Solar $CO_2$ Reforming of Methane Using $Ni/{\gamma}-Al_2O_3/Metallic$ foam device ($Ni/{\gamma}-Al_2O_3/Metallic$ device를 이용한 고온 태양열 메탄-이산화탄소 개질반응)

  • Shin, Il-Yoong;Lee, Ju-Han;Lee, Jin-Gyu;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.275-281
    • /
    • 2011
  • Solar reforming of methane with $CO_2$ was successfully tested with a direct irradiated absorber on a parabolic dish capable of $5kW_{th}$ solar power. The new type of catalytically activated metallic foam absorber was prepared, and its activity was tested. Ni was applied as the active metal on the gamma - alumina coated Ni metal foam for the preparation of the catalytically-activated metal foam layer. Compared to conventional direct irradiation of the catalytically-activated ceramic foam absorber, this new metallic foam absorber is found to exhibit a superior reaction performance at the relatively low insolation or at low temperatures. In addition, unlike direct irradiation of the catalytically-activated ceramic foam absorber, metallic foam absorber has better thermal resistance, which prevents the emergence of cracks caused by mechanical or thermal shock. The total solar power absorbed reached up to 2.1kW and the maximum $CH_4$ conversion was almost 40%.

  • PDF

Performance Evaluation of SiC Honeycomb Modules Used for Open Volumetric Solar Receivers (개방형 체적식 흡수기를 위한 SiC 허니컴 모듈의 성능 평가)

  • Chai, Kwan-Kyo;Lee, Hyun-Jin;Kim, Jong-Kyu;Yoon, Hwan-Ki;Lee, Sang-Nam;Han, In-Sub;Seo, Doo-Won
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.120-125
    • /
    • 2012
  • Daegu Solar Power Tower Plant of a 200 kW thermal capacity uses an open air receiver. An air receiver is generally based on the volumetric receiver concept with porous ceramic absorbers. Because absorber material is important in the volumetric receiver, ceramic materials with excellent thermal conductivity, high solar absorptivity and good thermal stability have been researched. KIER also developed SiC honeycomb absorber modules and evaluated performance of the modules at the KIER solar furnace. For performance evaluation, we made an open volumetric receiver containing the modules and measured the outlet temperature and the efficiency. It is demonstrated that performance of the KIER absorber is comparable to that of a reference absorber developed by DLR.

  • PDF

Experimental Study on the Thermal Performance of a Domestic Solar Air Heater with Protruding Triangular Openings on the Absorber Plate (흡열판에 돌출형 삼각 개구부가 설치된 가정용 태양열 공기가열기의 열성능에 대한 실험적 연구)

  • Kim, Hyun Gon;Boo, Joon Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.41-51
    • /
    • 2016
  • A solar air heater was designed for supplementary domestic heating. The absorber plate had a series of protruding notches which had triangular openings on the front surface of the absorber plate to direct partial air flow to the rear surface and to enhance the convective heat transfer to the flowing air. The height of the opening as well as the opening configuration was determined by preceding numerical simulations. The experimental model had an absorber plate of 0.78-m width and 1.0-m length which was coated with black paint. The air temperature increased as much as $18^{\circ}C$ for $90-m^3/h$ flow rate when the absorber plate was inclined by $45^{\circ}$ for a clear-day solar irradiation of about $906W/m^2$. The collector efficiency ranged from 69 to 74%. Considering the simplicity of the structure and low manufacturing cost, the solar air heater might have competence as an auxiliary heating device for domestic use. On-site experimental results are presented with discussion for various solar irradiations and air flow conditions.

