• 제목/요약/키워드: Soil resistivity

검색결과 261건 처리시간 0.028초

실시간 지중 전력케이블 용량 평가를 위한 토양 열 특성 및 온도 측정 시스템 개발 (Development of the Soil Thermal Property and Temperature Measurement System for the Real-time Ampacity Estimation of Underground Power Cables)

  • 정성환;김대경;최상봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.22-24
    • /
    • 2002
  • This paper introduces the real-time soil thermal property analyzer and temperature measuring system which is combined with radio telecommunication technique. To measure the thermal parameters in real-time, the radio telecommunication technique are used the personal communication service (PCS) which is in the world-wide serviced commercially firstly by CDMA. The thermal property analyzer has an ability of measuring thermal resistivity, thermal diffusivity and thermal stability. To estimate the soil thermal properties, the curve fitting algorithm by means of the least square method are used. TCP/IP protocol and MTM are used to install the real-time soil thermal property and temperature measurement system at multiple locations along routes of the underground power cables and to reduce the cost of telecommunication.

  • PDF

플라즈마 블라스팅, 공압파쇄, 진공추출이 활용된 지중 토양정화공법의 정화제 주입에 따른 투수성 개선 연구 (A Study on the Effect of Improving Permeability by Injecting a Soil Remediation Agent in the In-situ Remediation Method Using Plasma Blasting, Pneumatic Fracturing, and Vacuum Suction Method)

  • 이근춘;송재용;강차원;장현식;장보안;박유철
    • 지질공학
    • /
    • 제33권3호
    • /
    • pp.371-388
    • /
    • 2023
  • 지층구성이 복잡하고 저투수성의 토양이 분포하는 경우 정화효율은 급격히 저하되고 실질적인 정화가 이루어지지 않거나 정화기간이 증가하는 등의 문제가 발생한다. 효율적인 정화를 위해서는 투수성이 개선되어 오염된 구간으로 정화제 주입하여 오염물질과 충분한 접촉이 이루어져야 한다. 본 연구는 균열형성과 효과적인 정화제 유도를 위해 플라즈마 블라스팅, 공압파쇄, 진공추출을 복합적으로 활용하는 PPV 공법의 유체 전달특성을 분석하고 기존공법과의 비교를 통해 개선효과를 평가하였다. 연구는 TPH(Total petroleum hydrocarbons)로 오염된 실제 오염부지에 대한 정화제 전달효과를 확인하기 위한 실증시험을 수행하였으며 정화제의 전달특성과 영향범위 등을 산정하기 위해 주입량과 주입시간을 모니터링하고, 정성적인 지중환경 변화요인을 확인하고자 전기비저항탐사를 수행하였다. 또한, 투수시험을 수행하여 각 공법에 대한 투수성 변화를 평가하였다. 정화제의 주입량 모니터링 결과, 주입량은 대조군 대비 실험군의 주입량이 약 4.74~7.48배 증가하였고, 단위 시간 당 주입 유량(L/min)은 약 5.00~7.54배 실험군의 전달률이 빠른 것으로 분석되었다. 전기비저항탐사 결과, 실험군의 비저항변화비는 대조군과는 달리 지표까지 영향을 주어 비저항값이 전체적으로 감소하는 경향을 보인다. 따라서 실험군은 지표 상부에 분포하는 토사층까지 과산화수소 등의 유체 확산이 이루어져 저비저항 변화비가 감소하는 것을 볼 수 있으며 주입정과 추출정 사이의 수평적 변화비는 약 1.12~2.38배 비저항값이 감소되었다. 투수성의 경우, 대조군과 실험군 모두 유사한 초기 투수성을 보였으나 과산화수소의 정화기작 영향으로 투수성이 감소하는 특성을 나타내는 것으로 확인되었다. 수리전도도의 변화를 정량적으로 평가하면, 대조군은 시험 종료 후 초기 수리전도도 대비 21.1%의 수리전도도를 나타내어 투수성이 급격히 저하되는 양상을 보였으나 실험군은 실험종료 후 초기치 대비 81.3%로 초기 수리전도도와 근접한 값을 나타내는 것으로 파악되었다. 현장조사로 확인된 수리전도도와 정화재 주입실험을 통한 정화제 주입용량(m3/hr), 토양특성분석(함수비, 밀도)을 통한 공극률(%)의 분석을 통해 영향반경(ROI)을 산정산 결과, PPV 공법의 영향반경(ROI)은 대조군에 비해 평균 220% 개선되는 것으로 확인되었다. 이와 같은 성과는 PPV 공법 적용으로 인하여 기존공법 대비 보다 넓은 범위에 걸쳐 효율적인 정화제 전달이 가능하고 정화기작에서 나타나는 투수성 저해요인을 상당부분 극복할 수 있으며, 약 2배 이상의 영향반경 증대를 통해 정화효율을 높일 수 있음을 지시하는 중요한 지표로 볼 수 있다.

