• 제목/요약/키워드: Soil water content model

검색결과 229건 처리시간 0.03초

Estimation of Soil Organic Carbon Stock in South Korea

  • Thi, Tuyet-May Do;Le, Xuan-Hien;Van, Linh Nguyen;Yeon, Minho;Lee, Giha
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.159-159
    • /
    • 2022
  • Soil represents a substantial component within the global carbon cycle and small changes in the SOC stock may result in large changes of atmospheric CO2 particularly over tens to hundreds of years. In this study, we aim to (i) evaluate the SOC stock in the topsoil 0 - 15 cm from soil physical and chemical characteristics and (ii) find the correlation of SOC and soil organic matter (SOM) for national-scale in South Korea. First of all, based on the characteristics of the soil to calculate the soil hydraulic properties, SOC stock is the SOC mass per unit area for a given depth. It depends on bulk density (BD-g/cm3), SOC content (%), the depth of topsoil (cm), and gravel content (%). Due to insufficient data on BD observation, we establish a correlation between BD and SOC content, sand content, clay content parameter. Next, we present linear and non-linear regression models of BD and the interrelationship between SOC and SOM using a linear regression model and determine the conversion factor for them, comparing with Van Bemmelen 1890's factor value for the country scale. The results obtained, helps managers come up with suitable solutions to conserve land resources.

  • PDF

지하수위 변동 예측 및 비포화대 함수모델을 이용한 지하수 함양율 산정 연구 (A Study on Delineation of Groundwater Recharge Rate Using Water-Table Fluctuation and Unsaturate Zone Soil Water Content Model)

  • 조진욱;박은규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제13권1호
    • /
    • pp.67-76
    • /
    • 2008
  • 본 연구에서는 지하수위 변동모델과 비포화대 함수모델을 적용한 지하수 함양율 산정 기법을 제안하였다. 기법의 적용성을 살펴보기 위하여 연구지역인 국내 4개 국가지하수 관측소를 선정하였으며 1996년부터 2005년에 이르는 국가 지하수 관측망(포항 연일, 기북, 순천 외서, 홍천 홍천) 수위자료와 포항, 순천, 홍천의 기상청 강우자료가 이용되었다. 각 관측소 주변 토양형에 따른 지하수 함양율은 홍천 관측소가 최소 0.5%에서 최대 61.4%, 포항 연일 관측소는 1.1%에서 27.4%, 포항 기북 관측소는 5.1%에서 41.4%, 및 순천 외서 관측소는 1.1%에서 8.3%의 분포를 보였다. 본 연구에서 이용된 지하수위 변동예측 모델은 지하수위 변동이 강우에 의해서만 발생하는 것으로 가정하였으며 향후 보다 정확한 지하수위 예측을 위해서 지하수 채수나 증발산의 영향을 추가 고려할 필요가 있을 것이라 판단된다. 또한 제안된 기법의 보다 넓은 범위의 적용을 위해서는 비포화 암반의 함수 모델을 도입할 필요가 있을 것이라 판단된다. 현재 본 연구를 공간적으로 확장하여 지역화 하기 위한 연구가 진행 중이다. 본 연구에서 제안하는 지하수 함양율 산정 기법은 가정을 최소화함으로써 방법론적으로 합리적이며 실제 지하수 시스템을 잘 반영하는 과학적인 모델로 기존 지하수 함양율 산정 기법을 충분히 대체할 수 있을 것이라 판단된다.

일별 기상자료를 이용한 농경지 물 수지 및 토양수분 예측모형 (AFKAE0.5) 개발 (The Development of Estimation Model (AFKAE0.5) for Water Balance and Soil Water Content Using Daily Weather Data)