Solar CO2-Reforming of Methane Using a Double-Layer Absorber (더블 레이어 흡수기를 이용한 고온 태양열 메탄-이산화탄소 개질반응)

  • Kim, Dong-Yeon;Lee, Jin-Gyu;Lee, Ju-Han;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.267-273
    • /
    • 2012
  • Solar reforming of methane with CO2 was successfully tested with a direct irradiated absorber on a parabolic dish capable of 5kWth solar power. And the new type of double-layer absorber-the front layer, porous metal foam which absorbs the radiation and transfers the heat from material to gas, and the back layer, catalytically-activated metal foam-was prepared, and its activity was tested by using electric furnace. Ni was applied as the active metal on the gamma-Al2O3 coated Ni metal foam for the preparation of the catalytically-activated metal foam layer. Compared to conventional direct irradiation of the catalytically activated metal foam absorber, this new type of double layer absorber is found to exhibit a superior reaction and thermal storage performance at the fluctuating incident solar radiation. In addition, unlike direct irradiation of the foam absorber, double layer absorber has better thermal resistance, which prevents the emergence of cracks caused by mechanical or thermal shock. The total solar power absorbed reached up to 3.25kW and the maximum CH4 conversion was almost 59%.

  • PDF

Solar CO2-Reforming of Methane Using a Double-Layer Absorber (더블 레이어 흡수기를 이용한 고온 태양열 메탄-이산화탄소 개질반응)

  • Kim, Dong-Yeon;Shin, Il-Yoong;Lee, Ju-Han;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.80-86
    • /
    • 2011
  • Solar reforming of methane with CO2 was successfully tested with a direct irradiated absorber on a parabolic dish capable of 5kWth solar power. And the new type of double-layer absorber - the front layer, porous metal foam which absorbs the radiation and transfers the heat from material to gas, and the back layer, catalytically-activated metal foam - was prepared, and its activity was tested by using electric furnace. Ni was applied as the active metal on the gamma-Al2O3 coated Ni metal foam for the preparation of the catalytically-activated metal foam layer. Compared to conventional direct irradiation of the catalytically activated metal foam absorber, this new type of double layer absorber is found to exhibit a superior reaction and thermal storage performance at the fluctuating incident solar radiation. In addition, unlike direct irradiation of the foam absorber, double layer absorber has better thermal resistance, which prevents the emergence of cracks caused by mechanical or thermal shock. The total solar power absorbed reached up to 3.25kW and the maximum CH4 conversion was almost 59%.

  • PDF

Study on Performance Comparison for Solar Collectors with Single Evacuated Tube using Surface Treatment and Commercial Double Evacuated Tube (표면처리를 이용한 단일진공관과 기존 이중진공관 태양열집열기의 성능비교 연구)

  • Chun, Tae-Kyu;Yang, Young-Joon;Lee, Kyung-Hee;Ahn, Young-Chull
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.149-156
    • /
    • 2013
  • The performances of solar collectors with single and double evacuated tube were experimentally compared. The solar collector with single evacuated tube using surface treatment in this study consists of radiation fin, heat pipe, absorber plate, glass tube, cap and regulating valve, and so on. Surface treatment was conducted for heat pipe and absorber plate with black chrome plating and copper black coating. As the results, the performance of solar collector with single evacuated tube using surface treatment showed good results compared that of double evacuated tube. Absorber plate played a positive role in performance and showed increase of about 28%. Further performance depends on vacuum degree and vacuum degree has to be considered economical efficiency in solar collector.

Development of Passive Solar Water Heater 1. Selective absorbers (자연형 온수 급탕시스템 개발)

  • Lee, K.D.;Auh, P.C.M.;You, C.K.
    • Solar Energy
    • /
    • v.4 no.2
    • /
    • pp.29-36
    • /
    • 1984
  • This paper reviews the current status of R&D work on selective absorber materials. For the efficient utilization of solar energy, various types of selective absorber materials are being used for solar hot water heaters. Many selective absorbers which have been proposed and designed up to data are classified according to the absorption mechanisms. Temperature-time cycle method is often recommended for the measurement of solar absorptance. In addition, conversion efficiency of the solar collector with selective surface is compared with one with black paint surface.

