Application of Geophysical Methods for Developing Saline Groundwater from an Coastal Aquifer (해안지역 염지하수 개발을 위한 물리탐사 적용 사례)

  • Lim, Sung Keun;Song, Sung-Ho;Kim, Soo Hong
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.4
    • /
    • pp.255-261
    • /
    • 2018
  • The purpose of this study was to obtain a large amount of saline groundwater around coastal aquaculture farms. Thus, we have proposed a method for evaluating the potential amount of saline groundwater resources through the combined analysis of geophysical methods. Refraction seismic survey and electrical resistivity survey were conducted in the vicinity of fish farm at Hadong, Gyeongnam Province. As the result, the velocity of layer in the range of 900 ~ 2,400 m/s was found to be saltwater aquifer with high water content. Geological drilling investigation and analysis of soil samples also showed that the soil at study area was the same as the texture of sandy loam layer in agricultural radial collector wells installed by KRC (Korea Rural Community Corporation). Futhermore, the study area turned out to be quite possible to develop saline groundwater from the coastal shallow aquifer. Therefore, parallel analysis of refraction seismic surveys and electrical resistivity surveys at coastal area are expected to be very useful for the detection of the aquifer composed of sand and gravel layers with high porosity in sandy sedimentary layers along the coastal area.

A Study on the Safety Characterization Grounding Design of the Inner Photovoltaic System (태양광 발전단지 내부 그리드의 안전 특성화 접지 설계에 관한 연구)

  • Kim, Hong-Yong;Yoon, Suk-Ho
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.130-140
    • /
    • 2018
  • Purpose: In this paper, we propose a design technique for the safety characterization grounding in the construction of the photovoltaic power generation complex which can be useful and useful as an alternative power energy source in our society. In other words, we will introduce the application of safety grounding for each application, which can improve and optimize the reliability of the internal grid from the cell module to the electric room in the photovoltaic power generation complex. Method: We analyze the earth resistivity of the soil in the solar power plant and use the computer program (CDEGS) to analyze the contact voltage and stratospheric voltage causing the electric shock, and propose the calculation and calculation method of the safety ground. In addition, we will discuss the importance of semi-permanent ground electrode selection in consideration of soil environment. Results: We could obtain the maximum and minimum value of ground resistivity for each of the three areas of the data measured by the Wenner 4 - electrode method. The measured data was substituted into the basic equation and calculated with a MATLAB computer program. That is, it can be determined that the thickness of the minimum resistance value is the most favorable soil environment for installing the ground electrode. Conclusion: Through this study, we propose a grounding system design method that can suppress the potential rise on the ground surface in the inner grid of solar power plant according to each case. However, the development of smart devices capable of accumulating big data and a monitoring system capable of real-time monitoring of seismic changes in earth resistances and grounding systems should be further studied.

Induced Polarization Surveys of Contaminants and Introduction to Case Studies (오염원에 대한 유도분극탐사 반응 및 사례 소개)

  • Kim, Bitnarae;Caesary, Desy;Yu, Huieun;Cho, AHyun;Song, Seo Young;Cho, Sung Oh;Joung, Inseok;Nam, Myung Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.2_spc
    • /
    • pp.86-100
    • /
    • 2020
  • Analyzing and monitoring environmental contaminants based on geophysical exploration techniques have become important and it is now widely applied to delineate spatial distribution geophysical characteristics in wide area. Among the techniques, induced polarization (IP) method, which measures polarization effects on electrical potential distribution, has drawn much attention as an effective tool for environmental monitoring since IP is sensitive to changes in biochemical reactions. However, various reactions stemming from the presence of multiple contaminants have greatly enhanced heterogeneity of polluted sites to result in highly variable electrical characteristics of the site. Those contaminants influence chemical and physical state of soil and groundwater to alter electrical double layer, which in turn influences polarization of the media. Since biochemical reactions between microbes and contaminants result in various IP effects, IP laboratory experiments were conducted to investigate IP responses of the contaminated soil samples under various conditions. Field IP surveys can delineate the spatial distribution of contamination, while providing additional information about electrical properties of a target medium, together with DC resistivity. Reviewing IP effects of contaminants as well as IP surveys can serve as a good starting point for the application of IP survey in site assessment for environmental remediation.

Characteristics of Sea Water Intrusion Using Geostatistical Analysis of Geophysical Surveys at the Southeastern Coastal Area of Busan, Korea (지구물리 탐사자료의 지구통계학적 분석에 의한 부산 동남해안 지역의 해수침투 특성)