  • 서명철;허승오;손연규;조현숙;전원태;김민경;김민태
    • 한국토양비료학회지
    • /
    • 제45권6호
    • /
    • pp.1203-1210
    • /
    • 2012
  • 밭 재배면적이 증가하면서 토양내 수분함량에 따른 적정관개가 작물생산성에 중요한 역할을 기 때문에 손쉽게 농가에서 포장의 토양수분함량을 파악하고 대처하는 것이 중요하다. 본 시험은 농경지에서 간단한 일 기상자료와 관개이력으로 물 수지 및 토양수분함량을 일단위로 추정하기 위하여 AFKAE0.5 토양수분추정모형을 개발하고 이를 검증을 하고자 하였다. 다양한 토양의 특성을 단순화 하기 위해 대상토양을 300mm의 균일한 토양으로 가정하였고 대상 토양지하에서 물 이동을 정의하기 위하여 토양수분장력에 따른 3개의 수분영역을 설정하여 투수량과 상승량을 산출하여 물 수지에 반영하였다. 토양 물수지에서 투입요인으로는 강우, 관개, 수분 상승량을 설정하였고 산출요인으로는 증발산, 유거, 투수량을 설정하여 모형을 개발하였다. 각 요인의 물량 산출을 위한 추정모형은 문헌 및 보고서를 이용하여 작성하였으며 모형을 검증하기 위해 공주지역 고추포장을 대상으로 작부기간 동안 AFKAE0.5 모형을 이용하여 모의하여 물 수지를 산출하였으며 모형의 검증을 위하여 실제 포장에서 층위별 센서를 이용하여 측정한 토양수분함량 변화 값을 비교하였다. 대상 포장에 대해 AFKAE0.5 모형의 모의 결과 투입부분으로 연간 강우, 관개, 수분상승량은 각각 1,043, 0, 207 mm이었으며 산출요인으로 증발산, 유거, 투수량은 각각 831, 309, 161 mm로 산출되어 투입된 물보다 산출된 물의 양이 88 mm 많았다. 또한 작부기간중 증발산량에 대해 지하에서 상승하는 수분량이 24.7%에 해당되어 건조기에 지하에서 모세관 등을 통해 상승하는 양도 상당한 것을 알 수 있었다. 작부기간 중 토양수분 측정값과 AFKAE0.5 모형의 모의 값과 토양수분함량의 변화를 일별로 비교한 결과 포화 되었을 때의 수분함량이 유사하였으며 건조에 따른 수분함량 일별 감소비율이 매우 유사하게 나타나고 있어 모형이 적합한 것으로 평가되었다. 개발된 AFKAE0.5 토양 물수지 및 수분추정 모형은 농가에서 손쉽게 자가 포장에 대한 기본적인 영농이력을 알고 있으며 포장의 수분상태를 알 수 있고 적정관개를 할 수 있는 유용한 도구로서 역할을 할 것으로 기대된다.

토양수분함량 예측 및 계획관개 모의 모형 개발에 관한 연구(I) (A Study on the Development of a Simulation Model for Predicting Soil Moisture Content and Scheduling Irrigation)