  • PDF

Solar Steam Reforming of Methane utilizing Solar Simulator (Solar Simulator를 이용한 프로판의 수증기 개질 반응)

  • Do, Han-Bin;Jang, Jong-Tak;Han, Gui-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.259-261
    • /
    • 2009
  • Solar simulator를 이용한 프로판의 수증기 개질은 집광된 태양에너지를 이용하기 위한 목적으로 수행되었다. 본 연구에서는 이와 같은 태양열에너지의 화학적 축열을 실시하기 위해 Solar Simulator를 이용한 메탄의 수증기 개질을 연구하였다. 태양열 모사 램프로 1.24kW급 Xenon-arc lamp를 사용하였다. 반응기는 앞면의 Quartz window와 Absorber로 구성되어 있다. 램프의 빛은 Quartz window를 통하여 촉매층에 직접적으로 방사된다. 프로판의 수증기개질 반응은 고온에서 일어나기 때문에 열에 강한 SiC로 만들어진 Ceramic foam을 Absorber로 사용하였다. 촉매는 Absorber에 Wash-coat하여 사용하였으며, 담지된 촉매는 Ni을 활성성분으로 하는 ICI 46-6와 귀금속 촉매인 Ru/$Al_2O_3$를 사용하였다. 반응기는 SUS 재질로 제작되었으며, 반응기 외부는 Insulation을 하여 열손실을 감소시켰다. Propane과 Steam의 비율은 S/C ratio를 3으로 하여 실험하였다. 실험은 온도와 촉매에 따른 Solar Steam reforming의 반응특성을 분석하였다.

  • PDF

A New Approach to Design Method of the Solar Compound Parabolic Concentrator with Tubular Absorber (태양열집속집열기의 설계 방법에 관한 연구)

  • Kim, Seok-Jong;Lim, Sang-Hoon
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.33-38
    • /
    • 2002
  • The intermediate range of temperatures($100{\sim}300^{\circ}C$) which can be achieved with CPCs(Compound Parabolic Concentrators) without tracking device provides both economic and thermal advantages for solar collector design. The present paper summarizes critical design considerations for CPC with cylindrical absorber and its optical performance using ray tracing program. Concentration ratios vary as acceptance half angle, ratio of reflector height to aperture width and ratio of reflector area to aperture area. This effects showed that the concentration ratio was increased as acceptance angle but optimum ratio of reflector height to aperture width existed at critical value. As a result of ray tracing, solar ray losses was maximized at acceptance half angle and this problem was solved by increasing absorber tube diameter. The concentrating flux distribution on the absorber surface was uniform but peak flux existed.

A Study on Performance of Flat Water-type PVT Modules According to Absorber Type (흡열판의 종류에 따른 Unglazed PVT 모듈의 성능 실험 분석)

  • Chun, Jin-Aha;Jeong, Seon-Ok;Kim, Jin-Hee;Kim, Jun-Tae;Cho, In-Soo;Nam, Seung-Baeg
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.93-98
    • /
    • 2011
  • A photovoltaic/thermal(PVT)collector produces both thermal energy and electricity simultaneously. The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. A PVT module is a combination of PV module with a solar thermal collector which forms one device that converts solar radiation into electricity and heat. In general, there are two different types of PVT module: glazed PVT module and unglazed PVT module. On the other hand, two types of the PVT module can be distinguished according to absorber on PV module rear side: the sheet-and-tube absorber PVT module and the fully wetted absorber PVT module. The absorber collector plays an important function in PVT system. It cools down the PV module, while collecting the thermal energy produced in the form of hot water. The aim of this study is to compare the electrical and thermal performance of two different PVT collectors, one with the rectangular tube and the other with fully wetted absorber PVT collectors. For this paper, the PVT collectors with two different types of thermal absorber were made, and both the thermal and electrical performance of them were measured in outdoor, and the results were compared. The experimental results were analyzed that the thermal efficiency of the fully wetted absorber PVT collector is about 8.7% higher than the sheet-and-tube absorber PVT collector, and for the electrical efficiency, the fully wetted absorber PVT collector had about 7% higher than the rectangular tube absorber.