Analysis of Soil Ionization Behaviors under Impulse Currents

  • Lee, Bok-Hee;Park, Geon-Hun;Kim, Hoe-Gu;Lee, Kyu-Sun
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.98-105
    • /
    • 2009
  • This paper presents the characteristics of soil ionization for different water contents, and the parameters associated with the dynamic properties of a simple model grounding system subject to lightning impulse currents. The laboratory experiments for this study were carried out based on factors affecting the soil resistivities. The soil resistivities are adjusted with water contents in the range from 2 to 8% by weight. A test cell with a spherical electrode buried in the middle of the hemispherical container was used. As a result, the electric field intensity $E_c$ initiating ionization is decreased with the reduction of soil resistivities. Also, as the water content increased, the pre-ionization resistance $R_1$ and the post-ionization resistance $R_2$ became lower with increasing current amplitude. The time-lag to ionization $t_1$ and the time-lag to the second current peak $t_2$ at high applied voltages were significantly shorter than those of low applied voltages. It was found that the soil ionization behaviors are highly dependent on the water content and the applied voltage amplitude.

A Galvanic Sensor for Monitoring the External and Internal Corrosion Damage of Buried Pipelines

  • Choi, Yoon-Seok;Kim, Jung-Gu;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • 제4권5호
    • /
    • pp.178-190
    • /
    • 2005
  • In order to develop a new corrosion sensor for detecting and monitoring the external and internal corrosion damage of buried pipeline, the electrochemical property of sensors and the correlation of its output to corrosion rate of steel pipe, were evaluated by electrochemical methods in two soils of varying resistivity (5,000 ohm-cm, 10,000 ohm-cm) and synthetic tap water environments. In this paper, two types of galvanic probes were manufactured: copper-pipeline steel (Cu-CS) and stainless steel-pipeline steel (SS-CS). The corrosion behavior in synthetic groundwater and synthetic tap water for the different electrodes was investigated by potentiodynamic test. The comparison of the sensor output and corrosion rates revealed that a linear relationship was found between the probe current and the corrosion rates. In the soil resistivity of $5,000{\Omega}-cm$ and tap water environments, only the Cu-CS probe had a good linear quantitative relationship between the sensor output current and the corrosion rate of pipeline steel. In the case of $10,000{\Omega}-cm$, although the SS-CS probe showed a better linear correlation than that of Cu-CS probe, the Cu-CS probe is more suitable than SS-CS probe due to the high current output.

Critical Length Estimation of Counterpoise Subjected to Lightning Stroke Currents

  • Lee, Bok-Hee;Yoo, Yang-Woo;Kim, Jong-Ho
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.106-113
    • /
    • 2011
  • The conventional grounding impedance of a counterpoise is calculated as a function of the length of the counterpoise by use of the distributed parameter circuit model with an application of the EMTP(Electromagnetic Transient Program). The adequacy of the distributed parameter circuit model is examined and verified by comparison of the simulated and the measured results. The conventional grounding impedance of the counterpoise is analyzed for the first short stroke and subsequent short stroke currents. As a result, the simulated results show that the minimum conventional grounding impedance gives at a specified length of the counterpoise. The shorter the time taken to reach the peak of injected currents, the shorter the length of the counterpoise having the minimum conventional grounding impedance. We also present the critical lengths of the counterpoise for short stroke currents as a function of soil resistivity. Based on these results, it is necessary to compute the length of the counterpoise in a specified soil resistivity which satisfies both the low conventional grounding impedance requirement whilst also providing a suitable ground resistance in order to obtain an economical design and installation of the counterpoise.