  • 김철회;고재군
    • 한국농공학회지
    • /
    • 제19권1호
    • /
    • pp.4279-4295
    • /
    • 1977
  • Two types of model were established in order to product the soil moisture content by which information on irrigation could be obtained. Model-I was to represent the soil moisture depletion and was established based on the concept of water balance in a given soil profile. Model-II was a mathematical model derived from the analysis of soil moisture variation curves which were drawn from the observed data. In establishing the Model-I, the method and procedure to estimate parameters for the determination of the variables such as evapotranspirations, effective rainfalls, and drainage amounts were discussed. Empirical equations representing soil moisture variation curves were derived from the observed data as the Model-II. The procedure for forecasting timing and amounts of irrigation under the given soil moisture content was discussed. The established models were checked by comparing the observed data with those predicted by the model. Obtained results are summarized as follows: 1. As a water balance model of a given soil profile, the soil moisture depletion D, could be represented as the equation(2). 2. Among the various empirical formulae for potential evapotranspiration (Etp), Penman's formula was best fit to the data observed with the evaporation pans and tanks in Suweon area. High degree of positive correlation between Penman's predicted data and observed data with a large evaporation pan was confirmed. and the regression enquation was Y=0.7436X+17.2918, where Y represents evaporation rate from large evaporation pan, in mm/10days, and X represents potential evapotranspiration rate estimated by use of Penman's formula. 3. Evapotranspiration, Et, could be estimated from the potential evapotranspiration, Etp, by introducing the consumptive use coefficient, Kc, which was repre sensed by the following relationship: Kc=Kco$.$Ka+Ks‥‥‥(Eq. 6) where Kco : crop coefficient Ka : coefficient depending on the soil moisture content Ks : correction coefficient a. Crop coefficient. Kco. Crop coefficients of barley, bean, and wheat for each growth stage were found to be dependent on the crop. b. Coefficient depending on the soil moisture content, Ka. The values of Ka for clay loam, sandy loam, and loamy sand revealed a similar tendency to those of Pierce type. c. Correction coefficent, Ks. Following relationships were established to estimate Ks values: Ks=Kc-Kco$.$Ka, where Ks=0 if Kc,=Kco$.$K0$\geq$1.0, otherwise Ks=1-Kco$.$Ka 4. Effective rainfall, Re, was estimated by using following relationships : Re=D, if R-D$\geq$0, otherwise, Re=R 5. The difference between rainfall, R, and the soil moisture depletion D, was taken as drainage amount, Wd. {{{{D= SUM from { {i }=1} to n (Et-Re-I+Wd)}}}} if Wd=0, otherwise, {{{{D= SUM from { {i }=tf} to n (Et-Re-I+Wd)}}}} where tf=2∼3 days. 6. The curves and their corresponding empirical equations for the variation of soil moisture depending on the soil types, soil depths are shown on Fig. 8 (a,b.c,d). The general mathematical model on soil moisture variation depending on seasons, weather, and soil types were as follow: {{{{SMC= SUM ( { C}_{i }Exp( { - lambda }_{i } { t}_{i } )+ { Re}_{i } - { Excess}_{i } )}}}} where SMC : soil moisture content C : constant depending on an initial soil moisture content $\lambda$ : constant depending on season t : time Re : effective rainfall Excess : drainage and excess soil moisture other than drainage. The values of $\lambda$ are shown on Table 1. 7. The timing and amount of irrigation could be predicted by the equation (9-a) and (9-b,c), respectively. 8. Under the given conditions, the model for scheduling irrigation was completed. Fig. 9 show computer flow charts of the model. a. To estimate a potential evapotranspiration, Penman's equation was used if a complete observed meteorological data were available, and Jensen-Haise's equation was used if a forecasted meteorological data were available, However none of the observed or forecasted data were available, the equation (15) was used. b. As an input time data, a crop carlender was used, which was made based on the time when the growth stage of the crop shows it's maximum effective leaf coverage. 9. For the purpose of validation of the models, observed data of soil moiture content under various conditions from May, 1975 to July, 1975 were compared to the data predicted by Model-I and Model-II. Model-I shows the relative error of 4.6 to 14.3 percent which is an acceptable range of error in view of engineering purpose. Model-II shows 3 to 16.7 percent of relative error which is a little larger than the one from the Model-I. 10. Comparing two models, the followings are concluded: Model-I established on the theoretical background can predict with a satisfiable reliability far practical use provided that forecasted meteorological data are available. On the other hand, Model-II was superior to Model-I in it's simplicity, but it needs long period and wide scope of observed data to predict acceptable soil moisture content. Further studies are needed on the Model-II to make it acceptable in practical use.

  • PDF

실내모형실험을 통한 TDR 함수량계의 현장 함수비 보정 (Water Content Calibration of Time-Domain Reflectometry Probe Using Laboratory Model Test)

  • 신은철;류병현;박정준
    • 한국지반신소재학회논문집
    • /
    • 제12권2호
    • /
    • pp.1-11
    • /
    • 2013
  • 지하매설구조물인 상수도관 주변 지반의 간극수 동결로 상수도관의 변형에 영향을 미칠 수 있다. 이에 최근에는 현장 계측을 통한 포장 하부구조체의 함수비를 주기적으로 측정하기 위해서 미국 Campbell사의 TDR(time domain reflectometry) CS616 함수량계와 독일의 IMKO사 제품의 TRIME FM를 이용한 수동 함수량계 TRIME P3, T3 Probe를 사용하고 있다. 일반적으로 TDR 함수량계와 TRIME 수동 함수량계는 흙의 종류, 입도, 다짐도, 온도 등에 의해 오차가 유발될 수 있기 때문에, 현장의 시료를 사용하여 TDR 함수량계의 실내보정실험을 반드시 수행해야 한다. 즉, TDR함수량계의 매뉴얼에서는 일반적인 흙의 보정방정식을 제안하고 있지만 현장 적용시에는 반드시 보정실험을 수행하도록 권고하고 있다. 본 연구에서는 상수관 등 지하매설구조물의 주변의 다양한 채움재료를 사용하여 실내 보정 실험을 수행하였으며, 이 결과로부터 TDR함수량계인 CS616, TRIME-T3, TRIME-P3의 보정모델식을 제안하였으며, 보정식에 대한 현장검증을 수행하였다.