  • 심병완;정상용;김희준;성익환;김병우
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.3
    • /
    • pp.3-17
    • /
    • 2002
  • Data analysis of groundwater monitoring wells and geostatistical methods are used to identify the local characteristics of sea water intrusion and the range of sea water intrusion at the southeastern coastal area of Busan, Korea. Rainfall and groundwater level of two monitoring wells show a linear correlation because of the direct groundwater recharge by the precipitation. However, rainfall and electric conductivity have the inverse relationship because of the increase of groundwater. Electric conductivity rapidly increased at 24m depth and exceeded 20,000$\mu\textrm{s}$/cm near 26m depth in the monitoring wells. The variations of groundwater level and electric conductivity show that the interface between sea water and fresh water tends to move upward when groundwater level goes down. In the cross correlation analysis, groundwater level versus rainfall represents the largest cross correlation coefficient in 0 time lag but the cross correlation coefficient of electric conductivity versus rainfall is the largest when the time lag is 9 days. This suggests that the fluctuations of groundwater level respond to rainfall in a short time, but the interface between sea water and fresh water respond very slow to rainfall. Horizontal extents of sea water intrusion are estimated to 14 m from the east of Line 1, and 25 m from the southeast end of Line 2 in the inversion of dipole-dipole profiling data of two survey lines. The data of VES by the Schulumberger array in May and July show lognormal distributions. In the kriged apparent resistivity and earth resistivity distributions, the resistivities of July are increased comparing to those of May. This reflects that the concentration of sea water in aquifer is reduced due to the increased groundwater recharge from the rainfall in June and July. In analyzing the vertical and horizontal apparent resistivities and earth resistivity distributions, the geostatistical methods are very useful to identify the variations of earth resistivity distributions at the coastal area.

Time-Lapse Electrical Resistivity Structures for the Active Layer of Permafrost Terrain at the King Sejong Station: Correlation Interpretation with Vegetation and Meteorological Data (세종과학기지 주변 영구동토의 활동층에 대한 시간경과 전기비저항자료의 해석: 기상 및 식생 자료와의 연계해석)

  • Kim, Kwansoo;Lee, Joohan;Lee, Eungsang;Ju, Hyeontae;Hyun, Chang-Uk;Park, Sang-Jong;Kim, Ok-Sun;Lee, Sun-Joong;Kim, Ji-Soo
    • Economic and Environmental Geology
    • /
    • v.53 no.4
    • /
    • pp.413-423
    • /
    • 2020
  • Over the wide area, King Sejong Station and the nearby land are uncovered with snow and ice conditions. Therefore, the active layer on the permafrost has been formed to be much thicker than the other Antarctica region. Electrical resistivity survey of Wenner and dipole-dipole arrays was undertaken at a series of time in the freezing season at the King Sejong Station to delineate subsurface structure and to monitor active layer in permafrost terrain. Time-lapse resistivity structures are well in terms of the vegetation distribution, ground surface temperature, and snow depth. Horizontal high resistivity belt(>1826 Ωm) at very shallow depth is thickening with the lapse of time, probably caused by the freezing of the water in the pore spaces with decrease of ground temperature. Subsurface structures for the area of low snow-cover and vegetated zone area are comprised of 0~0.5 m deep high-resistive gravel-rich soil, 0.5~3 m deep low-resistive active layer, and the underlying permafrost. In contrast, the unvegetated area and high snow-buildup is characterized with high resistivities larger than approximately 2000 Ωm due to freezing of the soil throughout the year. Data interpretation and correlation schemes explored in this paper can be applied to confirm the active layer, which is expected to get thinner in additional survey during the thawing season.

Annual Variation of Resistivity Structure in and around the Nanjido Waste Landfill (난지도 폐기물 매립장과 그 주변 지역에서의 연간 비저항구조 변화)

  • Lee, Kiehwa;Yoon, Jong-Ryeol
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • Schlumberger soundings and dipole-dipole electrical surveys were carried out in and around the Nanjido waste landfill in August and December, 1995. Survey points were set to be identical as those in August, 1994 and February, 1995 as possible. To elucidate the annual variation of resistivity structure in and around the landfill, 50 electrical soundings and 2 lines of dipole-dipole surveys were conducted. Interpretations of these data show that mean resistivity values become lower and thicknesses of contaminated layers by leachate thicker than those of the previous year in and around the landfill. Especially, mean thicknesses of saturated layers with leachate increased by about 3∼6 m and resistivities of bedrock decreased. Considering actual hydraulic conductivity, such increments of mean thicknesses are somewhat large. But resistivity variations in and around the Nanjido landfill clearly indicates contamination of layers by leachate is in progress even though some errors in measurements and interpretations are considered. On the other hand, sounding data in the back area of the landfill are almost identical to those of the previous year. From these results, it appears that contamination of weathered zone and bed rock is in progress mainly inside and in the front area of the landfill.