대규모 산지지반 활동연약대 규명을 위한 지구물리탐사기법의 활용 연구 (Application of Geophysical Exploration Technique to the Identification of Active Weak Zones in Large Scale Mountainous Region)

  • 신형옥;김만일;윤왕중
    • 지구물리와물리탐사
    • /
    • 제21권3호
    • /
    • pp.162-170
    • /
    • 2018
  • 본 연구는 전라북도 완주군 ${\bigcirc}{\bigcirc}$지역에서 발생한 대규모 땅밀림 산사태 지역에서 지구물리탐사(전기비저항 탐사, 굴절법 탄성파탐사) 기법을 활용하여 대규모 산지지반 변화를 파악하고 활동연약대를 추정하고자 수행 하였다. 또한 변성암 지역에서 발생한 땅밀림 산사태 특성을 파악하고, 대략적인 규모를 파악하였다. 표준관입시험으로 얻어진 N치와 전기비저항 탐사의 저비저항 이상대, 지표지질조사로 얻어진 인장균열 위치를 비교 분석한 결과, 지표하부 10 ~ 15 m 사이에 형성되어 있는 토사층에 존재하는 불연속면을 추정하였다. 이를 토대로 토사층의 불연속면과 연구결과로 얻어진 기반암의 추정선 사이의 활동연약대 분포를 확인하였다.

익산미륵사지 지반특성에 대한 지구물리학적 연구 (A Geophysical Study on Site Characteristics of the Western Pagoda of the Mireuksa Site, Iksan, Korea)

  • 류제라;서만철
    • 지구물리
    • /
    • 제4권1호
    • /
    • pp.1-10
    • /
    • 2001
  • 많은 유형문화재들이 과학적인 보존, 보수 없이 손상되어지고 있다. 이에 국내 유형문화재의 보수?보존 방안 대책과 복원에 대한 설계 자료로의 이용을 목적으로 익산미륵사지 서탑을 대상으로 지구물리학적 탐사를 적용하였다. 전기비저항, 탄성파, GPR탐사 등이 지구물리학적 탐사를 6개 측선에서 시행하여 서탑의 천부구조 영상화를 통해 지반특성과 구조적 안정성을 조사하였다. 전기비저항탐사에 의해 저비저항대 부분이 현재 탑이 남서쪽으로 기울어진 현상에 영향이 있는 것으로 해석된다. 탄성파 굴절법탐사와 GPR탐사에서 다짐층과 원지반층의 경계가 약 3.3~3.5m로 나타남이 일치하고 있으며 다짐층은 탑을 중심으로 넓게 분포하는 것이 아니라 북쪽으로 치우쳐 탑의 면적보다 작게 조서오딘 것으로 판단되고 현재 탑이 남서쪽으로 약간의 기울임을 보이는데 여기에는 지반강화대책이 필요한 것으로 판단된다.

  • PDF

탄성계수 및 간극비 평가를 위한 현장 관입형 탄성파 및 전기비저항 프로브 (Field Elastic Wave and Electrical Resistivity Penetrometer for Evaluation of Elastic Moduli and Void Ratio)