준설토의 체적변화 및 2차원 퇴적특성에 관한 연구 (A Study on the Sediment Volume Change and Two-dimensional Deposited Characteristics of Pumping-dredged Soil)

  • 김형주;이민선;이용주;김대우
    • 한국지반공학회논문집
    • /
    • 제19권4호
    • /
    • pp.155-165
    • /
    • 2003
  • 본 연구는 고함수비의 액상준설토의 체적변화 및 퇴적특성을 파악하기 위해 일련의 실린더침강시험, 침투압밀시험과 2차원퇴적모형실험이 실시되었다. 그리고 실험결과는 실제 준설매립현장의 퇴적상태와 비교됨으로써 설계시에 필요한 침강에 의한 체적변화량을 구할 수 있도록 하였으며, 퇴적후의 세립토의 분포와 함수비 변화 등이 함에 조사되었다. 따라서 1차원 침강시는 실질토량이 증가 할 수록 퇴적고는 선형적으로 증가하며, 자중압밀개시시 및 완료시의 계면고도 또한 실질토량에 비례하여 증가되고 있다. 한편 2차원 퇴적모형실험에 의해 함수비의 분포와 세립토의 퇴적상태를 제시하였으며, 퇴적층의 함수비는 #200체의 통과량에 따라 다르며 최소 30%에서 최대 180%까지 폭넓게 분포되고 있다.

토양 열전도도와 수분함량이 수평형 지중열교환기 설계 길이에 미치는 영향 (Effect of Soil Thermal Conductivity and Moisture Content on Design Length of Horizontal Ground Heat Exchanger)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권1호
    • /
    • pp.21-31
    • /
    • 2012
  • This paper reviewed and evaluated some of the commonly used prediction models for thermal conductivity of soils with the experimental data. Semi-theoretical models for two-component materials were found inappropriate to estimate the thermal conductivity of dry state soils. It came out that the model developed by Cote and Konrad gave the best overall prediction results for unsaturated soils available in the literature. However, it still needs to be improved to cover a wider range of soil types and degrees of saturation. In the present study, parametric analysis is also conducted to investigate the effect of soil type and moisture content on the horizontal ground heat exchanger design. The analysis shows that horizontal ground heat exchanger pipe length is reduced with the increase of soil thermal conductivity and water content. The calculation results also show that horizontal ground heat exchanger size can be reduced to a certain extent by using backfilling material with a higher thermal conductivity of solid particles.

토양수분 수지계산에 의한 옥수수 포장에서의 토양수분 이동 예측 (Predicting Water Movement in the Soil Profile of Corn Fields with a Computer-Based STELLA Program to Simulate Soil Water Balance)

  • 김원일;정구복;이종식;김진호;신중두;김건엽
    • 한국토양비료학회지
    • /
    • 제38권4호
    • /
    • pp.222-229
    • /
    • 2005
  • 단순1차원 STELLA 모델이 토양수분 수지계산에 의해 일리노이 옥수수 포장의 질소용탈을 예측하기 위하여 개발되었다. 이는 옥수수포장이라는 한정된 생태계 안에서의 물의 연간 유입량과 유출량을 산정하는데 물의 유입에는 강우량과 유출에는 유거, 증발산 및 배수량이 계산되었다. 모델에는 일일강우량과 증산량 등 2개의 기상자료가 이용되었고, 토양의 다양한 전환상수들이 토양의 물리화학성을 고려하여 일차식으로 계산되어 이용되었다. 모델의 결과는 토층에 따른 토양수분의 일일 변화량과 손실량이 산출된다. 모델에 의한 물 수지는 강우가 많았던 1993년은 늘어난 반면 강우가 적었던 1992년과 1994년에는 줄어들었다. 또한 유기물과 점토가 많은 토양에서 수분의 유출량이 적었다. 모델에 의한 토양 수분함량은 표준편차를 고려한 측정치와 토양통에 따라 22-78%, 토층에 따라 30-70%의 일치를 보였고, 이러한 불일치는 토양수분과 질소화합물의 확산 등 수평적 이동, 다른 형태의 질소 손실, 뿌리의 분포, 영농 형태 및 토양의 여러 특성들이 고려되지 않은 1차원 모델이기 때문이라 사료된다.

