• 제목/요약/키워드: Solar Energy System

검색결과 2,602건 처리시간 0.03초

PV 모듈 내 바이패스 다이오드 손상에 의한 열적 전기적 특성 변화 분석 (Analysis on thermal & electrical characteristics variation of PV module with damaged bypass diodes)

  • 신우균;정태희;고석환;주영철;장효식;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.67-75
    • /
    • 2015
  • PV module is conventionally connected in series with some solar cell to adjust the output of module. Some bypass diodes in module are installed to prevent module from hot spot and mismatch power loss. However, bypass diode in module exposed outdoor is easily damaged by surge voltage. In this paper, we study the thermal and electrical characteristics change of module with damaged bypass diode to easily find module with damaged bypass diode in photovoltaic system consisting of many modules. Firstly, the temperature change of bypass diode is measured according to forward and reverse bias current flowing through bypass diode. The maximum surface temperature of damaged bypass diode applied reverse bias is higher than that of normal bypass diode despite flowing equal current. Also, the output change of module with and without damaged bypass diode is observed. The output of module with damaged bypass diode is proportionally reduced by the total number of connected solar cells per one bypass diode. Lastly, the distribution temperature of module with damaged bypass diode is confirmed by IR camera. Temperature of all solar cells connected with damaged bypass diode rises and even hot spot of some solar cells is observed. We confirm that damaged bypass diodes in module lead to power drop of module, temperature rise of module and temperature rise of bypass diode. Those results are used to find module with a damaged bypass diode in system.

기상조건과 축열조 용량에 따른 평판형 태양열 집열기 시스템의 동적 성능 해석 (Dynamic performance analysis of flat plate solar collector system according to weather conditions and capacity of heat storage tank)

  • 박배덕;김규덕;김경훈
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.57-65
    • /
    • 2014
  • Solar energy has attracted wide attention as a promising renewable energy source. The goal of this paper is to estimate the dynamic performance of solar flat plate collector system according to the weather conditions and the capacity of heat storage tank. This study provides a detailed description of the modeling methods and materials of the system. The effects of the daily clearness index and the volume of the heat storage tank on the hourly and daily performances of the system are numerically investigated. Special attention is focused on the important system variables including the solar insolation on the collector surface, useful energy, heat loss at the collector, and collector efficiency.

자연형 태양 챔버 시스템의 성능 분석 (Performance Analysis of Passive Solar Chamber System)

  • 장향인;김병구;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.57-65
    • /
    • 2011
  • This study proposes a Passive Solar Chamber System (PSCS) as a passive method for reduction of building energy consumption. Through numerical analysis, the study quantitatively analyzes system performance and aims to provide foundational data for system design. For this purpose, the study configures different system operation modes seasonally and also computes thermal and ventilation performance of the system in accordance with design factors(solar radiation, air channel height and distance). System and ventilation efficiency increases along with increase in solar radiation and air channel distance; however, as the air channel height increases, the efficiencies showed a tendency to decrease. Upon installation of PSCS, an average of $98.23W/m^2$ of heat flux was introduced in the daytime for the month of January in comparison to walls with no PSCS installed. For the month of August, natural ventilation of $56.68m^3/h$ was shown to be supplied to the room.

태양열 시스템의 제어조건에 따른 난방 및 급탕 실증연구 (Demonstration study on Heating and Hot water According to Control Condition of Solar System)

  • 주홍진;곽희열;김정배;김종보
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.832-837
    • /
    • 2006
  • This study describes thermal performance of heating and cooling demonstration system using ETSC(Evacuated tubular solar collector) installed at Seo-gu art center of Kwangju. For demonstration study, a reading room with about $331m^2$ was heated and cooled using that system. The demonstration system was consisted of ETSCs, storage tank, hot water supply tank, subsidiary boiler, and subsidiary tank. From January to March in 2006, demonstration test were performed with 4 control mode to find the optimum control condition for solar thermal system. After experiments and analysis, this study found that solar thermal system of control mode IV was corresponded to 78% for the hot water supply and 49% for space heating.

  • PDF

태양에너지 가용잠재량 자원지도 분석 (The Analysis of a Potential Solar Energy Resource Map)

  • 정종철
    • 환경영향평가
    • /
    • 제21권4호
    • /
    • pp.573-579
    • /
    • 2012
  • Many countries have recently been expanding efforts for low-carbon global economy to solve the problem of global warming. Development and research for various types of new reusable energy is on the rise throughout the world. The most promising source of energy is the solar photovoltaic energy and the government take an initiative to establish both short-term and long-term policies to develop the solar energy potential resource map. The solar energy and industrialize area researched by GIS methods for optimum site for solar power transfer system. This study attempts to address the hot issue of the development and suitability of the solar photovoltaic energy site using GIS spatial analysis. We need to analyze and describe the solar technology, green energy policies and the energy market trend of the field.