  • 윤형구;김동휘;이우진;이종섭
    • 대한토목학회논문집
    • /
    • 제30권2C호
    • /
    • pp.85-93
    • /
    • 2010
  • 전단 강성은 지반 거동을 이해하기 위한 필수적인 요소로 인식되고 있으며, 특히 탄성계수 및 간극비는 구조물의 기본적인 설계 정수로서 그 중요성이 점차 증가하고 있다. 본 연구의 목적은 전단파와 압축파 같은 탄성파 및 전기비저항 측정이 가능한 현장 탄성파 및 전기비저항 측정 장비(FVRP)를 개발하고, 이를 이용하여 대상지반의 탄성계수 및 간극비를 산정하는 것이다. 압축파 및 전단파는 각각 피에조 디스크 엘리먼트와 벤더 엘리먼트를 이용하여 측정하였다. 그리고 전기비저항은 소형 전기비저항 측정 프로브를 제작하여FVRP 선단에 설치하여 측정하였다. 개발된 장비는 실내의 대형토조와 현장에 적용되었다. 대형 토조실험의 경우, 모래와 점토를 슬러리 상태에서 혼합하여 지반을 조성한 후 상재하중을 가하여 조성된 지반을 압밀 시킨 후 진행되었으며, 탄성파 및 전기비저항의 측정은 매 심도 1cm 간격으로 수행되었다. 현장 실험은 남해안 지역에서 수행되었으며, 탄성파 및 전기비저항 측정은 관입심도 6m부터 20m까지 10cm 간격으로 수행하였다. 토조 및 현장 실험을 통해 측정된 탄성파와 전기비저항은 이론적인 관계식을 이용하여 탄성계수 및 간극비로 환산되었다. 탄성파와 전기비저항을 이용한 간극비는 부피를 이용하여 산정한 간극비와 유사한 값을 나타내었다. 본 연구에서 개발된 탄성파와 전기비저항을 동시에 측정할 수 있는 FVRP는 연약지반의 탄성계수 및 간극비 산정에 유용한 장비가 될 수 있음을 보여준다.

제방누수조사에의 물리탐사기법의 활용(쌍극자배열 전기비저항탐사와 SP탐사를 중심으로) (Application of Geophysical Exploration Methods to Seepage Bone Investigation of Dam Structures)

  • 원종근;송성호
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 1999년도 제2회 학술발표회
    • /
    • pp.240-257
    • /
    • 1999
  • 우리나라의 저수지 총수 18,032 개소의 $16\%$에 달하는 저수지가 누수를 겪고 있다. 이러한 불안전 시설물 조사에 있어서 물리탐사기법의 활용은 경제적 측면에서 지극히 자연스러운 흐름이다. 본 연구에서는 전기비저항탐사에 의해 이미 조사된 자료들을 분석하여 현장측정값의 모형을 보여주고 저수지에서의 누수조사 현장경험을 기술하였으며 토질과 전기비저항값의 상관관계를 분석하여 모래함량과의 연관성을 얻었다. 또한 SP탐사기법은 방조제뿐만 아니라 저수지 누수 조사에서도 효과가 있는 것으로 분석되었다.

  • PDF

소형루프 전자탐사법에 의한 간척지 지반조사 (Site Investigation of a Reclaimed Saline Land by the Small Loop EM Method)

  • 김기주;안동국;조인기;김봉찬;경규하;홍재호
    • 지구물리와물리탐사
    • /
    • 제13권2호
    • /
    • pp.175-180
    • /
    • 2010
  • 소형루프 전자탐사법은 기동성이 뛰어나고 편리한 물리탐사법의 하나로 지하 천부의 전기비저항 분포에 관한 정보획득에 매우 효과적이다. 또한 이 방법은 전기전도도가 너무 높아 전기비저항 탐사가 용이하지 않은 지역에서 전기비저항 탐사의 적극적 대안이 될 수 있다. 본 연구에서는 염분에 의해 심하게 오염된 간척지의 지반조사를 위하여 다중 주파수 소형루프 전자탐사를 적용하였다. 획득된 소형루프 전자탐사 자료에 대하여 측점별로 1차원 역산을 수행하고, 이들 자료를 병합하여 전기비저항의 3차원적 분포현황을 파악하였다. 전자탐사에서 얻어진 전기비저항 분포와 16개 시추공에서 얻어진 주상도 및 토양시료의 전기비저항 값을 비교 분석하여 매립토 두께, 염도분포 등 조사지역의 지반특성을 제공하였다.