불포화토에서 흙의 구조가 흙-함수특성에 미치는 영향 (Effect of Soil Structure on Soil-Water Characteristic in Unsaturated Soil)

  • 황웅기;강기민;김태형;송영석
    • 한국지반공학회논문집
    • /
    • 제28권2호
    • /
    • pp.33-42
    • /
    • 2012
  • 본 연구에서는 토립자의 입경과 입도분포가 불포화토의 흙-수분특성에 미치는 영향을 검토하고자 하였다. 이를 위해 축이동기법이 적용된 시험장치를 이용하여 현장에서 채취한 새만금실트에 대해 함수특성시험을 실시하였다. 비교를 위해 주문진 표준사에 대해서도 시험을 실시하였다. 시험으로부터 측정된 모관흡수력과 체적함수비를 토대로 van Genuchten 모델에 대한 흙-함수특성곡선을 추정하였다. 추정된 함수특성곡선의 비교분석결과 포화체적함수비, 잔류체적함수비 그리고 공기함입치 모두 모래보다 실트에서 더 높게 나타났으며, van Genuchten 모델의 계수 ${\alpha}$, $n$, $m$ 모두 실트보다 모래에서 더 크게 나타났다. 이는 불포화토의 흙-함수특성곡선은 흙의 구조적 특성(간극크기, 형태, 분포)과 밀접한 관계를 가지며 상대적으로 입경이 크고 입도분포가 불량한(다시 말해, 간극크기가 크고 간극분포가 균등한) 조립토일수록 포화체적함수비, 잔류체적함수비, 그리고 공기함입치가 작고, 모관흡수력 변화에 따른 체적함수비의 변화율이 크며, 따라서 전이 영역의 범위가 좁게 나타나는 경향이 있다는 것을 보여준다.

저관리·경량형 옥상녹화를 위한 세덤류의 내서성 평가 (Hot Tolerance Assessment of Sedum spp. for Extensive Green Roof System)

  • 조홍하;손희준;강태호
    • 한국조경학회지
    • /
    • 제40권6호
    • /
    • pp.180-189
    • /
    • 2012
  • 이 연구는 저관리 경량형 옥상녹화시스템을 위한 내서성 식물 선발을 목적으로 6종 세덤식물을 대상으로 처리 시간과 온도에 따라 전해질 용출, 엽록소 함량 변화 및 재생 실험을 실시하였으며, 토양수분과 고온스트레스와의 관계를 연구하였다. Logistic비선형 회귀분석을 이용하여 6시간의 고온 처리 후 5%의 토양 함수량의 치사 온도는 $45.1{\sim}48.0^{\circ}C$, 토양 함수량 10%, 15%의 경우 각각 $47.5{\sim}49.3^{\circ}C$, $48.6{\sim}52.8^{\circ}C$의 범위로 측정되었다. 고온스트레스는 처리 시 토양 수분이 높을수록 세덤류의 내서성이 높아졌다. 엽록소 함량은 처리 온도가 높을수록 함량이 낮아졌고, 토양 수분 함량이 낮을수록 분해 속도가 높아졌다. 토양 함수량 5% 시 고온에 대한 저항성은 S. reflexum>S. takevimense>S. middendorffianum>S. album>S. sieboldii>S. spurium의 순으로 나타났으며, 토양 함수량이 15%의 경우는S. album>S. reflexum>S. spurium>S. takevimense>S. middendorffianum>S. sieboldii의 순으로 나타났다. 토양의 수분 함량이 높을수록 S. album, S. reflexum, S. spurium의 내서성이 높아졌다. 이러한 결과는 재생 검사의 결과와 전해질 용출 평가에 일관성이 있는 것으로 증명되었다.