경희대학교 태양관측시스템 (SOLAR OBSERVATIONAL SYSTEM OF KYUNGHEE UNIVERSITY)

  • 김일훈;김갑성
    • 천문학논총
    • /
    • 제13권1호
    • /
    • pp.39-54
    • /
    • 1998
  • We have developed solar observational system in the department of Astronomy & Space Sciences of KyungHee University, in order to monitor solar activities and construct solar database for space weather forecasting at maximum of 23rd solar cycle, as well as an solar education and exercise for undergraduate students. Our solar observational system consists of the full disk monitoring system and the regional observation system for H a fine structure. Full disk monitoring system is made of an energy rejection filter, 16cm refractor, video CCD camera and monitor. Monitored data are recorded to VHS video tape and analog output of video CCD can be captured as digital images by the computer with video graphic card. Another system for regional observation of the sun is made of energy rejection filter, 21cm Schmidt-Cassegrain reflector, H a filter with 1.6A pass band width and $375\times242$ CCD camera. We can observe H a fine structure in active regions of solar disk and solar limb, by using this system. We have carried out intense solar observations for a test of our system. It is found that Quality of our H a image is as good as that of solar images provided by Space Environmental Center. In this paper, we introduce the basic characteristics of the KyungHee Solar Observation System and result of our solar observations. We hope that our data should be used for space weather forecasting with domestic data of RRL(Radio Research Laboratory) and SOFT(SOlar Flare Telescope).

  • PDF

타워형 태양열발전을 위한 열유속 분포 측정기술 개발 (Development of Flux Mapping Technique for the Solar Power Tower Plant)

  • 채관교;이현진;김종규;윤환기;이상남;강용혁;서태범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.274-279
    • /
    • 2012
  • Daegu Solar Power Tower Plant of 200 kW thermal capacity was developed for the first time in Korea, 2011. Measurement of the heat flux distribution is essential to evaluate the solar energy concentrated by reflectors and to design a suitable receiver. The flux mapping technique, which uses a radiometer and a diffuse plate, is common for measurement of the heat flux distribution. Because the solar power tower plant has a wide concentration area, the flux mapping technique using a fixed diffuse plate is difficult to apply. Therefore, the flux distribution in the solar power tower plant should be measured by the flux mapping technique using a small moving bar. In this study, we measured flux distributions with the moving-bar system developed at the KIER solar furnace and evaluated its applicability for the solar power tower plant.

  • PDF

병렬식 하이브리드 흡수식 냉온수기 동특성 시뮬레이션 연구 (A Study on Dynamic Simulation of a Hybrid Parallel Absorption Chiller)

  • 신영기;서정아;우성민;김효상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.630-635
    • /
    • 2008
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism have been modeled. Flow discharge coefficients of the valves and the pumps were optimized for the double-effect mode with solar-heated water circulated. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. And the cases of the double mode with and without the solar energy were compared. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the single mode utilizing the solar energy only is not practical. It is suggested to operate the system in the double mode and the flow rate control system adaptive to variable solar energy input has to be developed.

  • PDF

태양광발전원을 고려한 전력계통의 신뢰도평가에 관한 기초연구 (A Basic Study on the Probabilistic Reliability Evaluation of Power System Considering Solar/Photovoltaic Cell Generator)

  • 박정제;오량;최재석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.19-21
    • /
    • 2008
  • Renewable energy resources such as wind, wave, solar, micro hydro, tidal and biomass etc. are becoming importance stage by stage because of considering effect of the environment. Solar energy is one of the most successful sources of renewable energy for the production of electrical energy following wind energy. And, the solar/photovoltaic cell generators can not make two-state model as conventional generators, but should be modeled as multi-state model due to solar radiation random variation. The method of obtaining reliability evaluation index of solar cell generators is different from the conventional generators. This paper presents a basic study on reliability evaluation of power system considering solar cell generators with multi-states.

  • PDF

1단 증발식 해수담수화 시스템의 계절별 성능 평가 (Evaluation of seasonal performance for single-stage desalination system with solar energy)

  • 곽희열;주홍진;주문창;김정배
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.221-226
    • /
    • 2008
  • This study was carry out evaluation of seasonal performance for the decentralized desalination system with the solar thermal system and the photovoltaic power system. First operating demonstration system was set up in Cheju in 2006. These system comprises the desalination unit with designed daily fresh water capacity of $2m^3$ and is supplied by a $120m^2$ evacuated tubular solar collector, a $6m^3$ heat storage tank, and a 5kW photovoltaic power generation supply the electricity for hydraulic pumps to move the working fluids. In a spring season day average $392W/m^2$, the daily fresh water showed to produce about 340liter. In a summer season day average $296W/m^2$, the daily fresh water showed to produce about 328liter. In a autumn season day average $349W/m^2$, the daily fresh water showed to produce about 277liter. In a winter season day average $342W/m^2$, the daily fresh water showed to produce about 271liter.

  • PDF