• 제목/요약/키워드: Solar Energy System

검색결과 2,602건 처리시간 0.027초

건물통합을 위한 태양에너지 cogeneration panel 특성 분석 연구 (The Performance Assessment Study of Solar Energy Cogeneration panel for Building Integrated System)

  • 김용환;강은철;현명택;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.35-42
    • /
    • 2006
  • Solar Thermal-Electric Integrated system can be used to generate heat and electricity simultaneously and can improve indoor all qualify. So, it can save heating and electricity cost as it operates at relatively lower temperatures. In this study, one pv module was fixed on a normal wall and a pv module was mounted on a solarwall. And a ventilation fan in the solar energy cogeneration panel was operated from 12:00 to 17:00 hours. Experimental results are recorded and anaysized. The comparison of results show that the temperature of PV on solar energy cogeneration panel was decreased by $7{\sim}9^{\circ}C$ and the electrical output was improved by $2{\sim}3W$ compared with a PV system without solarwall.

실리카겔을 이용한 흡착식 담수화 시스템 개발 (Development of Adsorption Desalination System Utilizing Silica-gel)

  • 현준호;;이윤준;천원기
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.364-369
    • /
    • 2012
  • The development of solar thermal energy used adsorption desalination technology have been examined as a viable option for supplying clean energy. In this study, the modelling of the main devices for solar thermal energy used and adsorption desalination system was introduced. Silica gel type adsorption desalination system is considered to be a promising low-temperature heat utilization system. The design is divided into three parts. First, the evaporator for the vaporization of the tap water is designed, and then the reactor for the adsorption and release of the steam is designed, followed by the condenser for the condensation of the fresh water is designed. In addition, new features based on the energy balance are also included to design absorption desalination system. In this basic research, One-bed(reactor) adsorption desalination plant that employ a low-temperature solar thermal energy was proposed and experimentally studied. The specific water yield is measured experimentally with respect to the time controlling parameters such as heat source temperatures, coolant temperatures, system switching and half-cycle operational times. Desalination is processes that permeate our daily lives, but It requires substantial energy input, powered either from electricity or from thermal input. From the environmental and sustainability perspecives, innovative thermodynamic cycles are needed to produce the above-mentioned useful effects at a lower specific energy input. This article describes the development of adsorption cycles for the production of desalting effects. We want that this adsorption system can be driven by low temperature heat sources at 60 to $80^{\circ}C$, such as renewable, solar thermal energy.

  • PDF

태양열 실증시스템의 진공관형 태양열 집열기 장기 열성능 (Long-term thermal performance of evacuated tubular solar collector for demonstration system)

  • 이호;주홍진;윤응상;김상진;곽희열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.104-110
    • /
    • 2008
  • This paper presents demonstration study results derived through field testing of a part load solar energized cooling system for the library of a cultural center building located in Gwangju, Korea. First operating demonstration system was set up in Gwangju in 2005. These system comprises the $200m^2$ evacuated tubular solar collector, a $6m^3$ heat storage tank. In a 2006, daily average of insolation showed about $506W/m^2$, the solar collector efficiency was 44%. In a 2007, daily average of insolation showed about$507W/m^2$, the solar collector efficiency was 42%. As a result, evacuated tubular solar collector kept the high efficiency for two years.

  • PDF

태양열 온실 난방에 대한 최척 집열 면적과 경제성 평가 (Optimum Collector Area and Economic Evaluation for the Greenhouse Heating)

  • 박이동;김규인
    • 태양에너지
    • /
    • 제2권1호
    • /
    • pp.49-58
    • /
    • 1982
  • Aim of this study was to obtain the heating performance and the economic evaluation on solar heating system for greenhouse which area of floor was $90m^2$. For heating performance effective solar energy for the greenhouse was compared with overall heating loads including coefficient of heat transfer and conduction. And the economic evaluation solar heating system was evaluated by comparison its initial investiment costing with oil saving cost. Initial investiment costing included collector cost, storage cost, piping cost, control system cost and miscellaneous costs which included pumps, motors etc. The contents of this study included the survey of climate conditions for solar heating, long-term collector performance and optimum collector area of solar heating system in existing greenhouse. The results are follows: 1. Average horizontal radiation during winter was $2,434Kcal/m^2$ day which was the highest value in this country, so the climate conditions of Suwon was suitable for solar heating. 2. Resulting calculation of the optimum collector area was $30m^2$ and the solar energy accounted for 30% of the overall heating load. 3. The capacity of storage tank required 60 liter per unit area ($m^2$) of solar collector.

