energy Storage Systems(ESS) are considered to use. Although there are many different storage devices, the utilization of Secondary Battery is the one of the best ways to stabilize an output fluctuation of RES because of its fast responsibility. For that reason, it would better fit a large-capacity of Secondary battery for stabilization. However, batteries cannot be installed with a large capacity blindly because of its expensive cost. So to select proper capacity of the battery is an important consideration. This paper presented a methodology for the optimal capacity and operation of ESS in microgrids.

  • PDF