  • PDF

Geophysical surveys for delineation of leachate flows from AMD and buried rock wastes in Kwangyang abandoned mine (광양 폐광산의 산성광산배수의 유동경로 및 폐광석 탐지를 위한 지구물리탐사)

  • 김지수;한수형;윤왕중;김대화;이경주;최상훈;이평구
    • Economic and Environmental Geology
    • /
    • v.36 no.2
    • /
    • pp.123-131
    • /
    • 2003
  • Geophysical surveys(electrical resistivity, self-potential, seismic refraction, GPR) were conducted to investigate the physical properties of the subsurface, and to delineate the flow channel of leachate from a AMD(acid mine drainage), buried rock wastes and tailings, and drainage pipes at an abandoned mine(Kwangyang mine). Especially in rainy season the sites appear to be abundant in AMD leachate, characterized by electrical conductivities of 0.98-1.10 ms/S. Electrical resistivity sections indicate that the leachate flows running in two directions at southern part rise up through the narrow fracture zones at the central part and contaminates the surrounding soil and stream. Such schematic features at the anomalous zone are well correlated with negative peaks in self-potential data, the limited penetration depth in GPR data and low velocity zone in seismic refraction data. Shallow high-resistivity zone is associated with the buried rock wastes which cause the diffractions in GPR image. In addition, the events at depth of approximately 1-1.25 m in GPR sections must be the metal pipes through which AMD is drained off to the inner bay.

Comparison Analysis of Soil Structure Methods for Deciding the Position of a Deeply Driven Ground Rod (심매설 접지봉의 위치결정을 위한 대지구조 분석 방법들의 비교분석)

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.37-45
    • /
    • 2007
  • Recently, there has been an increase of the use of ground system for lightning protection called deeply driven grounding electrode. In the case of deeply driven grounding electrode, the rod electrode is equipped perpendicularly and deeply, therefore, it has a benefit to have less restriction of place compared to mesh grid electrode. However, ground impedance is largely changed by the local earth resistivity, so it requires a detailed analysis of the ground structure when planning. The measurement of earth resistivity by existing Wenner's method has been widely used, however, this method can not find out a change in the local ground resistance and it shows the result outwardly to be difficult to estimate exact depth. Therefore, this study analyzed the ground structure as 2-D image using 96 channels measurement facility and tried to analyze change in the local ground resistance and depth of the ground in order to design a deeply driven electrode effectively for lightning protection. It used Wenner alpha method dipole-dipole method and Schlumberger method for 2-D image analysis of the ground resistivity ma based on, it the result was compared with the ground structure analyzed with the result using the CDEGS and Wenner 1-D method.

Application of Geophysical Techniques for Observing the Void Ratio Changes of Dredged Soils (준설토의 간극비 변화 관찰을 위한 물리탐사기법의 적용)

  • Hong, Young-Ho;Lee, Jong-Sub;Lee, Changho
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.9
    • /
    • pp.19-28
    • /
    • 2014
  • It is necessary to understand the behavior of the soils for the dredging constructions. The objective of this study is to estimate void ratio and density changes of the dredged soils by using the geophysical testing methods. A series of laboratory tests is performed to obtain geotechnical index properties of the specimen, retrieved from the west coastal of Korea. The sedimentation and self-weight consolidation tests are carried out with observing changes of the interfacial height and the elastic wave velocities. The same amounts of the soils are poured into the testing column at intervals of 12 hours until the interheight reaches to a certain level. After the completion of the sedimentatation and self-weight consolidation tests, downward permeability test is performed to assess a tidal influence in the nearshore. The mini resistance cone is penetrated into the specimen to measure the electrical resistivity with depth. All tests are completely finished, the weight of specimens are measured to calculate the void ratio with the depth. Experimental results show that the aspects of the self-weight consolidation are invisible during dredging process because of rapid sedimentation characteristics of ML. However, the elastic wave velocities increase with increasing in the effective stresses. During permeability test, measured permeability and the elastic wave velocities maintain almost identical values. Void ratio based on the elastic wave velocities changes linearly with time during the step dumpings. Void ratio estimated by the electrical resistivity represents the repeatedly layered depositions according to the step-by-step dumpings. Void ratio determined by soil sampling is similar to those of elastic waves and electrical resistivity profiles. This experimental study demonstrates that the geophysical testing methods may be an effective method for evaluating the behavior of dredged soils.

GEOPHYSICAL CHARACTERIZATION OF MARINE CLAYS - FROM GEOTECHNICAL PARAMETER ESTIMATION TO PROCESS MONITORING -

  • Choi, Gye-Chun;Chang, Il-Han;Oh, Tae-Min;Kim, Hak-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09c
    • /
    • pp.37-46
    • /
    • 2010
  • Marine clays are soft soil deposits having complicated mineralogy and formation characteristics. Thus, characterization of its geotechnical behavior has been a main issue for geotechnical engineers. Nowadays, the importance and applications of geophysical exploration on marine clays are increasing significantly according to the accuracy, efficiency, and reliability of geophysical survey technology. For marine clays, seismic survey is effective for density and elasticity characterization, while electro-magnetic wave provides the information about the fluid conductivity phenomena inside soil. For practical applications, elastic wave technology can evaluate the consolidation state of natural marine clay layers and estimate important geotechnical engineering parameters of artificially reclaimed marine deposits. Electrical resistivity can provide geophysical characteristics such as particle cementation, pore geometry shape, and pore material phase condition. Furthermore, nondestructive geophysical monitoring is applicable for risk management and efficiency enhancement during natural methane gas extraction from gas hydrate-bearing sediments.