  • PDF

태양열 실증 시스템의 냉방 및 급탕 일일 열성능 (Thermal performance of solar cooling and hot water for the demonstration system)

  • 이호;김상진;주홍진;곽희열
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.564-569
    • /
    • 2007
  • This study describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu art center of Kwangju. For demonstration study, a reading room with about 350㎡ was heated and cooled with the solar system. The system was consisted of ETSCs, storage tank, hot water supply tank, subsidiary boiler, subsidiary tank, absorption chiller, chiller storage tank, and cooling tower. The results of the experimental study indicated that the total solar energy gain as daily performance on a sunny day (August 25, 2007) with total daily radiation of $606\;W/m^2$ was 671 kWh, the collecting efficiency of 55%. In the case of supplies to heat source more than $83^{\circ}C$, cooling time operated by solar was driven 8.8 hours, cooling energy generated by solar system was 179 kWh and the solar cooling fraction was 79.2%, and hot water supplied with surplus heat source by the solar system was 201 kWh.

  • PDF

태양열 이용 흡수식 냉난방시스템의 스프레드쉬트 모델 (Solar Absorption System Analysis with Spreadsheet Models)

  • 최홍규
    • 태양에너지
    • /
    • 제12권1호
    • /
    • pp.15-24
    • /
    • 1992
  • 태양열이용 LiBr-water 흡수식 냉난방시스템의 시간단위의 simulation model을 SuperCalc spreadsheet를 사용해서 제시하였고 전체시스템의 열성능을 분석함으로써 spreadsheet simulation 방식의 가치를 입증하였다. Arizona, Tucson에 위치한 사무실형 건물의 시간단위의 냉난방 부하를 ASHRAE 방식에 의하여 계산하였으며 전체 시스템의 구성요소 및 제어 방식에 대한 알고리즘을 제시하였다. 두 종류의 흡수식 시스템의 열성능을 시스템 매개변수를 이용해서 비교하였다.

  • PDF

동아시아 지역의 태양에너지 자원 정밀조사 (A Detailed Survey of Solar Energy Resources in East Asia Areas)

  • 조덕기;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.150-153
    • /
    • 2008
  • Since the solar radiation is the main input for sizing any solar photovoltaic system, it will be necessary to understand and evaluate the solar radiation data. The works presented here are the analysis of solar radiation data for East Asia areas. The data, which consist of the global radiation on horizontal surface, were measured at 16 different stations over the South Korea and were estimated by using satellite at 12 different stations over the North Korea from 1982 to 2004. Also the data over the Japan have been collected for 30 years for the period from 1941 to 1970. The Result of the analysis shows that the annual-average daily global radiation on the horizontal surface is 3.55 kWh/$m^2$. We conclude, based on the analysis, that East Asia areas have sufficient solar energy resources for the photovoltaic power generation system.

  • PDF

Dish-Stirling 태양열 발전시스템 운전 및 성능분석 (Performance of Dish-Stirliling Solar Power System)

  • 김진수;강용혁;이상남;윤환기;유창균;김종규;조덕기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.180-183
    • /
    • 2006
  • As a final step for developing a small-scale solar thermal power generation technology, a demonstration project for a dish-stirling power system has been carried out by KIER. During the two years project period, 10kW solar-only power system was built in Jinhae city and successful solar operations were demonstrated. In this paper an example of typical clean day operation and analysis results was introduced.

  • PDF

태양광조명장치용 고정밀 태양위치 검출시스템 (Sun point detector for daylight system)

  • 김선호;김병철
    • 한국기계가공학회지
    • /
    • 제9권4호
    • /
    • pp.26-31
    • /
    • 2010
  • Finding sufficient supplies of clean energy for future is one of the society's most important challenges according to technologies. Alternative renewable energy source such as solar energy can be substituted for exceeding human energy need. The main factor affect to solar performance is a collective intensity. To enhance intensity, suitable equipment is a solar tracker. The solar tracker consists of sun point detector module, mechanical mechanism module with actuator and control system module. This paper presents sun point detector for solar tracker of daylight system. To evaluate the detecting accuracy, an experimental device is implemented. In experimental results, the accuracy of development system has under 0.11%/0.5deg.

태양광 추적장치용 1층 구조의 극좌표 운동기구 개발 및 평가 (Development and Evaluation of 1 Layer Polar Motion Control System for Solar Tracker)

  • 김선호;김병철
    • 한국기계가공학회지
    • /
    • 제9권1호
    • /
    • pp.67-73
    • /
    • 2010
  • Finding sufficient supplies of clean energy for future is one of the society's most important challenges according to technologies. Alternative renewable energy source such as sun energy can be substituted for exceeding human energy need. The main factor affect to solar performance is a collective intensity. To enhance intensity, suitable equipment is a solar tracker. This paper presents design and evaluation of 1 layer polar motion control system for solar tracker suitable for building integrated system. To evaluation of tracking accuracy and adaptability, solar tracker with 64 links is implemented. In experimental results, the accuracy of tracking has under ${\pm}0.0287^{\circ}$ and the thickness has under 140mm.